HomeMy WebLinkAboutWell Correspondence 1676 Ellington Road NOV-02-99 .02:07 PM P. 01
� I
�. STATE OF CONNECTICUT
DEPARTMENT OF PUBLIC HEALTH
May 27, 1999
Mr.Jeff W. Coho
Kamco Florist
1676 Ellington Road
South Windsor,CT 06074
Dear Jeff;
Here are the results I took of your well on 5/13/99. When I took the sample I noted
that you have a shallow well suction pump in your basement so I surmised that yo4
have a dug well as a source of water for your house/business.These type of pumps.
can only draw suction from a shallow 25 foot or less deep well because of standard
atmospheric pressure,vacuum characteristics,etc.
1 had concerns that your bacteriologic tests would come.back positive as dug wells
are notorious for poor bacteriological water quality.I couldn't locate your well but I
assume its over somewhere in the wetlands area bordering your property.
Mirabile dietu! Wonders of wonders your well water is fine.All parameters are Weill
within accepted standards and parameters and is quite potable for plants and
people too! You will note that the water is quite mineralized with a high hardness of
170ppm. I think this explains the excellent bacterial results. While the well itself
may be only 20-25 feet deep,it is sitting on top of a deeper artesian aquifer and its
water is flowing up from a bedrock aquifer and out of your well. Shallow
overburden(dug)wells are usually very soft with little or no hardness.
Keep these results with your house documents and if you have any questions give ;
me a call at 509-7325. I will also copy the town,Bob Deptula,so he can have this
data for his!Iles.
Sincerely,
4pa
Clifford A.McClellan,Jr.
Sanitar; Engineer 3
Water Supplies Section
cc: Bob Deptula w/enclosure
Phone: 509-7333
Telephone Device for the Deaf (860) 509.7191 i
410 Capitol Avenue -MS# 5.1 VAT..
P.O, Box 340308 Hartford, CT 06134
An Equal Opportunity Employer
NOV-02-99 .02 :07 PM p_ 02
G
STATE OF CONNECTICUT
Department of Public Health
Division of Laboratory Services INRtIKF 22246924 A00152 1 0 W0
10 Clinton St,
P.O.Box 1699
Hartford,Cr 06144
TELEPHONE(860)509-8500 132SOUTH WINDSOR
RAMCO FL.OR I STS I
F RT 30
SOUTH WINDSOR CT 06074
DPH—WSS—COMMUNITY SYSTEM
P. RITSICK MS 51WAT
P.O. DOS: 340308 05/13/ 9 05/13/9 03/24/'
HARrFORD CT 06134 J 1i =30 12x55 07.43
FINAL REPORT CONSTRUCTION EROSION1
SAMPLING POINT: WELL 01 I
:,,,y, ,lm1IN1A4ki�iAfo3ikiN69tmt {t :i:, :Cl7flR.i C. MCCLELLAN T'I`71ti�'i�'�`ryi':""""'';_r •'•:•
PRIVATE WELL
DATE/TIME ANAI.,YZED 5/13/99 1315
ANALYZED I3Y RG I
ANALYTICAL METHOD COLILERT / PLATE COUNT
TOTAL COLIFORM ABSENT PER 100 ML
CONF, TOTAL COLIF'ORM ABSENT PER 100' ML
ESCHERICHIA COLI A13SENT PER 100 ML
STANDARD PLATE COUNT 1 /ML OR G
APPARENT COLOR 7
TRUE COLOR TRUE COLOR LESS THAN OR EQUAL TO APPARENT COLOR.
ODOR 0
TURBIDITY <0.2 i
PH 7.6
-I MMOhl I A <0.05
+t** uN*j' `M P& •UNI,.E89 NOTED . ;• :;>'
ALKALINITY $6.
HARDNESS 170.
CHLORIDE 42.
NITRATE 3.4
NITRITE <0.05
DETERGENT CMPL 1( <0. 1
IRON 0.0z
MANGANESE 0.00
solo IIJM p DIRECT 17.
• :��I IvM�I. •.1.1.'if r".
5301AR) I {t 'I :fit,gat!j:
Lu7 Al 4�
CORM NO.OL-GA REV,7.97
I
1
�O �N ACC090
PHOEIVIXO,-at.
U -
Environmental Laboratories, Inc. S
587 East Middle Turnpike,P.O.Bog 370,Manchester,CT 06040
Tel.(860)645-1102 Fax(860)645-0823
FOR: Mr.David A.Patria
565 Nevers Rd.
Analysis Report South Windsor,CT 06074
June 16, 2005
Sample Information Custody Information Date Time
Matrix: WATER Collected by: 06/08/05 7:00
Location Code: SPECIAL Received by: LB 06/08/05 9:44
Laboratory Data
Client ID: 1676 ELLINGTON RD.,SOUTH WINDSOR OUTSIDE FAUCET Phoenix I.D.:AG45879
Analysis Maximum Maxim
Anal
3' Contaminant Advisory Detection Measurement
Parameter Result Level Level Limit Units
Total Coliforms Absent 0/Absent 0 /100mis
E. Coli Absent 0/Absent 0 /100m1s
Nitrite as Nitrogen BDL 1 0.01 mg/L
Nitrate as Nitrogen 3.3 10 0.05 mg/L
Chloride 46 250 3.0 mg/L
Chlorine Residual 0.04 0.02 mg/L
Iron 0.025 0.3 0.002 mg/L
Hardness(CaCO3) 175 200 0.10 mg/L
Manganese 0.006 0.05 0.002 mg/L
Sodium 18.2 28 0.10 mg/L
Odor BDL 2 1 T.O.N.
pH 7.91 6.5-8.5 0.10 pH Units
Sulfate 36 250 3.0 mg/L
Turbidity 0.24 5 0.10
Calcium 57.7 u.010 mg/L
Color BDL 1 P.C.U.
Magnesium 7.44 0.01 mg/L
Explanation: BDL = Below Detection Limit (less than the the value in the detection level column,
which is the lowest amount the laboratory can detect and report.) NL = No Limit(no
limits established for this parameter.)
This sample represents a potable(drinkable)water supply for the parameters tested.
If there are any questions regarding this data,please call Phoenix Client Services at extension 200.
A UL
Shiller, Laboratory Director
Phyllis4
i
RECEIVE June 16,2005
F
JUN 2 0 2005
SOUTH WINDSOR y
ENGINEERING DEPT
SpurN St
x F �-0� O-P sia�
O
c
1540 SULLIVAN AVENUE • SOUTH WINDSOR, CT 06074
OR-CO TELEPHONE(860) 644-2511
June 7, 2005
Mr. David Patria
566 Nevers Road
South Windsor, CT 06074
Dear Mr. Patria,
This is to confirm our recent conversation regarding your property at 1676 Ellington
Road in South Windsor.
Due to the fact that your existing well and septic system are closer than present day
standards allow it was discussed and agreed upon that you would submit to the Health
Department water testing results from the well to determine water quality every six
months. Bacterial and routine chemical analysis is sufficient.
It was also discussed and agreed upon that b the end f
9 P o a three year period from.
Y
Y
occupancy, you would either connect to the public water, public sewers, or both.
If you have questions please feel free to call me at (860) 644-2511 extension 248.
Yours truly,
Robert Deptula, R.S.
Environmental Health Officer
RD/cm
Cc: Michele Lipe, Assistant Director of Planning
Chris Dougan, Chief Building Official