HomeMy WebLinkAboutSeptic Correspondence 00 Strong Road (6) J.R. RUSSO & ASSOCIATES Land Surveyors & Professional Engineers February 26, 2007 Robert Deptula Health Department Town of South Windsor 1540 Sullivan Avenue South Windsor, Connecticut 06074 Re: Application 07-11P, Rock E. Poulin 3-Lot Subdivision w/2 Interior Lots Strong Road Dear Mr. Deptula: Pursuant to your request, we have enclosed one(1) set of plans for your review of the above referenced application. The applicant hereby requests a letter of suitability from the Health Department indicating"on-site soils can support Code complying septic systems". Final approval of individual lot septic systems is not required at this time. Detailed septic design plans will be required prior to issuance of individual building permits. The following is a summary of the applicant's proposal: Rock E. Poulin proposes to subdivide a 12.9 acre parcel on the north side of Strong Road and west of West Road into 3 lots. Lots 1 &2 are proposed as interior lots in accordance with article 4.6 and thus contain at least twice the require lot area of the underlying zone(RR). Lots 1 &2 contain 6.0 acres and 2.0 acres respectively. These two lots will be serviced by individual private septic systems as shown conceptually on the enclosed plans (sheets 3 &4). Water services to these two lots will either be by individual private wells or MDC water service from Strong Road, depending on construction costs. The easterly end of the subject parcel (2.9 acres)will be conveyed to and combined with the easterly abutter in exchange for a 0.3 acre access strip to Strong Road. Lot 3 contains an existing house with private well and septic system and will retain enough land to meet the minimum lot area for the RR zone (0.9 acres). . lvin� Septic testing was conducted by you and Design Professionals, Inc. on 4/11/06. The observation data and test hole locations for lots 1 &2 are shown on sheets 3 &4 of the Page 1 of 2 1 Shoham Road • East Windsor, CT 06088 • TEL: (860) 623-0569 • FAX: (860) 623-2485 Re: Application 07-11P, Rock E. Poulin 3-Lot Subdivision w/2 Interior Lots Strong Road enclosed plan set. We were not provided with test data for the reserve area on Lot 3. If this information is available, please provide us with a copy to be incorporated into the plan set. Thank you for your assistance in this matter. If you have any questions,please contact our office at 623-0569. Dana Steele, P.E. J.R. Russo &Associates cc: Rock E. Poulin, applicant File#2006-041 J.R. RUSSO & ASSOCIATES L E 77 C R OF M%H S H��1�A° L 1 Shoham Road EAST WINDSOR, CONNECTICUT 06088 DATE JOB NQ, o Z (860) 623.0569 - —8- 'G7_0 FAX (860) 623.2485 ATTENTION Wk _ Ste, WE ARE SENDING YOU Ey Attached ❑ Under separate cover via the following items: ❑ Sho drawings El Prints Plans ❑ Samples El Specifications Copy of letter ❑ Change Order ❑ COPIES DATE NO. DESCRIPTION 2 2 74-v'7 /-Z '&t= I� �. THESE ARE TRANSMITTED as checked below: ❑ For approval ❑ Approved as submitted ❑ Resubmit copies for approval ❑ For your use ❑ Approved as noted ❑ Submit copies for distribution > ❑ As requested ❑1 Returned for corrections ❑ Return corrected prints ❑ ,.►y- �For review and comment i ��tt 1iY!'`t�_ 4. 44 ' ❑ FOR BIDS DUE ❑ PRINTS RETURNED AFTER LOAN TO US REMARKS COPY TO > A = Reorder From NEB$CUST&M-printing service 1-soo-an-6327 NEEtS,InC.Groton,MA01471 wx^+r.nebs. m el SIGNED: Ref.No:G 112,900035 J.R. RUSSO & ASSOCIATE_ S Land Surveyors & Professional Engineers February 26, 2007 Robert Deptula Health Department Town of South Windsor 1540 Sullivan Avenue South Windsor, Connecticut 06074 Re: Application 07-11P, Rock E. Poulin 3-Lot Subdivision w/2 Interior Lots Strong Road" 'Dear Mr. Deptula: Pursuant to your request, we have enclosed one (1) set of plans for your review of the above referenced application. The applicant hereby requests a letter of suitability from the Health Department indicating"on-site soils can support Code complying septic systems". Final approval of individual lot septic systems is not required at this time. Detailed septic design plans will be required prior to issuance of individual building permits. The following is a summary of the applicant's proposal: Rock E. Poulin proposes to subdivide a 12.9 acre parcel on the north side of Strong Road and west of West Road into 3 lots. Lots 1 &2 are proposed as interior lots in accordance with article 4.6 and thus contain at least twice the require lot area of the underlying zone(RR). Lots 1 &2 contain 6.0 acres and 2.0 acres respectively. These two lots will be serviced by individual private septic systems as shown conceptually on the enclosed plans (sheets 3 &4). Water services to these two lots will either be by individual private wells or MDC water service from Strong Road, depending on construction costs. The easterly end of the subject parcel (2.9 acres) will be conveyed to and combined with the easterly abutter in exchange for a 0.3 acre access strip to Strong Road. Lot 3 contains an existing house with private well and septic system and will retain enough land to meet the minimum lot area for the RR zone(0.9 acres). Septic testing was conducted by you and Design Professionals, Inc. on 4/11/06. The observation data and test hole locations for lots 1 &2 are shown on sheets 3 &4 of the Page 1 of 2 1 Shoham Road • East Windsor, CT 06088 • TEL: (860) 623-0569 • FAX: (860) 623-2485 Re: Application 07-11P,Rock E. Poulin 3-Lot Subdivision w/2 Interior Lots Strong Road enclosed plan set. We were not provided with test data for the reserve area on Lot 3. If this information is available, please provide us with a copy to be incorporated into the plan set. Thank you for your assistance in this matter. If you have any questions,please contact our office at 623-0569. SiacereLy Dana Steele, P.E. J.R. Russo &Associates cc: " ap applicant File#2006-041 Page 2 of 2