Loading...
HomeMy WebLinkAboutPermit to Discharge New 474 Main Street `OW N SZq C� O ' O C 1 y � w` 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CT 06074 ox CO TELEPHONE (860) 644-2511 PERMIT TO DISCHARGE Approval is hereby given to 474 Main Street,in accordance with the Public Health Code, Section 19-13-B103e(h)to discharge to a subsurface sewage disposal system located at 474 Main Street,in the town of South Windsor,CT,that will receive treated domestic sewage from a: Four(5)Bedroom Residence Permitted Volume/Design Flow=750 Gallons per day *In order to provide a sufficient factor of safety,it is recommended that the average daily discharge not exceed 2/3 of the design flow or 300 gallons per day. Operation and Maintenance: The septic tank shall be inspected regularly and cleaned as needed but not less frequently than every five years. The septic tank has an effluent filter. Effluent filters require periodic cleaning.Failure to clean the filter could result in a backup of sewage into the building or effluent breakout. Special Requirements and Restrictions: 1.Use of a kitchen garbage disposal is not recommended. 2. Signs of malfunction or failure should be addressed. Exceptions: Exception to connect to central system granted on 12-3-09 Date of Final Inspection: December 15,2009 Inspected by: Robert De Vito,R.S.Environmental Health Officer Signature: Date: towN a��t 0 -0� slaa G � • u s 1540 SULLIVAN AVENUE•SOUTH WINDSOR,CT 06074.2786 AREA CODE 860/644,2511 FAX 860/644-3781 MATTHEW B.GALLIGAN Town Manager December 17, 2009 Mr. Greg Neary 474 Main Street South Windsor,CT 06074 Dear Mr. Neary: Pursuant to your request, this letter is written in regard to the various permits that have been taken out on your property. I have reviewed the information on file in the Building Department, Planning Department, and Health Department that pertain to your property. With regard to the Building Department, any construction done to the house and garage that we have been made aware of has had all necessary permits taken out. The Planning Department approved a Home Occupation Permit (Office Only) for the living space above the garage. Please note that Home Occupation Permits do not run with the land. Any future owner of 474 Main Street would need to acquire a new Home Occupation Permit from the Planning Department or the Planning & Zoning Commission should they want to utilize this living space for a home occupation. Planning & Zoning Commission approval would be required in order to use.the living space as an in-law or accessory apartment; this approval would also have to be sought by each additional owner of this property. As you may recall, there were outstanding Public Health Code issues as noted in the letter dated December 9, 2009. On December 15, 2009, you received a Permit to Discharge, which,reflects final approval from the Health Department confirming that all Public Health Code issues have been resolved. Should you have any further questions or concerns,please do not hesitate to contact my office. Very truly yours, C Matthew B. Galligan Town-Manager cc: Building Dept., Planning Dept. 'COW N Sf4 O ` Y G J m � 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CT 06074 sox'c° TELEPHONE (860) 644 2511 November 23, 2009 State of Ct Department of Public Health 410 Capitol Avenue, MS#51 SEW P.O. Box 340308 Hartford, CT 06134 ATTN: Sean Merrigan Re: Request to connect detached garage to central system owned by Rose Neary located at 474 Main Street, South Windsor, CT 06074 Dear Mr. Merrigan: The owner of the above referenced property has requested to convert the area above the detached garage into habitable space that will contain one bedroom. They would also like to request an exception to section 19-13-103d(d) and connect to the central subsurface sewage disposal system. The existing subsurface sewage disposal system is properly sized for a four(4)bedroom house and all the requirements of B 100a have been met for a two bedroom system. As you know a two bedroom system application was applied during the review