HomeMy WebLinkAboutWell Correspondence 80 Beelzebub Road STATE OF CONNECTICUT
DEPARTMENT OF ENVIRONMENTAL PROTECTION
ooi r yes<NEz i _...• -
RAN$
TU<IT
June 4, 2009
Trahen Residence
80 Beelzebub Road
South Windsor, CT 06074
Dear Mr. and Mrs. Trahen:
Enclosed is a copy of the laboratory analysis for the unfiltered (raw) water sample collected from
80 Beelzebub Road on 3/6/2009 and 5/8/2009. The water sample was analyzed for the
presence of ethylene dibromide (EDB), 1,2,3-trichloropropane (TCP), and 1,2 dibromo-3-
chloropropane (DBCP) and other pesticides.
Results from the analyses are summarized in Table 1 (attached). Table 1 also includes each
compound's respective action level set by the Connecticut Department of Public Health (DPH).
Please note that only established action levels are included in Table 1. If an action level has not
been listed it means that an action level has not been established for that particular compound
and its detection does not render the water unsafe for drinking or other domestic uses.
Referring to Table 1, the water sample collected from your water supply did not contain
detectable concentrations of pollutants at concentrations at or above their respective action
level. An action level is the concentration at or above which the DPH has determined there
could be a risk to the health of persons consuming the water. Consequently, your water is
considered to be potable.
All other pesticides analyzed were also non detect.
Sincerely,
MaryAnne Danyluk
Environmental Analyst 2
DEP/Bureau of Water Protection and Land Reuse
Remediation Division
Enclosure(s)
C: Bob DeVito,Town of South Windsor, 1540 Sullivan Avenue, South Windsor, CT 06074
(Printed on Recycled Paper)
79 Elm Street • Hartford,CT 06106-5127
www.ct.gov/dep
An Equal Opportunity Employer
TABLE ONE
Raw Water Sample Results
80 Beelzebub Road
South Windsor, Connecticut
COMPOUND ANALYZED CONCENTRATION DETECTED ug/1 ACTION LEVEL u2/1
1,2 dibromoethane(EDB) ND 0.05
1,2,3-trichloropropane(TCP) ND 0.05
1,2 dibromo-3-chloropropane(DBCP) ND NAL
Notes: ug/1 Microgram per liter
ND Not detected above analytical detection limits
NAL An action level has not been established by the Department of Public Health(DPH)
........ ..
STATE OF CONNECTICUT ..
NR:80 18023206 IA00142 1 0
...............------- ... .......... ......
. ........
. .. .......
Department of Public Health Laboratory
RMOR9
MRSClinical Testing License:CL-0 197
10 Clinton St. 1325. WINDSOR
P.O.Box 1689 J&L TRAHAN
Hartford,CT 06144
Telephone(860)509-8500 80BEEZELBUB RD
S. WINDSOR CT
DEP - REMEDIATION WPM wm� M"M
79 ELM ST. 03/06/09 03/06/09 03/18/09
HARTFORD CT 06106 11:45 15:14 08:28
FINAL REPORT NOW
.............. . .........................
Emma=
mesm
SAMPLING POINT: OUTSIDE
COLLECTOR: BRIGHTWELL TITLE: INSPECTOR AIDE
PRIVATE WELL
DATE ANALYZED 3/17/09
----------------------------------------------------------
EPA METHOD 504.1
MEASUREMENT OF 1,2-DIBROMOETHANE (EDB) , 1,2-DIBROMO-
3-CHLOROPROPANE (DBCP) AND 1,2,3 TRICHLOROPROPANE
(123TCP) IN DRINKING WATER BY MICROEXTRACTION AND
GAS CHROMATOGRAPHY WITH ELECTRON CAPTURE DETECTION.
----------------------------------------------------------
EPA 504.1 COMPOUND RESULT MDL PQL
1,2-DIBROMOETHANE ND 0.0017 0.02
1,2-DIBROMO-3-CHLOROPROPANE ND 0.0016 0.02
1,2,3-TRICHLOROPROPANE ND 0.0031 0.04
All values expressd in ug/l (ppb)
ND - None Detected (less then the PQL)
MDL - Minimum Detection Limit
PQL - Practical Quantitation Limit (lowest standard)
MDL calculated based on a Signal/Noise Ratio of 5:1
according to CFR Part 136 Appendix B
M ;a
X A
M X:
a J, 9
M
> n
0 00 E4
z END..OF -R-E PORT- -*-*----- - --
FORM NO. OL-6A REV.3-00 100
STATE OF CONNECTICUT 18023385
. .......
