Loading...
HomeMy WebLinkAboutSchool Correspondence 00 Z 0 MANSFZELD OFFZCE c 44 CODFISH LANE 31 BRZARCLZFF ROAD W WESTON, CONNECTICUT 06883 BROOKS U. 203-226-6970 MANSFZELD CENTER, CT 06250 V1 CT WATS 1-800-843-1631 (203)456-3956 January 16 , 1990 Mr. Patrick T. Hankard Director of Building Maintenance South Windsor Public Schools 1737 Main Street South Windsor, CT 06074 Dear Mr. Hankard: The results of recent radon testing in the South Windsor school buildings are enclosed. You will find one or more pages for each building presented in a format suitable for posting . Radon-in-air samples were collected following protocols suggested by the U.S. Environmental Protection Agency (EPA) in their publication "Radon Measurements in Schools, An Interim Report" , March 1989 . Charcoal samplers, manufactured and analyzed by Air-Chek, 180 Glenbridge Road, Arden, NC 28704, were placed in classrooms and other frequently used rooms on and below ground level . The results provide a "background" survey which can be used to indicate whether a potential problem exists. As you review the survey, keep in mind that the EPA protocols are just guidelines at this time. While the Connecticut State Department of Education recommends that schools be tested, neither state nor federal regulations have been developed to require schools to be evaluated for radon and mitigated as is the case for asbestos. Also, the screening measurement does not represent the long-term average radon level to which school children and teachers are exposed. If elevated levels are found with a screening measurement, there are two important reasons why no funds should be expended to reduce radon levels before making confirmatory or diagnostic measurements. First, there is always the possibility that a single measurement may be faulty. Second, radon levels fluctuate so greatly that a single measurement may be made during an unusual peak in the radon concentration. Making a second measurement will better assess the levels to which students are routinely exposed. The EPA standard for radon-in-air is 4 pCi/L. The EPA currently feels that no further action is indicated when results this low are obtained. Although exposures in this range do present some risk of lung cancer, no remedial measures are recommended since reduction of levels this low may be impossible to achieve. According to the EPA, 4 pCi/L is equivalent to a HYGIENE & SAFETY SERVICES little more than 200 chest x-rays per year and would result in between 1 and 5 lungcancer deaths per 100 people exposed over-a 70 year period. The Congress has set a national goal for indoor radon concentrations to match outdoor ambient levels (0. 2 to 0. 