because this is the minimum sized system allowed by the Technical Standards of the Public Health Code. There is room enough in the yard directly below the existing septic system for a six(6)bedroom septic system repair when the need arises. If you have any questions or would like to discuss this request further,please call me at 860-644-2511, extension 248. Sincerely,, Robert De Vito, R.S. Environmental Health Officer CC: Rose Neary, Homeowner Matthew Galligan, Town Manager Marcia Banach, Director of Planning Christopher Dougan, Building-Official ` TOWN OF SOUTH WINDSOh HEALTH DEPARTMENT Application fo ew ermit to install a epair subsurface sewage disposal system. To the Health Department, Town of So inds r. Fee Paid Date Permit Number As a s surface sewage disposal system installer licensed in the State of Connecticut, I Name, Address, Telephone Number, License Number her b ppl for a permit to construct/repair a subsurface sewage posal sys m located at T �(/^� Gj I and owned by Street, Address, Lot Number N me Address Information to be supplied by Applicant: / Type of dwelling t t If non-residential, estimated daily flow Residential,Commercial,Etc. Number of bedrooms Size of lot Number of fixtures above basement Tubs,Sinks,Toilets,Etc. Number of fixtures in basement, if any , Pumped or gravity flow, Type of water supply If private,type of well VublirivateInformation to be suppy Health Department: Soil type at various levels Percolation rate Square feet of effective leaching area required Size of septic tank Type of system Trenches,Drywells,Etc. Number of dry wells, trenches, etc. Distance between individual leaching units. Distance from well on same property on adjoining property Curtain drain required Yes,No Height of system above ground water maximum ground water , ledge . , impervious soil layer If automatic closing is required,description A PLOT PLAN INDICATING LOCATION OF PROPOSED STRUCTURE, WATER SUPPLY, SEPTIC SYSTEM, EM- BANKMENTS, WATERCOURSES, PROPERTY LINES AND ALSO INDICATING EXISTING AND PROPOSED FINISHED GRADES MUST BE SUBMITTED BEFORE THIS PERMIT CAN BE ISSUED. THIS PERMIT IS NOT TRANSFERRABLE FROM PERSON TO PERSON OR FROM PLACE TO PLACE. NO PART OF THE SYSTEM SHALL BE BACKFILLED UNTIL IT HAS BEEN INSPECTED AND APPROVED BY THE SANITARIAN. SPECIFICATION AND REQUIREMENTS AS STATED IN THIS PERMIT MUST BE MET AND ANY CHANGES MUST BE APPROVED BY THE TOWN SANITARIAN BEFORE FINAL APPROVAL WILL BE GIVEN. THIS PERMIT SHALL NOT BE CONSTRUED AS PERMISSION TO CREATE A NUISANCE CONDITION NOR IS THIS SYSTEM GUARANTEED BY THE HEALTH DEPARTMENT. Permit Received by I Date Signature of Applicant R License Number For Office Use Only Permit issued by ��T� i Date i System installed by Final Inspection Approval Date c/�/r► Y� ;OWU;1--S&nn ,N DSO /1#0�2_Jn��� HEALTH DEPARTMENT S Application for permit to install a new/repair subsurface sewage disposal system. To the Health Department, Town of South Windsor. Fee Paid Date �Jcc. O Permit Number As a subs rface sewage disposal system installer licensed in the State of Connecticut, I �uf"f-S r-0w-1— Rtmt�151a, Name, Address, Telephone Number, License Number hereby apply for a permit to construct/repair a subsurface sewage di posal system located at �(�Fy ma ,S4 and owned by Street, Address,,, /Lot Number Name Tr r� Address Information to be sup lied by Applicant: Type of dwelling sup lied If non-residential, estimated daily flow Residential,Commercial,Etc. Number of bedrooms Size of lot Number of fixtures above basement Tubs,Sinks,Toilets,Etc. Number of fixtures in basement, if any , Pumped or gravity flow, Type of water supply If private,type of well ublic rivate Information to be supplied by Health Department: Soil type at various levels Percolation rate Square feet of effective leaching area required Size of septic tank Type of system Trenches,Drywells,Etc. Number of dry wells, trenches, etc. Distance between individual leaching units. Distance from well on same property on adjoining property Curtain drain required Yes,No Height of system above ground water