Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
171 Bourbon Street (9)
UN Ur r ii.z 4JZ V .,1 (NO AwU ) APPLICATION FOR HVAC PERMIT DATE SLDG• 1tiT NO. Lz T OF SOUTH wINDSOR EST. c�oSTQ©4. o 1540 SULLIVAN AVENUE SOUTH S4INDSOR � CT. 06074 FEES; ' $ 1 .00 - $ 200 $3.00 LOCATION OF BUILDING 1/7/ $2 01 .0 0 - $ 600 $4.•0 0 5 7- 1 $601 .00 - $l o00 $6.o .� �.. 0 or OiiNER fraction thereof ADDRESS TOWN o /oFHONEF-IM O --- -- AVAC CONTRACTOR ADDRESS o 1? S 6J1n1 T>Seye T0� PRONE N0. TYPE OF SYSTEM: HEATING -A-8a- o a o J_� A/C TYPE OF BUILDING: RESIDENTIAL VENTILATION COCA' - BUSINESS _ INDUSTRIAL IF HEATING: STEAM_ --- LOW PRESSURE LIMIT_LBS. HIGH PRESSURE LIMIT S, HYDRONIC W IA R_ UNIT RADIANT HEATER(INCLUDING WOOD/CO BURNING URNING STOVE) • TYPE OF FUEL: OIL-GPM GAS INPUT ELECTRIC KW WOOD COAL OIL TANK - SIZE b LOCATION: INSIDE OUTSIDE CAPACITY LPG TANK - CAPACITY_ ----- EXISTING RADIATION A$DITIONAL RADIATI$_ TOTAL RADIATION DESIGN TEMP. OUTSIDE _ F INSIDE_ F DIFFERENCE_ F TOTAL HEAT LOSS (BTUH) (HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE & MODEL NO.): GROSS HEATING CAPACITY (INPUT-BTUH) NET RATING (OUTPUT-BTUH)_ IF AIR CONDITIONING: DESIGN TEMP. OUTSIDE IrF INSIDE.7eF DIFFERENCE °F TOTAL HEAT GAIN (BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE b MODEL .):_�rh ;p,5 7�1- ,BC'm 06()A k,4 C'' � TONNAGE COOLING CAPACITY(BTUH) IF VENTILATION: DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING-KITCHEN EXHAUST EQUIPMENT): TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM) (PLAN MUST ACCOMPANY APPLICATION) The undersigned hereby applies for a permit to perform the following work and is to comply with all local ordinances and State of Conn. Building Codes in the perf rmance of such work. FURTHER DESCRIPTION OF WORK: 3 STATE LICEN E-N b TYPE DATE S ATURE OF APPL CANT APPROVED ' ____ DATE Copyright 1977 by The Hydr wka Institute Ft CALCULATION SHEET 1503 lModN'n Method( DESIGN T[MPERATUR[O/FFERENCE F. DATE ADDRESS ONER COL.O COL.[ COL.F COL.O MI COL.A COL.B COL.C 1 ROOM Q H W Design Water Temp. O H L W H L W N L W H L W L BTUH per Foot of H 2 ROOM DIMENSIONS,FT. U Realetlow Selected 3 LENGTH EXPOSED WALLS,FT. 4 I► 4 WINDOW AND OUTSIDE DOOR AREA BTUH BTUH STUN BTUH STUN ROOM LIN.FT.OF 5 WALL CONSTRUCTION TOTALS RADIATION FROM LINE 12 SELECTED (Table 9,Line 3 x H) 6 TYPE OF GLASS is ttom of table used for Line 5) C 7 CEILING CONSTRUCTION D (Table 9,L x W) E - B FLOOR CONSTRUCTIONt (Table 9,L x W or Lin.Ft) IF 9 COLD PARTITION CONSTRUCTION a (Table 9.L x H) H O 10 r 1 Well(With Openlr4W =C e � 2 Wells(With Openings) Q J 3 Wails(With Openings)or Ent.Hall 1- 11 TOTAL BTUH AT 70F TEMP.DIFFERENCE' K 12 TOTAL BTUH AT DESIGN TEMP.DIFFERENCE L COL COL-9 COL.H COL.1 COL.J COL'K COL.L TOTALBTUH TOTAL A -- OF BUILDING RADIATION - AT SELECTED 1 ROOM ¢ H L W H L W H L W DESIGN TEMP-0 O H L W H L W DIFFERENCE 2 ROOM DIMENSIONS.FT. U Q 3 LENGTH EXPOSED WALLS,FT LL 4 WINDOW AND OUTSIDE DOOR AREA — BTUH BTUH BTUH STUN BTUH •INCREASE BATHROOM TOTAL 2096 5 WALL CONSTRUCTION (Table 9.Line 3 x H) 6 TYPE OF GLASS tFOR CONCRETE FLOOR ON (Bottom of.table used for Line 5) _ GROUND OR FILL AT 7 GRADE LEVEL,USE LINEAR CEILING CONSTRUCTION FEET OF EXPOSED EDGE (Table 9,L x W) g FLOOR CONSTRUCTION? (Table 9,L x W or Lin.Ft) _ 9 COLD PARTITION CONSTRUCTION (Table 9,L x H) O 10 C 1 Well I W ith Openings) 3 eX c 2 Walls(Woth Openings) J 3 Walls(With Openings)or Ent.Hall H 11 TOTAL BTUH AT 70F TEMP.DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP.DIFFERENCE FORM 1503 This form is available from The Hydronics Institute,35 Russo Place,Berkeley Heights,N.J.07922 c ,•, : .