HomeMy WebLinkAboutSeptic New 66 Edgewood Drive FEE
Fe
TO THE BUILDING DEPARTMENT Application No. 7 J.r
TOWN OF SOUTH WINDSOR Date ,� g{
I hereby apply for permit to build a sewage disposal system for a
(Residence , boarding house, hotel , etc.)
Owned of64
�1� /�/f �s� CGyZ��
And located at /
To be built by,�L�U%/� s0/� ofST
in accordance with detailed information stated below.
Signed r
(Applicant)
GENERAL INFORMATION
Z . Estimated population of premises (present)L,rfR/%Gf (future)
F 2. Description of premises (including number of bedrooms)
No. Fixtures
(Above basement): Water Closets 2- Urinals Lavatories
Bath tubs / Showers f Kitchen Sinks / Laundry Tubs
Garbage Grinder List basement fixtures 9�&A/Z Cyirs -4 P7e rc s
3. Water Supply Kind of Well
(Public, well , spring, cistern)
Location of well and underground water piping
Method of obtaining or storing supply
(Pumps , tank, etc.)
4. Character of soil at proposed location of leaching system, including depths of
various strata �
(sand, loam clay , hardpan, r k c. --Use test pits.)
5. Elevation of highest ground water
(with reference to both present & future grade)
h
of proposed system (Furnish drawings of same , with plot plan showing
Ong location, size, grade and material of house sewer and locations
,,JLtnd or surface water drains , wells and bodies of surface water.)
Septic Tank
Dimensions[JO X 5 4/-i! YX Capacity below flow line ��K:2 ff
Inlet and outlet arrangementsf}��L.�"
Facilities for cleaning 't3_ Distance from dwellings on same
property /3-r on adjoining property 'V;Z t
Automatic Dosing Apparatus , if any (describe)
Soil Absorption System
If cesspools , No. diameter ft.; depth below inlet ft.
If tile field or leaching trenches , total length is I.ZJ ft.
Width of trenches-'.1' _ft. , depth of broken stone or screened gravel �`� ft.
Stone or gravel will be covered by Distance between
(tar paper, salt hay)
trenches ft. Distance from water supply on same property J®
on adjoining property 7�i
Secondary Treatment, if other than soil absorption.
Describe in detail and locate on map
System was designed by �//� ����//� ��� �� c-;
Above information furnished by z ��� s
No discharge of sewage or sewage effluent into any watercourse should be permitted
without approval of the State Department of Health and State Water Commission.
_ryuZ_-i L ,�i2T l"'•, ''IFttkf% !t 2 SIcS.'iC71 ;i ^1kYA.C.F(tT.5LSS9y ,3 t.. E4 j --�
a
r
PRIMUS & WELTI ENGINEERS
Glastonbury, Conn.
00
.G Y 37z ,L d T 7N o L d.t 370
/ a
IOD
+4o
o 3
i
q2 ,
�. A S
C T Nt
S o tl T l �n( r N Sea rr
sc `L FI/z,F To 0 oRRSF SRN
FOUNDATION CHECKED , I
DATE SCAL 9 l a CERTIFIED SUtsTANT1AL.I.Y OaRREcT
t
STONED DATt 1�'.31- 5 (O 'Z-