HomeMy WebLinkAboutWell Correspondence 136 Beelzebub Road STATE OF CONNECTICUT -
DEPARTMENT OF ENVIRONMENTAL PROTECTION
QUi JgS\NES
TRANBTUC T
August 19, 2009
Liebler Residence
136 Beelzebub Road
South Windsor, CT 06074
Dear Ms. Liebler:
Enclosed is a copy of the laboratory analysis for the unfiltered (raw) water sample collected from
136 Beelzebub Road on 7/9/2009. The water sample was analyzed for the presence of
ethylene dibromide (EDB), 1,2,3-trichloropropane (TCP), and 1,2 dibromo-3-chloropropane
(DBCP) and other pesticides.
Results from the analyses are summarized in Table 1 (attached). Table 1 also includes each
compound's respective action level set by the Connecticut Department of Public Health (DPH).
Please note that only established action levels are included in Table 1. If an action level has not
been listed it means that an action level has not been established for that particular compound
and its detection does not render the water unsafe for drinking or other domestic uses.
Referring to Table 1, the water sample collected from your water supply did not contain
detectable concentrations of pollutants at concentrations at or above their respective action
level. An action level is the concentration at or above which the DPH has determined there
could be a risk to the health of persons consuming the water. Consequently, your water is
considered to be potable.
The other pesticides analyzed were also reported as non detect. If you have any questions or
comments please contact me at (860) 424-3796.
Sincerely,
MaryAnne Danyluk
Environmental Analyst 2
DEP/Bureau of Water Protection and Land Reuse
Remediation Division
Enclosure(s)
(Printed on Recycled Paper)
79 Elm Street • Hartford,CT 06106-5127
www.ci.gov/dep
An Equal Opportunity Employer
TABLE ONE
Raw Water Sample Results
136 Beelzebub Road
South Windsor, Connecticut
COMPOUND ANALYZED CONCENTRATION DETECTED ug/I ACTION LEVEL uz/1
1,2 dibromoethane(EDB) ND 0.05
1,2,3-trichloropropane(TCP) ND 0.05
1,2 dibromo-3-chloropropane(DBCP) ND NAL
Notes: ug/l Microgram per liter
ND Not detected above analytical detection limits
NAL An action level has not been established by the Department of Public Health(DPH)
.....
A
:
STATE OF CONNECTICUT . Wfla
- 18023523AO0142 0NR:136
..................
•
:x.
Department of Public Health Laboratory X,
Clinical Testing License:CL-0197
10 Clinton St. 132SOUTH WINDSOR
P.O.Box 1689 CAROLYN LIE13LER
Hartford,CT 06144
Telephone(860)509-8500 136 BEELZEBUB
SOUTH WINDSOR CT
DEP - REMEDIATION
79 ELM ST. 07/09/09 07/09/09 07/15/09
HARTFORD CT 06106 10:00 12:01 07:28
X
FINAL REPORT
....................
. . ..... ............
X.- ----- ............. .....:..i�
0......................... . X:
. ..ix
............
........................
.....................
X
. ......... ................... X: ...... . ... .. ..... .......
. ..........
.........................
X
........................... . .. .. ..
------------------- xx
SAMPLING POINT: OUTSIDE TAP
COLLECTOR: WINGS TITLE: EA3
PRIVATE WELL TREATMENT:
DATE ANALYZED 7/15/09
----------------------------------------------------------
EPA METHOD 504.1
MEASUREMENT OF 1,2-DIBROMOETHANE (EDB) , 1,2-DIBROMO-
3-CHLOROPROPANE (DBCP) AND 1,2,3 TRICHLOROPROPANE
(123TCP) IN DRINKING WATER BY MICROEXTRACTION AND
GAS CHROMATOGRAPHY WITH ELECTRON CAPTURE DETECTION.
----------------------------------------------------------
EPA 504.1 Final Result: (All values expressed in ug/L (ppb) ]
Compound Result MDL PQL
1,2-Dibromoethane ND 0.0016 0.02
1,2-Dibromo-3-Chloropropane ND 0.0021 0.02
1,2,3-Trichloropropane ND 0.0073 0.04
r
ND = None Detected (Result Less Than The PQL) --4
P" 0
PQL= Practical Quantitation Limit (lowest standard) W
MDL = method Detection Limit r%3
MDL calculated based on a Signal/Noise Ratio of 5:1
according to CFR Part 136 Appendix B
------ END OF REPORT
FORM NO. OL-6A REV.3-00 100
STATE OF CONNECTICUT C
::::><::'.<::::::: ,...:.:::•::::::::::::::::::l ...;;;:.. .. .
ti NR:136-2 18023526 A00142 0 1
Department of Public Health Laboratory ::«:>::::»:<::;:::>:<::z:::>:<:»:<:>::>::>:>.::..............:.::...:....:..:.::..::.:::..:.::<;;:>:<;:.;::;:•:•:•;:•>:•>:•;:;;•;:.;:.;;:.;:.;:.;:.;:.;
Clinical Testing License:CL-0197
10 Clinton St. 132SOUTH WINDSOR
P.O.Box 1689 CAROLYN LIEBLER
Hartford,CT 06144
Telephone(860)509-8500 136 BEELZEBUB
SOUTH WINDSOR CT
DEP - REMEDIATION
79 ELM ST. 07/09/09 07/09/09 08/03/09
HARTFORD CT 06106 10:05 12:02 10:53
FINAL REPORT
Sl3ES.........................................:.::................. .. ...........:....:.....:......::.::::::::::::::::::::::::::..................:....................... ... :..::.::::::::::::::::........:::::::::::
.............................................................................SAMPLING...POINT:....OUTSIDE...TAP.......................................................:.:::::::::::::::::;�::.
