Well Correspondence 324 Deming Street
February 10, 2009 Certified Mail: 7008 0150 0002 6256 2914 Robert&Lucilli 324 Deming Road South Windsor, Ct 06074 Re: Connection to public water Dear Mr. &Mrs. Lucilli: In March of 2008, you were notified of the opportunity to take advantage of the DEP Grant funds available to connect to public water. As of the writing of this letter,this office has not been notified of your intentions. This correspondence, written at the request of the Department of Environmental Protection, is your final notice. A lack of response will indicate that you do not wish to have your home connected to public water. If you choose to connect, the fees associated with connecting to the public water supply will be paid for by a DEP potable water supply grant. The grant will pay for all costs associated with the connection with the exception of any frontage fees. Please respond to this department no later than 27a'of February so that we may notify the DEP of your decision. If you have any questions,please call me at 644-2511, extension 248. Sincerely, Robert De Vito Environmental Health Officer Cc: MaryAnne Danyluk Ct. DEP, Remediation Section Bureau of Waste Management 79 Elm Street Hartford, CT 06106-5122 .�OYI N C + w� 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CT 06074 l�OSOR-CO TELEPHONE (860) 644-2511 March 28, 2008 CERTIFIED MAIL Rob�avin 324 Beelzebub Roa Sout in sor, CT 06074 Re: Connection to Public Water Dear Mr. &Mrs. Davin: As you know,Modified Water Supply Order WC-4458 and Water Supply Order WC-4949 has afforded you the opportunity for your residence to connect to the Public Water Supply. A review of our files indicates that you have not taken advantage of this opportunity. If we are incorrect,we would appreciate it if you would contact us and assist us with updated information. If you have not taken advantage of this opportunity I would like to remind you that the State requires three bids from three separate contractors approved by the local water utility. An itemized statement from each contractor should state their fee for the work proposed to connect a private residence to public water which includes the following requirements: 1. Cost for the abandonment of the well based on Consumer Protection's guidelines. 2. Cost for lateral connection to the residence from the water main. 3. Three Linear frontage fee to be waived. 4. Cost for the meter horn. 5. Cost for the interior plumbing conducted inside the residence. 6. Reseeding the lawn and returning the property to its original state. 7. Any permits and fees required by the contractor. The State will choose the contractor to conduct the work. Upon approval of the work proposal the State contacts the property owner to notify the selected contractor to do the work. ,C�y1N Sf4( Town O-PsotdA ?di� m 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CT 06074 f�Osoe•co TELEPHONE (860) 644-2511 Page 2 Connection to Public Water March 28, 2008 The three contractors you should contact are Folsom Construction, Olender Construction, and Wood Construction. When you have obtained the bids please forward them to this office for review. Failure to respond within ten (10) days of receipt of this correspondence will be interpreted as a"no" answer, that you do not wish to be connected to the public water. If you have any questions, I can be reached at 860-644-2511, extension 248 Very truly yours, Robert De Vito, R.S. Environmental Health officer SSW N Sf4 WSI,� O-P siou� ?d&U&Ot s 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CONN. 06074 soe•co`' AREA CODE 