�•, .4 t` .y HALL 132 �•� •'�� 1 1 ,GLASS 66 .. . :bath � 1,328 10786 •, � ;•••: �• AREA GAIN LOSS CEILING 234 382 394 i r' e - ' MISC 600 0 . FLOOR 78 8 ------- --•230 i --- WALL 36 95 249 I SUB-TOTAL 2r 434 3i 393 CEILING 78 114 123 , SUB-TOTAL 208 654 6: 1 1 V AREA WIN LOSS 12: h a l l f o y e r FLOOR 216 0 824 HALL n 122 320 AREA GAIN LOSS GLASS 24 622 849 FLOOR 160 8 526 CEILING 218 '352 538 CEILING 168 --_ 261 409 MISC R U U D SUB-TOTAL _ _ LOAD FACTS TOTAL 929 10333� 8 SF'+SIBLE GAIN LOSS 261 926 SUB-TOTAL 1,397 2,134 L T• Is sae 4,435 L 2,855 6,66332 ". SUMMARY & TOTALS 7:k i t ch e n Res i de nt i a l Load 9 SENSIBLE GAIN LOSS 1.; SUMMER ACiHR= 0, 4 AREA GAIN LOSS A ED. OTAL 1,237 1,826 FLOOR 230 0 LT. "Ift 3's96 WINTER AC/HR= 1 HALL Ise L 2r232 6,024 U E N T I L A T I O N C F M= sLpss 32 34 142 DESIGN DATA 48 9a0 1,299 WINTER OUTSIDE TEM 0 10 SENSIBLE GAIN LOSS 3 0 0 CEILING y� WINTER INSIDE TEMP 75 375 374 SUMMER OUTSIDE DB 95 )TAL 832 1r 509 MISC SUMMER INSIDE TEMP 70 T• B88 3,698 AREA 1 1,800 8 SUMMER DAILY RANGE 25 520 SENSIBLE GAIN LOSS SUMMER MOISTURE 60 35 1,8B6 Sr 725 SUBTOTAL 1,114 2,002 SUB-TOTAL 30189 INFILT. DUCT 11 SENSIBLE GAIN LOSS TOTAL Sa2 33 2'212 2r 773 421 1 :r m 1001 1,729 4,641 TAL 293 854 o AREA GAIN LOSS 18 w AREA 2 d l n i n SENSIBLE GAIN 8: g r m 11100R 136 8 438 218 718 �,� LOSS SUBTOTAL 1*382 2 AREA GAIN LOSS WALL Is$ 313 832 INFILT. 1,888 ,379 12 SENSIBLE GAIN LOSS DUCT 4r435 'FLOOR 138 TOTAL 2,122 683 0 378 GLASS 12 240 324 fAL 261 $26 7,435 MALL 36 13 92 T. 93 249 CEILING 138 254 390 274 1,018 AREA 3 SENSIBLE GAIN Lass ,GLASS 24 822 G49 MISC 300 0 SUBTOTAL 979 CEILING 130 212 INFILT. 533 1,435 325 DUCT 2r 217 -` - --- SUB-TOTAL 1,114 2,862 A L LOSS TOTAL 10382 4,812 ISUB-TOTAL 929 1,589 7 4, 9 7 8 ;+ AREA 4 SENSIBLE GAIN LOSS j S AST°TAL 1 2:rm 1003 AL LATENT GAIN f �OTAL 420 ''133 r 9'rm 1018 437 AREA GAIN LOSS 1,483 AREA GAIN 1 1, 4 5 5 LOSS FLOOR 169 8 489 , AREA 5 SENSIBLE GAIN FLOOR 168 0 LOSS 488 WALL 164 312 819 SUBTOTAA L SENSIBLE I INFILT 3,395 WALL 84 142 374 GLASS 24 294 649 DUCT 2,333 12m 138 21), 255 TOTAL 288 1,553 GLASS 20 518 341 CEILING 168 276 422 30W3 I7,150 CEILING 168 276 422 ------- AREA 6 SENSIBLE GAIN MISC SUB-TOTAL 1,382 2,329 a L GAIN Loss 3e0 e 3 8, 220 SUBTOTAL 1,397 INFILT. 1,888 2r 134 SUB-TOTAL lr 237 DUCT 4,435 1 825 TOTAL 2,586 7,228 68 3:rm 1002 AREA J SENSIBLE GAIN LOSS 10:r m 1020 AREA GAIN LOSS SUBTOTAL FLOOR 130 8 373 INFILT. 'RIGHT D SLEETH 3,138 2rJ73 DUCT 2'288 8,820 AREA GAIN LOSS WALL 92 156 409 3-384-5775 l,184 FLOOR 5,589 12,807 338 0 375 GLASS 12 311 324 WALL 68 101 287 CEILING 130 212 323 GLASS 20 518 341 MISC 300 0 CEILING 138 -_-_-- 212 325 --`_-- -- SUB-TOTAL 979 19433 SUB-TOTAL 832 1,508 4:but hroom AREA GAIN LOSS FLOOR 138 0 513 WALL 96 163 427 CEILING 136 254 390 SUB-TOTAL 412 19330