Well Inspection 291 Oakland Road (7)
` Groundwater 31 hr il & Environmental Services, Inc. 425E Hayden Station Road Windsor, CT 06095 Tel(860)688-9023 • Fax(860)688-9278 January 6, 2009 Mr. Richard Burrill Wapping Shopping Center,LLC 52 Tallwood Drive South Windsor, CT 06074 Re: Potable Well Sampling Information 291C and 291D Oakland Road(also known as 287C and 297D,respectively) South Windsor, CT 06074 Dear Mr. Burrill, On behalf of ExxonMobil Oil Corporation, Groundwater and Environmental Services (GES), ExxonMobil's consultant, would like to thank you for allowing GES to conduct sampling of your drinking water wells on November 19, 2008 The water samples from your wells were tested for the presence of a number of volatile organic compounds found in gasoline, including methyl tertiary butyl ether (MTBE). The tests were conducted utilizing Environmental Protection Agency (EPA) approved methods and a copy of the laboratory report is enclosed. The laboratory results indicate no presence of MTBE or any other gasoline compound in your well water. As you know, the tests conducted on your drinking water well are part of an ongoing groundwater investigation being conducted under the direction of the Connecticut Department of the Environmental Protection(CT DEP). Again, thank you for your patience and cooperation. If you have any questions regarding the test results or the investigation in the area or if you notice changes in the taste, smell or appearance of your water, please feel free to call the toll free ExxonMobil Information Line at 1-877-346-0302 or, if you prefer, we suggest you contact Kevin Neary with the CT DEP at 860-424-3947 or Robert DeVito, the Environmental Health Officer for the Town of South Windsor, at 860-644-2511 ext. 248. 7Sily Matthe R. Duffy 4r Karen L. Harris Staff Environmental Scientist Senior Project Manager Enclosure cc: Kevin Neary-Connecticut Department of the Environmental Protection Robert DeVito -Town of South Windsor C. Fredrick Shaw-Town of South Windsor Jeff Folger-Town of South Windsor Walter Summers -Fire Marshal Town of South Windsor Environmental Solutions and Liability Management e-Hardeoy 2.0 A u?oniaterd Report New England - -- - r S ALL 1�4 Tate rneaxs'l 12/03/08 Technical Report for ExxonMobil GESCT:01-QQA 249 Oakland Rd., South Windsor CT - PO#4509333735 WBS#08 Accutest Job Number: M78854 Sampling Date: 11/19/08 Report to: Groundwater & Environmental Services kharrisC@gesonline.com ATTN: Karen Harris Total number of pages in report: 21 04 CO v a r a • . Test results contained within this data package meet the requirements ezaZ of the National Environmental Laboratory Accreditation Conference Lab Director and/or state specific certification programs as applicable. Client Service contact: Reza Tand 508-481-6200 Certifications:MA(M-MA136) CT(PH-0109) NH(2502) RI(00071) ME(MA0136) FL(E87579) AR SNY(11791) NJ(MA926) PA(68-01121) NC-(653) IL(200018) NAVY USACE This report shall not be reproduced,except in its entirety,without the written approval of Accutest Laboratories. Test results relate only to samples analyzed. New England • 495 Tech Center West • Building 1 • Marlborough,MA 01752 • tel:508-481-6200 • fax:508-481-7753 • http://www.accutest.com Note:This r;:pori is password Protected to disallow;.loci.€nu:nt modificationmodificationor assearbiy. ®®A�U 1 of 21 '["�S„�, A password to nrilock this report is available from your client service representative. __ _____ _.. Table of Contents _1- Section1: Sample Summary................................................................................................... 3 Section2: Case Narrative/Conformance Summary .............................................................. 4 Section 3: Sample Results —............. 3.1: M78854-1: 291C OAKLAND ROAD .......................................................................... 