HomeMy WebLinkAboutSeptic Repair 74 Miller Road PERM SOUTH WINDSOR HEALTH DEPARTMENT APMCA=011 1.+10.
INPESTIGATI01T FOR SEWAGE DISPOSAL SYSTm
. Re�o�
Owz= 3�►Me a w� �Iit_�, LOCA=ON y v
PERCOLATION TESTS: (Record all testa) e-•q -g ff SOIL, MOISTURE:
Date ga, med., low etc.
TEST READINGS
HOLE #1 ROLE #2 FCLE #3 HOLE ,
Time Reading Time Reacting Time Reading Time Reading
3=" 3 yz.
3Ls 3
ys 9
TA3ULATIO74 OF Tn...'T RISL7-TS
Depth Presoak Minimum .Percolation slate
Hole Location, (Torches) Ers. } (Mina./Inch)
1 �C> f
2
3
QBSER7AT10N FIT^: (Record all pits) 8--q-38' Ground Water Table;
?ate ;Year mAx.I Be ow Amax.; --..-,.c
OTI DFSCR1?TT N"S -
PIT A PIT B P?T C I PIT D .
I8 t=3D`= weed - si My
TABULATION OF OBSERVATION Pi"'S
Ground Soil
Pit Locaticu Depth Ledge At Water At Mcrt,4n.- at
A
B
C
D
(Over)
�sn 1rQ 5 U U !H w t N U J U K 11 L A L TH -c- InvestilgaZzon_ror Sewage, Disposal.Syste
DEPARTMENT
SPECIAL CONDITIONS
System design larger than 2,000 g.p.d. Water supply watershed
ffigh ground water (less than 14 ft. ) Possible seasonal high
ground water
Watercourse, marsh or pond Possible seasonal flooding
Limited suitable area Slope over
Marginal soil (30 - 60 mins./inch) ledge (less thaa 7 ft.)
Uaderlying tight soil (less than 4 ft) Other
CONCLUSION
N�c Suitable for sewage disposal
yd sj Unsuitable for sewage disposal
♦Cs,} -,t Additional investigation required
V-"v`f FA Retest during Wet season
3idneer's plan required
DESIGN RECOMMMMATIONS
Investigated,by gau ��- Title Gwy . }�Qa O
Confirmed/Witnessed by Title
Comments:
3ench.mark location Elevation
N
Ste�s
3y�
ly'
3y ISM
NOTES SOUTH WINDSOR HEALTH DEPARTMENT
A D 40 LOCATION 7 Y M i l of r
OWNER Per
SIN- Vts^ir.u,cr �br wSrci'p TYPE OF WORK air
act �� far 3`+i.e pF-C j r,a_ DATE — - PERMIT PIPE
(u s ilMldA lKfJA4WCAf VHF-- � % ) INSTALLER W I C rK 1Cw i
INSPECTOR DRAWN BY
STATE OF CONNECTICUT
9 DEPARTMENT OF HEALTH SERVICES
ON-SITE: SEWAGE DISPOSAL SECTION
NOTICE OF EXCEPTION
An exception is hereby granted to the requirements of Technical Standard 11A of
Regulation 19-13-B103 of the Public Health Code of the State of Connecticut for
the e9LAC'e-m GNS�- of a subsurface sewage disposal system
on the PjFr22�T�no
in the Town of Connecticut. It has been found that
the well located at
unlikely to be polluted in such a manner as to cause a health hazard, provided:
Mar LEIS &4t! 66 s AZ
y
h
�Jlwpsole Zl_m tvv
Recorded at the Connecticut Department of Health Services, Hartford, CT.
Si, !98S
Date
Frank A. Schaub
On-site Sewage Disposal Section
Phone. 566-1251
150 Washington Street — Hartford, Connecticut 06106
An Equal Opportunity Employer
NORTH
F John S:.GI:VICK
100.0,
CP
NIP
NIP -
`^ -1 r John
Joseph "I. and Lynn r'�l
SEUVICK
VEDOVATO I 'S' 18l
\\ N N
60-11" /
i
59.5 S4
MILLER ROAD
PROPERTY
of
JAIdjES R. and JANET M. PERRY
•74 miller Road South Windsor., Conn.
