Loading...
HomeMy WebLinkAbout18 Andmar Lane (6) Orr rrr PERMIT # Application For 5060 4859 DEPARTMENT DECISION Heating Permit 0 3 APPLICATION IS HEREBY: O DEPARTMENT OF LICENSES AND INSPECTIONS N " XK.XPPROVED DISAPPROVED TOWN OF SOUTH WINDSOR Cd o a d D TE C IN APPLICATIONS MUST BE PRINTED OR TYPED. BEGIN WITH NUMBER ONE BELOW O C1. LOCATION OF JOB �+ O ad fr NO. STREET Cd Cd W 13Z 4) y LOT NO. FLOOR AR. NO. � O N O 79 2. OWNER O 00 O S. ADDRESS 3 y y 4.PHONE m D cc Cn S. APPLICAN B. ADDRES Cc c 7.PHONE 16 B. LICENSE NO. �d a,36 / C� C w B. EXPIRATION DATE OF LICENSE �;! v / A 10. ESTIMATED COST S 11. IS THIS A CONTRACT COST? ❑ YESrz b0 12. FEE ENCLOSED iPermit 10432 cOi aXi 12. TYPE OF BUILDING-. d! U-RE EEMT1AL ❑ COMMERCIAL +' .� 14. TYPE F JOB: � ❑ INDUSTRIAL O STALLASTION ElADDIT OTION REPAIR Aim �A I® APPLICATION FOR HEATING PERMIT (C ntlnued from Revene 8141e) 11. LOCATION OF JOB `j It NO. STR iLOOR A►7.NO. 12. TYPE OF INSTALLATION: OIL BURNER ❑ EL CTRIC ❑ VENTILATION ❑ SPRINKLER ❑ GAS BURNER Cl STACK ❑ INCINERATOR ❑ MISCELLANEOUS IDENTIFY SIZE LOCATION f SIZE y SIZE 13. OF TANK /OD O OF TANK OF FILL x OF VENT d- 14. B.T.U. EQUIP. AT REGISTER FURNACE KE AND NO. AT BONNET FIRING RATE BOILER OR FURNACE MAKE AND NQ LWORT.U. OR SQ. FT. NETI-2& —B.T.U. OR SQ. FT. GROSS FIRING RATE FLOORS TO BE HEATED NEW OR OLDBUILDING INSULATED — YES OR NO TYPE OF WALL -3 INSULATION t//o ROOF OR CEILING INSULATION AVG. SYSTEM WATER TEMP. ///'J - --v,g B.T.U./SQ. FT./HR. EMISSION INDOOR-OUTDOOR TEMPERATURE DIFFERENCE 6 — z U °FAHRENHEIT MAKE OF RADIATI : BASEBOARD. COPPER CONVECTORS, OR C.I. ADIATION. OUTPUT PER SECTION OR LINEAL OF RADIATION. SO. FT. OR B.T.U. �6) DESCRIPTION OF W6RK 15. TO BE DONE: Is. HEAT LOSS SCHEDULE. (TO BE INCLUDED FOR ALL JOBS): N00Y sl is AND D0011■ _ �Olt!•af TOTAL TOTAL N, a 11DOY NO p/1�9LAX& N[T MALL CV10W IILOa Cu.�. A\ ?0-I J i C - -- --------- R - 7` l 1 11 AND Tl�N. TO rr�1; TY�[AND NZ[ [~� �j •li[ WALL. ,A * r-- - 4INFILT.1 a^, •` O [Q [ _ _ nr is 7 _ 3 Bali t379 _ " �> , 17av 737 o q /S— �. __ .a...c.y �Y���� 71 'fU j � -{:•r..� rz, fiv c'iT .. t. f 9,. I S may, / . TOTALS --- --- A. HEAT LOSS FROM BUILDING B.T.U./HR. B. DOMESTIC HOT WATER DEMAND B.T.U./HR. C. PIPING, OTHER THAN NORMAL B.T.U./HR. ALLOWANCE FOR HEAT VALVE OF FUEL (A 7B CC)) FACTOR 17. ELECTRICAL WORK BY:-- NAML ADDRESS SUBCONTRACTORS AND 1e. THEIR TRADES ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE(OWNER) OR (AGENT) OF THIS PROPERTY AND WILL BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE, APPLICATION TO BE COMPLETELY FILLED IN. �?e DATE SIGNATURE OF APPLICANT