6 3. : M78854-2: 291D OAKLAND ROAD ......................................................................... 8 Section4: Misc. Forms ............................. .......................................:...................................... 14 4.1.: Chain of Custody ........................................................................................................... 11 4.2: RCP Form ...................................................................................................................... 12 4.3: Sample Tracking Chronicle ........................................................................................... 13 Section 5: GC/MS Volatiles C Data Summaries .............................................................. 14 5.1: Method Blank Summary ......................................................................._........................ 15 5.2: Blank Spike Summary ................................................................................................... 17 5.3: Duplicate Summary ....................................................................................................... 19 5.4: Surrogate Recovery Summaries ..................................................................................... 21 2of21 M7885a 1 Accutest Laboratories Sample Summary ExxonMobil Job No: M78854 GESCT:01-QQA 249 Oakland Rd., South Windsor CT Project No: PO#4509333735 WBS#08 Sample . Collected Matrix Client Number Date Time By Received Code Type Sample ID M78854-1 11/19/08 10:57 SEL 11/21/08 DW Drinking Water 291C OAKLAND ROAD M78854-2 11/19/08 11:12 SEL 11/21/08 DW Drinking Water 291D OAKLAND ROAD ® 3 of 21 UACCUTEST. M78854 L a bc) ra or . e SAMPLE DELIVERY GROUP CASE NARRATIVE Client: ExxonMobil Job No M78854 Site: GESCT:01-QQA 249Oakland Rd.,South Windsor CT Report Date 12/3/2008 10:36:11 AM 2 Sample(s)were collected on 11/19/2008 and were received at Accutest on 11/21/2008 properly preserved,at 2.4 Deg:C and intact. These Samples received an Accutest job number of M78854.A listing of the Laboratory Sample ID,Client_Sample ID and dates of collection are presented in the Results Summary Section of this report. Except as noted below,all method specified calibrations and quality control performance criteria were met for this job.For more information,please refer to QC summary pages. Volatiles by GCMS By Method EPA 524.2 REV 4.1 Matrix AQ Batch ID: MSR283 All samples were analyzed within the recommended method holding time. All method blanks for this batch meet method specific criteria. Sample(s) M78876-1DUP were used as the QC samples indicated. The Accutest Laboratories of New England certifies that all analysis were performed within method specification.It is further recommended that this report to be used in its entirety.The Accutest Laboratories of NE,Laboratory Director or assignee as verified by the signature on the cover page has authorized the release of this report(M78854). Wednesday,December 03,2008 Page I of 1 ® 4of21 M78854 Mel New England 6 40 Section IS ALL IN TWE CtItMISTRV Sample Results Report of Analysis ( 5f21 U M78854 Accutest Laboratories Report of Analysis Page I of 2 Client Sample ID: 291C OAKLAND ROAD Lab Sample ID: M78854-1 Date Sampled: 11/19/08 Matrix: DW-Drinking Water Date Received: 11/21/08 Method: EPA 524.2 REV 4.1 Percent Solids: n/a Project: GESCT:01-QQA 249 Oakland Rd., South Windsor CT File ID DF Analyzed By Prep Date Prep Batch Analytical Batch Run#1 R7363.D 1 11/27/08 AA n/a n/a MSR283 Run#2 Purge Volume Run#1 5.0 ml Run#2 VOA List CAS No. Compound Result MCL RL Units Q 71-43-2 Benzene ND 5.0 0.50 ug/1 108-86-1 Bromobenzene ND 0.50 ug/1 74-97-5 Bromochloromethane ND 0.50 ug/1 75-27-4 Bromodichloromethane ND 0.50 ug/i 75-25-2 Bromoform ND 0.50 ug/1 74-83-9 Bromomethane ND 0.50 ug/1 104-51-8 n-Butylbenzene ND 0.50 ug/1 135-98-8 sec-Butylbenzene ND 0.50 