HomeMy WebLinkAbout140 Birch Hill Drive (5) PERMIT #
Application For 2837
2 DEPARTMENT DECISION 3059
Heatmg Permit
cd
3 APPLICATION IS HEREBY: DEPARTMENT OF LICENSES AND INSPECTIONS
APPROVED DISAPPROVED
TOWN OF SOUTH WINDSOR
o cd X1lXx 8-6-64
00 O DATE CHIEF INWCTQR APPLICATIONS MUST BE PRINTED OR TYPED. BEGIN WITH NUMBER ONE BEL W
O
v] .Q
C -8 1. LOCATION OF JOB
i0-i C r
� �9 NO. STREET
4-� O
C. 1-44
,z0", LOT NO. FLOOR APT. NO.
� O
LV
O O
2. OWNER
ca
Z O S. ADDRESS
4.PHONE
c
&022 S. APPLICANT
O o° s. ADDRESS
k CD 7.PHONE" 2?4!-r!
S. LICENSE NO. L ( 3
� 43 s. EXPIRATION DATE OF LICENSE �
0
10. ESTIMATED COST S Z
m c
z '-' 11. IS THIS A CONTRACT COST? ❑ YES 9 NO
t�
12. FEE ENCLOSED S Permit #49117
4
y 13. TYP O�F DING:
U RESIDENTIAL ❑ COMMERCIAL
O �
G 14. TYPE OF J ❑ INDUSTRIAL
IGINAL ALTERATION
INSTALLATION ❑ ADDITION
REPAIR
APPLICATION FOR HEATING PERMIT (Continued tr m Reverse Side)
111�11. LOCATION OF JOB Lot #20 Birch Hill Rd, lst & 2nd
NO. STREET FLOOR APT.NO.
/ 12. TYPE OF INSTALLATION: ® OIL BURNER ® HEATING SYSTEM ❑ VENTILATION ❑ SPRINKLER
❑ GAS BURNER ❑ STACK ❑ INCINERATOR ❑ MISCELLANEOUS
IDENTIFYSIZE SIZE �_
SIZE
13. OF TANK 275 OF TANKN cellar OF FILL 2" OF VENT 13N
14. B.T.U. EQUIP. AT REGISTER FURNACE MAKE AND NO. AT BONNET FIRING RATE 1-7
BOILER OR FURNACE MAKE AND NO. 129,000 B.T.U. OR SQ. FT. NET 860 B.T.U. OR SQ. FT. GROSS FIRING RATE
FLOORS TO BE HEATED 18t & 2nd NEW OR OLD BUILDING neW INSULATED - YES OR NO Yes
TYPE OF WALL Pram INSULATION 2" ROOF OR CEILING 2" INSULATION fibergl.aea
AVG. SYSTEM WATER TEMP. 1600 B.T.U./SQ. FT./HR. EMISSION
INDOOR-OUTDOOR TEMPERATURE DIFFERENCE 0 - 700 °FAHRENHEIT
MAKE OF RADIATION: BASEBOARD, COPPER CONVECTORS, OR C.I. RADIATION. OUTPUT PER SECTION OR LINEAL OF RADIATION. SQ.
FT. OR B.T.U. Federal baseboard Model QC 8" 610 BTU — 1800
DESCRIPTION OF WORK Forced hot welter, with baseboard American Standard
15. TO BE DONE:
2 zones.
16. HEAT LOSS SCHEDULE. (TO BE INCLUDED FOR ALL JOBS):
ROOM SIZE WINDOWS AREA — SQUARE FEET B•T•U• B•T•U• Ir<h DISTRIBUTION INSTALLED
AND DOORS VOLUME TOTAL TOTAL m
ROOM NO. < GROSS GLASS NET WALL CEILING FLOOR CU.FT. AT 70•F CORRECTED J j LL LL REGISTER
L W N AND WE TEMP. TO F F TYPE AND SIZE RAD. OR LEADER
SIZE ` WALL �'ct0 (INFILT.1 DIFF. •F O a Sq. FT. FREE AREA
1 .10. .10 01
ed 15 10 7 22 180 12001 001 5600 10,
17 34 6800 12' "
"
GA 4
u
1 n
W 4 8 7 68 1060 17' "
2 4 7 60 0 1110 19' "
n 2 7 40 600 10' "
un 5 1 7 7 x 300 300 46 120 2' Is
84
a 7 "
TOTALS 5648 9g 1
A. HEAT LOSS FROM BUILDING 56,480 B.T.U./HR.
B. DOMESTIC HOT WATER DEMAND 22 A 500 B.T.U./HR.
C. PIPING, OTHER THAN NORMAL 20,000 B.T.U./HR.
ALLOWANCE FOR HEAT VALVE OF FUEL (A B C) FACTOR
17. ELECTRICAL WORK BY:
NAME ADDRESS
SUBCONTRACTORS AND
18. THEIR TRADES
ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE (OWNER) OR (AGENT) OF THIS PROPERTY AND WILL
BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE.
APPLICATION TO BE COMPLETELY FILLED IN. 2 �
DATE SIGN URE OF APPLICANT