Loading...
HomeMy WebLinkAboutWell Inspection 176 West Road O � rA U 1540 SULLIVAN AVENUE'- SOUTH WINDSOR, CONN. 06074 R•c AREA CODE 203/644-2511 June 16, 1993 Sullivan Avenue Associates 681 John Fitch Blvd. South Windsor, Connecticut Gentlemen: This correspondence references the water sample collected from 175 West Road, South Windsor (sample I.D. AA 23866) by Darrell Cha 7ou 7t on June 10, 1993. A 7though the water supply has sodium remova 7 equ� meet insta 77ed the lab report (Phoenix Environmental Laboratories Inc.f dated June 15, 1993 indicates a sodium concentration of 71 milligrams per liter. This level exceeds the State Health Department guideline of 28 mg/L. It is recommended that any users of this water supp 7y who are on a sodium restricted diet notify their physicians of the sodium content. Very tru 7y yours, ri Robert ep u a, P.S. Environmental Health Officer I 'r (- as a representative of Su l l i van Avenue Associates, ner of the property located at 175 West Road, South Windsor, state that I will present this document to any potential buyer prior to transfer of title. pres n to t i ve Date RD:jh F k Sc fW r*.�.iyd� fy-- S: E I 4 .ter•F �S�� yl �� y�-'e yL+S t �3 a h.% i"� { 1 v. h F�•` tz].�a r r r Environmental Laboratories, Inc. ., rV 587 East M.iddle'Turnpike,"PO. Box418, Manchester, CT.06040 f: j 3 t ti 'j Tel (203)6451102 Fax;(203)645 082$ � 1 . 1 3 A s June 15, 1993 South 4�Vi�tisQr " F B�1ft �IN "[ EEAFTN�EiVT Mr. ' Darrell Chaloult ., 17.5-.West Road South .Windsor; Ct Q6074 SAMPLE I.;D D.#: AA2 3 8 6,6, ~AA2.4 0 4 5 and`AA a 24046 .f , t .. k v , t � £t f ° , Sj s •S r �. - 'This- laboratory ,is� in `'compliance with the A/ C Q Q procedure outlined�'`in EPA6.00/4-79-.019 : Handbook for Analytical Quality Control`'in Water' and Waste Water, March "19,79, ;and SW846 QA/QC requirements :of „procedures :.used. s If you have ,any ,questions;.concernin this testin 1 notf;hesitate ; o 'contact me g g, please, sio Sincerely yours, ti SohailjJahani F 'Laboratory •Director t y= CT. Lab. Registration #PH-0618 MA_,'Lab. �Registration-#CT-007 NY' Lab. Registration 411301 RI Lab.' Re"gistration. ;#0045 4 re 1 r From: . Phoenix Environmental Laboratories Inc. 587 E.; Middle Turnpike, Box 418 Manchester, Ct. 06045-0418 (203) 645-1102 Fax 645-0823 June 15, 1993 To Mr. Darrell Chaloult 175 West Road South Windsor, CT 06074 The following analytical results have been obtained for the indicated sample which was submitted to this laboratory: Sample I .D.` AA23866 Location code: SPECIAL Project account code: RUSH Location Description: Well Water Sample Sample collector: D. CHALOULT Sample collection date: 06/10/93 Time: 06:50 Lab submittal date: 06/10/93 Time: 07:20 Parameter Result Units MDL Total Metals Digest. H2O Matrix. Completed PH 10.61 pH Units 0. 10 Hardness Water Matrix Below det lim mg/L 2 .0 Sodium Water Matrix 71 mg/L 0. 10 Chloride Water Matrix 51.0 mg/L 2.0 Color Below det lien 1 Odor - Water Matrix Below det lim T.O.N. Number 1 Turbidity - Water Matrix 0.57 NTU 0 Nitrite Water Matrix Below det lien mg/L 0.01 Nitrate Water Matrix 0.21 mg/L 0.01 Copper Water Matrix Below det lien mg/L 0.01 Iron Water Matrix Below det lim mg/L 0.01 Manganese Water Matrix Below det lim mg/L 0.01 l Total Coliforms / 00 mis. 0� Sample comments: This sample represents a potable (drinkable) water supply as regards Total Coliforms, Nitrate and Chlorides. Please see the enclosed information for further details. Note that the result for pH is above the Acceptable Range and the result for Sodium is above the Advisory Limit. 