ug/1 98-06-6 tert-Butylbenzene ND 0.50 ug/l 108-90-7 Chlorobenzene ND 100 0.50 ug/1 75-00-3 Chloroethane ND 0.50 ug/1 67-66-3 Chloroform ND 0.50 ug/1 74-87-3 Chloromethane ND 0.50 ug/1 95-49-8 o-Chlorotoluene ND 0.50 ug/1 106-43-4 p-Chlorotoluene ND 0.50 ug/1 56-23-5 Carbon tetrachloride ND 5.0 0.50 ug/1 75-34-3 1,1-Dichloroethane ND 0.50 ug/1 75-35-4 1,1-Dichloroethylene ND 7.0 0.50 ug/1 563-58-6 1,1-Dichloropropene ND 0.50 ug/1 96-12-8 1,2-Dibromo-3-chloropropane ND 0.20 0.50 ug/1 106-93-4 1,2-Dibromoethane ND 0.050 0.50 ug/I 107-06-2 1,2-Dichloroethane ND 5.0 0.50 ug/I 78-87-5 1,2-Dichloropropane ND 5.0 0,50 ug/1 142-28-9 1,3-Dichloropropane ND 0.50 ug/1 594-20-7 2,2-Dichloropropane ND 0.50 ug/1 124-48-1 Dibromochloromethane ND 0.50 ug/I 74-95-3 Dibromomethane ND 0.50 ug/l 75-71-8 Dichlorodifluoromethane ND 0.50 ug/1 10061-01-5 cis-1,3-Dichloropropene ND 0.50 ug/1 541-73-1 m-Dichlorobenzene ND 0.50 ug/1 95-50-1 o-Dichlorobenzene ND 600 0.50 ug/I 106-46-7 p-Dichlorobenzene ND 75 0.50 ug/1 ND = Not detected j = Indicates an estimated value MCL = Maximum Contamination Level (40 CFR 141) B = Indicates analyte found in associated method blank E = Indicates value exceeds calibration range N = Indicates presumptive evidence of a compound 6of21 12ACCUTEST<` M78854 Accutest Laboratories Report of Analysis Page 2 of 2 Client Sample ID: 291C OAKLAND ROAD Lab Sample ID: M78854-1 Date Sampled: 11/19/08 Matrix: DW Drinking Water Date Received: 11/21/08 Method: EPA 524.2 REV 4.1 Percent Solids: n/a Project: GESCT:01-QQA 249 Oakland Rd., South Windsor CT VOA List CAS No. Compound Result MCL RL Units Q 156-60-5 trans-1,2-Dichloroethylene ND 100 0.50 ug/1 156-59-2 cis-1,2-Dichloroethylene ND 70 0.50 ug/1 10061-02-6 trans-1,3-Dichloropropene ND 0.50 ug/I 100-41-4 Ethylbenzene ND 700 0.50 ug/1 87-68-3 Hexachlorobutadiene ND 0.50 ug/I 98-82-8 Isopropylbenzene ND 0.50 ug/I 99-87-6 p-Isopropyltoluene ND 0.50 ug/I 75-09-2 Methylene chloride ND 5.0 0.50 ug/1 1634-04-4 Methyl Tert Butyl Ether ND 0.50 ug/1 91-20-3 Naphthalene ND 0.50 ug/1 103-65-1 n-Propylbenzene ND 0.50 ug/1 100-42-5 Styrene ND 100 0.50 ug/1 630-20-6 1,1,1,2-Tetrachloroethane ND 0.50 ug/1 71-55-6 1,1,1-Trichloroethane ND 200 0.50 ug/1 79-34-5 1,1,2,2-Tetrachloroethane ND 0.50 ug/1 79-00-5 1,1,2-Trichloroethane ND 5.0 0.50 ug/1 87-61-6 1,2,3-Trichlorobenzene ND 0.50 ug/1 96-18-4 1,2,3-Trichloropropane ND 0.50 ug/1 120-82-1 1,2,4-Trichlorobenzene ND 70 0.50 ug/1 95-63-6 1,2,4-Trimethylbenzene ND 0.50 ug/1 108-67-8 1,3,5-Trimethylbenzene ND 0.50 ug/1 127-18-4 Tetrachloroethylene ND 5.0 0.50 ug/1 108-88-3 Toluene ND 1000 0.50 ug/1 79-01-6 Trichloroethylene ND 5.0 0.50 ug/1 75-69-4 Trichlorofluoromethane ND 0.50 ug/1 75-01-4 Vinyl chloride ND 2.0 0.50 ug/1 m,p-Xylene ND 0.50 ug/1 95-47-6 o-Xylene ND 0.50 ug/1 1330-20-7 Xylenes (total) ND 10000 0.50 ug/1 CAS No. Surrogate Recoveries Run# 1 Run#2 Limits 2199-69-1 1,2-Dichlorobenzene-d4 104% 70-130% 460-00-4 4-Bromofluorobenzene 81% 70-130% ND = Not detected J = Indicates an estimated value MCL = Maximum Contamination Level (40 CFR 141) B = Indicates anaiyte found in associated method blank E = Indicates value exceeds calibration range N = Indicates presumptive evidence of a compound 7of21 ACC:UT F-ST M78854 Accutest Laboratories Report of Analysis Page i of 2 Client Sample ID: 291D OAKLAND ROAD Lab Sample ID: M78854-2 _ Date Sampled: 11/19/08 Matrix: DW-Drinking Water Date Received: 11/21/08 Method: EPA 524.2 REV 4.1 Percent Solids: n/a Project: GESCT:0I=QQA 249 Oakland Rd., South Windsor CT File ID DF Analyzed By Prep Date Prep Batch Analytical Batch Run#1 R7364.13 1 11/27/08 AA n/a n/a MSR283 Run#2 Purge Volume Run#1 5.0 ml Run#2 VOA List CAS No. Compound Result MCL RL Units Q 71-43-2 Benzene ND 5.0 0.50 ug/I - 108-86-1 Bromobenzene ND 0.50 ug/1 74-97-5 Bromochloromethane ND 0.50 ug/I 75-27-4 Bromodichloromethane