Department of Public Health Laboratory
Clinical Testing License: CL-0 197
10 Clinton St. 132SOUTH WINDSOR
P.O.Box 1689 JOSEPH+LORI TRAHEN
Hartford,CT 06144
Telephone(860)509-8500 80 BEELZEBUB
SOUTH WINDSOR CT
DEP - REMEDIATION >MOM
79 ELM ST. 05/08/09 05/09/09 05/15/09
HARTFORD CT 06106 12:10 08:59 11:38
FINAL REPORT
.............. Mm.,
SAMPLING POINT: OUTSIDE
COLLECTOR: BRIGHTWELL TITLE: INSPECTOR AIDE
PESTICIDES
METHOD
----------------------------------------------
ANALYTICAL METHOD - EPA METHOD 505
ANALYSIS OF ORGANOHALIDE PESTICIDES AND
COMMERCIAL POLYCHLORINATED BIPHENYLS (PCB)
PRODUCTS IN WATER BY MICROEXTRACTION AND
GAS CHROMATOGRAPHY
--------------------- ------------------------
Date Extracted 05/12/2009
Date Analyzed 05/12/2009
RESULTS COMPOUND RESULT MDL(ug/1) PQL(ug/1)
ALDRIN ND 0.007 0.03
ALACHLOR ND 0 .042 0.3
RAZINE ND 0.729 1.4
ALPHA CHLORDANE ND 0.006 0 .03
GAMMA CHLORDANE ND 0 .006 0.03
CHLORDANE (TECHNICAL) ND 0.106 0.3
PIELDRIN ND 0.004 0.03
ENDRIN ND 0 .005 0 .03
HEPTACHLOR ND 0.004 0.03
HEPTACHLOR EPDXIDE ND 0.004 0 .03
HEXACHLOROBENZENE ND 0.006 0.03
HEXACHLOROCYCLOPENTADIENE ND 0.004 0.03
Uj LINDANE ND 0.003 0.03
aZ METHOXYCHLOR ND 0.03 0.14
Uj
w 0 CIS-NONACHLOR ND 0.006 0.03
,mayTRANS-NONACHLOR ND 0.007 0.03
>
0 SIMAZINE ND 0.481 1.4
C%Q
TOXAPHENE ND 0.224 3 .0
Z
0 AROCLOR 1016 ND N/A N/A
c~jAROCLOR 1221 ND N/A N/A
Lu
CD AROCLOR 1232 ND N/A N/A
w LU
a_ :2 AROCLOR 1242 ND N/A N/A
cc uj AROCLOR 1248 ND N/A N/A
CONTINUED
FORM NO. OL-6A REV.3-00 100
STATE OF CONNECTICUT ...... Jtq
... . ......
NR:80 18023385 A00142 0 1
Department of Public Health Laboratory
Clinical Testing License:CL-0197
10 Clinton St. 132SOUTH WINDSOR
P.O.Box 1689 JOSEPH+LORI TRAHEN
Hartford,CT 06144
Telephone(860)509-8500 80 BEELZEBUB
SOUTH WINDSOR CT
DEP - REMEDIATION
...........
79 ELM ST. 05/08/09 05/09/09 05/15/09
HARTFORD CT 06106 12:10 08:59 11:38
FINAL REPORT
.....................
..... .....................
. ..... .... ..................
K..:.................
.................... .................. . . .......
.................................. ....
AROCLOR 1254 ND N/A N/A
AROCLOR 1260 ND N/A N/A
UTACHLOR ND N/A N/A
PROPACHLOR ND 0.054 0.3
METOLACHLOR ND N/A N/A
METRIBUZIN ND N/A N/A
p,p' -DDE ND N/A N/A
p,pl -DDD ND N/A N/A
p,pl -DDT ND N/A N/A
ND NONE DETECTED (RESULT LESS THAN THE PQL)
PQL = PRACTICAL QUANTITATION LIMIT
Values Calculated based on a Signal/Noise Ratio of 5:1
ccording to CFR Part 136 Appendix B
The 2 .2 multiple of the MDL for this compound exceeds
the federal upper control limit (UCL) of 0 .22
The 2.2 multiple of the MDL for this compound exceeds
the federal upper control limit (UCL) of 0 .154
END -OF--REPORT-
FORM NO. OL-6A REV.3-00 100
4
4 jJ
e �
y r.
0-/C S-0� ?d&U&Ot
1540 SULLIVAN AVENUE• SOUTH WINDSOR, CT 06074
YQSOR.CO TELEPHONE (860) 644-2511
January 13, 2006
CERTIFIED MAIL 7004 2510 0003 9803 4213
(Min
o an
80 Beelzebub
indsor, CT 06074
Dear Mr. & Mrs. Trahan,
As you are aware,.a sample of your well water was collected &delivered to the State
Health Department laboratory for analysis for certain compounds.
As is evident from the enclosed laboratory report. None were detected.
Using this and previous data, the DEP will make a final determination as to whether or
not you are eligible to be connected to the public water if you want to be connected.