860/644-2511 November 1, 2005 CERTIFIED MAIL 7004 1160 0007 4128 1495 Lucille & Robert Davin 324 Deming Street South Windsor, CT 06074 Dear Mr. & Mrs. Davin, As you are aware, a sample of your well water was collected and delivered to the State Health Department laboratory to be analyzed for several contaminates. Two of these were detected in levels above the state action levels. EDB was present at 0.08 parts per billion. The standard is 0.02 ppb. Also, 123TCP was detected at 0.1 ppb, the standard is 0.05. Since these levels are above the action levels, the State will provide you with bottled drinking water. I am required to collect a confirmatory sample which will be done in the next several days. Using this latest data, a determination of eligibility for water connection will be made. If you have any questions please contact me at the South Windsor Town Hall at 644- 2511 ext. 248. Yours truly, "0 Robert Deptula, R.S. Environmental Health Officer RD/cm CC: MaryAnne Danyluk CT DEP, Remediation Section, Bureau of Waste Management 79 Elm Street Hartford, CT 06106-5122 STATE OF CONNECTICUT • Department of Public Health NR:D2 18020691 S06074 0 Division of Laboratory Services 10 Clinton St.,P.O.Box 1689 INFORMATION Hartford,CT 06144 CONN.CLINICAL TESTING LICENSE#CL-0197 DAV I N TELEPHONE:(860)509-8500 324 DEM I NG ST SOUTH WINDSOR CT 06074 ROBERT DEPTULA, SANITARIAN 1540 SULLIVAN AVE • •• TOWN HALL 10/17/ 5 10/17ls5 10/24/ L SOUTH WINDSOR CT 06074 10,145 15:07 10. 19 REPORT COMMENT TEST(S) RESULT(S) COLLECTOR: DEPTULA R TITLE: RS PRIVATE WELL *** DATE ANALYZED 10/20/05 --------------------------------------------------------- EPA METHOD 504. 1 MEASUREMENT OF 1 ,2-DIBROMOETHANE (EDB) , irZ-DIBROMO- 3-CHLOROPROPANE (DBCP) AND 1 ,2,3 TRICHLOROPROPANE ( 123TCP) IN DRINKING WATER BY MICROEY.TRACTION AND GAS CHROMATOGRAPHY WITH ELECTRON CAPTURE DETECTION. -------------------------------------------------------- ****QUALITY ASSURANCE NOTE**** This method requires that the sample be chilled to 4 degrees centigrade or less at the time of collection and maintained at that temperature until analysis. This sample was received by the DPH Laboratory at a temperature greater than 4 degrees centigrade. EPA 504. 1 COMPOUND RESULT MDL PQL 1 ,2-DIBROMOETHANE 0.08 0.004 0.02 1 ,2-DIBROMO-3-CHLOROPROPANE ND 0.002 0.02 1 ,2,3-TRICHLOROPROPANE 0. 1 0.008 0.04 All values expressd in ug/l (ppb) ND - None Detected ( less then the PQL) MDL - Minimum Detection Limit PQL - Practical Quantitation Limit ( lowest standard) MDL calculated based on a Signal/Noise Ratio of 5: 1 according to CFR Part 136 Appendix B -------- ** END OF REPORT ** FORM NO.OL-6A REV.01-02 a s -Own O-P Sotd% ?A 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CONN. 06074 SOR-Co AREA CODE 860/644-2511 January 6, 2006 CERTIFIED MAIL 70041160 0002 1060 3728 Lucille & Robert Davin 324 Deming Street South Windsor, CT 06074 Dear Lucille & Robert Davin, As you are aware, a confirmatory sample of your well water was collected and delivered to the State Health Department laboratory to be analyzed for several contaminates. Two of these were detected in amounts above the state action levels EDB was present at 0.08 parts per billion. The action level is 0.02 ppb. Also, 1, 2, 3 TCP was detected at 0.1 ppb. The action level is 0.05 ppb. Using this latest and previous data the State Department of Environmental Protection will determine your eligibility to be connected to public water. They will also continue to provide you with bottled water. If you have any questions, please call me at 644-2511, extension 