ND 0.50 ug/1 75-25-2 Bromoform ND 0.50 ug/1 74-83-9 Bromomethane ND 0.50 ug/1 104-51-8 n-Butylbenzene ND 0.50 ug/1 135-98-8 sec-Butylbenzene ND 0.50 ug/1 98-06-6 tert-Butylbenzene ND 0.50 ug/I 108-90-7 Chlorobenzene ND 100 0.50 ug/1 75-00-3 Chloroethane ND 0.50 ug/1 67-66-3 Chloroform ND 0.50 ug/I 74-87-3 Chloromethane ND 0.50 ug/1 95-49-8 o-Chlorotoluene ND 0.50 ug/1 106-43-4 p-Chlorotoluene ND 0.50 ug/1 56-23-5 Carbon tetrachloride ND 5.0 0.50 ug/1 75-34-3 1,1-Dichloroethane ND 0.50 ug/l 75-35-4 1,1-Dichloroethylene ND 7.0 0.50 ug/1 563-58-6 1,1-Dichloropropene ND 0.50 ug/1 96-12-8 1,2-Dibromo-3-chloropropane ND 0.20 0.50 ug/l 106-93-4 1,2-Dibromoethane ND 0.050 0.50 ug/1 107-06-2 1,2-Dichloroethane ND 5.0 0.50 ug/I 78-87-5 1,2-Dichloropropane ND 5.0 0.50 ug/i 142-28-9 1,3-Dichloropropane ND 0.50 ug/1 594-20-7 2,2-Dichloropropane ND 0.50 ug/1 124-48-1 Dibromochloromethane ND 0.50 ug/1 74-95-3 Dibromomethane ND 0.50 ug/l 75-71-8 Dichlorodifluoromethane ND 0.50 ug/1 10061-01-5 cis-1,3-Dichloi\opropene ND 0.50 ug/l 541-73-1 m-Dichlorobenzene ND 0.50 ug/1 95-50-1 o-Dichlorobenzene ND 600 0.50 ug/1 106-46-7 p-Dichlorobenzene ND 75 0.50 ug/l ND = Not detected J = Indicates an estimated value MCL = Maximum Contamination Level (40 CFR 141) B = Indicates analyte found in associated method blank E = Indicates value exceeds calibration range N = Indicates presumptive evidence of a compound EJ 8of21 M78854 ' . . ........., Accutest Laboratories Report of Analysis Page 2 of 2 Client Sample ID: 291D OAKLAND ROAD Lab Sample ID: M78854-2 Date Sampled: 11/19/08 Matrix: DW-Drinking Water Date Received: 11/21/08 Method: EPA 524.2 REV 4.1 Percent Solids: n/a Project: GESCT:01-QQA 249 Oakland Rd., South Windsor CT VOA List CAS No. Compound Result MCL RL Units Q 156-60-5 trans-1,2-Dichloroethylene ND 100 0.50 ug/1 156-59-2 cis-1,2-Dichloroethylene ND 70 0.50 ug/I 10061-02-6 trans-1,3-Dichloropropene ND 0.50 ug/I 100-41-4 Ethylbenzene ND 700 0.50 ug/I 87-68-3 Hexachlorobutadiene ND 0.50 ug/1 98-82-8 Isopropylbenzene ND 0.50 ug/I 99-87-6 p-Isopropyltoluene ND 0.50 ug/1 75-09-2 Methylene chloride ND 5.0 0.50 ug/I 1634-04-4 Methyl Tert Butyl Ether ND 0.50 ug/I _ 91-20-3 Naphthalene ND 0.50 ug/1 103-65-1 n-Propylbenzene ND 0.50 ug/I 100-42-5 Styrene ND 100 0.50 ug/I 630-20-6 1,1,1,2-Tetrachloroethane ND 0.50 ug/I 71-55-6 1,1,1-Trichloroethane ND 200 0.50 ug/I 79-34-5 1,1,2,2-Tetrachloroethane ND 0.50 ug/I 79-00-5 1,1,2-Trichloroethane ND 5.0 0.50 ug/1 87-61-6 1,2,3-Trichlorobenzene ND 0.50 ug/1 96-18-4 1,2,3-Trichloropropane ND 0.50 ug/1 120-82-1 1,2,4-Trichlorobenzene ND 70 0.50 ug/I 95-63-6 1,2,4-Trimethylbenzene ND 0.50 ug/I 108-67-8 1,3,5-Trimethylbenzene ND 0.50 ug/I 127-18-4 Tetrachloroethylene ND 5.0 0.50 ug/I 108-88-3 Toluene ND 1000 0.50 ug/I 79-01-6 Trichloroethylene ND 5.0 0.50 ug/I 75-69-4 Trichlorofluoromethane ND 0.50 ug/I 75-01-4 Vinyl chloride ND 2.0 0.50 ug/I m,p-Xylene ND 0.50 ug/1 95-47-6 o-Xylene ND 0.50 ug/I 1330-20-7 Xylenes (total) ND 10000 0.50 ug/1 CAS No. Surrogate Recoveries Run# 1 Run# 2 Limits 2199-69-1 1,2-Dichlorobenzene-d4 107% 70-130% 460-00-4 4-Bromofluorobenzene 73% 70-130% ND = Not detected J = Indicates an estimated value MCL = Maximum Contamination Level (40 CFR 141) B = Indicates analyte found in associated method blank E = Indicates value exceeds calibration range N = Indicates presumptive evidence of a compound ® 9of21 -S T. M78854 New England Laa Section 4 Misc. Forms Custody Documents and Other Forms Includes the following where applicable: • Certification Exceptions • Certification Exceptions(CT). • Chain of Custody • RCP Form • Sample Tracking Chronicle 10 of 21 GACOJTEWC M78854 CHAIN OF CUSTODY 49S Tech Center West,Bldg.1 - Marlbo:n,MA 01752 732-329.0200 FAX:732-329-3499/3480 Aw dr # Chem/Re In Infomlation Facility Informatbn MONMOSIL CORPORATION-R lonal Laborato Program Northeast Anal al Imormetlon c—utanta CNNM y Nam. Froleol Name: Groundwater&E nvironrnental Services Inc.