HomeMy WebLinkAboutWell Inspection 79 Pierce Road Columbia Environmental Laboratory
Drinking Water Analysis - Formaldehyde Testing
James Pelletier STATE OF CONNECTICUT
746 Wrights.Mill Road DEPARTMENT OF HEALTH
Coventry, CT 06238 CERTIFICATION NUMBER
PH-0514
RE: Lab No. 960416, Inv, No. 96311 April 5, 1996
SAMPLING LOCATION: 79 Pierce Road, South Windsor, Connecticut
SAMPLING/DELIVERY TIMES: '1515/1720 Laboratory Sampled 4/3/96
STANDARD WATER ANALYSIS STATE OF CONNECTICUT
TEST RESULTS RECOMMENDED/MAXIMUM LEVELS
RECOMMENDED
PH' UNITS 7.1 6.5-9.0 RANGE
COLOR UNITS 15 RECOMMENDED
5 MAXIMUM
ODOR 0-5 RECOMMENDED
0 (none) 3 MAXIMUM
TURBIDITY NTU 5 RECOMMENDED
4.7 MAXIMUM
ALKALINITY mg/L NO RECOMMENDED LEVEL
CHLORIDE mg/L 250 MAXIMUM
43 ALLOWABLE
HARDNESS mg/L 382 0-60 soft, 61-120 mod. hard
121-180 hard, >181 v. hard
AMMONIA AS N mg/L "r` <.05 .050 RECOMMENDED
MAXIMUM
NITRITE AS N mg/L <.005 1.0 MAXIMUM
ALLOWABLE
NITRATE AS N mg/L 0.12 10.0 MAXIMUM
ALLOWABLE
DETERGENTS mg/L <Q 5 0.5 MAXIMUM
ALLOWABLE
IRON mg/L RECOMMENDED
0 33 0.3 MAXIMUM
MANGANESE mg/L 021 .050 RECOMMENDED
MAXIMUM
SODIUM mg/L 28 28 RECOMMENDED
MAXIMUM
COLIFORM BACTERIA 0/100 ml 0/100 ml MAXIMUM
ALLOWABLE
For the parameters Analyzed,this is a satisfactory potable drinking water supply. It may be objectionable due to the high
concentration of iron,which contributes to the color and turbidity. Treatment for removal may be warranted at this
concentration. It may be objectionable due to the hardness. Further flushing would be warranted. A high concentration of
iron or hardness is NOT a basis for the rejection of a drinking water supply.
If you have any questions,please feel free to call. Very truly yours,
qJhn C. Burrell
2 Lakeview Park West • Columbia, CT 06237 • Telephone: (860) 228-0329