248. Yours truly, Robert Deptula, R.S. Environmental Health Officer RD/cm Cc: MaryAnne Danyluk Ct. DEP, Remediation Section Bureau of Waste Management 79 Elm Street Hartford, CT 06106-5122 STATE OF CONNECTICUT •. . Department of Public Health Division of Laboratory Services R;g , 8020844 06c?74 0 10 Clinton St.,P.O.Box 1689 INFORMATION Hartford,CT 06144 329OUTH WINDSOR CONN.CLINICAL TESTING LICENSE#CL-0197 TELEPHONE:(860)509-8500 AV I N —1 EM I NG ST OUTH WINDSOR CT 06074 ROBERT DEPTUL.A, SANITARIAN 1540 SULLIVAN AVE '• ' . TOWN HALL 12/12/05 12/13/05. 12/21/05 LS©UTH WINDSOR CT 06074 16: 15 15:02 10:01 REPORT FINAL REPORTCOMMENT TEST(S) RESULT(S) AMPLING : POIN*f TAP OLLECTOR: DEPTULA,. BOlB TITLE: RS R I VATE WELL TREATMENT EaE )ATE ANALYZED 12/19/05 ---------------------------------------------------------- EPA METHOD 504. 1 MEASUREMENT OF 1 ,2—DIBROMOETHANE (EDB) , 1 ,2—DIBRdM0- 3--CHLOROPROPANE (DBCP) AND 1 ,2,3 TRICHLOROPROPANE ( 123TCP) IN DRINKING WATER BY MICROEXTRACTION AND GAS CHROMATOGRAPHY WITH _ELECTRON CAPTURE DETECTION. ----------------------------------------------------------- :PA 504. 1 COMPOUND RESULT MDL PQL I ,2-DIBROMOETHANE 0.08 0.004 0.02 1 ,2-DIBROMO-3-CHLOROPROPANE ND 0.002 0.02 1 ,2,3-TRICHLOROPROPANE 0. 1 0.008 0.04 11 values expressd its ug/l (ppb) D - None Detected ( less then the PEAL) DL - Minimum Detection Limit PQL -- Practical Quantitation Limit ( lowest standard) DL Calculated based on a Signal/Noise Ratio of 5. 1 according to CFR Part 136 Appendix B ------ END OF REPORT aE�E FORM NO.OL-6A REV.01-02 1 STATE OF CONNECTICUT • Department of Public Health Division of Laboratory Services R: 800844 L06074—77- 1 10 Clinton St.,P.O.Box 1689 INFORMATION Hartford,CT 06144 32SOUTH WINDSOR CONN.CLINICAL TESTING LICENSE#CL-0197 AV IN TELEPHONE:(860)509-8500 -I JEMiNG ST OUTH WINDSOR CT 06074 ROBERT DEPTULA, SANITARIAN Rj 1540 SULLIVAN AVE - ••• • TOWN HALL 14/12/05 12/13/05 12/21/05 LSOUTH WINDSOR CT 06074 16: 15 15:02 10r01 REPORT FINAL REPCIRT COMMENT TEST(S) RESULT(S) SAMPLING POINT-. TAP COLLECTOR; DEPTULA, BOB TITLE: RS PRIVATE WELL TREATMENT; EdE )ATE ANALYZED 12/19/05 ---------------------------------------------------------- EPA METHOD 504. 1 MEASUREMENT OF 1 ,2-DIBROMOETHANE (EDB) , 1 ,2-DIBRDMO- 3--C:HLOROPROPANE (DBCP) AND 1 ,2r3 TR I CHLOROPROPANE ( 1 3TCP) IN DRINKING WATER BY MICROEXTRACTION AND GAS CHROMATOGRAPHY WITH ELECTRON CAPTURE DETECTION. --H-- ----- :PA 504. 1 COMPOUND RESULT MDL PQL 1 ,2-D I BROMOETHANE 0.08 0.004 0.02 1 ,2 -D I BRQMO-3-CHL OROPROPANE ND 0.002 0.02 1 ,2r3-TRICHLOROPROPANE 0. 1 0.008 0.04 All values expressd in ug/l (PPb) D - None Detected ( less then the POL) DL - Minimum Detection Limit ROL -- Practical Quantitation Limit ( lowest standard) DL calculated based on a Signal/Noise Ratio of 5z1 ccording to CF'R Part 136 Appendix B --'--- ENT} OF REPORT �E�E FORM NO.OL-6A REV.01-02 STATE OF CONNECTICUT Department of Public Health Division of Laboratory Services NR-D 1 18020780 B06074 0 1 10 Clinton St.,P.O.Box 1689 Hartford,CT 06144 CONN.CLINICAL TESTING LICENSE#CL-0197 DAVIN TELEPHONE:(860)509-8500 324 DEMING ST F SOUTH WINDSOR CT 06074 ROBERT DEPTULAY SANITARIAN 1540 SULLIVAN AVE TOWN HALL 11/02/0-- 11/03/0. 11/09/05 L SOUTH WINDSOR CT 06074 14•30 121.03 10•20 FINAL REPORT OMMENT RESULT(S) SAMPLING POINT: TAP COLLECTOR• R. DEPTULA TITLE'• RS PRIVATE WELL TREATMENT• DATE ANALYZED 11/7/05 _____________._-_-_-___-___-_--_-__-_-_____-_-_-_------___- EPA METHOD 504. 