HomeMy WebLinkAboutSeptic New 74 Saginaw Street 6r / ° _
FEE
TO THE BUILDING DEPARTMENT I Application No. �
TOWN OF SOUTH WINDSOR Date 6 " 's1/1 Z-
I hereby apply for permit to build a sewage disposal system for a
esidence , boarding house , hotel, etc.)
Owned by . «Fa s /;.e of tZ �
, T
And located at
To be built by of o26- 9 Z,¢ Ra,,
in accordance with detailed information stated below.
Signed
(Applicant)
. . . . . . . . . . . . . . .
GENERAL INFORMATION
1 . Estimated population of premises (present) 3 (future)
2. Description of premises (including number of bedrooms), cd &" s
No. Fixtures
(Above basement): Water Closets o2 Urinals Lavatories
Bath tubs j Showers / Kitchen Sinks / Laundry Tubs
Garbage Grinder List basement fixturesx�,, -s k,A���
3. Water Supply yvP-L L Kind of Well 0 ]azx-,z 4-
(Public, well , spring, cistern)
Location of well and underground water piping c3c;7' e:v
Method of obtaining or storing supply
(pumps , tank,, etc.)
4. Character of soil at proposed location of leaching system, including depths of
various strata 4 A v,,-
(sand, loam, clay, hardpan, rock, etc. --Use test pits.)
5. Elevation of highest ground water ,/o
(with reference to both present & future grade)
Description of proposed system (Furnish drawings of same , with plot plan showing
system including location, size , grade and material of house sewer and locations
of ground or surface water drains , wells and bodies of surface water.)
Septic Tank
Dimensions Capacity below flow line Z
Inlet and outlet arrangements
Facilities for cleaning C - Distance from dwellings on same
property on adjoining property
Automatic Dosing Apparatus , if any (describe)
Soil Absorption System
If cesspools , No. diameter ft.; depth below inlet ft.
If tile field or leaching trenches , total length is l7` " ft.
Width of trenches-AZ/ ft. , depth of broken stone or screened gravel ft.
Stone or gravel will be covered by.. Distance between
(tar paper, salt hay)
trenches ft. Distance from water supply on same property
on adjoining property
Secondary Treatment, if other than soil absorption.
Describe in detail and locate on map
System was designed by
-2f
Above information furnished by
No discharge of sewage or sewage effluent into any watercourse should be permitted
without approval of the State Department of Health and State Water Commission.
■ -ten✓ -.. ;- _. :z..
. ��•` `.
'N1�4J �QN0��21Y�I
Nil OS MO,Lut +I 6% Ott
ZWOT/� 101 • uT MOS
IE6Z 'oN ��, ��aix4� dT,'[tR�3utt3RQp� ti�� d�tt
ILt1mloa uo tosa x xlnos s 3 � �xaa dga,�aq I
TTCSI W 1
'�,l n•LL f2TO�.{[.1L1U �.t�1�{i��J•.:.•"t•i
�z
F
Gp. .
0 0 *;i I .
O
g
-1 53
o
i
a SiSl1
a c
p ^�
lr3` Ui4 iU'Yr T c 5W ^'_1 1. 'CTA.�,, t L't.iT T�i ?.TO.
I°0'i itT `'rL' og()-c Or TICS C T 0E
G?"f44edkxz