HomeMy WebLinkAboutWell Inspection 29 Griffin Road t
ENVIROTEc,H LABORATORY
TESTING & CONSULTING
77 COOK HILL ROAD • WINDSOR,'CONNECTICUT 06095
MARYELLEN DiLUZ10 TELEPHONE
(203) 688-7249
May 29, 1997
Edwin W. Davis
29 Griffin Rd.
Broad Brook, Ct. 06016
Dear Sir-P
We have the following to report on the samples submitted to
this laboratory on May 27, 1997.
Sample Number: 38140
Markr water sample Collected 5/27/97 by Edwin Davis from
4ot No. 494, Niederwerfer Rd. , South Windsor} Ct.
Results, mg/L MCL, mg/'L
Odor 0 no MCL
Turbidity 1 no MCL
Color D no MCL
PH 7.83 no MCL
Nitrite Nitrogen < 0.001 1 .0
Nitrate Nitrogen < 1.00 10.0
Chloride (as C1 ) 52 250
Hardness (as CaCO3) 124 no MCL
Iron (as Fe) < 0, 10 no MCL
Manganese < 0.05 no MCL
Sodium 13 no MCL
Sulfate 10.5 no MCL
VOC' BDL see next pages
BACTERIOLOGICAL EXAMINATION
Number of Colifor>m Bacteria
per 100 mLs (membrane filter) 0 D
All parameters analyzed are below Maximum Contamination
Levels (MCL) for potable water. If there are any questions
we would be pleased to discuss therm with you.
Very t yours,
Envir ch boratory
Maryellen iLuzio
PH0464p PHO514
cc2 Sanitarin, South Windsor
PHYSICAL PARAMETERS
ODOR; MCL = 2 - Scale 0 = none, 1 = very faint, 2 = faint
3 = distinct, 4 = decided, 5 = strong. Good well
water should be free of odor.
TURBIDITY; MCL 5 - A measure of particles in the water,
usually an indication of the presence of iron.
pH; MCL 6.4 - 10.0 - pH ranges from 0 - 14. A pH of 7 is
neurtal, < 7 is acidic, > 7 is basic. A pH less than
6.4 is considered acidic and may be corrosive to
piping.
COLOR; MCL 15 - High color usually indicates the presence
of iron.
INORGANIC PARAMETERS
NIRITE NITROGEN; MCL 1.0 mg/L - An intermediate breakdown
product of organic matter. See nitrate comment.
NITRATE NITROGEN; MCL 10.0 mg/L - The final completely
oxidized stage of nitrogen. Levels above 10 are known
to be harmful to infants. Pregnant/nursing mothers
and parents of infants should consult with a physican.
CHLORIDE; MCL 250 mg/L - The non-metallic portion of common
salt. Levels above 50 mg/L may indicate undesirably
high sodium levels and it also may appreciably
increase corrosion rates. Levels above 250 mg/L inpart
a salty taste noticeable to most people.
HARDNESS; MCL none - A measure of the -total calcium and
magnesium in water. Waters over 100 mg/L are described
as hard and levels over 250 mg/L are considered very
hard. The effect of hardness is to increase the amount
of soap necessary to form suds with water. High levels
may also increase scaling on the inside of water pipes.
IRON; MCL none - Above 0.3 mg/L iron may cause staining to
laundry and fixtures. Iron is naturally occurring
water mineral due to the geology of the area.
MANGENESE; MCL none - Above 0.05 mg/L mangense may cause
staining to laundry and fixtures. See iron comment
SULFATE; MCL none - A naturally occuring substance in
water, levels above 250 mg/L may inpart a bitter taste
and render a laxative effect.
SODIUM; MCL none - A notification level of 28 mg/L has been
established for people on low salt diets, high levels
may increase the corrosive effect.
ORGANIC CHEMICALS
VOLATILE ORGANIC CHEMICALS (VOC) - see report for a listing
of the individual chemical MCL. VOC's are a gas chro-
matographic scan of 58 compounds. This list was de-
termined by the Conneticut State Department of Health.
These compounds include some of the more commonly found
ground water contaminates.
