Loading...
HomeMy WebLinkAbout19 Birch Road (5) Y PERMIT # Application For 2864 DEPARTMENT DECISION 3085 Heating Permit C'3 o c APPLICATION IS HEREBY: DEPARTMENT OF LICENSES AND INSPECTIONS N +' APPROVED DISAPPROVED .� TOWN OF SOUTH WINDSOR t�. — — 64 00 DAYt CHIEF PELT R i'� APPLICATIONS MUST BE PRINTED OR TYPED. BEGIN WITH NUMBER ONE BELOW O tM .� 1. LOCATION OF JOB Birch Hill Road C� 9 NO. STREET 45A 1st & 2nd LOT NO. FLOOR APT. NO. 0 O N ° 2. OWNER U & R Construction Co. ce ° 8. ADDRESS 55 E, Center St, , Manchester , bo 3 Connecticut 4.PHONE t! a. APPLICANT Long Hill Plumbing Co. , Inc. 0 w 6. ADDRESS 1247 Main Street, East Hartford, b a� Connecticut ,.PHONE 5 28-4151 6. LICENSE NO. 1139 o 4-49. EXPIRATION DATE OF LICENSE June 1, 1965 c� 10. ESTIMATED COST 0 *" 11. IS THIS A CONTRACT COS'Tf ❑ YES ® NO Permit #5034 12. FEE ENCLOSED S c� 1s. TYPE OF BUILDING: ❑X RESIDENTIAL ❑ COMMERCIAL bo .ram' .4j, ❑ INDUSTRIAL 14. TYPE OF JOB: ® RIGINAL El INSTALLATION ADDITION REPAIR APPLICATION FOR HEATING PERMIT (Continued it m Reverse Side) 11. LOCATION OF JOB Birch Hill Rd. 1st & 2nd 1, N0. STREET FLOOR APT. NO. 12. TYPE OF INSTALLATION: R OIL BURNER 0 HEATING SYSTEM ❑ VENTILATION ❑ SPRINKLER ❑ GAS BURNER ❑ STACK ❑ INCINERATOR ❑ MISCELLANEOUS IDENTIFY SIZE SIZESIZE 13. OF TANK 275 OF TANKN cellar OF FILL 2" OF VENT 1�4-' 14. B.T.U. EQUIP. AT REGISTER FURNACE MAKE AND NO. AT BONNET FIRING RATE BOILER OR FURNACE MAKE AND NO. 129 ,OOO B.T.U. OR SQ. FT. NET 860 B.T.U. OR SQ. FT. GROSS FIRING RATE FLOORS TO BE HEATED lSt & 2nd NEW OR OLD BUILDING new INSULATED - YES OR NO yes TYPE OF WALL frame INSULATION 2tL ROOF OR CEILING 211 INSULATION fiberglass AVG. SYSTEM WATER TEMP. 1800 B.T.U./SQ. FT./HR. EMISSION INDOOR-OUTDOOR TEMPERATURE DIFFERENCE 0 - 700 °FAHRENHEIT MAKE OF RADIATION: BASEBOARD. COPPER CONVECTORS, OR C.I. RADIATION. OUTPUT PER SECTION OR LINEAL OF RADIATION. SQ. FT. OR B.T.U. Federal baseboard Model Q.C. 8" 610 B.T.U. - 180 DESCRIPTION OF WORK 15. TO BE DONE: Forced hot water , with baseboard, American Standard boiler , 2 zones 16. HEAT LOSS SCHEDULE. (TO BE INCLUDED FOR ALL JOBS): ROOM SIZE WINDOWS AREA — SQUARE FEET B.T.U. B.T.U. `f DISTRIBUTION INSTALLED AND DOORS VOLUME TOTAL TOTAL w ROOM NO. GROSS GLASS NET WALL CEILING FLOOR CU.FT. AT 70•F CORRECTED J j LL LL REGISTER L W N AND 2 TEMP. TO F F TYPE AND SIZE RAD' OR LEADER SIZE < WALL cT0 (INFILT.I DIFF. •F O m N Sq. FT. FREE AREA 1 13 10 10 018 Lineal f 1 22 166 150 112 i ll 1 21298- Med 1 1 680 12' ' 3 112 4 65 22 143 120 900 10 12 7 8 0 4800 8' ' t 2 2 1920 3' " iv 14 18 7 00 1800210010600 17 ' ' 1,t. 120 2' ' 1 II � n 96 12 7 600 10' " TOTALS I T 95 ' Lineal it. A. HEAT LOSS FROM BUILDING 56480 B.T.U./HR. B. DOMESTIC HOT WATER DEMAND 22500 B.T.U./HR. C. PIPING, OTHER THAN NORMAL 2n nnn B.T.U./HR. ALLOWANCE FOR HEAT VALVE OF FUEL (A B C) FACTOR 17. ELECTRICAL WORK BY: NAME ADDRESS SUBCONTRACTORS AND 18. THEIR TRADES ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE (OWNER) OR (AGENT) OF THIS PROPERTY AND WILL BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE. APPLICATION TO BE COMPLETELY FILLED IN. ; L DATE SIGNATURE OF APPLICANT