HomeMy WebLinkAboutWell Inspection 935 Avery Street lob 0.
�'W N S.eq 1®�
F TO-U-0n O-P Sllaao& Vzhodi�t
w� 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CONN. 06074
tGJ��SoR•Co AREA CODE 203/644-2511
December 30, 1993
Ms. Rosemary Hogen
935 Avery Street
South Windsor, CT 06074
Dear Ms. Hogen:
As you are aware, a sample of your drinking water was collected and
delivered to the State Health Department labortory for analysis.
No bacterial contamination was present. Also, all chemical parameters
tested for (pH, Ammonia, hardness, etc.) were within guidelines for a
potab 1 e water supply.
Due to your qua 1 i ty comp 1 a int of odor, two specific tests were requested.
The first was for hydrogen sulfide which may cause a sulfur or rotten egg
type odor. Hydrogen sulfide was not detected.
The second test was for iron bacteria. This is not a disease causing
bacteria, but may produce an odor (usually sulfur or septic type). Iron
bacteria is present in you water supply and is most likely the cause of the
odor in your water.
This problem can easily be rectified by chlorination of the water supply as
described to you in our recent telephone conversation. Usually, one
chlorination process corrects the problem. However, periodic chlorination
may be necessary.
If you have any questions, please call me at the South Windsor Town Hall at
644-2511, Extension 248.
Very truly yours,
rl �
Robert Dept 7c7a R. S.
Environmental Health Officer
RD:jh
-cc: Michael R. Lariviere•
Patricia G. Cross
138 Cambridge Drive
South Windsor, CT
r
STATE OF CONNECTICUT
Dept.of Public Health and Addiction Services
Bureau of Laboratories R:H1 2153756 IS06074 0 1
10 Clinton St.
P.O.Box 1689 INFORMATION
Hartford,CT06144 32SOUTH WINDSOR
TELEPHONE:(203)566-5063 OG E N
F -1 35 AVERY ST
OUTH WINDSOR CT
ROBERT DEPTULAe SANITARIAN
1540 SULLIVAN AVE 1 RECEIVED REPORTED
TOWN HALL 11123193 1/24/93 12116193
L SOUTH WINDSOR CT 06074 1 0:15 1:24 0:57
- -•- FINAL REPORT •
SAMPLING POINT: TAP
COLLECTOR. ROBERT DEPTULA TITLE 5ANIT
PRIVATE WELL TREATMENT: NONE
COMPLAINT ODOR
USE: CONSTANT
SOURCE: DRILLED WELL
DIAMETER: 6 IN
iATEITIM€ ANALYZED 11124193 134
INALYZED BY RG
kNA1LYTICAL METHOD MEMBRANE FILTER TECHNIQUE
'OTAL COLIFORM ABSENT PER 100 AIL
:ONE. TOTAL COLIFORM ABSENT PER 100 Mt
:SCHERICH IA COLI ASSENT PER 100 ML
:RON BACTERIA WATER GALL.IONELLA SP. PRESENT: 6001100 IL.
IT IS DIFFICULT TO EttUMERATE IRON BACTERIA BECAUSE OF ITS
CELLULAR MORPHOLOGY. THE NUMERICAL VALUE FOR THIS R=SULT
IS AN ESTIMATED COUNT.
LPPARENT COLOR 0
'RUE COLOR 0
iDOR NONE
'URBIDITY 0.$
H 7.3
MMONIA <0.05
U-NITS MG1L UNLESS NOTED
LKALINITY 602 100.
ARD'NESS; 110.
HLORIDE 502 25.
ITRATE 203 5.9
ITRITE <0.05
ETERGENT CMPLX 704 MORE DETECTED
YDROGEN SULFIDE 509 DONE DETECTED
RON 113' 0.01
WDERNATM
* CONTI l7ED
:ORM NO.OL-6A
r
STATE OF CONNECTICUT ACCESSION NO. ACCOUNTN�O. A�GE ��
Dept.of Public Health and Addiction Services 7R-. 215 375 6 S06074 0
Bureau of Laboratories
10 Clinton St.
P.O.Box 1689 INFORMATION
Hartford,CT 06144 32SOUTH WINDSOR
TELEPHONE:(203)566-5063 OG E N
F 35 AVER Y ST
OUTR WINDSOR CT
ROUERT DEPTULA. SANITARIAN
1540 SULLIVAN AVE -
TOWN HALL 1123/93 1124/93 2/16193
L SOUTH WINDSOR CT 06074 J 0:15 1:24 0:57
- -•- FINAL R£P4RT •
IANGANESE 0.03
;ODIUM.r 'DIRECT 11.
�ULFATES,COMPLEX 507 41.
ORM NO.OL-6A