Loading...
HomeMy WebLinkAboutSeptic New 188 Smith Street can rzt tit On* indnn� Department of Pollution Control SOUTH WINDSOR, CONNECTICUT DRAIN LAYER'S PERMIT Application for Permit to Install or Repair Individual Sewage Disposal System Fee Paid $........... By Owxer...ts...Bu lalixg..Dep! . e....�9/11/74........................... Permit No. — ........,........,... ....................7...... 27, ......... Date 1 b October, 1974 Pursuant to written application, permission is hereby granted to the Licensed Drain Layer named herein for repair ......... or construction .X.., of an individual sewage disposal system concerning which the following information is submitted: 1. Owner of Property Behdax.„k.Olga„Mask-V—--M s............... Address of Owner ... .88......qm tk.,Stteet................... 2. Location of Property ....game ........................................... ........................................................... ................................................................... Lot No. .............................. 3. Type of Structure ..............Dwelling....................................................................................... (Dwelling, Commercial Building, Store, etc. 4. Number of Families or Persons to Occupy Premises .........Dxe....(.1. „.famlp,.„ 5. Number of Bedrooms ..Three ) ................. 6. Average Daily Flow ................................................... Manufacturer and 7. Liquid Capacity of Septic Tank . ..1000.... allons Material of Septic Tank .....Mot.des -- Concrete ....................................................... 8. Soil Conditions: Type of Soil .............................................................: ....................................................................................... (Sand, Gravel, Clay, etc.) Maximumground water table .....................................................................................:.......................................................................................: 9. If not served by public water supply: Distance from Owner's well ...Seve4ty..-fiv„e (75) feet From adjacent wells ......................................................... 10. Distance to nearest water course, drainage ditch, storm drain or embankment ............................................................:.......................... 1. Percolation Tests: Time for 1" drop in soil test ......Tkree (3) taixutee Classificationof soil .................................................................................................................................................................................................... 12. Minimum square feet of effective seepage area.required 12 ...eq... t....Irer be rest a total st 5.7 q 13. Leaching System: Number of trenches ..FQux':....(Y)................. Length ....152...f..t......................... Width ........ 3e.0...ft................ Total .....5........s..q....ft.,........... Other .............................................................................:........................................................................................... 14. Plot Plan Attached. ....... es.............................................. 15. Layout Approved. ............Yes ................................................. 16. This permit expires .........'..6....December.t....197 ............................................ Signature ..... .. .. ......... ward Martin (Licensed Drain Layer)W9-2d624$ Installation Completed, Inspected and Approved in accordance with State Public Health Code and Local Ordinances At-A51,5,,,9n...17 October 4 ByMelvin Edwards Jr. Pollution Problem abated Date ................................:...................................: Inspector U5 L .._------ 38 �o 4-0 4;1. M S -7 S 175.00' G tf 2.50 AC. t N/F N/F t WALTER a ANNA EUGENIA _WASYLENKO FRENCH �- O OD ti t` cD to VAGK -r�APcr4 Src-rioN -- 2`X 501 4 Lr:Atrlt�¢ T¢C-nicFJ 30 -8" 23' 2e 5CPTrc -rAnfk - MtAt 6 7' 57' 26 /O 00 4%Al G4P�GiTY 6(' M/N t HVH l Er9Ctf lwli ?(LE,vCN SEcTiGa' 5V Af?,4 Tt CA)— 1$ ' 0 eo4�NgNp C O fYHyy���i.� Q���V�4i fi 1L C6tiS7�✓c,Tt oAJ F,,. ,�'F�tis, 200' rj0` MCTNapS F'`mere1 fts 7-6 5T4TC TC+HSN M1liiht+yl 105 0 3 .001. S 5'rown q,�a s 7� No.5032 $ poi NO SURE tl**��+`� �� '2 , REED SM��H SEPTIC 5Y5rC-M L,4Yda-r MAP FOR - I HEREBY CERTIFY THIS MAP TO B Q H�A N 8j 0 LG A M A KSYM I U K BE SUBSTANTIALLY CORRECT AND IN ACCORDANCE WITH CLASS A-?i CODE OF CONN. TECHNICAL COUNCIL' INC. SMITH STREET SOUTH WINDSOR SCALE: I = 100' AUGUST 1974 WILLIAM J. . CARRINGTON , L.S. PERCOLATION REPORT r This is to certify that a Percolation Test was conducted on vcT�sr Z , 19`7¢, on the land of h AAN c G 4 M 9 k SYM i u K the location of which is indicated on the map` entitled: �o n_ 8 o N oA,y Qt-csrA /yA, sYrr r IJK�, SM Tt-1 -�T_ ICECT� J4✓TH W+a/taSU/� � ��/D01 ry✓G /97¢ Gt1c.u�� J l.la�'.O,,.dl;T�cl � L.S „� s The Test indicated the following soil characteristics: Aj o LaA�J Fa�,�e oN a2 AMMCAr grGLY' (3E,dG--ATN IvfF cjPjZ#VN0 supfj)cF� AM yECrETATidfs -r'RYIt *OAJO IN / 0L,--? _EN7i,e� OEPT�I �3lo�fJ caNSosTF<� of ,4 F,NE - /ZF-O .14N99 W17i+ !Ud S7auF5 dl2 CGBBcES, and said Test,gave the following indications: / 0 -'0OV,ulr CcM Pf- rr SA -rU 4 A Ti o hJ at TA T l o c.G 5T 2u AJ O. 63 PE2 NOv 2 AJ 0,93 Pc� �►,,r�yrE tit/14 IC-4 OeFSVL'rS I 3 M,MUrSf PLC/L rAJZCJl MaVEMATIONS /C}T L E-4 s r 375 5<K c--rl dE 1.E.4cN iq/6r i42EA FOP- A THtLC-G �S> hSEOltoo NUVS� <02 LASS wrm A 7/•(vd 5 4 17 Cl 0 0 6) 6AtL 0.tl C O NCKC r� 5C—f'T�G TANK , Please note that the recommendations are based upon limited investigations and, as such, are to be considered minimum values. Therefore, definite consideration should be given to the construction of a septic system in excess of the above minimum size and capacity. Signed '?r''Es., vo �900 175.00' �� ' 0 2.50 AC. t N/F N/F WALTER a EUGENIA -A N N A WASYLEN KO FRENCH _ O ti ,7D co 0 4 1� yo Y 8 2 3' 28' 67 57, 51, 26' A,40! r-13 N t°W*, i 200' of `1L a; No. 5032 I05o_3 M S IUD o00 flU 8-00' PE"ILG' TEST SITE SMS,'L N MAP FOR I HEREBY -CERTIFY THIS MAP TO BOHQAN a OLGA MAKSYMIUK BE SUBSTANTIALLY CORRECT AND IN ACCORDANCE WITH CLASS Q-L SMITH STREET SOUTH WINDSOR CODE OF CONN. TECHNICAL COUNCIL'-INC. SCALE: I" = 100' AUGUST. 1974 WILLIAM J. CARRINGTON ; L.S.