Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Septic New 250 Scott Drive
TOWN OF SOUTH WI N DSOR BUILDING DEPARTMENT South Windsor, Connecticut Application for Permit to Install or Repair Individual Sewage Disposal System Application No. 0 at TO THE BUILDING DEPARTMENT: Date P e 19� 7 A permit is requested for repair or construction of an individual sewage disposal system concerning which the following information is s mi ed ep% n Sc Iocurka 250 Scott Drive 1. Owner of Property Address of Owner 2. Location of Proper t l R 0- M 6 E S'��-s) 250 %a-TT AlJ* Lot. No. �g 3. Type of Structure a)WCL)- I PJ (Dwelling,Commercial—BuildingNo. of Bedrooms,Store,etc. 4. Number of Families or Persons to Occupy Premises_ 5. Plumbing Fixtures: Water Closets _ Urinals Lavatories_ Bathtubs.�—_ Showers_ Kitchen Sinks Laundry Tubs Garbage Grinder Other 6. Liquid Capacity of Septic Tank ZO 5� Material of Septic Tank 7. Soil Conditions: Type of Soil_W E,o?_Maximum ground water table (Sand,Gravel,Clay,etc.) 8. If not served by public water supply: Distance from Owner's well from adjacent wells 9. Distance to nearest water course, drainage ditch, storm drain or embankment 10. Percolation Tests: Time for 1" drop in soil test 7 Classification of soil 11. Minimum square feet of effective seepage area required--'If d 12. Leaching System: Number of trenches Length cQ 0 © Width �`3 Total Other Signature (Licensed Install (Sketch showing all minimum distances and other details re below) All -2 Permit Issued 19 By Installation Completed, Inspected and Approved 19 BY L '4 /ti, 14 -70 1 a I �( • Q all dw C1. I .. y ,i far _. _ ^ ', � d ,Q f nV� I + S Co !o s � r LOT #162, "BIRCk ItILL ESTATES, SECTION #7 TOWN OF SOUTH WINDSOR, CONNECTICUT SCALES 1 "= 40' L.S . #4395 �(,+0 Rockville, Conn. �►w� C-Q✓w or �� own of Oo* Department of Pollution Control SOUTH WINDSOR, CONNECTICUT DRAIN LAYER'S PERMIT Application for Permit to Install or Repair Individual Sewage Disposal System Fee Paid .............1Q.f..QQ By Q!, Pk ,.u..tn. . Permit t No .` .......... ........................................................................... .; ..................................................... ............................................ rDate 6::. Jlxro, .... .................................................. Pursuant to written application, permission is hereby granted to the Licensed Drain Layer named herein for repair N:4�.. or construction of an individual sewage disposal system concerning which the following information is submitted: 1. Owner of Property ....................... -0 ...............69 Address of Owner t T) 2. Location of Property .......................................................................................................................................................................... Lot No. ..........L62.1.......... 3. Type of Structure ............... ........... .............................. (Dwelling, Commercial Building, Store, etc.) 4. Number of Families or Persons to Occupy Premises ..........Pn� (1) 11 5. Number of Bedrooms �Imar (4) .... ................................................................................................... 6. Average Daily Flow ................................................... Manufacturer and 7. Liquid Capacity of Septic Tanki...,250 gall=6.................................................... Material of Septic Tank c on c rc,, 0 8. Soil Conditions: Type of Soil ........... !Jardpacked sand .............................I.................... ...............I..................I...................................................................................................................................................................... (Sand, Gravel, Clay, etc.) Maximum ground water table 9. If not served by public water supply: Distance from Owner's well ........................................ Fromadjacent wells ........................................................................................... 10. Distance to nearest water course, drainage ditch, storm drain or embankment ....................................................................................... 11. Percolation Tests: Time for I" drop in soil test . ........... ......................... Classification of soil .................................................. 12. Minimum square feet of effective seepage area required .................... ................ ......................... 13. Leaching System: Number of trenches ...........J�...V? ............. " " .................... . Lengthth ..........1.6 .....n....'(............. Width ....... . ......Total ?., f" 00 (0, + I � ......... 0ther ........... ......................... ................................................................................................................................................... 14. Plot Plan Attached. ......Y 15. Layout Approved. ............ ...................................................... 16. This permit expires ................................................... Signature ................................ ... . ....... .. ........................... (Licensed Drain I:ay6i) .......... Installation Completed, Inspected and Approved in accordance with State Public Health Code and Local Ordinances ............................................................................................................................. 19.................. By .............................................................................................................................. Pollution Problem abated Date ............................. .. ..........I......................... Jr, .............................................................................................................................................. Inspector N S3 "I S4 1 � I ' o C'9SfHENT 7 401 I I I ZI I 4i i � 3 7- 112 53 NOTES: Scale = 40, in 1" approx. SOUTH WINDSOR POLLUTION CONTROL S T #1 #2 LOCATION 250 Scott Drive (Lot 162) A 27.0 53.0 775 OWNER B ---- ---- 76.0 C 45.0 51.0 ---- TYPE OF WORK Septic Re air DATE 06-1 -72 PERMIT 72- 1 PIPE 4" O.B. INSTALLER Skipper W9-20 4 7 INSPECTOR ME DRAWN BY ME