HomeMy WebLinkAboutSeptic Repair 446 Niederwerfer Road FORM#2 State of Connecticut Department of Public Health APPLICATION NU.
INVESTIGATION FOR SEWAGE DISPOSAL SYSTEM
Owner Location J(Yl N f 6OkU�w mac✓
PERCOLATION TESTS:(Record all Tests) SOIL MOISTURE:
(Date) (high,med.,low,etc.)
Vtac/h-f- flrC f0
TEST READINGS
. .HOLE HOLE - HOLE HOLE -
une ea g Reading Time Reading Time Reading
-7//
Y
TABULATION OF TEST RESULTS
Hole Location Depth Presoak Time Percolation Rate
Lft-,CK
OBSERVATION PITS:(Record all pits) Groundwater Table
(Date) (Near max.,Belo►max:,etc.)..
SOIL DESCRIPTIONS
PIT PIT . PIT PIT
77
TABULATION OF TEST RESULTS
Pit Location Depth Ledge Ground Water Mottling
1/1/00
49
FORM#2 Con'd State of Connecticut Department.of Public Health Investigation for Sewage Disposal System
r
to
2 6v
LOCATION DRAWING
SPECIAL CONDITIONS CONCLUSIONS
System design larger than 2,000 g p.d Suitable for sewage disposal
Water supply watershed
Possible seasonal high groundwater Unsuitable.for sewage
Watercourse,marsh or pond g °
Possible seasonal flooding _` — Additional investigation required
Limited suitable area
Excessive Slope(over 25%) 104 Retest during wet season
Marginal soil(30-60mins/inch)
Shallow ledge_(less than 5 fl.) / Monitor groundwater duu wet season
Underlying tight soil(less than 4 ft.)
Other Engineer's plan required -
DESIGN RECOMMENDATIONS
Y 13dk S' 1� !�! Cal, hie- wo-1 yer(
Investigated by Title
Confirmed/witnessed by Title
Comments:
1/l/00
IX-►
Itch
Two 102'by 12"by 34"Infiltrator trenches with 3.7 ef&466 sq'per linear foot
Required sq'for three bedroom home with perc.rate of 30 mutes per inch is 750 sq'
-MLSS=PF(2.0)*FF(1.5)*B F{56xslope is 29/o)=.6r"ii nimum system spread
Restrictive layer 24" Bottom of leaching trenches to �=dyer than 0.5'into existing grade
' TP 2 O perc.test TP 1
t$ A to Perc test pit 1035'
B to Perc test pit 82.25'
OV
O y
O
15'
�rn
B a
UtsE �
BM ele.4.i3'(concrete stair landing fiom beck) (y,
Sewer drain from house flow line ele.4.71'
invert inlet 5.03' ��
invert outlet 5.28' 50
perc test grade elevation 5.6'
TP 1 elevation 5.25'at grade
TP 2 elevation 6.0'at grade
top of infiltrators 4.75' .
bottom oftrench 5.75'
i
i
Concrete Products of Connecticut, Inc
PO Bog 190
N. Windham,CT 06256
(860) 423-4144
Date:June 12,2007
To whom it may concern:
This letter is to certify that Concrete Products of CT,Inc.performed a water pressure test
on the 1000 gallon Pump Chamber tank that was delivered to 446 Meiderweifer Road S.
Windsor,CT. This test was m accordance to the CT health code adopting the ASTM C-
1227, section 9.2.2. The liquid level in the tank that was filled with water for more than
24 hours,was measured and monitored for 1 hour.There was no change observed.
g contractor:
e fer Warn
oncrete Pr s of CT.,Inc
TOWN OF SOUTH WINDSOR
HEALTH DEPARTMENT
Application for permit to install a new/repair subsurface sewage disposal system. To the Health Department,
Town of South Windsor.
Fee Paid *tQ.v, C4&P- Date &Ak( Permit Number 2001 006 y(f
As a subsurface sewage disposal system installer licensed in the State of Connecticut, I
BVI NJ 5'I PULE OP77 F=ol2P6T LkVJV L SW-ta-��%, e M-%97 52-7 A
Name, Address, Telephone Number, License Number
hereby apply for a permit to construct/repair a subsurface sewage disposal system located at
and owned by "robA c3MW169
Street, ' `A�.dddress, Lot Number Name
Address
Information to be supplied by Applicar t:
Type of dwelling W-�SIpEA411 6I GI- ft If non-residential, estimated daily flow
Residential,commercial,Etc.
Number of bedrooms 3 Size of lot
Number of fixtures above basement _eJE_VEJ1t
Tubs,Sinks,Toilets,Etc.
Number of fixtures in basement, if any mama-( �ow� :2_ED Mo Ps�g�p
Pumped or gravity flow,
Type of water supply If private, type of well
Public-Private
Information to be supplied by Health Department:
Soil type at various levels
Percolation rate '30 r-A►" /rnrGtr+ . Square feet of effective leaching area required '750 nat gR
Size of septic tank 1000 Type of system I 0 LTRPaof!- `Metl tiES
Trenches,Drywel Is,Etc.
Number of dry wells, trenches, etc..a)i, Ina" IOrG. Distance between individual leaching
units. Distance from well on same property 751- on adjoining property
Curtain drain required 1442
Yes,No
Height of system above ground water t�3 maximum ground water
ledge '14 A, , impervious soil layer NSA
If automatic closing is required,description
A PLOT PLAN INDICATING LOCATION OF PROPOSED STRUCTURE, WATER SUPPLY, SEPTIC SYSTEM, EM-
BANKMENTS, WATERCOURSES, PROPERTY LINES AND ALSO INDICATING EXISTING AND PROPOSED
FINISHED GRADES MUST BE SUBMITTED BEFORE THIS PERMIT CAN BE ISSUED.
