Loading...
HomeMy WebLinkAboutWell Inspection 977 Foster Street Extens ENVIROTECH LABORATORY TESTING & CONSULTING 77 COOK HILL ROAD • WINDSOR, CONNECTICUT 06095 MARYELLEN DILUZIO TELEPHONE July 16, 1998 (860) 688-7249 Clerke Inspection P.O.Box 674 South Windsor, Ct. 06074 Dear Sir; We have the following to report on the sample submitted to this Laboratory on July 13, 1998. Sample Number: 41244 Mark: water sample collected 7/11/98 by Don Clerke from Lot No.977,Foster St.Ext.,South Windsor,Ct. CURRENT MAXIMUM CONTAlMINATION TEST PARAMETERS TEST RESULTS LEVELS (MCL) in ODOR NONE NO MCL COLOR 0 NO MCL TURBIDITY 0 NO MCL PH 6.86 NO MCL NITRITE NITROGEN <0.001 1.0 m NITRATE NITROGEN 2.50 10 CHLORIDE 15 250 mgtL HARDNESS 180 NO MCL IRON <0.05 NO MCL MANGANESE <0.05 NO MCL SODIUM 61.9 NO MCL SULFATE 16.5 NO MCL BACTERIOLOGICAL EXAM Number of Coliform Bacteria Per 100 mLs(membrane filter) TNTC 0 Due to the presence of Coliform Bacteria this water is not classed entirely safe for drinking. We recommend sterilizing the well and retesting for bacteria. All other parameters analyzed are below Maximum Contamination Levels(MCL's)for potable water. The sodium content is above the recommended 28 mg1L limit established for people on low salt diets. If there are any questions we would be pleased to discuss them with you. Very truly yours, Envir boratory Marye uzio PH 0464 cc: one enclosed PHYSICAL PARAMETERS ODOR; MCL = none, recommended < 2 - Scale 0 = none, 1 = very faint, 2 = faint, 3 = distinct, 4 = decided. 5 = stronq; Good well water should be free of odor. TURBIDITY; MCL = none, recommended < 5 - A measure of Particles in the water, usually indicates iron. PH; MCL = none, recommended 6.4 - 10.0 - pH ranqes from 0 - 14. A pH of 7 is neutral , t 7 is acidic, ; 7 is basic. A pH less than 6.4 is considered acidic and may be corrosive to piping. COLOR; MCL = none, recommended C 15 - High color usuallv indicates the presence of iron. INORGANIC PARAMETERS NIRITE NITROGEN; MCL 1.0 mq/L - An intermediate breakdown product of organic matter. See nitrate comment. NITRATE NITROGEN; MCL 10.0 mq/L - The final completely oxidized staqe of nitroqen. Levels above 10 are known to be harmful to infants. Preqnant/nursinq mothers and parents of infants should consult with a phvsican. CHLORIDE; MCL 250 mq/L - The non-metallic portion of common salt. Levels above 50 mq/L may indicate undesirably high sodium levels and it also may appreciably increase corrosion rates. Levels above 250 mq/L inpart a salty taste noticeable to most people. HARDNESS; MCL none - A measure of the total calcium and magnesium in water. Waters over 100 mq/L are described as hard and levels over 250 mq/L are considered very hard. The effect of hardness is to increase the amount of soap necessary to form suds with water. Hiqh levels may also increase scaling on the inside of water pipes. IRON; MCL none - Above 0.3 mq/L iron may cause staining to laundry and fixtures. Iron is naturally occurrinq water mineral due to the geology of the area. MANGENESE; MCL none - Above 0.05 mq/L mangense may cause staininq to laundry and fixtures. See iron comment SULFATE; MCL none - A naturally occuring substance in water, levels above 250 mq/L may inpart a bitter taste and render a laxative effect. SODIUM; MCL none - A notification level of 28 mq/L has been established for people on low salt diets, high levels may increase the corrosive effect. ORGANIC CHEMICALS VOLATILE ORGANIC CHEMICALS (VOC) - see report for a listinq of the individual chemical MCL. VOC's are a qas chro- matographic scan of 58 compounds. This list was de- termined by the Conneticut State Department of Health. These compounds include some of the more commonly found ground water contaminates.