HomeMy WebLinkAboutSeptic New 1970 John Fitch Boulevard ,r
TOWN OF SOUTH WINDSOR
HEALTH DEPARTMENT
Applicati n Ti permit to install a new/repair subsurface sewage disposal system. To the Health Department,
Town of Siout Nindsor.
Fee Paidj; Date Permit Number
As a substjrface sewag disposal system installer li nsed in the State of Connecticut I
Name, Address, Telephone Number, License Number
hereby pply for a permit to construct/repair a subsurface sewage disposal system located at
%^ Ig 20 ;Z-r and owned by "��'`i �' izt Z VZ Z'n)
Street, Address, Lot Number Name
Address
Information to be supplied by��plicant:
Type of dwelling L--SiClli°._ icre If non-residential, estimated daily flow
Residential,Commercial,Etc.
Number of bedrooms Size of lot .56
Number of fixtures above basement
Tubs,Sinks,Toilets,Etc.
Number of fixtures in basement, if any ,
pp Pumped or gravity flow,
Type of water supply Sri If private,type of well
P lic-Private
Information to be supplied by Health Department:
Soil type at various levels sajd t i c cam,_, 4. ceee,?(
Percolation rate Square feet of effective leaching area required 9,00
Size of septic tank 0 Type of system '7're.. tcc
Trenches,Drywells,Etc.
Num)tier of dry wells, trenches, etc. y Distance between individual leaching
units. Distance from well on same property 957 on adjoining property 75—
Curtain drain required r v e2ay have- 7L- b.-
Yes,No
Height of system above ground water maximum groundwater Y
ledge impervious soil layer /8'"
If automatic closing is required,description
A PLOT PLAN INDICATING LOCATION OF PROPOSED STRUCTURE, WATER SUPPLY, SEPTIC SYSTEM, EM-
BANKMENTS, WATERCOURSES, PROPERTY LINES AND ALSO INDICATING EXISTING AND PROPOSED
FINISHED GRADES MUST BE SUBMITTED BEFORE THIS PERMIT CAN BE ISSUED.
THIS PERMIT IS NOT TRANSFERRABLE FROM PERSON TO PERSON OR FROM PLACE TO PLACE.
NO PART OF THE SYSTEM SHALL BE BACKFILLED UNTIL IT HAS BEEN INSPECTED AND APPROVED BY THE
SANITARIAN.
SPECIFICATION AND REQUIREMENTS AS STATED IN THIS PERMIT MUST BE MET AND ANY CHANGES MUST
BE APPROVED BY THE TOWN SANITARIAN BEFORE FINAL APPROVAL WILL BE GIVEN.
THIS PERMIT SHALL NOT BE CONSTRUED AS PERMISSION TO CREATE A NUISANCE CONDITION NOR IS
THIS SYSTEM GUARANTEE BY THE HEALTH DEPARTMENT.
Permit Received by
Z c df Date
Signature of Applicant&License umb
For Office Use Only
Permit issued by 'e Date 2—
System installed by
Final Inspection Approval �- -� Date
0 j4,
QL
tl
- - - - - --w --- h
cb
w
cJ
1540 SULLIVAN AVENUE • SOUTH WINDSOR, CONN. 06074
�IosoR•C0 AREA CODE 203/644-2511
May 22, 1980
Mr. John C. Midlin
349 Griffin Road
South Windsor, CT 06074
Dear Mr. Midlin:
Unfortunately, as determined by Mr. Stead from the firm of Peterson &
Hoffman, the finished floor elevation of your residential dwelling located
on Route 5 in South Windsor is approximately seven feet lower than indicated
on your plan, which was approved in August of 1979. Because of this, it is
impossible to keep the flow line of the leading trenches at the approved
elevations utilizing gravity flow and be in compliance with the State Public
Health Code.
At this point, you may either utilize the same septic system design,
with the 'addition of a pumping chamber to raise the effluent to the proper
elevation, or try to find an area to relocate your system. The new area
may also have to be pumped. In either case, a revised engineered plan
must be submitted for approval. If a pump is utilized, manufacturer and
model number must be indicated and size of pump chamber must be shown. If
a new area is to be used, additional observation pits must be dug in the
presence of the Town Sanitarian to find a suitable area.
If you have any questions on the aforementioned, please do not
hesitate to call me at Town Hall, 644-2511, Extension 42.
Very truly yours,
TOWN OF SOUTH WINDSOR
Robert Deptula, R.S.
Town Sanitarian
RD:bw
cc: Inland-Wetlands Commission
Donald McLaughlin, Building Inspector
CERTIFIED MAIL: #461455
STATE OF CONNECTICUT
v DEPARTMENT OF HEALTH SERVICES
BUREAU OF HEALTH PROMOTION AND DISEASE PREVENTION
July 9, 1980
Mr. Robert Deptula, R.S.
Town Hall
South Windsor, CT 06074
Dear Mr.. Deptula:
This letter is to confirm our conversation regarding subsurface sewage disposal
for the residence presently under construction on the property of John Midlin,
Route 5, South Windsor, on the occasion of our inspection of the property on
July 1 , 1980.