•WNE Mobii-S.Windsor#01-QQA Address stoat _ 425 B Ha den Statt col, awe zip 2 an Road 249 Oakland Road Windsor Connced seaicut 06095 - South Windsor CT .a PrgaalCmnN: EnMil Exxonmom comet: Bran He "a Scott Bushroe 8—Pis Conn et Phone/ale-2304388 r *r AP 80P i F}x# Loglbn la/ woo 0 800.220�119 aao-6ae-927a 04 PEa Po. 4509333735 urN# Accutest Collection Preservation Sample# Field ID/Point d Cdlet:flon oaa Tana 6a ad aamx bo I ea - ( 291C Oakland Road e� 2910 Oakland Road {� TMnrnaM rary 6odnees da Oea Oaysreae lntomlgon LJ aid 10 DMIneq Da ConxMnh/Ramatk6 Ya APPw.4 aY:rwai Commarcnl"A' FULL CLP a Day RU8f1 C9m...IAl"9' NYASPOn.90ryA Please follow RCP protocol for a GA groundwater ClaasRlcation 1t�$DAYRUSN NJRedue.d NYASPCat LJ `Bey e o 7Dry 6MERCENCY �NJ �also Fomq 2DayawmeaROY ❑Other E00 Fom L—- 4 L �J 1 Day EUMMENCY EmS0aw C---l-1•A••Resuhs Only n T/A data avallable VIA Labllnk 9amDia Cust9d must doe mentedb law each Bme samples charge askri,includ oa nris ot W 2 M. 9 w 5 • raw. 78854. Chain of Custody Page 1 of 1 } 11 of 2 MAC..tiC3UTESTe M7aa54 Reasonable Confidence Protocol Laboratory Analysis QA/QC Certification Form N Laboratory Name: Accutest New England Client: ExxonMobil GESCT:01-QQA 249 Project Location: Oakland Rd.,South Project Number: PO#4509333735 WBS#08 Windsor CT Sampling Date(s): 11/19/2008 Laboratory Sample ID(s): M78854-1,M78854-2 Methods: - EPA 524.2 REV 4.1 For each analytical method referenced in this laboratory report package, were all specified QA/QC performance criteria followed,including the requirement to 1 explain any criteria falling outside of acceptable guidelines,as specified in the Yes No t_ CTDEP method-specific Reasonable Confidence Protocol documents)? 1A Where all the method specified preservation and holding time requirements met? Yes No 1 B VPH and EPH mehods only: Was the VPH or EPH method conducted without Yes No r_ significant modifications (See section 11.3 of respective methods) NA 2 rv- Were all samples received by the laboratory in a condition consistent with yes No that described on the associated chain-of-custodydocument(s)? 3 Were samples received at an appropriate temperature(<6°C)? Yes I✓ No 4 Were all QA/QC performance criteria specified in the CTDEP Reasonable yes No f- Confidence Protocol documents achieved? 5 a)Were reporting limits specified or referenced on the chain-of-custody? Yes I✓ No b)Were these reporting limits met? Yes - No For each analytical method referenced in this laboratory report package, 6 were results reported for all constituents identified in the method-specific Yes No analyte lists presented in the Reasonable Confidence Protocol documents? Are project-specific matrix spikes and laboratory duplicates included in this 7 data set? Yes No i Note: For all questions to which the response was"No" (with the exception of question#7),additional information must be provided in an attached narrative. If the answer to question#1,#1A or#1B is"No", the data package does not meet the requirements for"Reasonable Confidence". I,the undersigned,attest under pains and penalties of perjury that,to the best of my knowledge and belief and based upon my personal inquiry of those responsible for providing the information contained in this analytical report,such information is accurate and complete. Authorized Signature: // 7_1-— Position: Lab Director Printed Name: Reza Tand Date: 12/3/2008 Accutest New England 12 of 21 M78854 Accutest Laboratories Internal Sample Tracking Chronicle w ExxonMobil GESCT:01-QQA 249 Oakland Rd., South Windsor CT Job No: M78854 Project No: PO#4509333735 WBS#08 Sample Number Method Analyzed By Prepped By Test Codes M H4 1 Collected: 19 N0,-08 T0:57 Y. SEL `Received 21°1VOU 08_By: 291C OAKLAND'ROAD M78854-1 EPA 524.2 REV 4.1 27-NOV-08 