7 pCi/L) • The current EPA recommended actions, based on results of screening measurements, are as follows: Screening Measurement Result Recommended Action less than 4.0 pCi/L Follow-up measurements are probably not needed, but may be made at the discretion of school officials. When using short-term measurements, average radon concentrations can vary by a factor of 2 or 3. The possibility of reducing radon levels must be evaluated on a case-by-case basis. between 4 and 20 pCi/L Perform long-term follow-up measurements over the next 12 months. If confirmed, action should be taken within several months to reduce radon levels as far as possible. between 20 and 100 pCi/L Perform short-term follow-up measurements within several months. If confirmed, action should be taken within several weeks to reduce radon levels as far as possible. over 100 pCi/L Perform short-term follow-up measurements immediately. Contact the appropriate state or local health officials to determine if temporary relocation is needed until the radon level can be reduced. Based on the above recommendations, no further action is needed at this time. All of the measured radon levels were below 4.0 pCi/L. You will find three sample numbers missing from the reports. Sample 6 from Ellsworth was reported as improperly sealed. Air infiltration invalidated the test. " Samples 12 and 14 from Timothy Edwards were eliminated from the list because the laboratory shipment contained only 248 kits rather than the 250 ordered. Please do not hesitate to call if you have any questions. Sincerely yours, 7 Mark F. Granville Consultant enclosures Z [1"1 RADCQN SURVEY 44 CODFISH LANE w WESTON, CONNECTICUT 06883 BROOKS ¢ 203-226-6970 ELI TERRY ELEMENTARY SCHOOL in CT WATS 1-800-843-1631 South Windsor, Connecticut RADON-IN-AIR Tested 12129189 - 112190 SAMPLE ROOM NUMBER ROOM USE pcilL 1 1 classroom 1 . 6 2 2 classroom 1 . 7 3 3 classroom 1 . 8 4 4 classroom 1 . 7 5 5 classroom 2 . 5 6 6 classroom 1 . 8 7 7 classroom 2 .4 8 8 classroom 1 . 9 9 9 classroom 1 . 7 10 10 classroom 1 . 9 11 11 classroom 2 . 8 12 12 classroom 2 . 2 13 13 classroom 2 . 1 14 14 classroom 1 .4 15 15 classroom 0 . 7 16 16 classroom 1 . 7 17 17 classroom 1 . 8 18 18 classroom 1 . 6 19 19 classroom 1 . 6 20 20 classroom 2 . 1 HYGIENE & SAFETY SERVICES SAMPLE ROOM NUMBER ROOM USE PCi1L 21 21 classroom 1 . 6 22 22 classroom 2. 1 23 23 classroom 1 . 6 24 24 classroom 1 . 9 25 25 classroom 1 . 7 26 26 classroom 2. 0 27 27 classroom 1 . 7 28 faculty lounge 1 .8 29 principal ' s office 0.8 30 main office/ health 2 .0 31 library 1 . 6 32 cafeteria 1 .4 33 cafeteria 1 . 3 34 kitchen 1 . 3 35 gymnasium 1 . 6 36 gymnasium 1 .8 37 custodial office 1 . 8 Radon Survey Eli Terry page 2 LLI 1Lkkr E.Llt•BIAH SCHOOL South Windsor, Connecticut _ LOCATION OF RADON SAMPLES December 29, 1989 •lo r9 •g •b •� •s. L — .L � C T e s •'1 •S •3 • l s • �U cAFETERIA ;i 33 •13 L :' '� r _ 8 S7A�E 1 •sl 1 •tj •>�i •� s L — — � 36 T �— �s & I GYMNAS��M L off •Iq •yo •,I. ,LJ ,1 L KEY ADM administrative office,. FAC faculty room N B,G boy,girl lavatory L,M women,men lavatory S supplies H nurse J custodial G Z 0 ad 44 CODFISH LANE RADON S U R V E Y W WESTON, CONNECTICUT 06883 BROOKS ¢ 203-226 ss7o kA CT WATS 1-800-843-1631 ELLSWORTH MEMORIAL BUILDING South Windsor, Connecticut RADON-IN-AIR Tested: 12129189 - 112190 SAMPLE ROOM NUMBER ROOM USE PCiA 1 100 office < , 3 2 101 lounge < . 3 3 102/102A photocopy/supplies 0. 