HomeMy WebLinkAboutWell Inspection 848 Strong Road ENVIROTECI3 LABORATORY TESTING & CONSULTING 77 COOK HILL ROAD . WINDSOR. CONNECTICUT 06095 MARYELLEN DiLUZ10 TELEPHONE (203) 688.7249 May 29, 1997 Jeff and Mary Mattis 4 fen Ct. Wallingford, Ct. 06492 Dear Jeff and Mary, We have the fallowing to report on the samples submitted to this laboratory on May 21 , 1997. Sample Number: 38103 Mark: water sample collected 5/20/97 by Tony Rinaldi from Lot No. 848, Stron Rd. , South Windsor, Ct. Results, mg/L MCL, mg/L Odor 0 no MCL Turbidity 350 no MCL Color > 100 no MCL Turbidity-treated 0 no MCL. Color -treated 0 no MCL PH 7.73 no MCL Nitrite Nitrogen < 0.001 1 .0 Nitrate Nitrogen < 1 .00 10.0 Chloride (as Cl ) i8 250 Hardness (as CaCO3) 160 no MCL Iron (as Fe) 5.85 no MCL Mangenese 0.115 no MCL Sodium 1€3 no MCL Sulfate 67.5 no MCL VOC' BDL see next pages BACTERIOLOGICAL EXAMINATION Number- of Co 1 iform Bacteria per 100 mLs (membrane filter ) O O All parameters analyzed are below Maximum Contamination Levels (MCL) for potable water. However the turbidity, color- , iron and mangenese contents .are extremely high. Levels this high will cause staining. We recommond that only treated water be used for drinking. If there are any questions we would be pleased to discuss them with you. Very truly yours, Envir h Laboratory Ma,rye UiLuzio PH0464, PHO514 w PHYSICAL PARAMETERS ODOR; MCL = 2 - Scale O = none, l = very faint, 2 = faint 3 = distinct,_ 4 = decided, 5 = strong. Good well water should be free of odor. TURBIDITY; MCL 5 - A measure of particles in the water, ' usually an indication of the presence of iron. pH; MCL 6.4 - 10.0 - pH ranges from 0 - 14. A pH of 7 is neurtal, C 7 is acidic, > 7 is basic. A pH less than 6.4 is considered acidic and may be corrosive to piping. COLOR; MCL 15 - High color usually indicates the presence of iron. INORGANIC PARAMETERS NIRITE NITROGEN; MCL 1.0 mg/L - An intermediate breakdown product of organic matter. See nitrate comment. NITRATE NITROGEN; MCL 10.0 mg/L - The final completely oxidized stage of nitrogen. Levels •above 10 are known to be harmful to infants. Pregnant/nursing mothers and parents of infants should consult with a physican. CHLORIDE; MCL 250 mg/L - The non-metallic portion of common salt. Levels above 50 mg/L may indicate undesirably high sodium levels and it also may appreciably increase corrosion rates. Levels above 250 mg/L inpart a salty taste noticeable to most people. HARDNESS; MCL none - A measure of the total calcium and magnesium in water. Waters over 100 mg/L are described as hard and levels over 250 mg/L are considered very hard. The effect of hardness is to increase the amount of soap necessary to form suds with water. High levels may also increase scaling on the inside of water pipes. IRON; MCL none - Above 0.3 mg/L iron may cause staining to laundry and fixtures. Iron is naturally occurring water mineral due to the geology of the area. MANGENESE; MCL none - Above 0.05 mg/L mangense may