maximum ground water , ledge , impervious soil layer If automatic closing is required,description I A PLOT PLAN INDICATING LOCATION OF PROPOSED STRUCTURE, WATER SUPPLY, SEPTIC SYSTEM, EM- BANKMENTS, WATERCOURSES, PROPERTY LINES AND ALSO INDICATING EXISTING AND PROPOSED FINISHED GRADES MUST BE SUBMITTED BEFORE THIS PERMIT CAN BE ISSUED. THIS PERMIT IS NOT TRANSFERRABLE FROM PERSON TO PERSON OR FROM PLACE TO PLACE. NO PART OF THE SYSTEM SHALL BE BACKFILLED UNTIL IT HAS BEEN INSPECTED AND APPROVED BY THE SANITARIAN. SPECIFICATION AND REQUIREMENTS AS STATED IN THIS PERMIT MUST BE MET AND ANY CHANGES MUST BE APPROVED BY THE TOWN SANITARIAN BEFORE FINAL APPROVAL WILL BE GIVEN. THIS PERMIT SHALL NOT BE CONSTRUED AS PERMISSION TO CREATE A NUISANCE CONDITION NOR IS THIS SYSTEM GUARANTEED BY THE HEALTH DEPARTMENT. Permit Received by g�rj Date S' nature of Applicant&License Number For Office Use Only Q Permit issued by 9LDate System installed by Final Inspection Approval Date STATE OF CONNECTICUT DEPARTMENT OF PUBLIC HEALTH TaaNsr�iir NOTICE OF EXCEPTION An exception is hereby granted to the requirements of Section 19-13-B 103d(d) of the Connecticut Public Health Code for a CENTRAL SUBSURFACE SEWAGE DISPOSAL SYSTEM serving A HOUSE AND DETACHED 1-BEDROOM INLAW APARTMENT/GARAGE located at 474 MAIN STREET in the Town of SOUTH WINDSOR, CT. A central system has been found to be technically preferable for the following reasons: 1. THE CENTRAL SYSTEM SHALL PROVIDE FOR AN IMPROVED DISTRIBUTION AND TREATMENT OF SEWAGE EFFLUENT. 2. WASTEWATER THAT IS NOT"SEWAGE"AS DEFINED IN PHC SECTION 19-13-B 1 03b(a) SHALL NOT BE DISCHARGED TO THE SEWAGE DISPOSAL SYSTEM. 3. THE INSTALLATION SHALL BE INSPECTED BY THE LOCAL HEALTH DEPARTMENT, AND AN APPROVED AS-BUILT PLAN SHALL BE SUBMITTED PRIOR TO THE PERMIT TO DISCHARGE BEING ISSUED. Recorded at the Connecticut Department of Public Health, Hartford, Connecticut. • 3r i 2a(D DATE -L-2) Sean Merrig Sanitary Engi jerII Environmental Engineering Program Phone: (860) 509-7296 Fax: (860) 509-7295 Telephone Device for the Deaf (860) 509-7191 410 Capitol Avenue-MS#51SEW P.O. Box 340308 Hartford, CT 06134 Affirmative Action/An Equal Opportunity Employer �pWN Sf4 �s-ate ?d co r � � J y � w` 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CT 06074 r�OSOR-Co�� TELEPHONE (860) 644-2511 December 9, 2009 Rose Neary 474 Main Street South Windsor, CT 06074 Re: Notice of Exception to connect detached garage to central system located at 474 Main Street, South Windsor, CT 06074 Dear Ms. Neary: Enclosed you will find a copy of the Notice of Exception granted by the State of Connecticut, Department of Public Health, Subsurface Sewage Disposal Section. This document allows you to legally connect the detached one bedroom residence above the garage located at the same address to the existing central septic system that currently serves the home. The next step toward final approval from this office is to apply for a permit and have all subsequent work inspected by a representative from this office. When all the work is inspected and approved a Permit to Discharge will be issued which constitutes final approval. If you have any questions or would like to discuss this request further,please call me at 860-644-2511, extension 248. Sincer y, Robert De Vito, R.S. Environmental Health Officer CC: Rose Neary, Homeowner Matthew Galligan, Town Manager Marcia Banach, Director of Planning Christopher Dougan, Building Official Encl: 1 } A STATE OF CONNECTICUT DEPARTMENT OF PUBLIC HEALTH TR��IiT NOTICE OF EXCEPTION An exception is hereby granted to the requirements of Section 19-13-B 103d(d) of the Connecticut Public Health Code for a CENTRAL SUBSURFACE SEWAGE DISPOSAL SYSTEM serving A HOUSE AND DETACHED 1-BEDROOM INLAW APARTMENT/GARAGE located at 474 MAIN STREET in the Town of SOUTH WINDSOR, CT. A central system has been found to be technically preferable for the following reasons: 1. THE CENTRAL SYSTEM SHALL PROVIDE FOR AN IMPROVED DISTRIBUTION AND TREATMENT OF SEWAGE EFFLUENT. 