5 4 104 0 .8 5 106 music/reading < . 3 7 maintenance < . 3 8 maintenance < . 3 9 maintenance < . 3 10 gymnasium 0 . 3 11 gymnasium 0 . 3 HYGIENE & SAFETY SERVICES ELLSWORTH MEMORIAL BUILDING South Windsor, Connecticut LOCATION OF RADON SAMPLES December 29, 1989 UPPER L LEVEL M L MIDDLE LEVEL KEY: L,M Momen,men lavoratory ' S supplies M J custodial �s LOWER F�YMNASIOMI yLEVEL SfAbE I L hlll q I ' g a .Z� n Z 0 o� 44 CODFISH LANE RA D O N S U R V E Y W WESTON, CONNECTICUT 06883 BROOKS ¢ 203-226-6970 to CTWATS I-800-843-1631 ORCHARD HILL ELEMENTARY SCHOOL South Windsor, Connecticut RADON-IN-AIR Tested: 12129189 - 112190 SAMPLE ROOM NUMBER ROOM USE pCiA 1 1 classroom 1 .4 2 2 classroom 1 .4 3 3 classroom 2 . 3 4 4 classroom 2 . 2 5 5 classroom 3 . 1 6 6 classroom 2 . 0 7 7 classroom 2 . 2 8 8 classroom 1. 4 9 17 classroom 1 . 0 10 18 classroom 1 . 6 11 19 classroom 1 . 3 12 20 classroom 1 . 3 13 21 classroom 1 .0 14 22 classroom 1 . 5 15 23 classroom 1 .3 16 24 classroom 0 . 8 17 social worker 0 . 3 18 gymnasium 1 . 6 19 gymnasium 1 . 6 20 main office 0 . 9 HYGIENE & SAFETY SERVICES SAMPLE ROOM NUMBER ROOM USE PCVL 21 health room 1 . 3 22 classroom 1 . 7 23 reading room 1 . 7 24 workroom 1 . 6 25 custodial office 0 . 9 26 kitchen 0. 9 27 cafeteria 0 . 7 28 cafeteria 0. 6 Radon Survey Orchard Hill page 2 L ORCHARD HILL ELEMENTARY SCHOOL _ South Windsor, Connecticut LOCATION OF RADON SAMPLES December 29, 1989 GTMNAS1uM LOWER • tp r--. LEVEL 6 e •4 6$0 off IL STAGE M UPPER LEVEL — T T y 6 N. KEY: ADM administrative offices FAC faculty room WK1 faculty work room f,L, ooy,girl lavatory h nurse 7O N. mcchanical u cu,.todial 15., • • S CAFETERIA I 6 9 �8 •� �(, _ air 27 � ea�aR •i •Z •3 •Y KITCHEN ic I � J �1 N 0 Z 0 06 44 CODFISH LANE RA D C)N S U R V E Y W WESTON, CONNECTICUT 06883 BROOKS ¢ 203 22s ss7o to CT WATS 1-800-843-1631 PLEASANT VALLEY ELEMENTARY SCHOOL South Windsor, Connecticut RADON-IN-AIR Tested: 12129189 - 112190 SAMPLE ROOM NUMBER ROOM USE Ci L 1 1 classroom 0 . 3 2 2 classroom 0 .4 3 3 classroom 0. 7 4 4 classroom 0 . 5 5 5 classroom 0 . 3 6 6 classroom 0 . 3 7 7 classroom 0. 3 8 8 classroom < . 3 9 9 classroom 0 . 3 10 10 classroom 0 . 3 11 11 classroom 0. 3 12 12 classroom < . 3 13 13 classroom 0 . 6 14 14 classroom 0.4 15 15 classroom 0 . 5 16 16 classroom < . 3 17 17 classroom 0. 3 18 20 classroom 0 . 5 19 21 classroom 0.4 20 22 classroom 0 .6 HYGIENE & SAFETY SERVICES SAMPLE ROOM NUMBER ROOM USE Ci L 21 23 classroom 0 . 4 22 24 classroom 0. 3 23 25 classroom 0. 5 24 26 classroom 0 .8 25 27 classroom 0 .9 26 18 reading room 0 .4 27 19 library 0 .4 28 main office 0. 3 29 health room 0 . 3 30 kitchen < . 3 31 cafeteria < . 3 32 gymnasium < . 3 33 gymnasium 0 .4 34 custodial office 0.4 Radon Survey Pleasant Valley page 2 PLEASANT. VALLEY ELEMENTARY SCHOOL South Windsor. Connecticut I LOCATION OF RADON SAMPLES December 29, 1989 q1. yt so • 7 • �3 r • �y • 1Z • tf • Hr l0 Le o1�E R 6 i3L • •7 T� 3i 9 r ;v 5 1 II LACE j L KITUI • • a • l7 L„ r07 33 GYMIJASfUM • tY 3 • j KEY: ADM administrative offices B,G boy,girl lavoratory H nurse S supplies J custodial N G Z O H 44 CODFISH LANE WWESTON, CONNECTICUT 06883 Fit A D C�I'llS U R V E Y BROOKS ¢ 203 22s ss7o LA CT WATS 1-800-843-1631 PHILLIP SMITH ELEMENTARY SCHOOL South Windsor, Connecticut RADON-IN-AIR Tested: 12129189 - 112190 SAMPLE ROOM NUMBER ROOM USE pcilL 1 1 classroom 0 . 