19:03 AA V524STD M78854-2 "Collected:"19 NOV=08`11:12 By: SEL Received 24-NOV-08 By: 29'1D OAKLANb ROAD M78854-2 EPA 524.2 REV 4.1 27-NOV-08 19:30 AA V524STD Page 1 of 1 13 of 21 UACC"a>k TEST. -- - M78854 . ..... _ New England • 3 „ Section ' `:IS ALE_ IN 7f4C � 4�1STftV' - - - - ... ... Ia-0 GC/MS Volatiles QC Data Summaries Includes the following where applicable: • Method Blank Summaries • Blank Spike Summaries • Matrix Spike and Duplicate Summaries • Surrogate Recovery Summaries 'j 14of21 MACCU'"T'F-8T. M78854 Method Blank Summary Page 1 of 2 Job Number: M78854 Account: MOBILSS ExxonMobil Project: GESCT:01-QQA 249 Oakland Rd., South Windsor CT Sample File ID DF Analyzed By Prep Date Prep Batch Analytical Batch MSR283-MB R7349.D 1 11/27/08 AA n/a n/a MSR283 The QC reported here.applies to the following samples: Method: EPA 524.2 REV 4.1 M78854-1, M78854-2 CAS No. Compound Result RL Units Q 71-43-2 Benzene ND 0.50 ug/1 108-86-1 Bromobenzene ND 0.50 ug/1 74-97-5 Bromochloromethane ND 0.50 ug/1 75-27-4 Bromodichloromethane ND 0.50 ug/1 75-25-2 Bromoform ND 0.50 ug/I 74-83-9 Bromomethane ND 0.50 ug/I 104-51-8 n-Butylbenzene ND 0.50 ug/I 135-98-8 sec-Butylbenzene ND 0.50 ug/1 98-06-6 tert-Butylbenzene ND 0.50 ug/1 108-90-7 Chlorobenzene ND 0.50 ug/I 75-00-3 Chloroethane ND 0.50 ug/I 67-66-3 Chloroform ND 0.50 ug/I 74-87-3 Chloromethane ND 0.50 ug/1 95-49-8 o-Chlorotoluene ND 0.50 ug/1 106-43-4 p-Chlorotoluene ND 0.50 ug/1 56-23-5 Carbon tetrachloride ND 0.50 ug/I 75-34-3 1,1-Dichloroethane ND 0.50 ug/I 75-35-4 i,l-Dichloroethylene ND 0.50 ug/I 563-58-6 1,1-Dichloropropene ND 0.50 ug/I 96-12-8 1,2-Dibromo-3-chloropropane ND 0.50 ug/1 106-93-4 1,2-Dibromoethane ND 0.50 ug/I 107-06-2 1,2-Dichloroethane ND 0.50 ug/1 78-87-5 1,2-Dichloropropane ND 0.50 ug/I 142-28-9 1,3-Dichloropropane ND 0.50 ug/1 594-20-7 2,2-Dichloropropane ND 0.50 ug/1 124-48-1 Dibromochloromethane ND 0.50 ug/1 74-95-3 Dibromomethane ND 0.50 ug/1 75-71-8 Dichlorodifluoromethane ND 0.50 ug/1 10061-01-5 cis-1,3-Dichloropropene . ND 0.50 ug/l 541-73-1 m-Dichlorobenzene ND 0.50 ug/1 95-50-1 o-Dichlorobenzene ND 0.50 ug/l 106-46-7 p-Dichlorobenzene ND 0.50 ug/1 156-60-5 trans-1,2-Dichloroethylene ND 0.50 ug/1 156-59-2 cis-1,2-Dichloroethylene ND 0.50 ug/1 10061-02-6 trans-1,3-Dichloropropene ND 0.50 ug/1 100-41-4 Ethylbenzene ND 0.50 ug/l 15 of 2'1 M78854 Method Blank Summary Page 2 of 2 Job Number: M78854 Account: MOBILSS ExxonMobil Project: GESCT:0I-QQA 249 Oakland Rd., South Windsor CT Sample File ID DF Analyzed By Prep Date Prep Batch Analytical Batch MSR283-MB R7349.D 1 11/27/08 AA n/a n/a MSR283 li t the following samples: Method: EPA 524.2 REV 4.1 The QC reported here applies o g s p M78854-1, M78854-2 CAS No. Compound Result RL Units Q 87-68-3 Hexachlorobutadiene ND 0.50 ug/1 98-82-8 Isopropylbenzene ND 0.50 ug/1 99-87-6 p-Isopropyltoluene ND 0.50 ug/1 75-09-2 Methylene chloride ND 0.50 ug/1 1634-04-4 Methyl Tert Butyl Ether ND 0.50 ug/1 91-20-3 Naphthalene ND 0.50 ug/l 103-65-1 n-Propylbenzene- ND 0.50 ug/l 100-42-5 Styrene ND 0.50 ug/1 630-20-6 1,1,1,2-Tetrachloroethane ND 0.50 ug/1 71-55-6 1,1,1-Trichloroethane ND 0.50 ug/1 79-34-5 1,1,2,2-Tetrachloroethane ND 0.50 ug/1 79-00-5 1,1,2-Trichloroethane ND 0.50 ug/1 87-61-6 1,2,3-Trichlorobenzene ND 0.50 ug/l 96-18-4 1,2,3-Trichloropropane ND 0.50 ug/1 120-82-1 1,2,4-Trichlorobenzene ND 0.50 ug/1 95-63-6 1,2,4-Trimethylbenzene ND 0.50 ug/I 108-67-8 1,3,5-Trimethylbenzene ND 0.50 ug/1 127-18-4 Tetrachloroethylene ND 0.50 ug/1 108-88-3 Toluene ND 0.50 ug/1 79-01-6 Trichloroethylene ND 0.50 ug/1 75-69-4 Trichlorofluoromethane ND 0.50 ug/1 75-01-4 Vinyl chloride ND 0.50 ug/1 m,p-Xylene ND 0.50 ug/l 95-47-6 o-Xylene ND 0.50 ug/1 1330-20-7 Xylenes (total) ND 0.50 ug/1 CAS No. Surrogate Recoveries Limits 2199-69-1 1,2-Dichlorobenzene-d4 112% 70-130% 460-00-4 4-Bromofluorobenzene 76% 70-130% CAS