ENVIROTECFI LABORATORY
TESTING & CONSULTING
77 COOK HILL ROAD • WINDSOR, CONNECTICUT 06005
MARYELLEN DiLUZJO TELEPHONE
(203) 688-7249
MAY U9 4 11? t°
E=c3wi.es W.• Davis
P9 O .i f`f i vt Rd.
Prd 441 Prot'k, Ct.. E?t'016
Pear Sil-;
WQ have thw fo i luwit:g to ref;ecat t: ear* th& rfta04)i ktZ ecd-eio t Uej ko
this laburatcyry orr May 27'. 1,�97.
S Aakp l a r&xmt(ov* 2113 140,
Marks wat>dal. Sample x o-11w:twi !Vp'7/9? by rdwi►a Davir'zi fl c"m
Lci t 1110. 4910,4 3 d. , :ic3+r rt h O i ndv ft s (-i.:
ORGA I N I C CHEMICALS BY EPA 502.2
Results MCL
MDL in ug/L in ug/L
Benzene 0.5 BDL 5
Bromobenzene 0.5 BDL �
Bromomethane 0.5 BDL
n-Butylbenzene 0.5 BDL
Carbon Tetrachloride 0.5 BDL 5
Chlorobenzene 0.5 BDL 10
Chloroethane 0.5 BDL
Chloromethane 0.5 BDL �
2-Chlorotoluene 0.5 BDL
4-Chlorotoluene 0.5 BDL �
Dibromomethane 0.5 BDL �
1 ,2-Dichlorobenzene 0.5 BDL 600
1 ,3-Dichlorobenzene 0.5 BDL
1,4-Dichlorobenzene 0.5 BDL 75
1 ,1-Dichloroethane 0.5 BDL �
192-Dichloroethane (EDC) 0.5 BDL 5
1 ,1-Dichloroethylene 0.5 BDL 7
cis-1 ,2-Dichloroethylene 0.5 BDL 70
Trans-1 ,2-Dichloroethyiene 0.5 BDL 100
1 ,2-Dichloropropane 0.5 BDL 5
1 ,3-Dichloropropane 0.5 BDL
2,2-Dichloropropane 0.5 BDL �
1 , 1-Dichloropropylene 0.5 BDL �
cis-1 ,3-Dichloropropylene 0.5 BDL
trans-1 ,3-Dichloropropylene 0.5 BDL
Ethylbenzene 0.5 BDL 700
Methylene Chloride 0.5 BDL 5
EPA Method 502.2 Results MCL
MDL in ug/L in ug/L.
MethylTertButylEther (MTBE) 2.0 BDL
Naphthalene 0.5 BDL
n-Propylbenzene 0.5 BDL
Styrene 0.5 BDL 110
1, 1 , 1,2-Tetrachloroethane 0.5 BDL
1 , 1,2,s2-Tetrachloroethane 0.5 BDL
Tetrachloroethylene 0.5 BDL 5
Toluene 0.5 BDL 1000
Total Trihalomethanes (TTHM) BDL 100
Bromodichloromethane 0.5 BDL
Bromoform 0.5 BDL
Chlorodibromomethane 0.5 BDL
Chloroform 0.5 BDL
1 ,2,4-Trichlorobenzene 0.5 BDL 5
1pl , I-Trichloroethane 0.5 BDL 200
1 , 1 ,2-Trichlorcethane 0.5 BDL 5
Trichloroethylene 0.5 BDL 5
lv2,3-Trichloropropane 0.5 BDL
112,4--Trimethylbenzene 0.5 BDL
1 ,3,5-Trimethylbenzene 0.5 BDL
Vinyl Chloride 0.5 BDL 2
Xylenes, (total ) 10000
o-Xylene 0.5 BDL
p/m Xylene 0.5 BDL
MDL = minimum detectable level BDL = below MDL
MCL = maximum contaminant level * = no MCL established
= MCL is for the combined four TTHM's
= MCL is for the combined three Xylene
If there are any questions we would be pleased to discuss
them with you.
Very truly yours,
EnviroTKc boratory
Maryellen QLuzio
cc: one enclosed
PH-0464 & PH-0547