HomeMy WebLinkAboutSeptic Correspondence 460 Foster Street A. J. M A C C H I ® E N I N E E R S EXECUTIVE OFFICES 44 GILLETT STREET HARTFORD, CONN.. 06105 PHONE 525.6631 A.J. MACCHI H. R. HOFFMAN ' J.J. SCHMID ASSOCIATE CONSULTANT PROF. C. W. DUNHAM April 24, 1968 Mr. William Irwin ,J )Foster Street "I South Windsor, Connecticut Dear Mr. Irwin: This is to state that a percolation test was made on Lot #2 of your property on the east side of Foster Street, South Windsor, on April 22, 1968. The location of the test hole is shown on a property map of this land prepared by Petersen & Hoffman. A 12" 0 hole, approximately 36" deep, was excavated. The material consists of 6" loam underlain by a mixture of sand, gravel and some silt. The hole was filled with water and allowed to drain out and filled a second time. The rate of drawdown after this second filling was as follows: 1" 6 Minutes 1" - 241 9 Minutes 2" - 3" 10 Minutes 3" - 4" 11 Minutes 4" - 5" 12 Minutes Very truly yours, A. J. MACCHI ENGINEERS H. FF , P. E. CC.