If you have any questions please contact me at the South Windsor Town Hall at 644-
2511 ext. 248.
Yours truly,
Aid "
Robert Deptula, R.S.
Environmental Health Officer
RD/cm
Cc: MaryAnne Danyluk
CT DEP, Remediation Section,
Bureau of Waste Management
79 Elm Street
Hartford, CT 06106-5122
_ M
STATE OF CONNECTICUT •
Department of Public Health 7-T 7BG t?85� 106074 01
Division of Laboratory Services
10 Clinton St.,P.O.Box 1689 INFORMATION
Hartford,CT 06144
CONN.CLINICAL TESTING LICENSE#CL-0197 rRAHAN
TELEPHONE:(860)509-8500 30 BEELZEBUB
F 3OUTH WINDSOR CT 06074
ROBERT DEPTULA: SANITARIAN
1540 SULLIVAN AVE • • REPORTED
TOWN HALL 12/12/O5 12/13/05 12/27/05
SOUTH WINDSOR CT 06074 16:30 15:C?9 14: 13
PORT COMMENT
TEST(S) RESULT(S)
COLLECTOR: DERTUAL: BOB TITLE: RS
PRIVATE WELL
* PESTICIDES
METHOD -----------------------------------------------
ANALYTICAL METHOD — EPA METHOD 505
ANALYSIS OF ORGANOHALIDE PESTICIDES AND
COMMERCIAL POLYCHLORINATED BIPHENYLS (PCB)
PRODUCTS IN WATER BY MICROEXTRACTION AND
GAS CHROMATOGRAPHY
-----------------------------------------------
ate Extracted 12/14/05
ate Analyzed 12/14/05
ESULTS C MPOUND RESULT MDL(ug/1 ) POL(ug/1 )
A DRIN ND 0.006 0.0286
A ACHLOR ND 0.080 0.2886
A RAZINE ND 1 .438 2.0000
ALPHA CHLORDANE ND 0.008 0.0286
GAMMA CHLORDANE ND 0.006 0.0286
C LORDANE (TECHNICAL) ND 0.247 0.:2869
DIELDRIN ND 0.008 0.0286
E DRIN ND 0.037 0.0Z86
HEPTACHLOR ND 0.005 0.0286
HEPTACHLOR EPDXIDE ND 0.006 0.0286
H XACHLOROBENZENE ND 0.004 0.0:286
H XACHLOROCYCLOPENTADIENE ND 0.007 0.0286
L NDANE ND 0.005 0.0286
M THOXYCHLOR ND 0.025 0. 1429
C S—NONACHLOR ND 0.007 0.0286
T ANS—NONACHLOR ND 0.00.6 0.0286
S MAZINE ND 2.262 2.0000
T ?;APHENE ND 0.859 1 .4329
A OCLOR 1016 ND N/A N/A
A OCLOR 1221 ND N/A N/A
A OCLOR 1232 ND N/A N/A
A OCLOR 1242 ND N/A N/A
CONTINUED
FORM NO.OL-6A REV.01-02
r
• STATE OF CONNECTICUT •
Department of Public Health 7R. 3 6020851) 06074 0 2
Division of Laboratory Services
10 Clinton St.,P.O.Box 1689 INFORMATION
Hartford,CT 06144
CONN.CLINICAL TESTING LICENSE#CL-0197 rRAHAN
TELEPHONE:(860)509-8500 30 BEELLEBUB
F 3OUTH WINDSOR CT 06074
ROBERT DEPTULAY SANITARIAN
1540 SULLIVAN AVE • ••-
TOWN HALL 12/12/05 12/13/05 12/27/05
LSOUTH WINDSOR CT 06074 16.30 15,'09 14: 13
REPORT IIZIMIMI��RES�ULT(S)
COMMENT
A OCLOR 1254 ND 0.486 0.2871
A OCLOR 1260 ND 0.582 0.2869
B TACHLOR ND N/A ' N/A
P OPACHLOR ND 0. 104 0. 1431
M TOLACHLOR ND N/A N/A
M TRIBUZIN ND N/A N/A
p,p'-DDE ND N/A N/A
p:p'-DDD ND N/A N/A
pyp'-DDT ND N/A N/A
NE NONE DETECTED (RESULT LESS THAN THE POL)
P •L = PRACTICAL QUANTITATION LIMIT
Values Calculated based on a Signal/Noise Ratio of 5: 1
according to CFR Part 136 Appendix B
The 2.2 multiple of the MDL for this compound exceeds
the federal upper control limit (UCL) of 0.22
The 2.2 multiple of the MDL for this compound exceeds
the federal upper control limit (UCL) of 0. 154
I�
•----- END OF REPORT
FORM NO.OL-6A REV.01-02