No. Tentatively Identified Compounds R.T. Est. Conc. Units Q Total TIC, Volatile 0 ug/I l 16 of 21 CI tJ'TIF-ST; M78854 - ,. -. Blank Spike Summary Page 1 of Job Number: M78854 Account: MOBILSS ExxonMobil Project: GESCT:01-QQA 249 Oakland Rd., South Windsor CT Sample File ID DF Analyzed By Prep Date Prep Batch Analytical Batch MSR283-BS R7347.1) 1 11/27/08 AA n/a n/a MSR283 €.n The QC reported here applies to the following samples: Method: EPA 524.2 REV 4.1 M78854-1, M78854-2 Spike BSP BSP CAS No. Compound ug/l ug/l % Limits 71-43-2 Benzene 5 4.6 92 70-130 108-86-1 Bromobenzene 5 4.7 94 70-130 74-97-5 Bromochloromethane 5 5.1 102 70-130 75-27-4 Bromodichloromethane 5 4.6 92 70-130 75-25-2 Bromoform 5 4.7 94 70-130. 74-83-9 Bromomethane 5 4.9 98 70-130 104-51-8 n-Butylbenzene 5 4.1 82 70-130 135-98-8 sec-Butylbenzene 5 4.3 86 70-130 98-06-6 tert-Butylbenzene 5 3.9 78 70-130 108-90-7 Chlorobenzene 5 4.5 90 70-130 75-00-3 Chloroethane 5 4.2 84 70-130 67-66-3 Chloroform 5 4.3 86 70-130 74-87-3 Chloromethane 5 4.1 82 70-130 95-49-8 o-Chlorotoluene 5 4.4 88 70-130 106-43-4 p-Chlorotoluene 5 4.5 90 70-130 56-23-5 Carbon tetrachloride 5 4.5 90 70-130 75-34-3 1,1-Dichloroethane 5 4.4 88 70-130 75-35-4 1,1-Dichloroethylene 5 4.1 82 70-130 563-58-6 1,1-Dichloropropene 5 3.9 78 70-130 96-12-8 1,2-Dibromo-3-chloropropane 5 6.0 120 70-130 106-93-4 1,2-Dibromoethane 5 5.0 100 70-130 107-06-2 1,2-Dichloroethane 5 4.9 98 70-130 78-87-5 1,2-Dichloropropane 5 4.4 88 70-130 142-28-9 1,3-Dichloropropane 5 5.1 102 70-130 594-20-7 2,2-Dichloropropane 5 4.5 90 70-130 124-48-1 Dibromochloromethane 5 4.8 96 70-130 74-95-3 Dibromomethane 5 5.0 100 70-130 75-71-8 Dichlorodifluoromethane 5 3.9 78 70-130 10061-01-5 cis-1,3-Dichloropropene 5 4.4 88 70-130 541-73-1 m-Dichlorobenzene 5 4.8 96 70-130 95-50-1 o-Dichlorobenzene 5 4.8 96 70-130 106-46-7 p-Dichlorobenzene 5 4.9 98 70-130 156-60-5 trans-1,2-Dichloroethylene 5 4.1 82 70-130 156-59-2 cis-1,2-Dichloroethylene 5 4.4 88 70-130 10061-02-6 trans-1,3-Dichloropropene 5 4.7 94 70-130 100-41-4 Ethylbenzene 5 3.9 78 70-130 ® 17 of 2 M78854 Blank Spike Summary Page 2 of 2 Job Number: M78854 Account: MOBILSS ExxonMobil Project: GESCT:01-QQA 249 Oakland Rd., South Windsor CT Sample File ID DF Analyzed By Prep Date Prep Batch Analytical Batch MSR283-BS R7347.1) 1 11/27/08 AA n/a n/a MSR283 cis The C reported here applies to the followin samples: Method: EPA 524.2 REV 4.1 Q p pp � p M78854-1, M78854-2 Spike BSP BSP CAS No. Compound ug/l ug/l % Limits 87-68-3 Hexachlorobutadiene 5 5.0 100 70-130 98-82-8 Isopropylbenzene 5 3.6 72 70-130 99-87-6 p-Isopropyltoluene 5 4.0 80 70-130 75-09-2 Methylene chloride 5 4.7 94 70-130 1634-04-4 Methyl Tert Butyl Ether 5 4.4 88 70-130 91-20-3 Naphthalene 5 5.2 104 70-130 103-65-1 n-Propylbenzene 5 4.0 80 70-130 100-42-5 Styrene 5 3.5 70 70-130 630-20-6 1,1,1,2-Tetrachloroethane 5 4.9 98 70-130 71-55-6 1,1,1-Trichloroethane 5 4.4 88 70-130 79-34-5 1,1,2,2-Tetrachloroethane 5 5.5 110 70-130 79-00-5 1,1,2-Trichloroethane 5 5.2 104 70-130 87-61-6 1,2,3-Trichlorobenzene 5 5.3 106 70-130 96-18-4 1,2,3-Trichloropropane 5 4.8 96 70-130 120-82-1 1,2,4-Trichlorobenzene 5 4.9 98 70-130 95-63-6 1,2,4-Trimethylbenzene 5 4.0 80 70-130 108-67-8 1,3,5-Trimethylbenzene 5 4.1 82 70-130 127-18-4 Tetrachloroethylene 5 4.6 92 70-130 108-88-3 Toluene 5 4.1 82 70-130 79-01-6 Trichloroethylene 5 4.3 86 70-130 75-69-4 Trichlorofluoromethane 5 4.4 88 70-130 75-01-4 Vinyl chloride 5 3.9 78 70-130 m,p-Xylene 10 8.4 84 70-130 95-47-6 o-Xylene 5 4.4 88 70-130 1330-20-7 Xylenes (total) 15 12.7 85 70-130 CAS No. Surrogate Recoveries BSP Limits 2199-69-1 1,2-Dichlorobenzene-d4 107% 70-130% 460-00-4 4-Bromofluorobenzene 99% 70-130% 18 of 21 M78854 Duplicate Summary Page 1 of Job Number: M78854 Account: MOBILSS ExxonMobil Project: GESCT:01-QQA 249 Oakland Rd., South Windsor CT Sample File ID DF