Loading...
HomeMy WebLinkAbout14 Abar Lane (8) PERMIT # Application For 6847 5747 DEPARTMENT DECISION Heating Permit ° 3 APPLICATION Is HEREBY: DEPARTMENT OF LICENSES AND INSPECTIONS o a� N )C] APPROVED SAPPROVED TOWN OF SOUTH WINDSOR o Id d DA C EF INSPECTOR APPLICATIONS MUST BE PRINTED OR TYPED. BEGIN WITH NUMBER ONE BELOW ol o 1. LOCATION OF JOB O 10 Lane Cis TREET cd O) y .0 LOT NO. FLOOR APT. NO. 4 O 0 O) O r. E 2. OWNERGhL// Cd 1. ba ° S. ADDRESS // ��) �n ♦dam�/ CS°Ur1 (.(/ !/ 4.PHONE C*3 S. APPLICANT ,Oy7/7 /., •f+�a/ ��6 �/Y�G PC s. ADDRESS b /� /-2 1 J(/re GVen �`/ 7.PHONEJ.B Pell S. LICENSE NO. L70 7/9a s s. EXPIRATION DATE OF LICENSE c� c ! A 10. ESTIMATED COST o N 11. IS THIS A CONTRACT COST? YES ❑ NO 60 12. FEE ENCLOSED s Permit 13432 Co 13. TYPE OF BUILDING: NO !— RESIDENTIAL ❑ COMMERCIAL O G 3 14. TYPE OF JOB: ❑ INDUSTRIAL ALTERATI ORIGINAL ~ INSTALLATION ❑ ADDITIONON REPAIR APPLICATION FOR HEATING PERMIT (c nttnued from Revere Side) 11. LOCATION OF JOB_ Ld 941/12 NO. —�� STREET FLOOR APT. NO. 12. TYPE OF INSTALLATION: ❑ OIL BURNER ❑ ELECTRIC Cl VENTILATION ❑ SPRINKLER I GAS BURNER El STACK El INCINERATOR � MISCELLANEOUS 64 ( IDENTIFY SIZE LOCATION SIZE SIZE 13. OF TANK OF TANK OF FILL OF VENT 14. B.T.U. EQUIP. AT REGISTER FURNACE MAKE AND NO. AT BONNET FIRING RATE BOILER OR FURNACE MAKE AND NO. An/o B.T.U. OR SQ. FT. NET B.T.U. OR SQ. FT. GROSS FIRING RATE FLOORS TO BE HEATED i7ly—i NEW OR OLD BUILDING -, INSULATED — YES OR NO -f TYPE OF WALL WiLrd t w INSULATION INSULATION ROOF OR CEILING p� tie r� AVG. SYSTEM WATER TEMP. �� y B.T.U./SQ. FT./HR. EMISSION INDOOR-OUTDOOR TEMPERATURE DIFFERENCE 0—ga" °FAHRENHEIT MAKE OF RADIATION. B SEBO . COPPER CO�VE�PRS, OR C.I. RADIATION. OUTPUT PER SECTION OR LINEAL OF RADIATION. SQ. FT. OR B.T.U. le T � DESCRIs. TO BE I OINE;ON OF WORKj/Cif 16. HEAT LOSS SCHEDULE. (TO BE INCLUDED FOR ALL JOBS): ROOM SIZE wlNDows AREA - SQUARE FEET B.T.U. e.T.u. DISTRIBUTION INSTALLED AND DOORS VOLUME TOTAL TOTAL y ROOM NO. GROSS GLASS NET WALL CEILING FLOOR CU.FT. AT TD•F CORRECTED J j 4 4 REGISTER L W M AND Q TEMP. TO r TYPE AND SIZE RAD. OR LEADER lIZE < WALL f'�TO (INFILT.) DIFF. •F m N SQ. FT. FREE AREA TOTALS A. HEAT LOSS FROM BUILDING B.T.U./HR. B. DOMESTIC HOT WATER DEMAND 12 Gs B.T.U./HR. C. PIPING. OTHER THAN NORMAL B.T.U./HR. ALLOWANCE FOR HEAT VALVE OF FUEL (A B/ C) FACTOR EL 17. ELECTRICAL WORK BY: ( y1.1C A / NAME ADDRESS SUBCONTRACTORS AND 18. THEIR TRADES ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE (OWNER) OR (AGENT) OF THIS PROPERTY AND WILL BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE. APPLICATION TO BE COMPLETELY FILLED IN. �J��, ✓ 7 DATE SIGNAT APPLICANT K , CONSTRUCTION- WALL WINDbWS ROOF OR CEILING BASEMENT HEIGHT: ABOVE GRADE BELOW GRADE DESIGN WATER TEMPERATURE DESIGN TEMP. DIFF COL.1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 ROOM SIZE WINDOWS AREA•SQ. FT. FLOOR VOLUME BASEBOARDS AND DOORS CU. FT TO tA1. 'TOTAL l3[E NOTE) CORRECTED ACCESSORIES ROOM NuwLER GROSS GLASS NET WALL CEILING n AT:'D. WATER LENGTH . O / TE'.IF. TO T1;MP ni, F ENCLOSURE L R S 14 MISC. L W H oN AREA WALL c � DI IF. � FIN 512E „i 7 . 0 Z 7 TUBE 1. 13 0 2 0 1 oS TEMP DIFF. FT, a 1 069 /3 81 ' / 00 900 ))00 da oo 1200 00 o o a 600 78Dv 8 / /6 y8 ( Y CL v- G g`''• !/ 00 d o goo "700 a Soo /a o 1 0o yoo 00 3 3 >< /yoo oo soo oa 2300 `000 ,440 13 ` _ G a * 1 Io 4, //0 2- o ►3-�a /o ,r �00 Roo 600 yoo /zoo ` 9©D 5600 /0 io o 00 13n, to l0 8 ?00 DD Soo / oo /000 2v0iD 3 NOTE: FOR CONCRETE FLOOR ON GROUND OR FILL AT GRADE LEVEL,USE LINEAR FELT OF EXPOSED EDGE. TOTALS rA_l 04n '"�n