Loading...
HomeMy WebLinkAboutWell Correspondence 00 Mountainview Road S PUDELER ENGINEERING Civil Engineering • Land Surveying 201 West Road, South Windsor, CT 06074-1928 Phone: (860) 610-0001 Fax: (860) 282-7726 November 18, 1998 Mr . Robert Deptula Environmental Health Officer Town of South Windsor 1540 Sullivan Avenue South Windsor, CT 06074 Re: Lot 10 & 11 Mountain View Road Dear Mr . Deptula: We contacted the State Department of Public Health concerning the water supply for Mr . Cho's lot . They replied with the attached letter . The state notes that Hillsdale Distribution system is unable to provide "adequate" potable water for my client. Furthermore, the letter indicated that only lots within a 200 foot distance of a community system are mandated to connect. Hillsdale Road is 250 feet from lots 10 & 11 . Therefore, the lot is beyond the required distance and is exempt from being required to connect . No exemption is required. Sincerely, Kenneth J. Pudeler, P.E. , L. S . attachment: McClellan Letter dated 11/10/98 with enclosures cc : Mr . Cho with attachements C\Tn7D\L5\DSlPTCJI.A.LTR STATE OF CONNECTICUT DEPARTMENT OF PUBLIC HEALTH MSip t November 16, 1998 Mr. Kenneth J. Pudeler, P.E.,L.S. 201 West Road South Windsor, CT 06074-1928 Dear Mr. Pudeler: I am in receipt of your 11/3/98 letter regarding a building parcel on Mountain Road in South Windsor, CT. Your client's proposed building lots are within 200 feet of the distribution system of Hillsdale Water Co-op and could be made to connect to the public water system according to the CT Public Health Code, see enclosed. The system now serves 11 homes in the immediate area but has limited storage facilities and the well pump is experiencing a diminishing pump rate. As such, this department would not mandate your client to connect to the distribution system of Hillsdale as it is unable to provide an"adequate" supply of potable water to your client's lot. This office would need a letter from Hillsdale stating that they are not interested in serving anymore new customers. I have talked to George Donahue of 1118 Sullivan Avenue who is Hillsdale's primary contact with this department. He said he would send a letter to that effect. Should your client wish to proceed with this well permit exception process,the contact person in this office is Paula Pendleton. I have enclosed her business card and list of required information to qualify for an exception. Should you have further questions please contact this office. Sincerely, Clifford A. McClellan, Jr. Sanitary Engineer 3 Water Supplies Section cc: Paula Pendleton Enclosures Phone: 0pqq_ Z; Telephone D"evice3 for the Deaf (860) 509-7191 ■ 410 Capitol Avenue - MS # 51WAT P.O. Box 340308 Hartford, CT 06134 An Equal Opportunity Employer Department of Health Services S 19-13•B61m rate of from ten to fifty gallons per minute; and seventy-two hours for a well with a required withdrawal rate of more than fifty gallons per minute. Test pumping shall be continuous at a constant rate for the period required. In the case of a public well,drawdown shall have held essentially stable for the last twelve hours prior to the completion of the test.The well contractor or tester shall record the date of the yield test;the water level in the well shortly before the yield test begins; the length of the pumping period; the constant pumping rate; the water level in the well at reasonable intervals after pumping begins and within five minutes before the pumping ends;and the water level in the well at reasonable intervals thereafter for a sufficient time to allow recovery to the water Ievel prior to the yield test. He shall furnish a copy of such record to the owner. (c) The pump installer shall disinfect each new well system before use. Disinfection shall be accomplished by treating the water in the well,storage tank and connected piping with a chlorine solution of fifty milligrams per liter(parts per million)strength so as to obtain a residual of ten milligrams per liter(parts per million)of chlorine after three hours detention.The side walls and piping shall be rinsed with the chlorine solution.The chlorinated water shall not be removed from the water system until after a detention period of at least three hours. (Effective January 12, 1971) Sec. 19-13-B511. Testing (a) In the case of a nonpublic water supply well,the owner shall have the well sampled,after disinfection and all chlorine has been dissipated,for bac- teriological,physical and sanitary chemical examination.Approval of the local director of health of the results of such examination shall be obtained before the well water is used. (b) Public water supply wells shall be sampled by the state department of health or local director of health for bacteriological,physical and sanitary chemical examination. Approval of the commissioner of health shall be obtained before the well water is made available for use. (Effective January 12, 1971) Sec. 19-13-B51m. Well permits (a) Subject to subsections(b)and(e)below no water supply well permit shall be given until it has been demonstrated to the satisfaction of the direc- tor of health that public sewers are available or a subsurface sewage dis- posal system can be installed on the lot in compliance with Sections 19-13-13103a to 19-13-B104d, inclusive of the Regulations of Connecticut State Agencies. (b) No water supply well permit shall be given by the director of health: (1) To premises used for human occupancy when a community water sup- ply system having at least fifteen service connections or regularly serving at least twenty-five individuals is deemed available if the boundary of the parcel of property in which the premises is on or will be located on is within two hundred feet,measured along a street,alley or easement,of the approved water supply: or S 1913 H51m Department of Health Services r human (2) To non-residential premises,wheresu supply having at be used ;least fif- consumption, when a community water pp at least twenty-five individ- teen service connections or regularly serving dary of the parcel of property in which uals is deemed available if the boun the premises is on or will be located nt �s within prop ed water supply.ea- sured along a street, alley or easement, of the approvedant (c) The commissionJ of he above upCoen,or his or a finding that sucher exception an exception to subsectionro) adequacyand of the supply nor the service not adversely affect the ermined that: is unable to of the system or itremises (1) The community water system which serves the premises of water: or provide such premises with a pure and adequate supp y (2) If construction problems warrant such action. 2 (Effective February , ing machin Sec. 19-13 e operations -B62. Food corporation shall opeverage aate or ma stain within the state No person,firm o public use which, upon inser- any self-service vending machine-offered for p tion of a coin,coins ortoken k in btoilk or package other , Hance ut replenishing the denses unit evice food or beverages,either between each vending operation, except after compliance with the ow- ing requirements: dents offered for safe throu machines shall tired,processed and prepared in establishments which comply livable local, state and federal laws and regula- tions. All packaged N -`J, y••Lf ti �• r r � u t List of Required Information for a Well Exception Request Letter Format Request Exception to P.H.C. 19-13-B51m ,. 3+ ;y t� '�,•�. Give property ddress & phone number address, present homeowner's a g;,, •. particularly construction ,z Adequate justification for Exception, p ressure due problems, ledge, wetlands, long service lines, inadequate p .L; ;r .,.. .. } to elevation, etc. Map, scale 1"=100' or better, parcel boundary lines, footprint of house, location of pws, distance to parcel, lineal feet of main needed, length of location of sewer or septic system, �:�;,,� '•,'�1�'�,;;;;�' service line from main to house, location of proposed well. y l`'• e- w ��v ws is available (i.e. , not on a private road) . ,.,, Indicate if access top '� "•w`` ::` ,.;. le. Total cost estimate of pws- Total cost estimate of well service. �• :,,; Letter from pws if they deny service. F � �1 {