Analyzed By Prep Date Prep Batch Analytical Batch M78876-1DUP R7353.13 1 11/27/08 AA n/a n/a MSR283 M78876-1 R7352.1) 1 11/27/08 AA n/a n/a MSR283 The QC reported here applies to the following samples: Method: EPA 524.2 REV 4.1 M78854-1, M78854-2 M78876-1 DUP CAS No. Compound ug/1 Q ug/I Q RPD Limits 71-43-2 Benzene ND ND nc 30 108-86-1 Bromobenzene ND ND nc 30 74-97-5 Bromochloromethane ND ND nc 30 75-27-4 Bromodichloromethane ND ND nc 30 75-25-2 Bromoform ND ND nc 30 74-83-9 Bromomethane ND ND nc ` 30 104-51-8 n-Butylbenzene ND ND nc 30 135-98-8 sec-Butylbenzene ND ND nc 30 98-06-6 tert-Butylbenzene ND ND nc 30 108-90-7 Chlorobenzene ND ND nc 30 75-00-3 Chloroethane ND ND nc 30 67-66-3 Chloroform 0.63 0.66 5 30 74-87-3 Chloromethane ND ND nc 30 95-49-8 o-Chlorotoluene ND ND nc 30 106-43-4 p-Chlorotoluene ND ND nc 30 56-23-5 Carbon tetrachloride ND ND nc 30 75-34-3 1,1-Dichloroethane ND ND nc 30 75-35-4 1,1-Dichloroethylene ND ND nc 30 563-58-6 1,1-Dichloropropene ND ND nc 30 96-12-8 1,2-Dibromo-3-chloropropane ND ND nc 30 106-93-4 1,2-Dibromoethane ND ND nc 30 107-06-2 1,2-Dichloroethane ND ND nc 30 78-87-5 1,2-Dichloropropane ND ND nc 30 142-28-9 1,3-Dichloropropane ND ND nc 30 594-20-7 2,2-Dichloropropane ND ND nc 30 124-48-1 Dibromochloromethane ND ND nc 30 74-95-3 Dibromomethane ND ND nc 30 75-71-8 Dichlorodifluoromethane ND ND nc 30 10061-01-5 cis-1,3-Dichloropropene ND ND nc 30 541-73-1 m-Dichlorobenzene ND ND nc 30 95-50-1 o-Dichlorobenzene ND ND nc 30 106-46-7 p-Dichlorobenzene ND ND nc 30 156-60-5 trans-1,2-Dichloroethylene ND ND nc 30 156-59-2 cis-1,2-Dichloroethylene ND ND nc 30 10061-02-6 trans-1,3-Dichloropropene ND ND nc 30 100-41-4 Etylbenzene ND ND nc 30 19 of 2 --- M7885M1 •. ._....._, Duplicate Summary Page z of Job Number: M78854 Account: MOBILSS ExxonMobil Project: GESCT:01-QQA 249 Oakland Rd., South Windsor CT Sample File ID DF Analyzed By Prep Date Prep Batch Analytical Batch M78876-1DUP R7353.1) 1 11/27/08 AA n/a n/a MSR283 M78876-1 R7352.1) 1 11/27/08 AA n/a n/a MSR283 The QC reported here applies to the following samples: Method: EPA 524.2 REV 4.1 M78854-1, M78854-2 M78876-1 DUP CAS No. Compound ug/1 Q ug/l Q RPD Limits -87-68-3 Hexachlorobutadiene ND NO nc 30 98-82-8 Isopropylbenzene ND ND nc 30 99-87-6 p-Isopropyltoluene ND ND nc 30 75-09-2 Methylene chloride ND ND nc. 30 1634-04-4 Methyl Tert Butyl Ether ND ND nc 30 91=20-3 Naphthalene ND ND nc 30 103-65-1 n-Propylbenzene ND ND nc 30 100-42-5 Styrene ND ND nc, . 30 630-20-6 1,1,1,2-Tetrachloroethane ND ND nc 30 71-55-6 1,1,1-Trichloroethane ND ND nc 30 79-34-5 1,1,2,2-Tetrachloroethane ND NO nc 30 79-00-5 1,1,2-Trichloroethane ND ND nc 30 87-61-6 1,2,3-Trichlorobenzene ND ND nc 30 96-18-4 1,2,3-Trichloropropane ND ND nc 30 120-82-1 1,2,4-Trichlorobenzene ND NO nc 30 95-63-6 1,2,4-Trimethylbenzene ND ND nc 30 108-67-8 1,3,5-Trimethylbenzene ND ND nc 30 127-18-4 Tetrachloroethylene ND ND nc 30 108-88-3 Toluene ND ND nc '30 79-01-6 Trichloroethylene ND ND nc 30 75-69-4 Trichlorofluoromethane ND ND nc 30 75-01-4 Vinyl chloride ND ND nc 30 m,p-Xylene ND ND nc 30 95-47-6 o-Xylene ND ND nc 30 1330-20-7 Xylenes (total) ND ND nc 30 CAS No. Surrogate Recoveries DUP M78876-1 Limits 2199-69-1 1,2-Dichlorobenzene-d4 106% 102% 70-130% 460-00-4 4-Bromofluorobenzene 84% 86% 70-130% 20 of 21 IJACICUTESM M78854 Volatile Surrogate Recovery Summary Page I of I Job Number: M78854 Account: MOBILSS ExxonMobil Project: GESCT:01-QQA 249 Oakland Rd., South Windsor CT Method: EPA 524.2 REV 4.1 Matrix: AQ Samples and QC shown here apply to the above method Lab Lab Sample ID File ID SI S2 M78854-1 R7363.1) 104.0 81.0 M78854-2 R7364.1) 107.0 73.0 _ M78876-1DUP R7353.1) 106.0 84.0 MSR283-BS R7347.D 107.0 99.0 MSR283-MB R7349.D 112.0 76.0 Surrogate Recovery Compounds Limits S1 = 1,2-Dichlorobenzene-d4 70-130% S2 = 4-Bromofluorobenzene 70-130% 21 of 21 M7885k