Scale V = 50' July 29, 1976
I hereby certify
to the tECHANICS SAVINGS BANK that this survey was made on the Sro.
e sub—
on July 28, 1976 and that it and the 'pounds and measurements soo�ssion. areereon rthe sar'
stantially correct; that the oVM; theresaredno1nes of actual Zoning Regulations or Restrictive
the building is located as shovm;
re are no easements or encroachments affecting this
Covenants violated; and the
f property. �o�oONHecr�cG
Qv1cT I qS 6 a� t'J6 wc�
/��nl r�s5assoc's 0((G'e
Np� 6293
�° Ema
o- nuel W. Week Conn' Reg L.
�Fcist�` go
��o•MN Sf,`� ,
C r Tiov� 0
e P
U
1540 SULLIVAN AVENUE SOUTH WINDSOR. CONN. 06074
�lN�soe•ca AREA CODE 203/644-2511
January 26, 1989
Mr. Steven Heninger
AR Lombardi Associates, Inc.
25 Terrace Drive
Vernon, CT 06066
Dear Mr. Heninger,
The plan for the septic system repair for James Perry, 74
Miller Road, dated December 1988 is approved with the
following addition: To ensure that the effluent does not
"break out" the westerly side of the leaching trench, the
finished grade 100 must extend another ten feet to the west
of the trench.
Unless you or Mr. Perry choose to, it is not necessary to
re-draw the plan. I have conveyed this information to Mr.
Perry and he has agreed to inform his septic system
installer to contact this department to discuss this
requirement before installation begins.
Robert D tula, A.97.
Environmental Health Officer
Cc. Mr. James Perry
74 Miller Road
South Windsor, CT 06074
RD:ls
O "CONSULTING ENVIRONMENTAL ENGINEERS"
25 Terrace Drive
ASSOCIATES, I N Ci. Vernon, Connecticut 06M
Telephone(203)872-2703
A.Richard Lombardi,P.E.,President
James C.Sommers,L.S.,Vice President
December 16, 1988
Mr. Robert Deptula, R.S.
South Windsor Health Department
South Windsor Town Hall
1540 Sullivan Avenue
South Windsor, CT 06074
Re: Septic System Repair
Mr. James Perry
74 Miller Road
ARL Project No. 88-1766
Dear Bob,
We are forwarding plans on behalf of Mr. James Perry for review and
approval.
Upon detailed design, we are proposing 140 linear ft of trench,
that is, eight (8) linear feet less than what was shown on the preliminary
design. The distribution box is proposed with the high-level overflow
going towards the west trench to ensure that the trench closest towards
the embankment is not overloaded.
If you have any questions, please call.
Sincerely,
A.R. LOMBARDI ASSOCIATES INC.
Steven G. Heninger
SGH:led
cc: Mr. James Perry
Enclosures
WASTEWATER•WATER SUPPLY •HAZARDOUS WASTES • WATER RESOURCES• GEOHYDROLOGY
SITE PLANNING •DRAINAGE •ENVIRONMENTAL IMPACT ASSESSMENT•SURVEYING
�) RAISE
N
A1-G
S p 7i c 7 a Iv/<
; z
7) IVC/�
Ln
N I are K
VAp/A �0
unutw
I000GAL
2 5`/ZZ'-12
{ k ♦ PfR(,
a, }
,.r
a
it k F.I
s
t k,�
n
yy
J ,M1
t
ASSOCIATES
CONSULTING CIVIL AND SANITARY ENGINEERS ��� LAII -10
LAND SURVEYORS
VERNON
-CO14NECTICUT
COMM. NO: DATE: SCALM
�7� ���� � f�' r , BHT. NO:
.r OF ..»»�..
17,1