HomeMy WebLinkAbout109 Bridlewood Road (6) DEPARTMENT DECISION PERNUT4 APPLICATION FOR HVAC PERMIT Application is hereby: TOWN of SOUTH WINDSOR BUILDING DEPARTMENT Bldg Permit# APPROVED 1540 SULLIVAN AVENUE 644-2511 ext. 230 Date Building Inspector Application must be printed or typed Location of job Street No. Street Lot No. FEE SCHEDULE X6 I (15 ^ Floor Apt. No. $o - $1,000 - siarw� ,s Over $1,000 -Um"r$1,000 OWNER IZ) or any fraction thereof ADDRESS &7LF 5-1- Q' k -�� So . ����� s�� C a� � '7 �� OWNERS PHONE# APPLICANT 17Ad Ila ADDRESS 76 Z/-c r 0 (0 ESTIMATED COST $ 0 JcS0 IS THIS A CONTRACT COST? YES NO /* Aw - 0 e- FEE ENCLOSED $ OR-Co TYPE OF JOB: 9:,�igginal Installation Alteration/Addition/Repair Revised 11/95 APPLICATION FOR HVAC PERMIT(Continued from rcvcrsc side) TYPE OF SYSTEM TYPE OF BUILDING HEATING RESIDENTIAL A/C COMMERCIAL VENTILATION INDUSTRIAL HEATING STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIRS-- UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE a F INSIDET-;�> F DIFFERENCE$ n F TOTAL HEAT LOSS(BTUH) -3!I l�Z (HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING QUIPMENT (INCLUDING MAKE&MODEL NO.) /C 'LL a `z11-5- c" / C rn2 c- ,a GROSS HEATING CAPACITY (INPUT-BTUH) NET RATING (OUTPUT-BTUH) /5-/ o o TYPE OF FUEL OIL-GPM t/ GAS-INPUT ELECTRIC-KW OIL TANK SIZE&LOCATION INSIDE OUTSIDE CAPACITY LPG TANK CAPACITY AIR CONDITIONING DESIGN TEMP. OUTSIDE I F INSIDE75�F DIFFERENCE Z o F TOTAL HEAT GAIN(BTUH)3c 2,C. (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE&MODEL NO.) ?5-15�C 5`V8 e ✓afo C, r— c TONNAGE COOLING CAPACITY(BTUH) 19617�) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONN.BUILDING CODES IN T PERFORMANCE OF SUCH WORK. 3C) ,36 /C7/ X STATE LICENSE-NO. NAME&TYPE SIGN7e,2 E O L CANT PHONE NO.�9� O, DATE ; � - No of Doors ; 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Floor Width. ; 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Floor Length ; 0.0 0.0 0.0 0.0 0.0 8.0 0.0 Roof Width 13.0 0.0 0.0 0.0 0.0 0.0 0.0 Roof Length ; 12.0 0.0 0.0 0.0 0.0 0.0 0.0 -------------------- -------- -------- -------- -------- -------- -------- -------- ---------------------- ------- Area Cubic Feet 1,248 0 0 0 0 0 0 Total anber of people 4 Gross Wall sq/ft 112 0 0 0 0 0 0 Total Gross Wall Sq/Ft 2,763 Net Wall sq/ft 84 0 0 0 0 0 0 Total Net Wall Sq/Ft 2,492 Wall Heating BTU 470 0 0 0 0 0 0 All Walls Heating BTU 13,952 Wall Cooling BTU 168 0 0 0 0 0 0 All Walls Cooling BTU 4,983 S/W Glass sq/ft 28 0 0 0 0 0 0 Square Feet S/W Glass 112 S/W Glass Heating BTU 1,389 0 0 0 0 0 0 Ttl Heat/BTU S/W Glass 5,555 S/W Glass Cooling BTU 347 0 0 0 0 0 0 Ttl Cool/BTU S/W Glass 1,389 S/W Glass Solar BTU 2,240 0 0 0 0 0 0 Solar BTU's S/W Glass 8,960 N/E Glass sq/ft 0 0 0 0 0 0 0 Square Feet M/E Glass 117 N/E Glass Heating BTU 0 0 0 0 0 0 0 Ttl Heat/BTU N/E