Loading...
HomeMy WebLinkAboutSeptic Correspondence 1096 Ellington Roa 10*N Sf4 7-au� sou V G U m � 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CT 06074 f�OSoa-CO .TELEPHONE (860) 644-2511 PERMIT TO DISCHARGE Approval is hereby given to 1096 Ellington Road,in accordance with the Public Health Code, Section 19-13-13103e(h)to discharge to a subsurface sewage disposal system located at 1096 Ellington Road,in the town of South Windsor, CT,that will receive treated domestic sewage from a: Four(4)Bedroom residence Permitted Volume/Design Flow=600 Gallons per day *In order to provide a sufficient factor of safety, it is recommended that the average daily discharge not exceed 2/3 of the design flow or 300 gallons per day. Operation and Maintenance: The septic tank shall be inspected regularly and cleaned as needed but not less frequently than every five years. The septic tank has an effluent filter. Effluent filters require periodic cleaning.Failure to clean the filter could result in a backup of sewage into the building or effluent breakout. Special Requirements and Restrictions: 1. Wastewater backwash from a water treatment P q (backwash) system cannot discharge to the subsurface sewage disposal system. 2.Use of a kitchen garbage disposal is not recommended. 3. Signs of malfunction or failure should be addressed. Exceptions: Date of Final Inspection: October 5,2009 Inspected by: Robert De Vito,R.S.Environmental Health Officer Signature• Date: SAND GRAVEL Quality Washed Sand&Stone Since 1917 SOIL GRADATION REPORT Date: 08/1/2009 Gradation ASTM D-422 Project: Dunning Washed Concrete Sand Project Number: N/A Client: Various Report Number: 09-105 Use: Concrete Spec A : ASTM C-33 Source: Pile GRADATION RESULTS Sieve# % PASS SPEC- A (#4) 96.79 95 * 100 (#8) 83.3 80 * 100 (#16) 69.49 50 * 85 (#30) 53.29 25 * 60 (#50) 28.55 10 * 30 (#100) 7.57 2 * 10 (#200) 0.82 0 * 5 Complied with Spec A: YES Soil Description : Light Yellow/Brown Sand -Trace fines _ Sampled by: Anthony Moura Tested By: Brian Brooks Reviewed By: Blair Crane P- yaLy r: i )774-4wdb SOLD BY DATE s(j i � 1 4 NAME P. ADDRESS PHONE I. F CITY r!`S ❑ CASH ❑ CHARGE ❑ MERCHANDI^3E RETURNED' ❑ C O.D.. ❑ PAID OUT ❑ PAID ON ACCOUNT • t QTY. DESCRIPTION PRICE AMOUNT ; 2 :A 3rl+ f / 4 t• 6 ti E 9 10 1 P ' i I � 12 13 �:. ` 14 � 15 WE E T 3D8 WE AT TKE COSTOWJM RISK WE:ARE NOT W?SPONSISU FOR aiAA UIE TRAY MAY RE^BuLT 16mhmm n 0?4 m.,:..1 j Kus AP9OC«'k E TRUMUG RECEIVED B t i TOTAL ^ry A ]IkrY.4P' 'IrA-%r Ir w° 1540 SULLIVAN AVENUE• SOUTH WINDSOR, CT 06074 r�OsoR•co TELEPHONE(860) 644-2511 Septic System As- Built Plan Street Address D b '4j Date Permit Number New Septic System air of Septic System Alteration of System Number.of Bedrooms or Design Flow of Building Type of system installed (e.g.stone trenches,infiltrators,galleries) Square footage of system:Total length _Widthy Effective Area 0 C� Capacity of Tank SW New Existing 000 pum Length of house sewer pipe��� S�,� �ltj q elz j'Tilaai Minimum distance between septic tank and foundation Minimum distance between leaching field and foundation Minimum distance between sewage system and nearest well Public water supply Minimum.distance between leaching system and property boundary Curtain drain required? Yes No Minimum distance from leaching field to drains (curtain drain,foundation,stormwater, etc.) 1 Septic System As- Built Plan Address , 4-13 N o Date /() S D 7 Location of System L a AC)kS .(N, S, E,W, front,back side of house) Draft a substantially correct drawing showing separation distances of the septic system installation. Include all of the following information to provide an accurate record of the entire system location: At least two.sides of the building nearest the system, septic tank,house sewer,distribution boxes, trench ends,dry wells, curtain drain,potable watersupply wells and any other features affecting the system and its location. Installers Nam , Installers Address /Z (,�, Oyu (street, city,state and zip code) 5C-kv 0 tl low P LY b Distance from corner A I Distance from corner B / Distance from corner C Distance from corner D q . ��� • (`�'� 1 `�.