5 2 2 classroom 0 .4 3 3 classroom 0 . 7 4 4 classroom 0 . 7 5 5 classroom 0. 5 6 6 classroom 0 .6 7 7 classroom 0 .4 8 8 classroom 0 .4 9 9 classroom 0. 5 10 10 classroom 0 .4 11 11 classroom 0 . 9 12 12 classroom 0.8 13 13 classroom 0.8 14 14 classroom 0 . 9 15 15 classroom 0 . 7 16 16 classroom 0. 7 17 17 classroom 0 . 5 18 18 classroom 0 .4 19 19 classroom 0 . 4 20 20 classroom 0. 5 HYGIENE & SAFETY SERVICES SAMPLE ROOM NUMBER ROOM USE Ci L 21 21 classroom 0. 5 22 22 classroom 0.4 23 23 classroom 0 . 5 24 24 classroom 0. 5 25 library 0. 6 26 main office 0 . 3 27 health room 0. 3 28 kitchen 0. 3 29 cafeteria < . 3 30 gymnasium 0 .4 31 gymnasium 0. 5 32 custodial office 0. 3 33 faculty lounge 0 . 5 Radon Survey Phillip Smith page 2 PHILLIP SMITH ELEMENTARY SCHOOL South Windsor, Connecticut LOCATION OF RADON SAMPLES December 29, 1989 i 1 HIV j0 BOILER • i'•T �q cAFE7fR1A 5 •$ L�' is 61MAJA5IUM Tzb% 1 I b y 3 ' T_ j L 6 zL � sy KEY: ADM, administrative offices FAC faculty room N B,G boy.gsupplies lavoratory suppl S iee s H nurse .1 ru•triinl G Z O 44 CODFISH LANE W WESTON, CONNECTICUT 06883 R A D O N S U R V E Y BROOKS Q 203-226-6970 V1 CT WATS 1-800-843-1631 TIMOTHY EDWARDS MIDDLE SCHOOL South Windsor, Connecticut RADON-IN-AIR Tested: 12129189 - 112190 SAMPLE ROOM NUMBER ROOM USE PCi1L 1 2 classroom 0. 6 2 4 classroom 0 . 3 3 6 classroom 0 . 4 4 8 classroom 0 . 5 5 Art-1 classroom 0. 4 6 Art-2 classroom 0 . 3 7 Home-1 classroom 0 . 3 8 Home-2 classroom 0. 5 9 10 classroom 0 . 7 10 wood shop 0. 3 11 metal shop < . 3 13 gymnasium 0.4 15 girl ' s locker room < . 3 16 boy' s locker room < . 3 17 100 offices 0 . 5 18 102 classroom 0 .4 19 104 classroom 0 .4 20 106 classroom 0 . 5 HYGIENE & SAFETY SERVICES SAMPLE ROOM NUMBER ROOM USE PCi1L 21 108 classroom 0 .4 22 assoc. principals 0 . 6 23 main office 0 . 4 24 supply room 0 . 5 25 principal 0 . 5 26 health room 0 . 5 27 134 suspension room < . 3 28 faculty lounge < . 3 29 kitchen < . 3 30 cafeteria < . 3 31 cafeteria < . 3 Radon Survey Timothy Edwards page 2 TIMOTHY EDWARDS MIDDLE SCHOOL South Windsor, Connecticut _ LOCATION OF RADON SAMPLES December 29, 1989 r SM Sw E • • Sid sw G b S • u Sw SW4 UPPER • • 'S f ��, LEVEL 1 u•aArty Sw . �•sw E .0"T VAOt0 { s ;O STALE WEII&A • (,yMNASlUM •� G � 5 16 MAIN ENTRY << •�' µ LEVEL 07 -, F r Sw SM � TSIP 1 Wut0. • LOWER •10I LEVEL j I � I KEY: ADF administrative offices •,) E,M women.men lavatory B,G boy,girl lavoratory GI,BL girl.boy locker room H nurse J custodial 5 supplies/storage M Z � ��!,� RADON SURVEY � 44 CODFISH LANE W WESTON, CONNECTICUT 06883 BROOKS Q 203-226-6970 WAPPING ANNEX LA CT WATS 1-800-843-1631 South Windsor, Connecticut RADON-IN-AIR Tested: 12129189 - 112190 SAMPLE ROOM NUMBER ROOM USE pCilL 1 1 classroom 0. 