Glass 5,803 N/E Glass Cooling BTU 0 0 0 0 0 0 0 Ttl Cool/BTU N/E Glass 1,451 N/E Glass Solar BTU 0 0 0 0 0 0 0 Solar BTU's N/E Glass 4,680 Doors sq/ft 0 0 0 0 0 0 0 Door Heating BTU 0 0 0 0 0 0 0 Total Door Heating BTU 1,075 Door Cooling BTU 0 0 0 0 0 0 0 Total Door Cooling BTU 336 Floor sq/ft 156 0 0 0 0 0 0 Floor Heating BTU 0 0 0 0 0 0 0 Total Floor Heat BTU 1,728 Floor Cooling BTU 0 0 0 0 0 0 0 Total Floor Cool BTU 0 Roof sq/f t 156 0 0 0 0 0 0 Roof Heating BTU 374 0 0 0 0 0 0 Total Roof Heating BTU 3,223 Roof Cooling BTU 156 0 0 0 0 0 0 Total Roof Cooling BTU 1,343 Lights Cooling BTU 133 0 0 0 0 0 0 Lighting Cooling BTU 1,146 Appliance Cooling BTU 164 0 0 0 0 0 0 Appliance Cooling BTU 1,410 People Cooling BTU 105 0 0 0 0 0 0 Ttl People Cooling BTU 900 Latent Cooling BTU 93 0 0 0 0 0 0 Ttl Latent Cooling BTU 800 Ventilation Heat BTU 402 0 0 0 0 0 0 18% Vent. Heat BTU 5,641 Ventilation Cool BTU 613 0 0 0 0 0 0 18% Vent. Cool BTU 4,932 Duct Heat Loss BTU 158 0 0 0 0 0 0 6% Ductloss H/BTU 2,219 Duct Cool Loss BTU 241 0 0 0 0 0 0 6% Ductloss C/BTU 1,940 --------------------- ------ ------ ------ ------ ------ ------ ------ ---------------------- ------- Area Heating BTU 2,794 0 0 0 0 0 0 Heating BTU/Sq/Ft ---> 29.18 Area Cooling BTU 4,260 0 0 0 0 0 0 Cooling BTU/Sq/Ft ---> 25.51 Area Air Heating CFM 37 0 0 0 0 0 0 Area Air Cooling CFM 142 0 0 0 0 0 0 Heating BTU's per CFM -> 75.98 Cooling BTU's per CFM -> 30.00 ------------------------ ----- Building. Heat BTU/Cu/Ft -> 2.90 Building. Cool BTU/Cu/Ft -> 2.54 09/23/99 HEATING/COOLING BTU ESTIMAT: ADVANCE HEATING JOB NAME: Wilsar Const, So, Windsor DESIGN CONDITIONS TOTAL BLDG, HEAT LOSS/GAIN PHONE 528-3564 878 Strong Rd. CT. ----------------- ------- -------------------------- BLDG : 109 Bridlerood Rd. Heating: 80 deg f.t/d BLDG Heat Loss BTU 39,197 Estimator: NOTES: Cooling: 20 deg f.t/d BLDG A/C Gain BTU 34,269 Stephen Smith Room 1 Roos 2 Roos 3 Room 4 Room 5 Room 6 Room 7 Room 8 Root 9 Room 10 Roos 11 Room 12 AREA NAME; Dining Foyer Living Family Dinette Kitchen Master Mas Lav Mas Clos Bed 1 Bed 2 Lav Outside Wall Length; 28.0 17.0 28.5 34.0 12.0 28.0 25.0 19.5 33.0 30.5 24.0 8.0 Outside Wall Height; 9.0 18.0 9.0 9.0 9.0 9.0 10.0 8.0 8.0 8.0 8.0 8.0 Sq/Ft S or W Glass ; 0.0 0.0 0.0 20.0 28.0 9.0 0.0 7.5 0.0 0.0 12.0 7.5 Sq/Ft N or E Glass ; 24.0 27.0 24.0 0.0 0.0 0.0 18.0 0.0 0.0 24.0 0.0 0.0 No of Doors ; 0.0 0.0 0.0 1.0 0.0 1.0 0.0 0.0 0.0 0.0 0.0 0.0 Floor Width ; 0.0 010 0.0 0.0 0.0 0.0 0.0 0.0 12.0 0.0 0.0 0.0 Floor Length ; 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 9.0 0.0 0.0 0.0 Roof Width ; 0.0 13.0 0.0 0.0 0.0 0.0 14.0 10.0 12.0 16.5 10.0 8.0 Roof Length ; 0.0 17.0 0.0 0.0 0.0 0.0 20.0 9.5 9.0 14.0 14.0 14.0 -------------------- -------- -------- -------- -------- -------- -------- -------- -------- -------- -------- -------- -------- Area