1 MEASUREMENT OF lrZ-DIBROMOETHANE (EDB) , 1 ,2-DIBROM0- 3-CHLOROPROPANE (DBCP) AND 1 ,2r3 TRICHLOROPROPANE ( 123TCP) IN DRINKING WATER BY MICROEXTRACTION AND GAS CHROMATOGRAPHY WITH ELECTRON CAPTURE DETECTION. __________________________________________________________ ****QUALITY ASSURANCE NOTE**** This method requires that the sample be chilled to 4 degrees centigrade or less at the time of collection and maintained at that temperature until analysis. This sample was received by the DPH Laboratory at a temperature greater than 4 degrees centigrade. EPA 504. 1 COMPOUND RESULT MDL POL 1 ,2-DIBROMOETHANE 0.08 0.004 0.02 1 ,2-DIBROMO-3-CHLOROPROPANE ND 0.002 0.02 1 ,2r3-TRICHLOROPROPANE 0. 1 0.008 0.04 All values expressd in ug/l (ppb) ND - None Detected ( less then the POL) MDL - Minimum Detection Limit POL - Practical Quantitation Limit ( lowest standard) MDL calculated based on a Signal/Noise Ratio of 5• 1 according to CFR Part 136 Appendix B ------ END OF REPORT FORM NO.OL-6A REV.01-02 STATE OF CONNECTICUT • aelmw Department of Public Health Division of Laboratory Services R:D6 8020844 06074 0 _1 10 Clinton St.,P.O.Box 1689 ,-•;W, .k Hartford,CT 06144 3,2SOUTH WINDSOR CONN.CLINICAL TESTING LICENSE#CL-0197 AV I N TELEPHONE:(860)509-8500 EMING ST . OUTH WINDSOR CT 06074 ROBERT DEPTULA, SANITARIAN -- - -- - 1540 SULLIVAN AVE • • '•: • TOWN HALL 12/12/05 12/13/05 12/21/05 LSOUTH WINDSOR CT 06074 16. 15 15s02 10.101 .•. COMMENT FINAL REPORT TEST(S) RESULT(S) SAMPLING POINT; TAP COLLECTOR; DEPTULA, BOB TITLE: RS PRIVATE WELL TREATMENT: a� ATE ANALYZED 12/19/05 ---------------------------------------------------------- EPA METHOD 504. 1 MEASUREMENT OF 1 ,2-DIBROMOETHANE (EDIT) . 1 ,2--DIBROMO- 3-CHLOROPROPANE (DBCP) AND 1 ,2,3 TRICHLOROPROPANE ( IZ3TCP) IN DRINKING WATER BY MICROEXTRACTION AND GAS CHROMATOGRAPHY WITH ELECTRON CAPTURE DETECTION. --------------------------------------------------._------- PA 504. 1 COMPOUND RESULT MDL PQL 1 ,2-DIBROMOETHANE 0.08 0.004 0.02 1 ,2-DIBROMO-3-CHLOROPROPANE ND 0.002 0.02 1 ,2,3-TRICHLOROPROPANE 0. 1 0.008 0.04 11 values expressd in ug/1 (PPb) D - None Detected ( less then the PQL) DL - Minimum Detection Limit PQL - Practical Quantitation Limit ( lowest standard) DL calculated based on a Signal/Noise Ratio of 5= 1 according to CFR Part 136 Appendix B ------ END OF REPORT FORM NO.OL-6A REV.01-02 40W N Sf4( a R. wG 1540 SULLIVAN AVENUE• SOUTH WINDSOR, CT 06074 SOR"co TELEPHONE (860) 644-2511 August 2, 2005 FINAL CORRESPONDENCE CERTIFIED MAIL Lucille & Robert Davin 324 Deming Street South Windsor, CT 06074 RE: Drinking Water Sampling for Ethylene Dibromide As you may recall, the Town, through a potable water supply grant from the Department of Environmental Protection has made public water available to you. This was done because of ground water contamination in your area due to the cultivation of tobacco and the presence of three contaminates associated with this agricultural activity. Please contact me at 644-2-511 ext. 248-to make arrangements to sample your drinking water supply well and determine if there is an exceedance of the State's drinking water action level for ethylene dibromide; 1,2, 3 trichloropropane or any other chemical constituents identified by the analysis. If there is an exceedance of one of the parameters listed, a confirmatory round of sampling of the supply well will need to be conducted. If the exceedance is confirmed, the proper arrangements will be made to connect your home to public water. The DEP is requiring the Town to offer you this one FINAL CORRESPONDENCE to determine if you wish to have your potable supply well sampled at no cost to yourselves. The Grant will pay for the