7 2 2 classroom 1 . 1 3 3 classroom 1 . 0 4 4 classroom 0 . 9 5 5 classroom 1 .0 6 6 classroom 0 . 5 7 7 classroom 0 . 7 8 8 classroom 0 . 7 9 9 classroom 0 . 8 10 10 classroom 0 . 7 11 11 classroom 1 . 0 12 12 offices 0 . 6 13 13 classroom 0 . 8 14 14 classroom 0 .8 15 15 classroom 0 . 5 16 16 classroom 0 .4 17 17 classroom 0 . 7 18 19 classroom 0 . 8 19 20 classroom 1 . 4 20 21 classroom 1 . 0 HYGIENE & SAFETY SERVICES SAMPLE ROOM NUMBER ROOM USE PCiA 21 24 classroom 1 . 5 22 music 0 . 5 23 weight room 0 . 5 24 kitchen 0 . 4 25 cafeteria 0 . 5 26 office 0 . 5 27 office 0 . 5 28 office 0. 7 29 office 0 . 6 Radon Survey Wapping page 2 WAPPING HIGH SCHOOL ANNEX South Windsor, Connecticut LOCATION OF RADON SAMPLES December 29, 1989 V flip sit f i4 fls �1 • ,� • 6 q • L �O e LR � B I:rtcgtw s J Ty J • / / � Music yj u UPPER �R s • • e LEVEL �' e • 3 •� i R p 6 s 1 BASEMENT ar KEY: B.G Doy.girl lavoratory L unisex lavoratory LR locker room s supplies J custodial P1 pipe tunnel N Z G Z O 44 CODFISH LANE IMM W WESTON, CONNECT/CUT 06883 R A D O N S U R V E Y BROOKS ¢ 203 22s-ss7o v1 CT WATS 1-800-843-1631 SOUTH WINDSOR HIGH SCHOOL South Windsor, Connecticut RADON-IN-AIR Tested: 12129189 - 112190 SAMPLE ROOM NUMBER ROOM USE pCiA 1 1 industrial arts 1 . 1 2 2 industrial arts 1 .0 3 3 industrial arts 1 . 2 4 4 industrial arts 1 .0 5 8 0 . 5 6 5 classroom 1 . 3 7 6 classroom 2 . 1 8 7 classroom 1 . 1 9 90(ABC) classroom 0 . 3 10 91 classroom 0 . 8 11 92 classroom 1 .4 12 93 classroom 2 .4 13 94 classroom 1 .0 14 95 classroom 1 . 5 15 96 classroom 1 . 9 16 97 classroom 2 . 0 17 98 classroom 1 . 7 18 99 classroom 1 . 5 19 B-5 storage 1 . 8 20 101 classroom 1 . 5 HYGIENE & SAFETY SERVICES SAMPLE ROOM NUMBER ROOM USE PCi1L 21 102 classroom 2 . 5 22 103 classroom 2 .8 23 104 classroom 2 . 0 24 faculty lounge 3 .2 25 book storage 1 . 1 26 career center 1 . 7 27 AV1 audio-visual 1 . 5 28 110 classroom 0.4 29 library 1 . 7 30 guidance offices 1 . 9 31 health room 1 . 7 32 custodial office 0.8 33 sports office 2 .8 34 cafeteria 0. 9 35 cafeteria 1 . 1 36 kitchen 1 .4 37 main office 2 . 2 38 main office 2 .'6 39 auditorium 0 . 8 40 auditorium 0.8 Radon Survey High School page 2 SAMPLE ROOM NUMBER ROOM USE PCVL 41 music 0 .6 42 music office/practice 0. 7 43 girl ' s locker room 0 .4 44 boy' s locker room 1 . 1 45 large gymnasium 1 . 4 46 large gymnasium 1 .4 47 small gymnasium 1 . 6 Radon Survey High School page 3 SOUTH WINDSOR HIGH SCHOOL South Windsor, Connecticut page 1 of 2 LOCATION OF RADON SAMPLES December 29, 1989 i 6yMbi C MvsIG o 7 � �•y; 6�13 a T A Au01To4wM GIF N I oil CAFETERIA I I •3� ally ELE,R r— • � _J s • 1 L1 • . 1 LIBRARY I PAL q1--� L& rc G f`• ; �I (a e KEY: ADM administrative offices FAL faculty room B,G boy,girl lavoratory N L,M women,men lavoratory S supplies J custodial BL,GL boy,girl locker rooms M1 mechanical .. +r r r. •�i t r,rr,r•r SOUTH WINDSOR HIGH SCHOOL South Windsor, Connecticut page 2 of 2 LOCATION OF RADON SAMPLES December 29, 1989 LOWER a LEVEL AC � e 11 UPPER LEVEL I 6 �" g M1 i l � T I s LOWER ' LEVEL r� N