Loading...
HomeMy WebLinkAboutSeptic Correspondence 300 Buckland Road V E Y I N G ROBERT A.WARD,JR. WAR Licensed Professional Engineer VI C E S Licensed Land Surveyor 22 ELEANOR • VERNON, CONNECTICUT 06066 • (203) 872-6350 MELC-106 25 October 1995 Robert Deptula, R. S., South Windsor Sanitarian TOWN OF SOUTH WINDSOR 1540 Sullivan Avenue South Windsor, Connecticut 06074 RE: PROPERTIES OF MESSIAH EVANGELICAL LUTHERAN CHURCH LOCATED AT 296 AND 300 BUCKLAND ROAD IN SOUTH WINDSOR, CONNECTICUT ---- REMEDIAL SEPTIC SYSTEM IMPROVEMENTS -- FINAL PLANS. Dear Mr. Deptula: We have completed plans for a new pumped septic system at the Messiah Evangelical Lutheran Church and have enclosed two sets for your use. The Church wishes to proceed with construction this year if at all possible. In order to save time, we have sent a copy to Mr. Arthur J. Castellazzo, Sanitary Engineer, On-Site Sewage Disposal Section, Connecticut Department of Public Health and Addition Services, should you wish to solicit his council because of his involvement in this project. We understand that will be no fee required if you only requests verbal comments. Should you require formal written comments, there will be a$100 review fee payable to the State by the Church. Thank you for your assistance and dedication [including the Saturday soils testing] on this project. If you require any additional information, please advise. Very truly yours, G?,",t Q - w" � - Robert A. Ward, Jr., President WARD'S SURVEYING SERVICES enc. MELC-105 letter dated 25 October 1995 MAP 99511851; MAP 99511852; MAP 99511853 p.c. Donald Eichler, Chairman Board of Property Richard L. Johnston, Vice-Chairman Board of Property Pastor Philip J. Henselin aff#fiaszi Of Land' iu%vzyin9 - site # anning - iz#tic iyitzm dzilgn - sagaliv sion UT04 TOWN OF SOUTH WINDSOR HEALTH DEPARTMENT Application for permit to install a new/repair subsurface sewage disposal system. To the Health Department, Town of Sou a1,W'ndsor. Fee Paid G '� )Y 16 Date Permit Number As a subsurface sewage disposal system installer licensed in the State of Connecticut, I D�, f�`'r:L1_ ! y-,--( it "1 t i t. i Ci C:' `q s A .r ,.., � E Name, Address, Telephone Number, License Number hereby apply for a permit to cons_ truct/repair a subsurface sewage disposal system located at and owned by treet, Address, Lot u ber Name ��Address Information to be supplied by Applicant: Type of dwelling If non-residential, estimated daily flow Residential,Commercial,Etc. Number of bedrooms Size of lot Number of fixtures above basement Tubs,Sink$,Toilets,Etc. Number of fixtures in basement, if any , Pumped or gravity flow, Type of water supply If private, type of well Public-Private Information to be supplied by Health Department: Soil type at various levels Percolation rate Square feet of effective leaching area required Size of septic tank Type of system Trenches,Drywelis,Etc. Number of dry wells, trenches, etc. Distance between individual leaching units. Distance from well on same property on adjoining property Curtain drain required Yes,No Height of system above ground water maximum ground water , ledge , impervious soil layer If automatic closing is required,description I i A PLOT PLAN INDICATING LOCATION OF PROPOSED STRUCTURE, WATER SUPPLY, SEPTIC SYSTEM, EM• BANKMENTS, WATERCOURSES, PROPERTY LINES AND ALSO INDICATING EXISTING AND PROPOSED FINISHED GRADES MUST BE SUBMITTED BEFORE THIS PERMIT CAN BE ISSUED. THIS PERMIT IS NOT TRANSFERRABLE FROM PERSON TO PERSON OR FROM PLACE TO PLACE. NO PART OF THE SYSTEM SHALL BE BACKFILLED UNTIL IT HAS BEEN INSPECTED AND APPROVED BY THE SANITARIAN. SPECIFICATION AND REQUIREMENTS AS STATED IN THIS PERMIT MUST BE MET AND ANY CHANGES MUST BE APPROVED BY THE TOWN SANITARIAN BEFORE FINAL APPROVAL WILL BE GIVEN. THIS PERMIT SHALL NOT BE CONSTRUED AS PERMISSION TO CREATE A NUISANCE CONDITION NOR IS THIS SYSTEM GUARANTEED BY THE HEALTH DEPARTMENT. Permit Received by 1% C [; Date Signature of Applicant&License umber F For Office Use Only Permit issued by Date System installed by Final Inspection Approval Date � �Y