HomeMy WebLinkAboutWell Correspondence 313 Troy Road Aquatek Labs
131 Bradley Road-Woodbridge, CT 06525
Water Analysis Report
WATER SOURCE: 313 TROY ROAD - SOUTH WINDSOR, CT
NO TREATMENT, TANK TAP
TO: SHAWS PUMP COMPANY DATE: 09/29/2008
20 LYONS STREET TEST# : A0929867
ELLINGTON, CT 06029
BACTERIOLOGICAL EXAMINATION
Total Coliforms Present Absent X
Fecal Coliforms Present Absent X
RESULT AL UNITS
PHYSICAL/CHEMICAL EXAMINATION
Turbidity 5 . 0 NTU
Color 15 -- -
Odor 2 - --
pH 10 . 0 - 6 . 4 ---
Calcium None mg/L
Magnesium None mg/L
Hardness 200 mg/L
Nitrate Nitrogen 10 . 0** mg/L
Nitrite Nitrogen 11. 00** mg/L
Sulfate 250 . 0 mg/L
Sodium 28 . 0 mg/L
Chloride 250 . 0 mg/L
Copper 1 . 30** mg/L
Iron 0 . 30 mg/L
Manganese 0 . 05 mg/L
CONCLUSIONS : Based on the above results, this water was safe
for drinking purposes at the time the sample was collected.
Sampled By: George Shaw under the direction of Aquatek Labs .
AL = Advisory Level = EPA Maximum Contaminant Level (MCL) or State
enforceable standard when value followed by ** .
N.D. = None Detected
* = exceeds AL, see attached sheet
✓ = below AL, see attached sheet
David M. Graham, Ph.D.
Laboratory Director
CT License #PH-0466