2. WASTEWATER THAT IS NOT"SEWAGE"AS DEFINED IN PHC SECTION 19-13-B103b(a) SHALL NOT BE DISCHARGED TO THE SEWAGE DISPOSAL SYSTEM. 3. THE INSTALLATION SHALL BE INSPECTED BY THE LOCAL HEALTH DEPARTMENT, AND AN APPROVED AS-BUILT PLAN SHALL BE SUBMITTED PRIOR TO THE PERMIT TO DISCHARGE BEING ISSUED. Recorded at the Connecticut Department of Public Health, Hartford, Connecticut. DA E Sean Merrig Sanitary Engi jerII Environmental Engineering Program Phone: (860) 509-7296 Fax: (860) 509-7295 Telephone Device for the Deaf (860) 509-7191 410 Capitol Avenue-MS 9 51SEW P.O. Box 340308 Hartford, CT 06134 Affirmative Action/An Equal Opportunity Employer ' Page 1 of 2 Devito, Robert From: DeVito, Robert Sent: Tuesday, November 24, 2009 2:44 PM - To: Carson, Patrice; Dougan, Christopher Cc: Galligan, Matthew; Banach, Marcia; Lipe, Michele; 'Merrigan, Sean' Subject: RE: 474 Main Street Hi Everyone, For the sake of clarification and in response to the a-mails I would like to take a moment and explain that this building is served by a septic system and as such the building and its use may be governed by other regulations but most certainly it is governed by the Public Health Code. The interpretation of the space above the garage is just part of what the Public Health Code governs for this building and for simplicities sake I will confine my comments to this part of the code.This dept understands that there are several depts. that must review the space above the garage and all the depts. may not agree on what the use of the space is but they certainly should not be contradicting other depts. regulations. In essences one depts. interpretation does not trump another. This matter has been discussed with the State Health Dept Sub Surface Sewage Disposal Section and they have agreed with the results of the review of this dept.which are that the habitable space above the garage meets with the definition of a bedroom as outlined in the Technical Standards for Subsurface Sewage Disposal Systems located on page 13 and. Please feel free to discuss this matter with me at anytime. Bob From: Carson, Patrice Sent: Tuesday, November 24, 2009 12:03 PM To: Dougan, Christopher Cc: Galligan, Matthew; Banach, Marcia; Lipe, Michele; DeVito, Robert Subject: RE: 474 Main Street Hi Chris, Thanks for the heads up on 474 Main Street. You are correct that there are relevant issues for Planning and Zoning should the space be used for anything besides a Home Office, or if the property is sold, in which case the new owner would need to re-apply for permits. The Zoning file contains a copy of a November 19, 2009 letter to Mr. Greg Neary from Town Manager Matthew Galligan which clearly spells out the implications for the property with regard to Planning and Zoning. It also seems to address the issues of the Building Department and the Health Department, but I would defer to those departments authorities. Pbttr%ce L. Carsov,, Alal>, CZ,ET Zoning Enforcement Officer 1540 Sullivan Avenue South Windsor,CT 06074 patrice.carson@southwindsor.org 860.644.2511 x251 860.644.7280 fax From: Dougan, Christopher Sent: Monday, November 23, 2009 11:29 AM To: Carson, Patrice Cc: Galligan, Matthew; Banach, Marcia 12/4/2009 Page 2 of 2 Subject: 474 Main Street Patrice, I was cc'd a letter dated November 23, 2009, from South Windsor's Sanitarian to the State of CT Department of Health regarding Rose Neary's detached garage and her septic system at 474 Main Street. To avoid any confusion or misinterpretation,by the homeowner, the conversion of a space above a garage for sleeping purposes must be in compliance with the State Building Code, which will require a new building permit application. There may be relevant issues for Zoning, if the space is intended as an in-law or accessory apartment. As it presently stands the existing habitable space above the garage, is the home owner's office. This space(office), in its present configuration does not allow for a code compliant bedroom use. Christopher J. Dougan CHIEF BUILDING OFFICIAL TOWN OF SOUTH WINDSOR (860)6442511 EXT 232 CHRISTOPHER.DOUGANC&SOUTHWINDSOR.ORG 12/4/2009