HomeMy WebLinkAboutWell Correspondence 49 Beelzebub Road STATE OF CONNECTICUT DEPARTMENT OF ENVIRONMENTAL PROTECTION DUi y SSNEt .• TRANS 1 To[IT June 4, 2009 Cecchini Residence 49 Beelzebub Road South Windsor, CT 06074 Dear Mr. and Mrs. Cecchini: Enclosed is a copy of the laboratory analysis for the unfiltered (raw) water sample collected from 49 Beelzebub Road on 5/8/2009. The water sample was analyzed for the presence of ethylene dibromide (EDB), 1,213-trichloropropane (TCP), and 1,2 dibromo-3-chloropropane (DBCP) and other pesticides. Results from the analyses are summarized in Table 1 (attached). Table 1 also includes each compound's respective action level set by the Connecticut Department of Public Health (DPH). Please note that only established action levels are included in Table 1. If an action level has not been listed it means that an action level has not been established for that particular compound and its detection does not render the water unsafe for drinking or other domestic uses. Referring to Table 1, the water sample collected from your water supply did not contain detectable concentrations of pollutants at concentrations at or above their respective action level. An action level is the concentration at or above which the DPH has determined there could be a risk to the health of persons consuming the water. Consequently, your water is considered to be potable. All other pesticides analyzed were also non detect. If you have any questions do not hesitate to contact me at (860) 424-3796. Sincerely, A ..�V�✓ J ( ��C/�V✓w, MaryAnne Danyluk Environmental Analyst 2 DEP/Bureau of Water Protection and Land Reuse Remediation Division Enclosure(s) Bob Devito, Town of South Windsor, 1540 Sullivan Avenue, South Windsor, CT 06074 (Printed on Recycled Paper) 79 Elm Street • Hartford,CT 06106-5127 www.ct.gov/dep An Equal Opportunity Employer TABLE ONE Raw Water Sample Results 49 Beelzebub Road South Windsor, Connecticut COMPOUND ANALYZED CONCENTRATION DETECTED uj!/I ACTION LEVEL ug/1 1,2 dibromoethane(EDB) ND 0.05 1,2,3-trichloropropane(TCP) ND 0.05 1,2 dibromo-3-chloropropane(DBCP) ND NAL Notes: ug/I Microgram per liter ND Not detected above analytical detection limits NAL An action level has not been established by the Department of Public Health(DPH) STATE OF CONNECTIC-UT NR:49 18023205 IA00142 1 0 1 Department of Public Health Laboratory Clinical Testing License: CL-0197 10 Clinton St. 132S. WINDSOR P.O.Box 1689 S&J CECCHINI Hartford,CT 06144 Telephone(860)509-8500 49 BEEZELBUB R _qn CT DEP - REMEDIATION 79 ELM ST. 03/06/09 03/06/09 03/18/09 HARTFORD CT 06106 11:30 15:14 08:28 FINAL REPORT ............. ......... ..................................... ...... ... US .......... ........ ............ .... .... ............. SAMPLING POINT: KITCHEN COLLECTOR: BRIGHTWELL TITLE: INSPECTOR AIDE PRIVATE WELL DATE ANALYZED 3/17/09 ---------------------------------------------------------- EPA METHOD 504.1 MEASUREMENT OF 1,2-DIBROMOETHANE (EDB) , 1,2-DIBROMO- 3-CHLOROPROPANE (DBCP) AND 1,2,3 TRICHLOROPROPANE (123TCP) IN DRINKING WATER BY MICROEXTRACTION AND GAS CHROMATOGRAPHY WITH ELECTRON CAPTURE DETECTION. ---------------------------------------------------------- EPA 504.1 COMPOUND RESULT MDL PQL 