connection, any necessary plumbing work and the abandonment of your well (which must be done in order to receive grant money). Failure to respond within ten (10)days of receipt of this correspondence will be interpreted as a "no".answer, that you do not wish to be sampled. If you have-any questions, please call me at 644-2511, extension 248. Yours truly, ber�Robert Dept la, R.S. Environmental Health Officer RD/cm Cc: MaryAnne Danyluk CT DEP, Remediation Section, _ Bureau of Waste Management _ 79 Elm Street Hartford, CT 06106-5127 CONSUMER PROTECTION WELL DRILLING. BOARD STATE OF CONNECTICUT PERMIT NUMBER CPR-8 REV.11-e2 DEPARTMENT OF CONSUMER PROTECTION 86433 WELL DRILLING PERMIT _. 165 CAPITOL AVE.;HARTFORD,CONNECTICUT 06106 LOCATION OF WELL(ro") (Strait) (Lot Number) DATE S. WINDSOR 324 DEM IG ST. 3 4/6/84 OWNER OF WELL ® INDIVIDUAL ❑ BUILDER ❑ OTHER(Specify) ROBERT DAVD OWNER'S ADDRESS 29 FARMSTEAD DR. , S. WIiuDSOR, CT. - PROPOSED ® DOMESTIC ❑ ESTABLISHMENT ❑ FARM ❑ WELL PeoBUSINESS — TEST ple being USE OF served. PUBLIC Allt THER WELL ❑ SUPPLY ❑ INDUSTRIAL ❑ CONDITIONING ❑ (Specify) 4 SKETCH OF WELL LOCATION Locale well with respect to at least two roods,showing distance from intersection and front of lot Location of lot to of least two roads Well location on lot and to house (if present) I" yEL,g Indicate North ' d ('aC a Eiui x G Approximate number of feet from well to nearest source of possible contamination: 01 The undersigned is aware that upon-completion of the well, a-"Well Completion Report" containing construction details and information required under Section 25.131 of the 1969 Supplement to•the'General Stotutes must be sent to the owner, the Board-and the Water,Resources Commission on the form provided by the Board.This permit is not valid until all information is filled in and it has been countersigned by the Director of Health or his agent; APPLICANT'S ADDRESS REGISTRATION NO. P.O. BOX 111 S. WILLT14GTO14, CT. 100 BY(Touw Heath Of xer or ent) DATES /, G R ED ❑ . 00 REMARK , t ' 4 el NA L RETURN THIS COPY TO CONNECTICUT WELL DRILLING BOARD WELL COMPLETION .REPORT - STATE OF coNNEcrlcur CPR 9 REV.11_82 DEPARTMENT OF CONSUMER PROTECTION Do NOT fi.171iv,67 WELL DRILLING BOARD FSTE weu No. 165 CAPITOL AVE. HARTFORD,CONNECTICUT 06106 R NO. OWNER NAME ADDRESS _j : ROBMT DAVU 29 FAMM93AD IR- WINDSOR ij� GT-. LOCATION (No. & Street) (Town) OF WELL 32 D EG STt (Lot Number) BUSINESS PROPOSED Fx—1 DOMESTIC ESTABLISHMENT FARM TEST WELL USE OF �WPUBLIC AIR ELL THER SUPPLY INDUSTRIAL CONDITIONING ❑((SpeCy) DRILLING ROTARY AIR MPRESSED CABLE PERCUSSION PERCUSSIONOTHER EQUIPMENT (Specify) CASING LENGTH(feet) DIAMETER (Inches) WEIGHT PER FOOT D IV SHOEw 5 CASING GROUTED? DETAILS €� 6 + WELDED �h C # THREADED YES NO YES NO YIELD HOURS YIELD(G.P.M.) TEST BAILED PUMPED COMPRESSED AIR 0 WATER MEASURE FROM LAND SURFACE—STATIC(Specify feet) DURING YIELD TEST(feet) LEVEL : Depth of Completed Well �y, in feet below Land surface: 230 MAKE LENGTH OPEN TO AQUIFER(feet) SCREEN DETAILS SLOT SIZE DIAMETER(inches) GRAVEL SIZE(inches) FROM feet TO IF GRAVEL Diameter of well including (feet) (feet PACKED: grovel pack (inches): DEPTH FROM LAND SURFACE FEET TO FEET :j — FORMATION DESCRIPTION Sketch exact location of well with distances, to at least two permanent landmarks. 6 Sand. Gravel 30 Glair 30 230 Bedrock �`cc .. .r.a. ,. 42 A If yield was tested at different depths during drilling, list below FEET GALLONS PER MINUTE tt DATE WELL COMPLETED PERMIT NO. REGISTRATION NO. DATE OF REPORT WELL R(Signature) 1-47 DEPT. OF ENVIRONMENTAL PROTECTION -WATER RESOURCES