HomeMy WebLinkAboutSeptic New 00 John Fitch Boulevard 4-ow PA lb TOWN OF SOUTI4 W I N DSOR Arx. J*r
m eesrl re% BUILDING DEPARTMENT h/0
South Windsor, Connecticut
Application for Permit toGtal r Repair Individual Sewage Disposal System
Application No._ 4&t1'9 7,0/
TO THE BUILDING DEPARTMENT: Date.. . /9 /yAlf 19 740
A permit is requested for repair ordnstructio f an individual sewage disposal system concerning which the
following information is submitted:
1. Owner of Property AALAAM AW14.6s!!ft_ $_Address of Owner_A&WeNisrli, dow.4,
2. Location of Property 4;04 I/TQI* I9s.eteFJA&J Lot. No.
3. Type of Structure No. of Bedrooms
(Dwelling,Commercial Building,Store,etc.)
4. Number of Families or Persons to Occupy Premises_
5. Plumbing Fixtures: Water Closets __ _ Urinals Lavatories Bathtubs
Showers Kitchen Sinks Laundry Tubs Garbage Grinder Other
6. Liquid Capacity of Septic Tank I do* drALO.OWS Material of Septic Tank
7. Soil Conditions: Type of Soil_"navel,Clay,etc.) Maximum ground water table I9. 9 FT
8. If not served by public water supply: Distance from Owner's well from adjacent wells
9. Distance to nearest water course, drainage ditch, storm drain or embankment
10. Percolation Tests: Time for 1" drop in soil test 7 1 AVNINl&$ Classification of soil
11. Minimum square feet of effective seepage area' required
12. Leaching System: Number of trenches TNftEt 431 Lengtb@1 07 Width 67. 9 Or- Total$b.Z_ S�F`T
Other
Signature
(Licensed Installer Avg.3SS+%�j�
(Sketch showing all minimum distances and other details req below /`Eo`P!
Sys. p� �fk 4•Ne��rsy�i4.F. 872%) AOVIJAI D*r?.b CWIA-, .
Permit Issued It/viol► 19 ,By � pwil(�el4S �t.
Installation Completed, Inspected and Approved
ROGER H . WHITNEY
s
CONSULTING ENGINEER
220 WEST MAIN STREET (ROUTE 441 TELEPHONE
P. O. BOX 132 FARMINGTON 677-1210
AVON. CONNECTICUT 06001
May 28, 1970
Mr. Nevin Donahue
Allied Building Systems, Inc. Re : House Sewer
260 Tolland Turnpike Allied Building Systems
Manchester, Conn. Rt. 5, South lindsor
Dear Mr. Donahue:
The changing of the 6-inch sewer line to a 4-inch sewer line from
the building to the septic tank meets my approval providing you have in-
stalled the cleanouts every 50 feet as ,you stated.
The 4-inch line will tend to clog faster than the 6-inch line and
will therefore need these clean-outs to unplug the line.
Very truly yours,
Rog r H. Whitney,
REV s s
!:".7 cc: Mr. 2manuel W. Lucek
;..: 1
1 r
if
:^a
t1
i-.
i ROGER H. WHITNEY, CONSULTING ENGINEER Avon, Connecticut '
s
SOIL PERCOLATION TEST REPORT
DATE: April 9 1970
CLIENT: LOCATION:
Chappel Road & Route 5
r Allied Building Systems, Inc. South Windsor, Conn.
TEST CRITERIA: TEST DATE:
Conn. State Dept. of Health Aril 6 1970
ATTACHED PLAN TITLE:
sketch of Proposed Sanitary System for: Allied Building
Systems, Inc. - Chappel Road & Route 5, South Windsor, Conn. Scale: as
shown. Date: April 10, 1970 By: Roger H. Whitney, Inc.
