Loading...
HomeMy WebLinkAbout125 Bidwell Road (7) FOR OFFICE USE ONLY APPLICATION FOR HVAC PERMIT DATE: JII, tg 4- (NO. ) r, TOWN OF SOUTH WINDSOR EST.COST: 3 p 0 a BLDG. PERMIT NO. 1540 SULLIVAN AVENUE FEE SOUTH WINDSOR, CT 06074 FEES: 644-2511 - Ext. 230 $ 0 - $19000 - $10.00 $1000 or fraction LOCATION OF BUILDING �o�JC' j lD 1oW eL L ?1z AV 0 thereof - $10.00 �-s i CO*ST' S c A-4 42S '� D w E L.L. ZO . 50. w No s o2 OWNER ADDRESS TOWN PHONE NO. 04LOn4iAr A4fL 4j ,,i ¢ )V0A?4wp00 �rI. StOdMf-115- -0 1. Zl3-831'1 HVAC CONTRACTOR ADDRESS TOWN PHONE NO. TYPE OF SYSTEM: HEATING ✓ TYPE OF BUILDING: RESIDENTIAL A/C COMMERCIAL VENTILATION �� BUSINESS INDUSTRIAL IF HEATING: STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR UNIT RADIANT HEATER (INCLUDING WOOD/COAL BURNING STOVE) TYPE OF FUEL: OIL-GPM GAS IN-PUT_ ELECTRIC KW WOOD COAL OIL TANK - SIZE & LOCATION: INSIDE OUTSIDE CAPACITY LPG TANK - CAPACITY EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE_i_OF INSIDE "70 'OF DIFFERENCE��°F 1 Z TOTAL HEAT LOSS (BTUH) /6'00 Q-. (HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE & MODEL NO.): GROSS HEATING CAPACITY (INPUT-BTUH) 3 s JW 0 NET RATING (OUTPUT-BTUH) drO IF AIR CONDITIONING: DESIGN TEMP. OUTSIDEq_°F INSIDE 7 S OF DIFFERENCE 13 F TOTAL HEAT GAIN (BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE & MODEL NO.): IZc o proe (�pw►/b/n�t�!!'T U ' E� A?? C4*iiii ACArJ CI CaTu ) r„ }fin o sold :xe,_sr-�`l- .� r,x' #mA Thy• uOdevisigned hereby #pp�ige for a pesiait,"to" pperf arm the followie,j Work k apc is ;to Ouply with all �localr ordinances And State `of ion J3u#Oiilg Codes in the p®irfvrinlimce of su+ work* DESCRIPTION OF WORK:, �SCv &!tm e4m �I ✓ Y af- S A I 3E — TYPE D TE SIGNATURE, APPLICANT 3K_ AVO APPROVED DATE BD 4A 11/88 I - 8 - R CALCULATION SHEET 1503 (Modern Method) Copyright 1977 by The Hydronics Institute OWNER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATE C L.A COL.S COL.C COL.D COL.E COL.F COL.G 1 ROOM Q O H L W H L W H L W H L W H L W Design Water Temp. 2 ROOM DIMENSIONS,FT. ~ _ U BTUH par F t f 31 LENGTH EXPOSED WALLS,FT. < Radiation Selected 4 WINDOW AND OUTSIDE DOOR AREA IL BTUH BTUH STUN BTUH STUN 5 WALL CONSTRUCTION ROOM LIN.FT.OF (Table 9,Line 3 x H) TOTALS RADIATION 6 TYPE OF GLASS FROM LINE 12 SELECTED (Bottom f table used for L ine 5) 7 CEILING CONSTRUCTION C (Table 9,L x W) — D g FLOOR CONSTRUCTIONt (Table 9, L x W or Lin. F t) E 9 COLD PARTITION CONSTRUCTION F (Table 9,L x H) G 10 _c 1 Wall IWlth Openings) O i 2 Wails(With Op nings) zx ~ 3 Walls(With Openings) or Ent.Hall f. 11 TOTAL BTUH AT 70F TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP. DIFFERENCE K COL.A COLS COL.H COL.1 COL.J COL.K COL.L TOTAL BTUH TOTAL 1 ROOM OF BUILDING RADIATION AT SELECTED O H L W H L W H L W H L W N L W DESIGN TEMP.• 2 ROOM DIMENSIONS, Ft I f- DIFFERENCE 3 LENGTH EXPOSED WALLS, FT. 4 41 WINDOW AND OUTSIDE DOOR AREA U. STUN BTUH BTUH BTUH BTUH 5 WALL CONSTRUCTION •INCREASE BATHROOM (Table 9,Line 3 x H) TOTAL 20% 6 TYPE OF GLASS (Bottom of table used for Line 51 7 CEILING CONSTRUCTION tFOR CONCRETE FLOOR ON GROUND OR FILL AT (Table 9,L x W) GRADE LEVEL,USE LINEAR B FLOOR CONSTRUCTIONt FEET OF EXPOSED EDGE (Table 9,L x W r Lin Ft.) 9 COLD PARTITION CONSTRUCTION (Table 9,L x H) 10 -C 1 Wall(With Openings) C 2 Walls iWith Openings) o X J 3 Walls(With Openings) or Ent.Hall 11 TOTAL BTUH AT 70F TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE FORM 1503 This form is available from The Hydronics Institute,36 Russo Place,Berkeley Heights,N J 07922 _ BUILDING SIZING SUMMARY Bbilding Name : EAST COAST STAIRS 11-07-94 Location : Hartford, Connecticut Block Load Lite v1.00 Prepared By : Engineering Department Page 1 of 1 TABLE 1. INPUT DATA -- WEATHER ----------..