THIS PERMIT IS NOT TRANSFERRABLE FROM PERSON TO PERSON OR FROM PLACE TO PLACE.
NO PART OF THE SYSTEM SHALL BE BACKFILLED UNTIL IT HAS BEEN INSPECTED AND APPROVED BY THE
SANITARIAN.
SPECIFICATION AND REQUIREMENTS AS STATED IN THIS PERMIT MUST BE MET AND ANY CHANGES MUST
BE APPROVED BY THE TOWN SANITARIAN BEFORE FINAL APPROVAL WILL BE GIVEN.
THIS PERMIT SHALL NOT BE CONSTRUED AS PERMISSION TO CREATE A NUISANCE CONDITION NOR IS
THIS SYSTEM GUARANTEED T E HEALTH DEPARTMENT.
Permit Received by Date �`� 00107
S at re ppli &licen76
se Number
For Office Use Only
Permit issued by Date
System installed by
Final Inspection Approval Date
o
/^C.\Stet)u1e Inc.
General Contracting
Site Development
Construction Management
Septic Installation and Repair
Brian Stepule President ofc.860-633-7096
327 Forest Lane,Glastonbury,CT 06033 E-mail stepbuild@cox.net
newhomelic#1845 septicinstallerlic#0005971 homeimplic#548350
To: Tom Grenier 446Niederwerfer Rd., So. Windsor 256-7954, 648-9079
Soil tests done with Bob Deptula, 644-2511 ex. 248, in March 2007 show no
ledge, and mottling at 24", and perc. test rate of 30 minutes per inch. For a three bed-
room house at this rate 750 sq. 'of leaching is required. MLSS = 168'=FF 1.5 x PF 2.9
x BF 56 (slope 2%) because of reverse grade, we will need to raise the sewer pipe
through the side wall of the foundation to facilitate proper pitch and connect to the new
1000 gallon concrete tank. Then we will replace the existing downstairs toilet with an
injector tank/toilet of which will also handle the sink drain. Plumb the new fixtures up
and over into the new sewer line, (this drain will be visible up the bathroom wall and
across the unfinished ceiling.). The leaching field requirements are strip topsoil, fill
with select septic fill, lay two 102'rows of 48" by 34" by 12" standard infiltrators with
1 1/4" washed septic stone placed on top covered with 48" filter fabric to complete the
field. Bottom of trenches no deeper than .5' into existing grade. Redistribute topsoil re-
claimed during the stripping process. Bob rescinded the need for an engineer if a suit-
able design can be submitted by a licensed installer.
Thank you,
Brian Stepule
n9 ,•tom
Two 102'by 12"by 34"Infiltrator trenches with 3.7 effective sq'per linear foot
Required sq'for three bedroom home with perc.rate of 30, Minutes per inch is 750 sq'
MLSS=PF(2.0)*FF(1.5)*HF(56xslope is 29/e) , , mmimum system spread
Restrictive layer M' Bottom of leaching trenches to =deeper than ON into existing grade
' TP 2 O perc.test TP 1 '
A to Perc test pit 103.5'
B to Perc test pit 82.25'
O'
O
15' B
A B
BM ele.4.13'(concrete stair landing from deck)
Sewer drain from house flow line ele.4.71'
invert inlet 5.03'
invert outlet 5.28'
perc test grade elevation 5.6'
TP 1 elevation 5.25'at grade
TP 2 elevation 6.0'at grade
top of infiltrators 4.75' .
bottom of trench 5.75'
;ih'
V� / J-
J, of� _ _� . _ ���i'�� ���`�,� � _- - -
- _ ��2) 1 � � ����_�'�-ate _ - _______. _ _ -
MOWN sf,t�
F Taizow aps-ou& Vzola-40t
1540 SULLIVAN AVENUE - SOUTH WINDSOR, CONN. 06074
soa•co AREA CODE 203/644-2511
November 14, 1991
To Whom It May Concern:
This letter is written at the request of Georgianne Killeen of 446 Niederwerfer
Road, South Windsor, Connecticut.
At the request of a licensed septic system installer, this Department met with
said installer on 1118191 at 446 Niederwerfer Road, South Windsor for the purpose
of observation pits and perco la t ion testing at the property. Also present was
the property owner, Georgianne Killeen, as well as Ralph C. Miller and Anthony
Damiano.
No system fa i lure (ie: surfacing on the ground) was observed at this time. The
inlet of the septic tank was exposed. The tank was approximately half full. It
was reported that the tank had been pumped on 1114191. It was also reported to
this Department that two septic tank cleaners had stated that when the tank was
pumped, effluent from the leaching trenches flowed back into the septic tank.
The installer exposed the distribution box which was not full at that time. Two
pipes exited the box.
The installer also exposed one area of leaching trench. The stone at the top of
this trench was darkened indicating usage at this elevation.
The subsoil at the distribution box and trench area was of poor quality.
This may or may not be representative of the soil in the entire leaching area.
An observation pit was dug to the rear of the property, approximately 120 feet
from the house. The soil in this pit appeared capable of accepting a septic
system.
When this system fails, additional observation pits and percolation testing will
be required before a repair can be initiated. An engineered design and/or an
elevated system may or may not be required depending on the results of the above
activities.
Very truly yours,
t
Robert DeprLf7a, RS
Environmental Health Officer
RD:jh