cause staining to laundry and fixtures. See iron comment SULFATE; MCL none - A naturally occuring substance in water, levels above 250 mg/L may inpart a bitter taste and render a laxative effect. SODIUM; MCL none - A notification level of 28 mg/L has been established for people on low salt diets, high levels may increase the corrosive effect. ORGANIC CHEMICALS VOLATILE ORGANIC CHEMICALS (VOC) - see report for a listing of the individual chemical MCL. VOC's are a gas chro- matographic scan of 58 compounds. This list was de- termined by the Conneticut State Department of Health. These compounds include some of the more commonly found ground water contaminates. ENVIROTECA LABORATORY TESTING & CONSULTING 77 COOK HILL ROAD • WINDSOR, CONNECTICUT 06095 MARYELLEN DiLUZ10 TELEPHONE (203) 688-7249 4ti ( t. De at' Ja?f it aid " a:-Y� 1� halve th-p -Fol 4"wiful to Y°f pof-1, 1•!1 the 4a'ampjf—s aw.A.ml, w tf.4 + t.`, Lh i rm Pier 21 )r9f . Simp II o futimb ov t M3 1 t2 } f1 ,4v- 2 watwv ca slu- S/20/97 by 1olvt ' fUnald st�kn No. U48 o :I-1 v ov i R41- 9, f4oiLl Ut 44 j ktlsr:,e C t; ORGAINIC CHEMICALS BY EPA 502.2 Results NCL MDL in ug/L in ug/L Benzene 0.5 BDL 5 Bromobenzene 0.5 BDL Bromomethane 0.5 BDL n-Butylbenzene 0.5 BDL Carbon Tetrachloride 0.5 BDL 5 Chlorobenzene 0.5 BDL 100 Chloroethane 0.5 BDL Chloromethane 0.5 BDL 2-Chlorotoluene 0.5 BDL � 4-Chlorotoiuene 0.5 BDL Dibromomethane 0.5 BDL 1 ,2-Dichlorobenzene 0.5 BDL 600 1 ,3-Dichlorobenzene 0.5 BDL iE 1,44-1)ichlorobenzene 0.5 BDL 75 1 ,1-Dichloroethane 0.5 BDL � 1 ,2-Dichloroethane (EDC) 0.5 BDL 5 1 ,1-Dichloroethylene 0.5 BDL 7 cis-1 ,2-Dichloroethylene 0.5 BDL 70 Trans-1 ,2-Dichloroethylene 0.5 BDL 100 1,2-Dichloropropane 0.5 BDL 5 1 ,3-Dichloropropane 0.5 BDL �€ 2,2-Dichloropropane 0.5 BDL 1 , 1-Dichloropropylene 0.5 - BDL � cis-1 ,3-Dichloropropylene 0.5 BDL � trans-1 ,3-Dichloropropylene 0.5 BDL Ethylbenzene 0.5 BDL 700 Methylene Chloride 0.5 BDL 5 EPA Method 502.2 Results MCL MDL in ug/L in ug/L MethylTertButylEther (MTBE) 2.0 BDL Naphthalene 0.5 BDL n-Propylbenzene 0.5 BDL Styrene 0.5 BDL 110 1,1 , 1,2-Tetrachloroethane 0.5 BDL 1 , 1 ,2,2-Tetrachloroethane 0.5 BDL Tetrachloroethylene 0.5 BDL 5 Toluene 0.5 BDL 1000 Total Trihalomethanes (TTHM) BDL 100 Bromodichloromethane 0.5 BDL Bromoform 0.5 BDL Chlorodibromomethane 0.5 BDL Chloroform 0.5 BDL 1,2,4-Trichlorobenzene 0.5 BDL 5 1, 1 , 1-Trichloroethane 0.5 BDL 200 1, 1 ,2-Trichloroethane 0.5 BDL 5 Trichloroethylene 0.5 BDL 5 1,2,3-Trichloropropane 0.5 BDL 112,4-Trimethylbenzene 0.5 BDL 1,3,5-Trimethylbenzene 0.5 BDL Vinyl Chloride 0.5 BDL 2 Xylenes (total ) 10000 o-Xylene 0.5 BDL p/m Xylene 0.5 BDL MDL = minimum detectable level BDL = below MDL MCL = maximum contaminant level * = no MCL established = MCL is for the combined four TTHWs = MCL is for the combined three Xylene If there are any questions we would be pleased to discuss them with you. Very truly yours, E4§ii s h Laboratory Maryellen DiLuzio cc: one enclosed PH-0464 & PH-0547