Cubic Feet 0 3,978 0 0 0 0 2,800 760 864 1,848 1,120 896 Gross Wall sq/ft 252 306 257 306 108 252 250 156 264 244 192 64 Net Wall sq/ft 228 279 233 265 80 222 232 149 264 220 180 57 Wall Heating BTU 1,277 1,562 1,302 1,484 448 1,243 1,299 832 1,478 1,232 1,008 316 Wall Cooling BTU 456 558 465 530 160 444 464 297 528 440 360 113 S/W Glass sq/ft 0 0 0 20 28 9 0 8 0 0 12 8 S/W Glass Heating BTU 0 0 0 992 1,389 446 0 372 0 0 595 372 S/W Glass Cooling BTU 0 0 0 248 347 112 0 93 0 0 149 93 S/W Glass Solar BTU 0 0 0 1,600 2,240 720 0 600 0 0 960 600 N/E Glass sq/ft 24 27 24 0 0 0 18 0 0 24 0 0 N/E Glass Heating BTU 1,190 1,339 1,190 0 0 0 893 0 0 1,190 0 0 N/E Glass Cooling BTU 298 335 298 0 0 0 223 0 0 298 0 0 N/E Glass Solar BTU 960 1,080 960 0 0 0 720 0 0 960 0 0 Doors sq/ft 0 0 0 21 0 21 0 0 0 0 0 0 Door Heating BTU 0 0 0 538 0 538 0 0 0 0 0 0 Door Cooling BTU 0 0 0 168 0 168 0 0 0 0 0 0 Floor sq/ft 0 221 0 0 0 0 280 95 108 231 140 112 Floor Heating BTU 0 0 0 0 0 0 0 0 1,728 0 0 0 Floor Cooling BTU 0 0 0 0 0 0 0 0 0 0 0 0 Roof sq/ft 0 221 0 0 0 0 280 95 108 231 140 112 Roof Heating BTU 0 530 0 0 0 0 672 228 259 554 336 269 Roof Cooling BTU 0 221 0 0 0 0 280 95 108 231 140 112 Lights Cooling BTU 0 189 0 0 0 0 239 81 92 197 119 96 Appliance Cooling BTU 0 232 0 0 0 0 294 100 113 243 147 118 People Cooling BTU 0 148 0 0 0 0 188 64 72 155 94 75 Latent Cooling BTU 0 132 0 0 0 0 167 57 64 138 83 67 Ventilation Heat BTU 444 618 449 542 331 401 516 258 624 536 349 172 Ventilation Cool BTU 308 521 310 458 494 260 463 249 176 479 369 229 Duct Heat Loss BTU 175 243 176 213 130 158 203 101 245 211 137 68 Duct Cool Loss BTU 121 205 122 180 195 102 182 98 69 188 145 90 --------------------- ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ Area Heating BTU 3,086 4,293 3,117 3,769 2,297 2,786 3,582 1,791 4,335 3,723 2,426 1,197 Area Cooling BTU 2,144 3,620 2,155 3,185 3,436 1,806 3,220 1,734 1,224 3,328 2,567 1,592 Area Air Heating CFM 4I 56 41 50 30 37 47 24 57 49 32 16 Area Air Cooling CFM 71 121 72 106 115 60 107 58 41 111 86 53 TTL Building. Square feet-> 11343 Heating Air Changes/Hour -> 2.29 TTL Building. Cubic feet-> 139514 Cooling Air Changes/Hour -> 5.07 --------------------------- ------ ---------- ------- ----- ----- TTL Building Heating CFM -> 516 Heating CFM per SQ/FT -> 0.38 TTL Building Cooling CFM -> 1,142 Cooling CFM per SQ/FT -> 0.85 09/23/99 HEATING/COOLING BTU ESTIMAT: ADVANCE HEATING JOB NAME: Wilsar Const. So. Windsor PHONE 528-3564 878 Strong Rd. CT. BLDG : 109 Bridlerood Rd. Estimator: NOTES: Stephen Smith Room 13 Room 14 Room 15 Room 16 Roos 17 Room 18 Room 19 AREA NAME; Bed 3 Outside Wall Length; 14.0 0.0 0.0 0.0 0.0 0.0 0.0 Outside Wall Height; 8.0 8.0 8.0 8.0 8.0 8.0 8.0 Sq/Ft S or W Glass ' 28.0 0.0 0.0 0.0 0.0 0.0 0.0 Sq/Ft N or E Glass ; 0.0 0.0 0.0 0.0 0.0 0.0 0.0