PERCOLATION TEST SUBSOIL DATA
is TEST TEST DEPTH PERCOLATION DEPTH SOIL T Y P E
HOLE INCHES MIN./INCH INCHES
i�
DP 1 45 7.3 0 - 14 Coal dust
I` 14 - 20 Dark brown fine sand
- 20 - 26 Red sandy clay
�S 26— 52 Down fine sand some silt
li
52 - 114 Tan fine sand
R -
a
`j DP 2 40 0.6 0 - 7 Grey clay
7 - 29 Brown medium fine sand some silt
29 - III Tan fine sand
'} DP 3 N 0 T E S T 0 - 14 Grey clay
14 - 32 Brown medium fine sand some silt
32 - 118 Tan fine sand
DP 4 N 0 T E S T 0 - 36 Brown clay
4
36 - 120 Tan fine clay
3
1
I
A
6
C
t
i
1
{i
i
i
ALLIED building systems, incorporated
A PLASTICRETE SUBSIOIARY - -
260 TOLLAND TURNPIKE, BUCKLAND STATION,MANCHESTER.CONN.OBD40 TELEPHONE(203)646-0124
April 14, 1970
Building Department
Town Hall
1540 Sullivan Avenue
South Windsor, Connecticut
Attention: Mr. Harvey Levack
Gentlemen:
Enclosed please find three (3) prints each of the soil
percolation test reports and the sanitary system layout,
that we propose to use at our Chappel Road plant. The
enclosed are submitted for your inspection and approval.
We are proceeding with obtaining estimates for the install-
ation of the septic tank and the plumbing, but will not
award contracts until we have received your approval.
Very truly yours,
r"' . Av"�
Kevin B. onohue
Productio Controller
KBD:sef
oc: F. J. Lore
P. Rivers
V. Burke
PREFABRICATED CONCRETE/MEMBER MO-SAI INSTITUTE - PRESTRESSEO CONCRETE INSTITUTE
}
ROGER H. WHITNEY, CONSULTING-EN-0INL_ Avon, Connecticut
- E
SOIL PERCOLATIPN TEST REPORT
DATE: Apr?0 1471)
CLIENT: LOCATION:
Chappel Road & Route 5
t; Allied Building Systems, Inc.
South Windsor, Conn.
TEST CRITERIA: TEST DATE:
' Conn. State Dept. of Health Aril 6 1970
{ ATTACHED PLAN TITLE:
( sketch of Proposed Sanitary System for: Allied Building
Systems, Inca- Chappel Road & Route 5, South Windsor, Conn. Scale: as
shown. Date: April 10, 1970 By: ' Roger H. Whitney, Inc.
PERCOLATION TEST SUBSOIL DATA
y
TEST TEST.DEPTH PERCOLATION DEPTH S O IL T Y P E
i� HOLE INCHES MIN.JINCH INCHES
ul
is
DP 1 45 7.3 0 — 14 Coal dust,
F
14 - 20 Dark brown fine sand
20 26 Red sandy clay
262 '
5 Brown fine sand some silt
52 114 Tan fine sand
DP 2 40 0.6 0 7 Grey clay
7 19 Brown medium-fine
sand
ad numfine sand some silt-
2 - 1
DP 3 N0 TEST 0 - 14 Grey clay
14 - 32 Brown medium fine sand some silt
32 - 118 Tan fine sand
DP 4 N 0 T E S T 0 - 36 Brown clay
36 120 Tan fine clay
ROGER H. WHITNEY, CONSULTING ENGINEER Avon, Connecticut
I"
SOIL PERCOLATION TiST REPORT (Cont.)
DATE:_ 1_Q. 1970 _-
Client
R! eWMER & LOCATION:
Allied Building Systems, Inc.
Chappel Road & oute 5, South Windsor Conn.
i
GENERAL: The soil types indicated herein are classified by visual observations and the simple field
tests stated in the Unified Soil Classification System. The proportional amount of each soil type is
indicated only generally to aid in detextnining the suitability of the soil for subsurface sewage disposal
and any precautions that should be taken.
The absorption qualities of a simple test hole indicate only the qualities at the particular location
tested; whereas, a number of test holes will indicate the absorption qualities of the soil over a wide area.
It is understood that the conclusions rendered by these tests and any accompanying report do not
cover the installation of the individual septic-tank systems. The specific conditions affecting each
system may vary or be found to differ which will require adjustments prior to or at the time
of installation.
In addition to changes in seasonal water table the seasonal moisture content of the soil may cause
considerable variation in certain characteristics of the soil such as color and rt.ructurc from those
reported.
REMARKS:
The land is essentially flat for a distance of about 300 feet northeast of
-the old brick plant to where a moderate, downward, northeasterly slope begins.
This slope continues for about 90 feet and terminates at the edge of a very steep
bank.