��� nos �y �'a �'��'S , -?Otq ort/ Y'q 11 c Y--1 9 l a (V �-S r v v J ' cJ �� tt • S( C�S \ �ti cg r PA TOWN OF SOUTH WINDSOR ALTH DEPARTMENT Application for permit to install a new/ ep r subsurface sewage disposal system. To the Health Department, Town of South Windsor. Fee Paid Date Permit Number s a subsur ace sewage disposal xstem installer licensed in the State of Connecticut, I Name, Address, Telephone Number, License Number hereby apply fortL ae it to construct/repair a subsurface sewage disposal system IQcated at C)5 c �l �r►S'fa�n rcy and owned by nnn4c., ndbldne,l` ,% Street, Address, Lot f4umber Name CAym1 _ Address Information to be supplied bXApplic�nt: Type of dwelling Z!S) �A If non-residential, estimated daily flow Residential,commercial,Etc. Number of bedrooms 3 Size of lot Number of fixtures above basement __/1,, �1 Tubs,Sinks,Toilets,Etc. Number of fixtures in basement, if any T�r��� r Pumped or gravity flow, Type of water supply G rk N' d . If private,type of well Public- rivate Information to be supplied by Health Department: Soil type at various levels Percolation rate Square feet of effective leaching area required Size of septic tank Type of system Trenches,Drywells,Etc. Number of dry wells, trenches, etc. Distance between individual leaching units. Distance from well on same property on adjoining property Curtain drain required Yes,No Height of system above ground water maximum ground water , ledge , impervious soil layer If automatic closing is required,description I A PLOT PLAN INDICATING LOCATION OF PROPOSED STRUCTURE, WATER SUPPLY, SEPTIC SYSTEM, EM- BANKMENTS, WATERCOURSES, PROPERTY LINES AND ALSO INDICATING EXISTING AND PROPOSED FINISHED GRADES MUST BE SUBMITTED BEFORE THIS PERMIT CAN BE ISSUED. THIS PERMIT IS NOT TRANSFERRABLE FROM PERSON TO PERSON OR FROM PLACE TO PLACE. NO PART OF THE SYSTEM SHALL BE BACKFILLED UNTIL IT HAS BEEN INSPECTED AND APPROVED BY THE SANITARIAN. SPECIFICATION AND REQUIREMENTS AS STATED IN THIS PERMIT MUST BE MET AND ANY CHANGES MUST BE APPROVED BY THE TOWN SANITARIAN BEFORE FINAL APPROVAL WILL BE GIVEN. THIS PERMIT SHALL NOT BE CONSTRUED AS PERMISSION TO CREATE A NUISANCE CONDITION NOR IS THIS SYSTEM GUARANTEED BY THE HEALTH DEPARTMENT. Permit Received by Date eq S n ure of Applicant tLicense Number For Office Use Only Permit issued by Date System installed by Final Inspection Approval Date Town of South Windsor Town: INVESTIGATION FOR SEWAGE DISPOSAL SYSTEM Owner: 4 Date: Location: Soil Tests Observed By PERCOLATION TESTS Hole# Pit# Hole# Pit Test Pit Depth Presoak D hours- Presoak Presoak hours Ledge Seepage Depth / '' Mark�rl70;Sr Depth Mark Mottling Roots D L De th Observation Rate min/in Rate min/in Test Pit Depth Test Pit Depth Ledge --�C7 Seepage / Ledge Seepage Mottling Roots AJA Mottling Roots Depth Observation Depth Observation L C) Property I Location Date LrtA �- b� d \ ?�"� I � IBEX r 3 Srrr�!�S I LOCATION DRAWING ` Special Conditions Conclusions System design larger than 2,000 g.p.d. Suitable for sewage disposal Water supply watershed Possible seasonal high groundwater Unsuitable for sewage disposal Watercourse, marsh or pond Possible seasonal flooding Additional investigation required Limited suitable area Excessive slope (over 25%) Retest during wet season Marginal soil (less than 5 ft) Shallow ledge (less than 5 ft) Monitor groundwater thru wet season Underlying tight soil (less than 4 ft) Other Engineer's plan required Testing For: New Lot/System Repair/B100a/Other Design recommendations J9I—,M 7-6 lie 5a&n e O / hLeAI� �FPT rDA, i?eU �c�1 �e�/w 92 e aAQc ear L H-w 2 2 /_ t� (A r T — vc-s w o 0 Pr D a-,F- cQ h3 d °1 /%N 1?D 6.t �! / ,ej9&�• 7�> Investigated by: Title: Date