The house is presently under construction, but has been moved from the location
indicated on the original plan approved by this office. The house sewer eleva-
tions have been set too low, so that it is not possible to construct the leach-
ing system in fill in :the area originally proposed. As you know, most of this
property is underlain by an - impervious clay layer at a relatively shallow depth.
One possible way of constructing a gravity sewage disposal system would be to
locate the leaching system on the slope of a shallow ravine north of the build-
ing. Two observation pits were dug in this area. The upper hole showed a
depth of about 3 feet of sandy loam, underlain by clay. The lower hole showed
a depth of about 12 feet of medium loam underlain by a sandy clay. No ground
water was apparent, and it appeared that a leaching system constructed in the
area of these test holes would allow for gravity flow, and still be located at
least 50 feet from the watercourse at the bottom of the ravine.
The following recommendations were made for design of the system:
1 . 300 feet of 3-foot wide leaching trench should be used. These. trenches
would have to be in two rows along the hillside in order to allow for
gravity flow and be sufficiently far from the watercourse. Four 75-foot
long trenches could be used, extending in both directions from central
distribution boxes.
2. The invert of the upper trench should be located approximately at existing
grade, while the invert of the lower trench should be approximately 12 inches
above existing grade. This would require about 1. foot of fill at the upper
trench, and 2 feet at -the lower trench. The fill should be extended for a
distance of 25 feet beyond the lower trench to assure that sewage effluent
does .not surface. A serial distribution arrangement is recommended.
3. Before revised plans are prepared or the system is installed, it will be
necessary to run a profile of the existing sewer, septic tank and the ground
contours in the area of the proposed leaching trenches. The location and
elevation of the system should be carefully staked to assure proper construc-
tion. A revised plan, or as-built plan should be submitted.
Phone: 566-2195
79 Elm Street — Hartford, Connecticut 06115
An Equal Opportunity Employer
Mr. Robert Deptula, R.S. - 2 - July 9, 1980
South Windsor
If you have any question, or if we may be of any assistance, please contact
US.
Sincerely yours,
Theodore C. Willerford
Principal Sanitary Engineer
Preventable Diseases Division
Environmental Health Services Section
TCW/pdp
cc: Sidney H. Curtis, M.D.
Director of Health, South Windsor
STATE OF CONNECTICUT
` DEPARTMENT OF HEALTH SERVICES
79 Elm Street — Hartford, Connecticut 06115
DATE 44-53 1 t
SfimJECT: '5p COm, REVIEW OF ENGINEERING PLAN FOR A HOUSEHOLD
SUBSURFACE SEWAGE DISPOSAL SYSTEM ON CLy1�. GIZ-T`j'
TO: 'fZs�'3�,`�' ���Tv L-40-, �4 j sc,�T� t N4N13 3 cs(k.
FROM: THEODORE C. WILLERFORD, PRINCIPAL SANITARY ENGINEER
ENGINEER:. DATE RECEIVED_ �/2'� /702
REASON FOR SUBMISSION:
MINIMUM PERCOLATION RATE POORER KNEW CONSTRUCTION
!_1 THAN 30 MINUTES/INCH
REPAIR
HIGH MA=4UM GROUND WATER LEV$h }� SHALLOW LEDGE ROCK
�IITHIIR__ LY_i��
DESIGN SPECIFICATIONS:
NO. OF BEDROOMS DESIGN PERC. RATE MIN.1IN.
SEPTIC TANK J ZSb GALS. LEACHING SYSTEM �'�' - Sx3`= /G�`Z Z4-v
FILL SYSTEM �� FAT . CURTAIN DRAINS '►�1.5ty
REIC%M;DED ACTION:
APPROVAL
taAPPROVAL WITH 110MINAPROWN49 PROVISIONS NOTED ON ENCLOSED PLAN.
CONDITIONAL APPROVAL SUBJECT TO FURTHER TESTING PRIOR TO INSTALLATION AS NOTED ON
ENCLOSED PLAN.
Q APPROVAL DENIED. SITE UNSUITABLE FOR SEWAGE DISPOSAL.
APPROVAL DENIED. INSUFFICIENT INFORMATION ON PLAN.
APPROVAL DENIED. REVISE AS NOTED ON ENCLOSED PLAN AND RESUBMIT.
r(APPROVAL DENIED. FURTHER SITE INVESTIGATION REQUIRED.
C ttEvTJS_J : /ojx, Z
Y-3�Fo GZ� [h�5-ram c...c_.. t I`l c;.- �..C_!''�e-t(<�1 �! S mll-1
Gs ar sl R,-j(t'QA3
COPIES. TO: iacerely
5�IDIRDCTOR OF HEALTH U��7�' ..� � --;
SANITARIAN Y � "O 4y.P '`�S;0141 �J
QJ
ENGINEER '"ag � 7. Phone:
ONMEIUAL HEALTH SERVICES DIVI ON
OTHER - 566.2195
ggra-3e I 3
o c.!
i sb o
z
ry
O
CT'
t 2 /
-7 5/
5
NOTES SOUTH WINDSOR POLLUTION CONTROL
LOCATION ov e S
OWNER
TYPE OF WORK A i ecJ
DATE —i -- o PERMIT PIPE
INSTALLER Ca Lgjn,
INSPECTOR DRAWN BY PT