Loading...
HomeMy WebLinkAboutWell New 220 Long Hill Road P WELL:COMPLETION REPORT STATE OF CONNECTICUT — fill in cPR-v REV.It_E2 DEPARTMENT OF CONSUMER PROTECTIONDo NOT WELL DRILLING BOARD STATE WELL NO.' 165 CAPITOL AVE. HARTFORD,CONNECTICUT 06106Y OTHER NO. r� NAME _ - [ADDRESS OWNER Ted Korzeip153 Northview Drive , SO. Windsor, CT,LOCATION 22® (No. & Street) (Town) (Lot Number) OF WELL -! bona Mill road _ South Windsor 5 L ESTABLISHMENT El FARM TEST WELL — PROPOSED DOMESTIC USE OF PUBLIC AIR WELL THER SUPPLY INDUSTRIAL CONDITIONING ((Specify) DRILLING EQUIPMENT D AIRM PERCUSSION PERCUSSION (Spec CABLE ify) ROTARY CASING LENGTH(feet) DIAMETER (inches) WEIGHT PER FOOT IV H WAS CASING GROUTED? DETAILS 86 1-7 � THREADED WELDED X1 YES �NO YES NO YIELD HOURS YIELD (G.P.M.) TAT BAILED ❑ PUMPED a> COMPRESSED AIR WATER MEASURE FROM LAND SURFACE—STATIC(Specify feet) DURING YIELD TEST(feet) Depth of Completed Well LEVEL 40 �300 in feet below Land surface: �� MAKE LENGTH OPEN TO AQUIFER (feet) SCREEN DETAILS SLOT SIZE DIAMETER(inches) IF GRAVEL Diameter of well including7��_R�Zk (inches) FROM(feet) TO(feet PACKED: grovel pack (inches): DEPTH FROM LAND SURFACE FORMATION DESCRIPTION Sketch exact location of well with distances, to at least FEET TO FEET two permanent landmarks. 0 80 sand, gravel, hardpan 80 300 granite .z_P_ l N j e :,Rifit Si d :f €t If yield was tested at different depths during drilling, list below FEET GALLONS PER MINUTE If DATE WELL COMPLETED PERMIT NO. REGISTRATION NO. DATE OF REPORT WE D LLER(Si atur 9/25/87 125028 10 9/29f 8 DEPT. OF ENVIORNMENTAL PROTECTION-WATER RESOURCES 10/16/2009 15:09 2033890910 AQUATEK LAB PAGE 01/01 - - Aqbatek Labs 131 Bradley Road Woodbridge, CT 06625 Water Analysis Report WATER SOURCE: 220 .LONG HILL ROAD - SOUTH WINDSOR, CT NO TREATMENT, BATHROOM SINK TO: CUONG NGUYEN DATE: 10/13/2009 39 NEWTON STREET TEST# : B1013903 HARTF'ORD, CT 06040 BACTERIOLOGICAL EXAMINATION Total Coliforms Present Absent X Fecal Coliforms Present Absent ... X RESULT p,L UNITS PHYSICAL/CHEMICAL EXAMINATION Turbidity 0 .75 5 .0 NTU Color 10 15 --- Odor N.D. 2 pH 8 .1 10 .0 - 6.4 --- Calcium 30 .4 None mg/L Magnesium 0 .7 None mg/L Hardness 78 . 9 200 mg/L Nitrate Nitrogen 4 . 1 10 . 0** mg/L Nitrite Nitrogen N.D. 1 . 00** mg/L. Sulfate 12.3 250 . 0 mg/L Sodium 12 .9 28 . 0 mg/L Chloride 14 . 1 250 . 0 mg/L Copper N.D. 1 .30** mg/L Iron N.D. 0.30 mg/L Manganese N.D. 0 . 05. mg/L CONCLUSIONS: Based on the above results, this water was safe for drinking purposes at: the time the sample was collected. Sampled, By: Michael Cunningham under the direction of Aquatek Labs. AL = Advisory Level = EPA Maximum Contaminant Level (MCL) or State enforceable standard when value followed by ** . N.D. = None Detected * = exceeds AL, see attached sheet below AL, see attached sheet David M. - Graham, Ph.D. Laboratory Director CT License #PH-0466 Woodbridge ■ Old Saybrook ■ Glastonbury