'Mr. Darrell Chaloult Sample I.D. AA23866 (continued) Page 2 June 15, -1993 If there are any questions regarding this data, please call. Sohail Jahani Laboratory Director from: Phoenix Environmental Laboratories Inc. a 587 E ' Middle' Turnpike, Box 418 Manchester, `Ct. 06045-0418 (203) 645-1102 Fax 645-0823 June 15, 1993 To: Mr. Darrell Chalout 175 West RD. S. Windsor, CT 06074 The following analytical results have been obtained for the indicated sample which was submitted to this laboratory: Sample I.D. 'AA24046 Location code: SPECIAL Location Description: # 2 Faucet Sample collector: D. CHALOUT Sample collection date: 06/15/93 Lab submittal date: 06/15/93 Time: 07:35 Parameter Result Units MDL PH 8. 19 pH Units 0.10 Sample comments: , This sample is a resample of sample # AA23866 and represents a potable (drinkable) water supply as regards pH. Y If there are any questions regarding this data, please call. Sohail Jahani Laboratory Director P NI X Environmental Laboratories, Inc. - 587 East Middle Turnpike, P.O. Box 418, 'Manchester, CT 06040 Tel. (203)645-1102 Fax (203)645-0823 �_ '� e's fdccl October 8, 1993 Mr. Darrell Chaloult 681 John Fitch Blvd. South Windsor, CT 06074 SAMPLE I.D.#: AA28404 This Laboratory is in compliance with the QA/QC procedure outlined in 'EPA 600/4-79-019, Handbook for Analytical Quality Control in Water and Waste Water, 'March 1979, and SW846 QA/QC requirements of procedures used If you have any questions concerning this testing, please do not hesitate to contact me'. Sincerely yours, Sohail Jahahi Laboratory Director ; CT Lab. Registration #PH-0618 MA Lab. Registration #CT-0'07 NY Lab Registration #1130I RI Lab. Registration #63 NH Lab, Registration #213693-A,B From: Phoenix Environmental Laboratories Inc. 587 E. Middle Turnpike, Box 418 Manchester, Ct. 06045-0418 (203) 645-1102 Fax 645-0823 October 8, 1993 To: Mr. Darrell Chaloult 681 John Fitch Blvd. South Windsor, CT 06074 The following analytical results have been obtained for the indicated sample which was submitted to this laboratory: Sample I.D. AA28404 Location code: SPECIAL Location Description: WEST ROAD SO.WINDSOR WELLWATER Sample collection date: 09/28/93 Time: 14:15 Lab submittal date: 09/28/93 Time: 15:10 Parameter Result Units MDL Total Metals Digest. H2O Matrix. Completed PH 7.83 pH Units 0.10 Hardness Water Matrix - 137 mg/L 2 .0 Sodium Water Matrix 12 mg/L 0.10 Chloride Water Matrix 8.92 mg/L 2 .0 Color Below det lim 1 Odor - Water Matrix Below det lim T.O.N. Number 1 Turbidity- Water Matrix 0.75 NTU 0 Nitrite Water Matrix Below det lim mg/L 0.01 Nitrate Water Matrix .274 mg/L 0.01 Copper Water Matrix .09 mg/L 0.01 Iron Water Matrix .04 mg/L 0.01 Manganese Water Matrix .03 mg/L 0.01 Total Coliforms 0 /100 mis. 0 Sample comments: This sample represents a potable (drinkable) water supply for the parameters tested. Please see the enclosed information for further details. If there are any questions regarding this data, please call. Sohail Jahani Laboratory Director PHOENIX ENVIRONMENTAL LABORATORIES INC. STANDARD WATER TEST FOR PRIVATE WELLS Maximum Contaminant Level: Test results must be less than the "Maximum Contaminant Level" for a potable supply. Water should not be used particularly for drinking, cooking for ingestion if the "Maximum Contaminant Level" is exceeded. Advisory Limits-: Results greater than the "Advisory Limits" may impose aesthetic or physical qualities that make the water undesirable for use. 1. pH: Acceptable Range - 6.4 - 8.5 pH units. 