HomeMy WebLinkAboutWell Correspondence 668 Ellington Road SOS N Sfq
a
0
1540 SULLIVAN AVENUE • SOUTH WINDSOR, CONN. 06074
r�oSOR,co AREA CODE 860/644-2511
January 15, 2004
Grace Scyz
668 Ellington Road
South Windsor, CT 06074
Dear Ms. Scyz,
Enclosed is a copy of the laboratory analysis of your well water, which was tested at the
State Health Department laboratory at your request.
It was tested for any indication of contamination of a leaky oil tank.
There was no indication of any contamination.
Yours truly,
Robert Deptula, R.S.
Environmental Health Officer
RD/cm
STATE OF CONNECTICUT ........ .......... ...........:�.���!. �:..:::......::::.:...;. :�.:.;::.:.;;..:��G�:
NR:668E 16135354 S06074 0 1
Department of Public Health ,,...::.:....:;......::.:::..........:......<:>:<:•>:•;:•;:;.::.;:.:;:.;;;:<.;
Division of LaboratoryServices ..... :.::::::;:•>:•>;:•::.:�;:«.;:•::•>:.;:.;:.:.:.;:.;:.;:.:
..:......................:...........
10 Clinton St. 132SOUTH WINDSOR
P.O.Box 1689 SCYZ
Hartford,CT 06144
Telephone(860)509-8500 668 ELLINGTON
SOUTH WINDSOR CT 06074
ROBERT DEPTULA, SANITARIAN
1540 SULLIVAN AVE •:.................................:::::.�::..�.�:.:::::.:.::.�::.�: R.::.>:
TOWN HALL 12/17/03 12/17/03 01/09/04
SOUTH WINDSOR CT 06074 09:10 11:49 08:53
;.: FINAL REPORT
EAKY OIL TANK NEXT DOOR
::::::::..:::::::::::::::......... #T .::::::...................:.::::::::::::.:::::::::.:.......................................... :........................
SAMPLING POINT: OUTSIDE FAUCET
COLLECTOR: DEPTULA, R TITLE: RS
PRIVATE WELL TREATMENT:
DATE ANALYZED 12 26 03
--------------------------------------------------------
ANALYTICAL METHOD: EPA METHOD 524.2
MEASUREMENT OF ORGANIC COMPOUNDS IN WATER BY
CAPILLARY COLUMN GAS CHROMATOGRAPHY/MASS SPECTROMETRY.
--------------------------------------------------------
EPA 524.2 FINAL RESULT:
COMPOUND QUANTITY (UG/L)
BENZENE ND
BROMOBENZENE ND
BROMOCHLOROMETHANE ND
BROMODICHLOROMETHANE ND
BROMOFORM ND
BROMOMETHANE ND
N-BUTYLBENZENE ND
SEC-BUTYLBENZENE ND
TERT-BUTYLBENZENE ND
CARBON TETRACHLORIDE ND
CHLOROBENZENE ND
CHLOROETHANE ND
CHLOROFORM <0.5
CHLOROMETHANE ND
2-CHLOROTOLUENE ND
4-CHLOROTOLUENE ,ND
DIBROMOCHLOROMETHANE _ ND
1,2-DIBROMO-3-CHLOROPROPANE ND
1,2-DIBROMOETHANE ND
DIBROMOMETHANE ND
1,2-DICHLOROBENZENE ND
1,3-DICHLOROBENZENE ND
1,4-DICHLOROBENZENE ND
DICHLORODIFLUOROMETHANE ND
1,1-DICHLOROETHANE 'ND--
CONTINUED ***
FORM NO. OL-6A REV.3-00 100
STATE OF CONNECTICUT
NR:668E 16135354 506074 0 2
Department of Public Health :»::>::>::>::ss::>::>::>::::»::;::::;::;>::;::;:;:::>::::>::>.:.....:.....::..:.:....::•:::>:<:>::>;::>:>::>:«;»:»:::<:::>::>:;:>::>::>:::
Division of Laboratory Services
:::>::>::ll�atl#3'Tyr. Ea€z:::»::»::>::::>:>:»::»>::>>::::>::>::::>::<::>::>:
10 Clinton St. 132SOUTH WINDSOR '
P.O.Box 1689 SCYZ
Hartford,CT 06144
Telephone(860)509-8500 668 ELLINGTON
SOUTH WINDSOR CT 06074
ROBERT DEPTULA, SANITARIAN
1540 SULLIVAN AVE ::..............:.:::::::::..:::::::.::::.::..::::::..::::::::.:.:::::::::::::..::.
TOWN HALL 12/17/03 12/17/03 01/09/04
SOUTH WINDSOR CT 06074 09:10 11:49 08:53
> ? tkl ` >
FINAL REPORT EAKY OIL TANK NEXT DOOR
1,2-DICHLOROETHANE ND
1,1-DICHLOROETHENE ND
CIS-1,2-DICHLOROETHENE ND
TRANS-I,2-DICHLOROETHENE ND
1,2-DICHLOROPROPANE ND
1,3-DICHLOROPROPANE ND
2,2-DICHLOROPROPANE ND
1,1-DICHLOROPROPENE ND
CIS-1,3-DICHLOROPROPENE ND
TRANS-I,3-DICHLOROPROPENE ND
ETHYLBENZENE ND
HEXACHLOROBUTADIENE ND
ISOPROPYLBENZENE ND
4-ISOPROPYLTOLUENE ND
METHYLENE CHLORIDE ND
METHYL T-BUTYL ETHER <0.5
NAPHTHALENE ND
PROPYLBENZENE ND
STYRENE ND
1,1,1,2-TETRACHLOROETHANE ND
1,1,2,2-TETRACHLOROETHANE ND
TETRACHLOROETHENE ND
TOLUENE ND
1,2,3-TRICHLOROBENZENE ND
1,2,4-TRICHLOROBENZENE ND
1,1,1-TRICHLOROETHANE ND
1,1,2-TRICHLOROETHANE ND
TRICHLOROETHENE ND
TRICHLOROFLUOROMETHANE ND
1,2,3-TRICHLOROPROPANE ND
1,2,4-TRIMETHYLBENZENE ND
1,3,5-TRIMETHYLBENZENE ND
VINYL CHLORIDE ND
M,O,P-XYLENES (TOTAL) ND
NOTE: ND = NONE DETECTED
METHOD DETECTION LIMIT IS 0.5 UG/L FOR ABOVE
COMPOUNDS.
------ ** END OF REPORT **