1,2-DIBROMOETHANE ND 0.0017 0.02 1,2-DIBROMO-3-CHLOROPROPANE ND 0.0016 0.02 1,2,3-TRICHLOROPROPANE ND 0.0031 0 .04 All values expressd in ug/l (ppb) ND None Detected (less then the PQL) MDL Minimum Detection Limit PQL Practical Quantitation Limit (lowest standard) MDL calculated based on a Signal/Noise Ratio of 5:1 according to CFR Part 136 Appendix B M M M > C3 1 :j 0 2M cc Q in I -- -- - ------- **--END OF REPORT FORM NO. OL-6A REV.3-00 100 STATE OF CONNECTICUT NR.49 18023384 A00142 ANVO Department of Public Health Laboratory A60�& Clinical Testing License: CL-0197 sm 10 Clinton St. 132SOUTH WINDSOR P.O.Box 1689 S + J CECCHINI Hartford,CT 06144 Telephone(860)509-8,500 49 BEELZEBUB SOUTH WINDSOR CT DEP - REMEDIATION .... 79 ELM ST. 05/08/09 05/09/09 05/15/09 HARTFORD CT 06106 12:00 08:59 10:23 FINAL REPORT . ..... ........ . ......................... SAMPLING POINT: KITCHEN COLLECTOR: BRIGHTWELL TITLE: INSPECTOR AIDE PESTICIDES METHOD ---------------------------------------------- ANALYTICAL METHOD - EPA METHOD 505 ANALYSIS OF ORGANOHALIDE PESTICIDES AND COMMERCIAL POLYCHLORINATED BIPHENYLS (PCB) PRODUCTS IN WATER BY MICROEXTRACTION AND GAS CHROMATOGRAPHY ---------------------------------------------- Date Extracted 05/12/2009 Date Analyzed 05/12/2009 RESULTS COMPOUND RESULT MDL(ug/1) PQL(ug/1) LDRIN ND 0.007 0.03 ALACHLOR ND 0.042 0.3 ATRAZINE ND 0.729 1.4 ALPHA CHLORDANE ND 0.006 0.03 GAMMA CHLORDANE ND 0.006 0.03 CHLORDANE (TECHNICAL) ND 0.106 0.3 DIELDRIN ND 0.004 0.03 ENDRIN ND 0.005 0.03 HEPTACHLOR ND 0 .004 0 .03 HEPTACHLOR EPDXIDE ND 0.004 0.03 HEXACHLOROBENZENE ND 0.006 0.03 LU HEXACHLOROCYCLOPENTADIENE ND 0.004 0.03 w LINDANE ND 0.003 0.03 METHOXYCHLOR ND 0.03 0.14 C= CIS-NONACHLOR ND 0.006 0.03 > C= TRANS-NONACHLOR ND 0.007 0.03 SIMAZINE ND 0.481 1.4 0 TOXAPHENE ND 0.224 3.0 AROCLOR 1016 ND N/A N/A OCLOR 1221 ND N/A N/A AROCLOR 1232 ND N/A N/A Uj AROCLOR 1242 ND N/A N/A AROCLOR 1248 ND N/A N/A CONTINUED FORM NO. OL-6A REV.3-00 100 STATE OF CONNECTICUT ::>:>::»:::>.::.:::::.:::..::::::.::.:•.;,::::;;a ..:.:ova:r -:.;::.; cur: .:.;: :.:::< :.:.:;.:.:.:::.; NR:49 18023384 A00142 0 2 Department of Public Health Laborato P ry :::::::::::.:.:..:...:...::.::....:....:._:::._::::::::::.:::::::::::::::::::::. <:zt:.. tail;• ''.'�:; .• Clinical Testing Lice - C1 sttn License:CL 0197 g 10 Clinton St. 132SOUTH WINDSOR P.O.Box 1689 S + J CECCHINI Hartford,CT 06144 Telephone(860)509-8500 49 BEELZEBUB SOUTH WINDSOR CT DEP - REMEDIATION 79 ELM ST. 05/08/09 05/09/09 05/15/09 HARTFORD CT 06106 12:00 08:59 10:23 FINAL REPORT :......::.::.::::::::: : .....................1....................::................ OCLOR 1254 ND N/A N/A OCLOR 1260 ND N/A N/A UTACHLOR ND N/A N/A PROPACHLOR ND 0.054 0.3 ETOLACHLOR ND N/A N/A ETRIBUZIN ND N/A N/A ,p' -DDE ND N/A N/A ,p' -DDD ND N/A N/A ,p' -DDT ND N/A N/A ND NONE DETECTED (RESULT LESS THAN THE PQL) PQL = PRACTICAL QUANTITATION LIMIT Values Calculated based on a Signal/Noise Ratio of 5:1 ccording to CFR Part 136 Appendix B * The 2.2 multiple of the MDL for this compound exceeds the federal upper control limit (UCL) of 0 .22 ** The 2 .2 multiple of the MDL for this compound exceeds the federal upper control limit (UCL) of 0.154 >.� ** -END OF REPORT FORM NO. OL-6A REV.3-00 100