Loading...
HomeMy WebLinkAboutSeptic New 50 Carriage Drive dawn of OvW4 18inbsor Department of Pollution Control SOUTH WINDSOR, CONNECTICUT" DRAIN LAYER'S PERMIT Application for Permit to Install or Repair Individual Sewage Disposal System Fee Paid $.............2Q..OQ.... By .Qz, .er.....tca....Buildixg...Ilept......-...f,1 /26./..7..4...................... Permit No. .. (....... . .............,....,....... Date ...... .. .- 7....................... Pursuant to written application, permission is hereby granted to the Licensed Drain Layer named herein for repair ......... or construction XXX of an individual sewage disposal system concerning which the following information is submitted: 1. Owner of Property ............ .......................................................... Address of Owner ................................................................................................... 2. Location of Property .......50...4rri><ge...Dry,Ve.....-...90.0...Itill...EstPteR.............................................. Lot No. .........22............. 3. Type of Structure ................NP ixg................................................................................................................................................................................................................. (Dwelling, Commercial Building, Store, etc.) 4. Number of Families or Persons to Occupy Premises ............O.x.e..... .1.. ....f a Aily.................................................................................................. 5. Number of Bedrooms .....Tkree....(3)............ 6. Average Daily Flow ................................................... - Manufacturer and 7. Liquid Capacity of Septic Tank140.0....gxUoxa.............. Material of Septic Tank .......................................................................................... 8. Soil Conditions: Type of Soil ............................................................................................................................................................................................................................. (Sand, Gravel, Clay, etc.) Maximumground water table ..........:.................................................................................................................................................................. 9. If not served by public water supply: Distance from Owner's well ........................................................................ Fromadjacent wells ............................................................................................. 10. Distance to nearest water course, drainage ditch, storm drain or embankment ....................................................................................... 11. Percolation Tests: Time for 1" drop in soil test ........Sevex„.& ,oxe.-textX,.,.(7 1.),,.,xixute.r*..................................................... Classificationof soil ...............................................................................................................................................................:.:................................. 12. Minimum square feet of effective seepage area required 1.6.5 aq....f.t....per...hedroox.......totag,7......of....4.95....aq...1't. 13. Leaching System: Number of trenches ................................................ Length ................................................... Width ................................................... Total ................................................ Other ........................................................................................................................................................................ 14. Plot Plan Attached. ........X.erm............................................ 15. Layout Approved. .................................................................... 16. This permit expires ................................................................................................................... Signature ..........` .............................../ ................................................. (Licensed Drain Layer) Installation Completed, Inspected and Approved in accordance with State Public Health Code and Local Ordinances .................................................................................................................................... 19.................. By ................................................................................................................................................ PollutionProblem abated Date ................................:.....................I....................... ...........................................................................................................................�............... Inspector a E � ' R AGE �Ya 2 ��lT l Elf r- , CAR s ..r .�: J.+ l T.i .12T) r `;, 1>72 A : 130.00 Q•_ 22°55- 06 i NE 01 G g0lt- N 50 N --�8 2 - 2 5. o 9 cv CIAM. A N 30.00 0 3q. gANO N 21.50 ~O h N 3 g R. 60.00 —� 4• �! !000tI GAL- SEP 3 00 5 So 80. P �v � pTe • 3rl T��:�-�.aT �/r7il,'s�i iln 'i aJ(:��J:..t r . T.�T1i l.� } rr FIT", .."T T. �)Al: use 7 + .a �Tilf tT i r�i. STlli•� T+1:� A_1 ����..+ cl rl�.i.N •.F V 1��1`r /a 1 PLOT, PLAN FOR S� CARRIAGE DR. SOUTH WIAIDSOR, CONK. SCALE. / z 40 , DEC, 4, 1973 DAMES E. SHEEH Y L.S. 7034 so a R. ctRB ASK Ex l5 r. S+DES :P x CARR H y I � vo 00 61.247. AfoN nx- - coNc. EXISTING A - 1,30.00 55. 93.D4 EXIST �_e ��� ` -946 e Q4 .0 F. �' 1�I G(jING 5 , FO - FINISH GRADE (ti �U1 D.B. 1250 OAS NK SE pric rA 40 45_70 It _ 36. R COL.ONtAL N LOT 21 BSMt0241. LOT 23 Z48 LO T 22 �. �° x�Sr 2 P T 246 r- 26 t BEM Lar #2 CK MAP i' ` t Exlst ENT IT I- "SA) HILL STATES" MAY 2,1970 REVISED . ` 260 NOV. 1972 REVISED DEC. 3, 1973• SEPTIC SYSTEM SHEET 3 OF 3. 55 LRI EAR FEET OF TILE PER BEDROOM LAID IN 3 Fr. WIDE TRENCHES FILLED WITH WASHED I HEREB2 CERTIFT THIS PLAN SUBST-AN- GRA:VrL OR BRAN STONE FOR A DEPTH OF 18 TI.ALLT CORRECT AND NO ZOKDZ LNGHES, TRENCHES TO By SWAGED 12 F'E ET C.O.0. REGULAT IONS VIOLAT:.D. MIN. PERCOLATION TEST JAMSS E. S�HZy , L.S. 703 DATE OCT. 42 1976 GRMD WATER: NONNIE i fUTE 1 INCH IN 9 MIN. PLOT PLAN FOR OBSERVATION TEST L 1 PA4AN DATE OCT. L, 1976 CARRIAGE DR. SOUTH WINDSOR CORN, uEPTq OF HQ;": 7 FT. SCAL E: I "= 40 ' SEPT. 28 1976 }� Y'ur"l tTALa 0 To 7' BONY GRA'veL DAMES E.- SHEEHY L.S. 7034 �. � � r --27 70 4 v4 2 Z Cf l-rl4 p #So b 2P N 410' Tom/ . N 71 Co 7o&l NOTES SOUTH WINDSOR POLLUTION CONTROL LOCATIO 2Z o OWNER Al,bM019 TYPE OF VORK DATE -�4- PE IT PIPE " /lC INSTALLER INSPECTOR /1 DRAWN BY .a 'OWN OF SOUTH WINDSOR. TOWN HALL_ SOVL'H WINDSOR, CONN. 06074 DEPARTMENT POLLUTION CONTROL Date . . . . The Sanitary Sewer Septic System . . . . . . . . . . at . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . or lot #. . . has been installed and completed in accordance with the Town of South Windsor ordinances and regulations. Accepted and Approved By - -- Date _ ---- --