HomeMy WebLinkAbout11 Aroda Drive (5) PE MIT #
Application For 3044 2 2
DEPARTMENT DECISIONcd Heating Permit
3 APPLICATION IS HEREBY: DEPARTMENT OF LICENSES AND INSPECTIONS
N +' APPROVED ❑ DISAPPROVED
TOWN OF SOUTH WINDSOR
o
cd 6-22-64 .:�
00 a) DATE CW INSPECTOR- APPLICATIONS MUST BE PRINTED OR TYPED. BEGIN WITH NUMBER ONE BELOW
O
c 1. LOCATION OF JOB 7 11,
0
I~
4,
cd >.., NO. STREET
-4� 0
cd
a) m
a) LOT NO. FLOOR APT. NO.
O
N
a)
a> 0 2. OWNER �� 4071 S
O %
0 0 s. ADDRESSbo
4 G✓ `��� /�s�
r.
�N
a)
a:/ //1'C Slj 4.PHONE
m D _
•�dr//�lTiri/ /U2 � S. APPLICANTS,
vi ca
O w e. ADDRESS
rO
1-4u`di x" �'J�/1 7.PHONE 6v4I/ 3/—
0 '0
S. LICENSE N0.
,� y0
w
O 9. EXPIRATION DATE OF LICENSE
v �
.a 10. ESTIMATED COST s
-4J o � �
IS THIS A CONTRACT COST? L<J'YES ❑ NO
� y 12. FEE ENCLOSED S Permit #4797
a> 0
U
aa) 13. TYP OF ILDING:
rA RESIDENTIAL ❑ COMMERCIAL
" .� 14. TYPE OF JOB: ❑ INDUSTRIAL
cd 3
O�IIGI ❑ ALTERATION
STALLALLATION ADDITION
REPAIR
1
1 APPLICATION FOR HEATING PERMIT (c ntinued from Reverse Side)
11. LOCATION OF JOB Z TO- _Nt �/3 - zy"/ ,�
12. TYPE OF INSTALLATION: NO ❑ OIL BURNER STR T HEATING SYSTEM ❑ VENTILATIONFLOOR ❑ SPRINKLER
1 GAS BURNER ❑ STACK ❑ INCINERATOR ❑ MISCELLANEOUS
IDENTIFY
SIZE LOCATION SIZE SIZE
13. OF TANK OF TANK OF FILL OF VENT
14. B.T.U. EQUIP. AT REGISTER FURNACE MAKE AND NO. AT BONNET FIR NG RATE
BOILER OR FURNACE MAKE AND NO. S B.T.U. OR SQ. FT. NET a�B.T.U. OR SQ. FT. GROSSRING RATE %�
FLOORS TO BE HEATED NEW OR l tTY BUILDING &f uJ INSULATED - YES OR Ner- 4
TYPE OF WALL LJBod 4rd `
mr�INSULATION /W_& 1 ROOF OR CEILING J�'S INSULATION
l
AVG. SYSTEM WATER TEMP. 20 B.T.U./SQ. FT./HR. EMISSION
INDOOR-OUTDOOR TEMPERATURE DIFFERENCE a- SU °FAHRENHEIT
MAKE OF RADIATION: BASEBOARD, COPPER CONVECTORS,�ORR.C.I. RADIATION. OUTPUT PER SECTION OR LINEAL OF RADIATION. SQ.
FT. OR B.T.U.— fp `g. �' O C) 1 u .- `(- /
DESCRIPTION OF WORK 157
15. TO BE DONE:
16. HEAT LOSS SCHEDULE. (TO BE INCLUDED FOR ALL JOBS).
Ow E.T.U• e.T.U. DISTRIBUTION INSTALLED
¢C
ROOM SIZE ,.,wINDND DOOsRS AREA - SQUARE FEET VOLUME t)<TOTAL TOTAL
TOTAL in
ROOM NO. GROSS GLASS NET WALL CEILING FLOOR CU.FT. AT A•F CORRECTED J j LL 4 RAD. REGISTER
L Tw -
AND S: TEMP. n TO?' F f TYPE AND SIZE OR LEADER
SIZE < WALL f'GtG (INFILT.) DIFF. °F O m N SQ. FT. FREE AREA
h1 3 alc) G. // p�911)J
,0c> 0 0 tiD 1 �7G�v (r a
�y yv „
� 3 L /r4 ,o� v �
r
' (ort> erv-J b-m oc� /QZ� is �' ' f
rr�• �' l o -D v s yo '
4 erD % C� •2�
TOTALS
A. HEAT LOSS FROM BUILDING �� S � B.T.U./HR.
B. DOMESTIC HOT WATER DEMAND /Z� B.T.U./HR.
C. PIPING, OTHER THAN NORMAL B.T.U./HR.
ALLOWANCE FOR HEAT VALVE OF FUEL (A B C) FACTOR
17. ELECTRICAL WORK BY:
NAME ADDRESS
SUBCONTRACTORS AND
16. THEIR TRADES
ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE (OWNER) OR (AGENT) OF THIS PROPERTY AND WILL
BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE.
APPLICATION TO BE COMPLETELY FILLED IN.
DATE y� SIGNATURE OF APPLICANT