HomeMy WebLinkAbout151 Birch Hill Drive (4) L 8 & a adrab IKLU
PERMIT #
Application For 3 033 2811
DEPARTMENT DECISION Heating Permit
� O
APPLICATION IS HEREBY: DEPARTMENT OF LICENSES AND INSPECTIONS
tq +' �APPROVED � DISAPPROVED
TOWN OF SOUTH WINDSOR
Cd
6-11-b
p+ I APPLICATIONS MUST BE PRINTED OR TYPED. BEGIN WITH NUMBER ONE BEL W
00 y DATE
-0
1. LOCATION OF JOB
0
O, STREET
cis q
v
� w LOT NO. FLOOR APT. NO.
� o
N
ice) 0 2. OWNER
Cd
C S. ADDRESS -,::e ol
0
NOD
4.PHONE
A S. APPLICANT
rn
c w e. ADDRESS
S 7.PHONE-C2-,?4
co
y S. LICENSE NO.
9. EXPIRATION DATE OF LICENSE
w
o ^�
a� 10. ESTIMATED COST S d�
� c
11. IS THIII A CONTRACT COST? 0 YES 0
12. FEE ENCLOSED S Permit #4781
13. TYPE OF BU LDING:
CA
c�
an RESIDENTIAL COMMERCIAL
O .
14. TYPE;
YPE OF JO INDUSTRIAL
GHNAIL INSTALLATION ALTERATION
ADDITION
REPAIR
n�
I APPLICATION FOR HEATING PERMIT (Continued it m Reverse Side)
1 1, LOCATION OF JOB -
_ji.� NO. STREET FLOOR APT. NO.
12. TYPE OF INSTALLATION: ® OIL BURNER ® HEATING SYSTEM ❑ VENTILATION ❑ SPRINKLER
❑ GAS BURNER ❑ STACK ❑ INCINERATOR ❑ MISCELLANEOUS
IDENTIFY
SIZE SIZESIZE
13. OF TANK 275 OFCTANKN Cellar OF FILL 2" OF VENT lit"
14. B.T.U. EQUIP. AT REGISTER FURNACE MAKE AND NO. AT BONNET FIRING RATE •
BOILER OR FURNACE MAKE AND NO.129 t 000 B.T.U. OR SQ. FT. NET 860 B.T.U. OR SQ. FT. GROSS FIRING RATE
FLOORS TO BE HEATED lit & 3114 NEW OR OLD BUILDING ns INSULATED -- YES OR NO yoks
TYPE OF WALL fXaU" INSULATION Z" ROOF OR CEILING 2" INSULATION fb ass
AVG. SYSTEM WATER TEMP. 1800 B.T.U./SQ. FT./HR. EMISSION
INDOOR-OUTDOOR TEMPERATURE DIFFERENCE 0 " 700 °FAHRENHEIT
MAKE OF RADIATION: BASEBOARD, COPPER CONVECTORS, OR G.I. RADIATION. OUTPUT PER SECTION OR LINEAL OF RADIATION. SQ.
FT. OR B.T.U. a1 t►asebaasd Xw%1 QC 8" 610 "V_ - 18&
DESCRIPTION OF WORK ra,Cld hot water, baseboard,, dean Standard15. TO BE DONE;
2 sans.
16. HEAT LOSS SCHEDULE. (TO BE INCLUDED FOR ALL JOBS):
ROOM SIZE WINDOWS AREA - SQUARE FEET B.T.U. B.T.U.AND DOORS o< DISTRIBUTION INSTALLED
VOLUME
TOTAL TOTAL y
ROOM NO' < GROSS GLASS NET WALL CEILING FLOOR CU.FT. AT 70°F CORRECTED J j LL REGISTER
L W H AND It IW TEMP. < ci TYPE AND SIZE RAD' OR LEADER
SIZE P 10 WALL (INFILT.)
� DIFF. TO °F O m H SQ. FT. FREE AREA
1 13 10 10 .018
Sed 1510
Bad i6 11 b 21 "
3 11 6 184 is I I1010 «
2444 10 12 6 4800 8' «
Bath 3 6 6 3*811
«
Liv 14 187 6 854 &SO oc 17w
t a
13 Z4 6 0 ' « lit,
Den 9 120 0 "
Lawn.,S 7 6 2' "
-33
Sath S 6 6 41 «
TOTALS "a 9 E «
A. HEAT LOSS FROM BUILDING 86 y480 B.T.U./HR.
B. DOMESTIC HOT WATER DEMAND 224500 B.T.U./HR.
C. PIPING, OTHER THAN NORMAL 300000 B.T.U./HR.
ALLOWANCE FOR HEAT VALVE OF FUEL (A B C) FACTOR
17. ELECTRICAL WORK BY:
NAME ADDRESS
SUBCONTRACTORS AND
18. THEIR TRADES
ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE (OWNER) OR (AGENT) OF THIS PROPERTY AND WILL
BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE.
APPLICATION TO BE COMPLETELY FILLED IN.
DATE SIGNATURE OF APPLIeXNT