Test pits were dug in the north corner of the open lot. The investigations
disclosed the presence of a thick layer of fine sand starting at about a 14" depth
`hole down to at least a 120" depth,
The ground water table was intercepted in test pits # 1 , 2, & 3 which puts
it at a depth of 10. 1 feet below the floor elevation of the proposed future lair.-
_atory.
The percolation rate in the brown sand was 11t in 7.3 min: while the rate in
44Ahe underlying tan sand was a very rapid rate of 1 " in 0.6 min.
I would recommend the use of leaching trendhes as an economical and feasible
method of subsurface disposal of sewage effluent.
Res`ectfully submitted,
z
Ro r H. Whitney
President
RHW/ss
TOWN OF SOUTH WI N DSOR
jr��yb BUILDING DEPARTMENT
South Windsor, Connecticut
Application for Permit to Install or Repair Individual Sewage Disposal System
Applicat' No.
TO THE BUILDING DEPARTMENT: Date �� 19
A permit is requested for repair or construction of an individual sewage dispos system concerning which the
following information is submitted:
1. wner f Property ' dress of Owner.
2. Location of Property -VC Lot. o.
3. Type of Structure No. of Bedrooms
(Dwelli5.96mraercial Building,Store,etc.)
4. Number of Families or Persons to Occupy Premises_
5. Plumbing Fixtures: Water Closets Urinals Lavatories Bathtubs
Showers Kitchen Sinks Laundry Tubs Garbage Grinder Other
6. Liquid Capacity of Septic Tank Material of Septic Tank
7. Soil Conditions: Type of Soil Maximum ground water table
(Sand,Gravel,Clay,etc.)
8. If not served by public water supply: Distance from Owner's well from adjacent wells
9. Distance to nearest water course, drainage ditch, storm drain or embankment
10. Percolation Tests: Time for 1" drop in soil test Classification of soil
11. Minimum square feet of effective seepage area required
12. Leaching System: Number of trenches Length Width Total
Other
Signature
(Licensed Ins er)
(Sketch showing all minimum distances and other details required below)
See ejti/er r s ke 4eIn.
i
Permit Issued 19 By
Installation Completed, Inspected and Approved 19 By
ROGER H. WHITNEY, CONSULTING ENGINEER
Avon, Connecticut
f y,.
SOIL PERCOLATION TEST REPORT (Cont.)
' DATE:_— _Q
LOCATION:
Allied Buildin Systems, Inc.
Chappel Road Route 5, South Windsor Conn.
a'
GENERAL: The soil types indicated ,herein are-classified by visual observations and the simple field
i tests stated in the Unified Soil Cl�ssification
System. The proportional amount of each soil type is
indicated only generally to aid in determining the suitability of the soil for subsurface sewage disposal
and any precautions that should be taken.
,ly The absorption qualities of a simple test hole indicate only the qualities at the particular location
tip tested; whereas, a number of test holes will indicate the absorption qualities of the soil over a wide area.
s It is understood that the conclusions rendered by these tests and any accompanying report do not
cover the installation of the individual septic-tank systems. The specific conditions affecting each
ti;• system may vary or be found to differ which will require adjustments prior to or at the time
'! of installation.
1 In addition to changes in seasonal water table the seasonal moisture Content
ut the soil m�ly cause
considerable variation in certain characteristics of the soil such as color rind structure front those
reported.
REMARKS:
The land is essentially flat for a distance of about 300 feet northeast of
the old brick plant to where a moderate, downward, northeasterly slope begins.
This slope continues for about 90 feet and termin a
bank. tes at the edge of a very steep
Test pits were dug in the north corner of the open lot. The investigations
disclosed the presence of athick layer of fine sand starting at about a 14n depth
hole down to at .least- a 12011 depth. .
The ground water table was intercepted in test pits # 1 , 2 & 3 which
puts
it at a depth of 10. 1 feet below the floor elevation of the proposed futurelav-
atory.
The ppercolation rate in the brown sand was 1" in 7.3 min. while the rate in
the underly
ing tan sand was a very rapid rate of 1 " in 0.6 min.
I would recommend the use of leaching trenches as an economical and feasible
method of subsurface disposal gf sewage effluent.
J
ctfully submitted,
H. Whitney
RHW/ss President