HomeMy WebLinkAboutSeptic Inspection 36 Graham Road SKIPS SEPTIC TANK SERVICE, INC.
27 Muddy Brook Road Ellington, CT 06029
CONNECTICUT RECOMMENDED MINIMUM EXISTING SEPTIC SYSTEM INSPECTION REPORT
1 PROPERTY INFORMATION
Address: 36 Graham Rd. Town: South Windsor Date: 8/1/05
Type of Dwelling or Use: Residential
Z CLIENT INFORMATION ��9�
Name: Mohammed Taleb/buyer XI C) l
Phone#: cell 794-9533
Mailing Address: 465 Buckland Hills Dr.#21113 Town: Manchester State: CT
Agent Name: Hala Hanna/Sentry ZIP: 06040
Fax Report to: 647-7650
3 INSPECTOR INFORMATION
Name: David Hoover
Company: Skips Septic Service Inc. Phone# (860)-875-2332
Mailing Address: 27 Muddy Brook Rd. Town: Ellington State: CT
ZIP: 06029
4 IMPORTANT NOTICE
THIS INSPECTION REPORT INDICATES THE PRESENT CONDITION OF THE SYSTEM BASED ON
RECOMMENDED INSPECTION PROCEDURES OUTLINED IN THIS REPORT. THE RESULTS OF THIS
INSPECTION DOES NOT GUARANTEE OR WARRANTY FUTURE PERFORMANCE. THE INSPECTION
REPORT EXCLUDES AND DOES NOT INTEND TO COVER COMPONENTS THAT ARE INACCESSIBLE
(BY REASONABLE HAND DIGGING)OR ARE OTHERWISE NOT OBSERVABLE.
5 RESULTS AND RECOMMENDATIONS
INSPECTION REVEALED(INDICATE ONE OR MORE OF THE FOLLOWING)
System functioned properly at time of inspection.
x System functioning but is not necessarily sized per today's standards, no upgrade required.
Plumbing lacks or wastewater routing problems in home.
x Need for component replacement and/or modification.
System is currently surcharged.
Evidence of prior high liquid levels in system components.
System operating at capacity undercurrent usage levels.
Sewage overflow observed, repair required under permit of local health department.
Soil testing recommended to determine expansion/repair area.
COMMENTS AND RECOMMENDATIONS FOR ABOVE CHECKED ITEMS ON NEXT PAGE
/V
13s�d
�t4i.� v,c Tzz lei
51 o�
y�4 cr sr&` oo�
,mac
/-i 6 -0
INSPECTION REPORT
Page 2
COMMENTS The sewer line from the house to the tank is flowing properly.
The 1000 gallon concrete septic tank appears structurally sound with functional baffles.
The tank is 2'below grade and needs a center access riser to meet CT health standards.
The absorption system consists of a series of pipe and stone trenches.
The house is vacant and the system is dry. There was some root intrusion found but no signs of prior high
levels.
RECOMMENDATIONS Read all of the literature provided in the green folder.
Conserve water and space out laundry.
Pump in 2 years.Skips will send a reminder.
Install center accees riser. Cost$200.00, including digging.
NOTE:The recipient of this report should discuss any deficiencies found by this inspection with the Inspector.
INSPECTION PROCEDURES
6 RECORDS AND DATA: (OBTAIN AS MUCH AS PRACTICAL PRIOR TO THE ACTUAL INSPECTION)
This information may be obtained through numerous sources, some of which is provided
voluntarily, such as, through the property owner. The inspector assumes no responsibility for
the accuracy of information provided in this manner.
Attach copies of all available records and indicate the source of such records.
RECORDS(INDICATE NUMBER OF EACH)
Permit Applications: New System: Date: Source: unknown-
Repair/After Date: Source:
Permits to Construct: New System: Date: Source: unknown
Repair/Alter: .Date: Source:
Permits to Discharge: New System: Date: Source: unknown
Repair/Alter. Date: Source:
NOTE: Lack of records or data on file does not necessarily indicate that the existing subsurface sewage disposal
system is non-compliant with installation standards.
MAINTENANCE RECORDS
Last Two Septage Pumpout Dates: unknown & Source:
Copies of Pumpout Reports Available?: Y/N Source:
LOCATION DRAWING'-(AS-BUILT)
Is a Location Drawing Available? no Y/N Source:
INSPECTION REPORT
Page 3
7 GENERAL INFORMATION
Age of System: Tank: 47 Years Leaching Fields: 47 Years
Number of People Occupying Dwelling: Currently vacant Anticipated 4
*If currently unoccupied, how long has it been vacant? ?
Number of Bedrooms?
Water Supply to Building? Well; Public Water Supply
8 WASTEWATER ROUTING
One Tank/One System yes Two or more tanks/One System no
Separate Gray and Black Water Systems no
Does more than one sewer line leave the foundation? no Y/N (indicating possible
two separate systems?)
Is there an in-home ejector pump? no Y/N
Water treatment system utilized? no Y/N If yes,does backwash discharge
to septic system? Y/N If Yes, recommend alternative.
Does kitchen sink have garbage disposal? no Y/N If yes, recommend cleaning the
tank more often.
Does basement have a sump pump? no Y/N If yes, where is it discharged?
Does the washing machine discharge to septic tank? yes Y/N If No, DYE TEST
may be necessary. If discharge is to a separate drywell or separate leaching system, is it functional?
Y/N If No, corrective action would be required.
Is there any indication that sewage bypasses the septic system? no Y/N
If Yes, DYE TEST may be necessary.
NOTE: IF DYE TEST IS NECESSARY, PERFORM IT PRIOR TO PUMPING TANK
9 SEPTIC TANK EVALUATION
Type of Septic Tank: x Single Compartment Multiple Tanks
Two Compartment Cesspool
Depth of Tank below Grade: 26" Riser: none Y/N Depth to Riser.
Tank Construction: x Concrete Plastic Fiberglass
Metal Other.
Volume of Tank: 1000 Gallons
Tank Components: Present Type Condition
Y/N Comp. Good Operable Poor
General Tank Yes concrete x
Inlet Baffle yes center x
Outlet Baffle yes center x
Effluent Filter no
lCompartment Wall no
Inlet Pipe yes F clear
Has there been any indication of previous higher than normal levels of septage in the tank? no Y/N
Depth to Liquid from inside top of tank �,. 9 inches
I
M.
AF
21.:Muddk Brook Roatl t
M BuX23 ;flli li flli
I
sePhe: !� CT Ei6a29.. �gsp)875 233 1
p 8 + n°pufrs • insfdllatwn
uvunon •
sew�t�dnun line fiostrllatYvn/c r _ _ � .r �
JO 'LOEsAT1g0Nr /- leu„`t
J 0 4Tra pp��� I ATE 1
BILLING
NAME&ADDg /
_ \ 1
ON
Pum In AMauNr
Digging �. =
Manual Snake f —-
Risers/Cover;
ti
Baffles . —
Drain Cleaning:
_4
Jetting.:
Service:Call /
i
Real:Estate Inspection
I Repair
Tax
SIGN
is �'YVe accept arecld cards d
A 1 1%2%service barge will be added ff hot
Paid th 30 days.
Ref.No:a 26D200361