COLLECTOR: SCOTT WING TITLE: EA-3 ��j
** PESTICIDES �� � Jae �FGSF
METHOD ------------- O+�
ANALYTICAL METHOD - EPA METHOD 505 v�7/1
ANALYSIS OF ORGANOHALIDE PESTICIDES AND
COMMERCIAL POLYCHLORINATED BIPHENYLS (PCB)
PRODUCTS IN WATER BY MICROEXTRACTION AND
GAS CHROMATOGRAPHY
----------------------------------------------
Date Extracted 07/15/2009
Date Analyzed 07/15/2009
RESULTS Compound Result MDL PQL
ldrin ND 0.007 0.03
lachlor ND 0.042 0.3
trazine ND 0.729 * 1.4
Alpha Chlordane ND 0.006 0.03
Gamma Chlordane ND 0.006 0.03
Chlordane (Technical) ND 0.106 0.3
ieldrin ND 0.004 0.03
ndrin ND 0.005 0.03
Heptachlor ND 0.004 0.03
Heptachlor Epoxide ND 0.004 0.03
exachlorobenzene ND 0.006 0.03
exachlorocyclopentadiene ND 0.004 0.03
indane ND 0.003 0.03
ethoxychlor ND 0.03 0.14
is-Nonachlor ND 0.006 0.03
Trans-Nonachlor ND 0.007 0.03
Simazine ND 0.481 ** 1.4
oxaphene ND 0.224 3.0
roclor 1016 ND N/A N/A
roclor 1221 ND N/A N/A
roclor 1232 ND N/A N/A
roclor 1242 ND N/A N/A
roclor 1248 ND N/A N/A
*** CONTINUED ***
FORM NO. OL-6A REV.3-00 100
STATE OF CONNECTICUT
NR:136-2 18023526 IA00142 0 2
.............................
Department of Public Health Laboratory
Clinical Testing License:CL-0197
10 Clinton St. 132SOUTH WINDSOR
P.O.Box 1689 CAROLYN LIEBLER
Hartford,CT 06144
Telephone(860)509-8500 136 BEELZEBUB
SOUTH WINDSOR CT
DEP REMEDIATION ---------------
79 ELM ST. 07/09/09 07/09/09 08/03/09
HARTFORD CT 06106 10:05 12 :02 10:53
FINAL REPORT
..... .... .......
. . ........... ......
. . . . ........... .........
.... ... .
.... . ....
.... . ....
............
Aroclor 1254 ND N/A N/A
Aroclor 1260 ND N/A N/A
utachlor ND N/A N/A
Propachlor ND 0.054 0.3
Metolachlor ND N/A N/A
Metribuzin ND N/A N/A
p,p' -DDE ND N/A N/A
p,pl -DDD ND N/A N/A
p,pl -DDT ND N/A N/A
ND = None Detected (Result Less Than The PQL)
PQL =Practical Quantitation Limit
MDL =Method Detection Limit
All values expressed in ug/L (ppb)
Values Calculated based on a Signal/Noise Ratio of 5:1
according to CFR Part 136 Appendix B
The 2.2 multiple of the MDL for this compound exceeds
the federal upper control limit (UCL) of 0.22.
The 2.2 multiple of the MDL for this compound exceeds
the federal upper control limit (UCL) of 0.154.
Note: The recovery of Simazine was elevated in the
calibration check standards. Any detects or non-detects
for this analyte could be considered biased high.
------ END OF REPORT
FORM NO. OL-6A REV.3-00 100
col)---
,,0
-own O-P SllatdA 2li
G fi U
s 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CT 06074
SOR-co TELEPHONE (860) 644-2511
Dear Homeowner:
The Town of South Windsor Health Department's goal is to keep you informed about the
status of water quality throughout the town whether you are served by and individual well
or by a public water source.
In an attempt to better serve you, we have reviewed our files to ensure we have the
most recent and accurate information possible. Our review has revealed that we do not
have any information regarding how your residence receives its water.
We are hopeful that you will take a moment to help us keep our records current. Please
indicate the type of water service by circling the appropriate entry below and return this
letter no later than in February 27, 2009, in the self addressed stamped envelope
provided.
If you receive your water from a private well, please let us know the location as it relates
to your home by providing two measurements from the foundation to the well in the
space provided and let us know if the well is used for domestic, lawn and garden, or
agricultural use. See example below.
Thank you in advance for your cooperation.
Any questions can be addressed to the South Windsor Environmental Health Officer,
Robert De Vito at 860-644-2511, extension 248.
Water service: 4 3 6 "C 1:(2 U
Circle the appropriate service: RECE,vED
WELL MDC =A��
.WELL USE: DOMESTIAGRICULTURAL ��-� 0
S00-f RING OEPT.
Well Location : 2-C. --ENGW
e 1
BACK DRAWING:
40 FT
A :�FRONT B
30F 14FT y�
WELL
STREET
Pcig-