Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Well New 552 Deming Street
PERMIT NUMBER CPR-8 Rev.7/95 FOFi oe.o r a • . onau a��� J STATE OF CONNECTICIIT � 22 Go �,Mate�j DEPARTMENT OF CONSUMER PROTECTION I tj ©GO`6 7 T REAL ESTATE&PROFESSIONAL TRADES DIVISION WELL DRILLING:PERMIT J4N J 0 jqg j 165 Capitol Avenue,Hartford,Connecticut 06jL 66 LOCATION OF WELL (Town) . (Street) (Lot Number) S. WINDSOR 552 DEMING ST. (Gary Drown) ACCf# # 3 98 OWNER OF WELL a INDIVIDUAL BUILDER OTHER(Specify) 654-6334 OWNER'S ADDRESS DONALD PULFERT 55 NEELANS RD. , ENFIELD, CT. 06082 Est No.of PROPOSED n DOMESTIC BUSINESS FARM El TEST People being USE OF ESTABLISHMENT WELL served. WELL SUPPLY INDUSTRIAL AIR O Q CONDITIONING STHER 3 SKETCH OF WELL LOCATION Locate well with respect to at least two roads,showing distance from intersection and front of lot location of lot to at least two roads Well location on to and to house(if present Indicate North tip 0 Approximate number of feet from well to nearest source of possible contamination: Sanitary Sewers The undersigned is aware that upon completion of the well,a"Well Completion Report`containing construction details and information required under Section 25-131 of the 1969 Supplement to the General Statutes must be sent to the owner,the Department of Consumer Protection and the Water Resources Commission on the form provided by the agency. This-permit is not valid until all information is filled in and it has been counter-signed by ftRi of Health or h1p%@gent. P ICANT "natu APPLICANTS ADDRESS REGISTRATION NO. P.O. BOX 406, WILLINGTON, CT. 42 BY(Town Health Officer"Agent? DATE ROVED ❑ REJECTED REMARKS ®� / RETURN THIS COPY TO DEPARTMENT OF CONSUMER PROTECTION 6PR-9 Rev.7/9.5 .. Do'NOT fill-in STATE OF CONNECTICUT STATE WELL NO. DEPARTMENT OF CONSUMER PROTECTION REAL ESTATE&PROFESSIONAL TRADES DIVISION • OTHER NO. WELL DRILLING COMPLETION REPORT 165 Capitol Avenue,Hartford,Connecticut 06106 OWNER NAME ADDRESS DONALD PULFERT 55 NEELANS RD. , ENFIELD, CT. LOCATION (Ab•s&deaf) (Town) (LONumber! OF WELL 552 DEMING ST. S. WINDSOR (GARY DROWN) X DOMESTIC BUSINESS FARM TEST PROPOSED ESTABLISHMENT 11 WELL USE OF WELL ❑ PUBLIC a INDUSTRIAL a AIR Q OTHER SUPPLY CONDITIONING (Speck) DRILLING © ROTARY AI COMPRESSED EQUIPMENT PERCUSSION PERCUSSION 0 (Specify) CASING LENGTH(feet) DIAMETER(Inches) WEIGHT PER FOOT DRIVE SHOE WAS CASING GROUTED? DETAILS 40- 6 17.00 J© THREADED WELDED YES ❑ NO ® YES ❑ NO YIELD TEST a BAILED Q PUMPED ® COMPRESSED AIR HOURS 8 YIELD(GPM) 7 WATER MEASURE FROM LAND SURFACE-STATIC(Specify feet) DURING YIELD TEST(feel) Depth of Completed Well in feet LEVEL 30 - 275 305 MAKE LENGTH OPEN TO AQUIFER(test) SCREEN DETAILS SLOT SIZE DIAMETER(indws) IF GRAVEL Diameter of well GRAVEL SIZE(Inches) FROM(feet) TO(feet) PACKED: indud V pravet Palk (ind»s) DEPTH FROM LAND TO SURFACE FORMATION DESCRIPTION Sketch exact Iccation of well with distances,to at least two FEET TO FEET Permanent landmarks 0 7 Topsoil & Sand 7 30 Gravel & Clay 30 305 Bedrock ooll If yield was tested at different depths during drilling,list below ('w, FEET GALLONS PER MINUTE a � DATE WELL COMPLETED PERMIT NO. REGISTRATION NO. — DATE-OF REPORT _ _ ___ _ft") 1/7/98 184322 42 1/13/98 ImLA AGENCY Columbia Environmental Laboratory Drinking Water Analysis Don&Doris Pulford STATE OF CONNECTICUT 55 Neelans Road DEPARTMENT OF HEALTH Enfield, CT 06082 CERTIFICATION NUMBER PH-0514 January 29, 1998 RE: Lab No. 9801123 SAMPLING LOCATION: 552 Deming Street, South Windsor, Connecticut SAMPLING/DELIVERY TIMES: 1330/1645 Laboratory Sampled 1/27/98 STANDARD WATER ANALYSIS STATE OF CONNECTICUT TEST RESULTS RECOMMENDED/MAXIMUM LEVELS pH UNITS 7.9 6.5-9.0 RECOMMENDED RANGE COLOR UNITS 5 15 RECOMMENDED MAXIMUM ODOR 0-5 0 (none) 3 RECOMMENDED MAXIMUM TURBIDITY NTU 5.8 5 RECOMMENDED MAXIMUM ALKALINITY mg/L -- NO RECOMMENDED LEVEL CHLORIDE mg/L - 23 250 MAXIMUM ALLOWABLE 0-60 soft, 61-120 mod. hard HARDNESS mg/L 118 121-180 hard, >181 v. hard NITRITE AS N mg/L <.005 1.0 MAXIMUM ALLOWABLE NITRATE AS N mg/L 8.3 10.0 MAXIMUM ALLOWABLE DETERGENTS mg/L <0.5 0.5 MAXIMUM ALLOWABLE IRON mg/L 0.29 0.3 RECOMMENDED MAXIMUM MANGANESE mg/L .015 .050 RECOMMENDED MAXIMUM SODIUM mg/L 7.5 28 RECOMMENDED MAXIMUM COLIFORM BACTERIA 0/100 ml 0/100 ml MAXIMUM ALLOWABLE Sulfate mg/L 28 1,2-Dibromoethane(EDB) ug/L <.02 0.10 Max.Allow.' For the parameters analyzed,this is a satisfactory potable drinking water supply. If you have any questions,please feel free to call. rY truly Yours e -C. Burrell - - 2 Lakeview Park West Columbia, CT 06237 Telephone: (860) 228-0329