2. Hardness: Advisory Limit - 200 mg/L (as CACO3). When determining the corrosiveness of scale-forming properties of well water, the pH and hardness are taken into consideration. If well water falls within the limits given in #1 - 2 above, there is usually no need for treatment. 3. Chloride: Maximum Contaminant Level - 250 mg/L. 4. sodium : Advisory limits Sodium 28.0 mg/L Sodium is frequently combined with.chloride in water as salt. Well water near the ocean may have high salt levels. The salting of roads, storage of salt, and water that has been softened will cause water to have high sodium levels. 5. Color: Advisory Limit is 15 PCU. ( see iron and manganese) 6. odor: Advisory Limit is 2_ Most organic and some inorganic chemicals contribute to odor. They may originate from natural sources ( decomposition of vegetable matter), or from associated microbial activity. The most common odor in well water is from vegetable_ matter decomposition. The.smell resembles rotten eggs and -is usually from 'hydrogen sulfide._ Ari'activated<carbon filter will `normally .elim nate these odors. 7. Turbidity: Advisory Limit is 5 NTU ( See iron and manganese) . 8. & 9. Nitrite and Nitrate: Maximum Contaminant Level Limits -1.0 mg/L Nitrite and 10 mg/L Nitrate plus Nitrite. Nitrates get into well water from sewage disposal and from fertilizer. The best form of control is removal of the source. 10. Copper: Advisory Limit - 1.0 mg/L. Copper effects taste and the staining of porcelain. ll.& 12. Iron and Manganese: Advisory Limits are: Iron 0.3 mg/L and Manganese 0.05 mg/L. High iron and manganese levels may be caused by rusty pipes, water storage tanks, or pumps. High levels will cause the turbidity and color levels to rise above the recommended levels. In some cases, new wells will be turbid and orange in color. This is usually temporary and will dissipate upon continuous usage of the water. In some areas, high iron levels are naturally occurring and some type of treatment may be required. 13. Coliform Organisms: Maximum Contaminant Level 0/100 ml. The presence of harmful bacteria discharged in the waste excretions of humans and animals is indicated by the lab test for coliform organisms. Their presence is evidence that the water may have been contaminated by sewage discharge and may contain dangerous disease-producing organisms. Whenever a well is contaminated by coliform organisms, the cause must be located and corrected. INVOICE From: Phoenix Environmental Laboratories Inc. 587 E. Middle Turnpike, Box 418 Manchester, Ct. 06045-0418 (203) 645-1102 Fax 645-0823 Invoice Number: 9843 Date: October 8, 1993 To: Mr. Darrell Chaloult 681 John Fitch Blvd. South Windsor, CT 06074 The following charges are due for the indicated sample which was submitted to this laboratory on 09/28/93. Lab Sample I.D. AA28404 Purchase order number: Location code: SPECIAL WEST ROAD SO.WINDSOR WELLWATER Parameter Analyzed Cost Total Metals Digest. H2O Matrix. $0.00 H 0.00 P - Hardness Water Matrix 0.00 Sodium Water Matrix Chloride Water Matrix 0.00 Color 0.00 Odor - Water Matrix 0.00 Turbidity - Water Matrix 0.00 Nitrite Water Matrix 0.00 Nitrate Water Matrix 0.00 Copper Water Matrix 0.00 Iron Water Matrix 0.00 Manganese Water Matrix 0.00 Total Coliforms 0.00 Quotation for Services - Total 60.00 Total amount due for services on sample AA28404: $60.00 Remit payment to: Phoenix Environmental Laboratories Inc. P.O. Box 418, Manchester Ct 06045-0418 -Interest at 1.5%/month charged to accounts over 30 days . Any collection expenses incurred additional.