Loading...
HomeMy WebLinkAboutWell Inspection 00 PRat-MIX EnWaumnu Labom ,Inc. -687 East Mk4aTurnpike, Ra Boat 416,Manchester,Cr 06040 Ted,{8601645.1102 Fax(860)645-CM Analysis Report FOR: Attn: Mr.Joel Rees Fuss&O'Neill,Inc. March 05,2001 146 Hartford Rd. Manchester,CT 06040 Sample Information Custody Information Date Time Matrix: WATER Collected by: 03/01/01 12:50 Location Code: F&O Received by: SW 03/01/01 17:40 Project Code: Analyzed by: see below P.O.#: 00301A10 Laboratory Data Client ID: S WINDSOR 609010301-25 Phoenix I.D. AD17236 Parameter Result RL Units Date Time by Reference Volatiles 1,1,1,2-Tetrachloroethane ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 1,1,1-Trichloroethane ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 1,1,2,2-Tetrachloroethane ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 1,1,2-Trichloroethane ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 1,1-Dichlorethene ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 1,1-Dichloroethane ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 1,1-Dichloropropene ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 1,2,3-Trichlorobenzene ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 1,2,3-Trichloropropane ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 1,2,4-Trichlorobenzene ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 1,2,4-Trimethylbenzene ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 1,2-Dibromo-3-chloropropane ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 1,2-Dibromoethane ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 1,2-Dichlorobenzene ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 1,2-Dichloroethane ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 1,2-Dichloropropane ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 1,3,5-Trimethylbenzene ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 1,3-Dichlorobenzene ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 1,3-Dichloropropane ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 Client ID: S WINDSOR 609010301-25 Phoenix I.D. AD17236 Parameter Result RL Units Date Time by Reference 1,4-Dichlorobenzene ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 2,2-Dichloropropane ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 2-Butanone ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 2-Chlorotoluene ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 4-Chlorotoluene ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 4-Isopropyltoluene ND 0.5 - ug/L 03/02/O1 8:06 R/P 524.2 Benzene ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 Bromobenzene ND 0.5 ug/L 03/02/O1 8:06 R/P 524.2 Bromochloromethane ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 Bromodichloromethane ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 Bromoform ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 Bromomethane ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 Carbon Tetrachloride ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 Chlorobenzene ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 Chloroethane ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 Chloroform ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 Chloromethane ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 cis-1,2-Dichloroethene ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 cis-1,3-Dichloropropene ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 Dibromochloromethane ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 Dibromomethane ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 Dichlorodifluoromethane ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 Ethylbenzene ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 Hexachlorobutadiene ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 Isopropylbenzene ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 Methyl Tert Butyl Ether ND 1.0 ug/L 03/02/01 8:06 R/P 524.2 Methylene Chloride ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 n-Butylbenzene ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 Napthalene ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 o-Xylene ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 p-and m-Xylene ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 Propylbenzene ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 sec-Butylbenzene ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 Styrene ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 tert-Butylbenzene ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 Tetrachloroethylene ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 Client ID: S WINDSOR 609010301-25 Phoenix I.D. AD17236 Parameter Result RL Units Date Time by Reference Toluene ND 0.5 ug/L 03/02/O1 8:06 R/P 524.2 Total Trihalomethanes(TTHM) - ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 trans-1,2-Dichloroethene ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 trans-1,3-Dichloropropene ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 Trichloroethylene ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 Trichlorofluoromethane ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 Vinyl Chloride ND 0.5 ug/L 03/02/01 8:06 R/P 524.2 %4-Bromofluorobenzene(Surrogate) 98 % 03/02/01 8:06 R/P 524.2 Comments: ND=Not detected BDL=Below Detection Limit RL=Reporting Limit TRIP BLANK INCLUDED. If there are any questions regarding this data,please call Phoenix Client Services at extension 200. Phyllis Shiller,Laboratory Director March 05,2001 RHO' %............. En*y'11'1" ntoI Labomtor'in k1r, 597 East MIddie Tutnpiks, P O.Box M a.m-chemer,cT 96w Tel.{81)8�i5.1102 Fax(9so)64MB23 QC Report AD17239 March 05,2001 Sample ID AD17239 Analysis: Volatiles (MS) Analysis QC AD17239 Matrix Matrix Relative Spike Spike %Diff Dup (%D) Analyte (Rec) (%Rec) ---------------------------------------------------- Benzene 78% 74% 5% Chlorobenzene 104% 98% 6% 1,1-Dichloroethylene 88% 72% 20% Toluene 84% 71% 17% Trichloroethylene 96% 78% 21% No analytes were detected in the applicable method blanks above the stated detection limits with the following exceptions: (NONE) If there are any questions regarding this data,please call Phoenix Client Services at extension 200. 6 J Phyllis Shiller Laboratory Director FUSS&O'NEILL,INC. FUSS&U'Neill Inc. 146 HARTFORD ROAD consulting engineers CHAIN-OF-CUSTODY RECORD MANCHESTER,CT 06040 Environmental Field Services .re 045951 (860) 646-2469 PROJECT NAME PROJECT LOCATION PROJECT NUMBER LABORATORY i REPORT TO: t 1 z. Source Codes: B=Bottom Sediment L=Lake/Pond/Ocean LF=Landfill MW=Monitor Well O=Outfall PW=Potable Water R=River/Stream INVOICE TO: i _ i :::. RO=Run Off S=Soil SG=Sludge ST=Septic Tank P.O.#: T=Treatment Facility W=Well X=Other,Specify ITEM SOURCE CONTAINER TRANSFER NUMBER NUMBER SAMPLE NUMBER ANALYSIS REQUIRED y� CODE COMMENTS 8 CHECK NO. TYPE SIZE PRESERV � 1 2 3 4 V 1 Ae 1717/1 r i.! .4 Container Code: P=Plastic V=VOA Vial C=Cube G=Glass A=Amber Glass T=Teflon Lid B=Bacteria Bottle Preservative Code: I=Iced F=Filtered N=Nitric Acid [HNO3] H=Hydrochloric Acid[HCI] S=Sodium Hydroxide[NaOH] T=Sodium Thiosulfate[Na2S203] B=Sodium Bisulfate[NaHSO41 O=Sulfuric Acid [H2SO4] A=Ascorbic Acid[C61-1806] X=Other,Specify Sampler's Signature Affiliation Date Time TRANSFER ITEM TRANSFERS ACCEPTED BY DATE TIME } NUMBER NUMBER RELINQUISHED BY 3 ADDITIONAL COMMENTS: � L 2 r 3 d FUSS&O'NE ILL,INC. Fuss&O ►Neill Inc. >' 146 HARTFORD ROAD consulting engineers CHAIN-OF-CUSTODY RECORD MANCHESTER,cT06040 Environmental Field Services ,0 045952 (860) 646-2469 PROJECT NAME PROJECT LOCATION PROJECT NUMBER LABORATORY I REPORT TO: Source Codes: B=Bottom Sediment L=Lake/Pond/Ocean LF=Landfill MW=Monitor Well O=Outfall PW=Potable Water R=River/Stream INVOICE TO: RO=Run Off S=Soil SG=Sludge ST=Septic Tank T=Treatment Facility W=Well P.0.#: X=Other,Specify ITEM SOURCE CONTAINER TRANSFER NUMBER NUMBER SAMPLE NUMBER CODE ANALYSIS REQUIRED COMMENTS &CHECK NO. TYPE SIZE PRESERV. 1 /" 2 3 4 ter, Container Code: P=Plastic V=VOA Vial C=Cube G=Glass A=Amber Glass T=Teflon Lid B=Bacteria Bottle Preservative Code: I=Iced F=Filtered N=Nitric Acid [HNO3] H=Hydrochloric Acid[HCII S=Sodium Hydroxide[NaOH] T=Sodium Thiosulfate[Na2S203] 'A B=Sodium Bisulfate[NaHSO41 O=Sulfuric Acid [H2SO4] A=Ascorbic Acid[C61­1806] X=Other,Specify Sampter's Signature Affiliation Date Time TRANSFER ITEM TRANSFERS ACCEPTED BY DATE TIME NUMBER NUMBER RELINQUISHED BY ADDITIONAL COMMENTS: I 2 m. ,.s .�...o.-•... • n .., •',.'1 � i. 1.� 00 FUSS&O'NEILL,INC. Fuss&O'Neill Inc. 146 HARTFORD ROAD COnsulting engineers MANCHESTER,CT 06040 CHAIN-OF-CUSTODY RECORD . 04-5953 (860) 646-2469 Environmental Field services PROJECT NAME PROJECT LOCATION PROJECT NUMBER LABORATORY REPORT TO:,t : I Source Codes: B=Bottom Sediment L=Lake/Pond/Ocean LF=Landfill r,, MW=Monitor Well O=Outfall PW=Potable Water R=River/Stream I INVOICE TO: i , ti RO=Run Off S=Soil SG=Sludge ST=Septic Tank T=Treatment Facility W=Well P.0.#: .,X='Other,Specify I., ITEM v SOURCE CONTAINER TRANSFER NUMBER NUMBER SAMPLE NUMBER CODE ANALYSIS REQUIRED COMMENTS 8 CHECK NO. TYPE SIZE PRESERV. 1 2 3 4 i A) rT ..............L-------j Container Code: P=Plastic i V=VOA Vial C=Cube G=Glass A=Amber Glass T=Teflon Lid B=Bacteria Bottle Preservative Code: I=Iced F=Filtered N=Nitric Acid [HNO3] H=Hydrochloric Acid[HCI] S=Sodium Hydroxide[NaOH] T=Sodium Thiosulfate[Na2S203] B=Sodium Bisulfate[NaHSO41 O=Sulfuric Acid [HZS04] A=Ascorbic Acid[C61­1806] X=Other,Specify Sampler's Signature Affiliation Date Time TRANSFER 'ITEM TRANSFERS ACCEPTED BY DATE TIME NUMBER NUMBER RELINQUISHED B ; ADDITIONAL COMMENTS: 3 t