-------------------------------------------------------------- City = Hartford Sumpter dry--bulb - 91.0 F State = Connecticut Coincident wet-bulb= 74.0 F Data Source = ASHRAE 1% Daily Range = 22.0 F Latitude 41.7 deg. Winter dry-bulb - 3.0 F Elevation - 15.0 ft Atmos. Clear. Num. = 1.00 _-__---_---___-__----/I ------------III.- W--------------------yam_-----_-______------__---- TABLE 2. INPUT DATA -- BUILDING -------------------------------------------------------------------- System Type Clg & Warm Air Htg THERMOSTAT SETPOINTS System Start 600 Cooling (Occ) 78.0 F Duration 24 hrs Cooling (Unocc) $8.0 F Heating 70.0 F SIZING SPECIFICATIONS FACTORS Supply 57.0 F Coil Bypass 0.050 Ventilation 20.00 CFM/person Safety (Sens) 10 % Exhaust 447 CFM Safety (Latent) 10 % Heating Safety 20 % FAN RETURN AIR PLENUM N Configuration : Draw-Thru Static Pressure : 1.50 in. ---------------- ------------ ------------------------------------- TABLE 3. SIZING DATA -- COOLING ----------------------------- ---------------- Total coil load 172,614 BTU/hr Load occurs @ Aug 1500 Sensible coil load = 144,813 BTU/hr Outdoor Db/Wb = 91.0/ 74.0 F Total sensible - 131,220 BTU/hr Coil Conditions: Supply temperature = 57.0 F Entering Db/Wb = 79.1/ 65.3 F Supply air (actual)= 51789 CFM Leaving Db/Wb = 56.0/ 55.3 F Supply air (std) - 51786 CFM Apparatus dewpoint= 54.8 F Ventilation air = 510 CFM Bypass factor - 0.050 Direct exhaust air = 447 CFM Resulting RH = 48.0 % Reheat required - 0 BTU/hr Floor area (sqft) -- 5,100 Total coil load 14.38 Ton Overall U-value - 0.111 Sensible coil load - 12.07 Ton Vent air CFM/sqft = 0.10 SQFT/Ton M 354.55 Vent air CFM/person = 20.00 Cooling BTU/hr/sgft = 33.85 Cooling CFM/sgft 1.14 ..------------_wrr----__--------____-�-------------------- _--_----_-_--- TABLE 4. SIZING DATA -- HEATING --------------~----------------__-_-_ ------------------------------------ Heating coil load = 150,204 BTU/hr Heating BTU/hr/sgft = 29.45 Ventilation load - 36,884 BTU/hr Heating CFM/sqft = 1.14 Total load = 113,320 BTU/hr Floor area (sgft) - 5,100 V ntilation airflow= 510 CFM Overall U--value - 0.111 Supply airflow 51789 CFM Vent air CFM/sgft - 0.10 Vent air CFM/person = 20.00 ----- ►----__-_---y-_------_- --------- ------------------- i------M .-- DETAILED BUILDING LOAD REPORT Building Name : EAST COAST STAIRS 11-07-94 Location : Hartford, Connecticut Block Load Lite v1.00 Prepared By : Engineering Department Page 1 of 1 TABLE 1. LOAD COMPONENT SUMMARY for Aug 1500 ( 91.0/ 74.0 F) .r___w____-- ------r-------r-----------_------------- Design Cooling Loadsl Design I I { { Sensible Latent 1 Heating I I Load Component J Details I (BTU/hr) (BTU/hr) I (BTU/hr) { ----------------------------r------------------------------------------ Solar Loads I 856 sgftl 52,955 - 1 Wall Transmission I 21344 sgftl 2,128 - I 71852 J Roof Transmission I 3,000 sgftl 70,530 - { 8,040 { ( Glass Transmission 1 856 sgftl 4,138 - { 30,397 1 I Skylight Transmission) 0 sgftl 0 - { 0 1 I Partitions I 21000 sgftl 4,391 - { 21000 1 I Lighting I 1.00 W/sgftl 17,365 - 1 Other Electric ( 1.00 W/sgftl 17,390 { People i 26 people] 6,238 51228 I Infiltration I I 7,157 10,500 1 36,884 1 Miscellaneous I I 0 0 1 - { I Slab { 3,000 sgftl - I - I 9,261 I Pulldown/Warm-up I 1 0 - I Safety Factor I 10/ 10/ 20 % 1 11,929 1,573 1 18,887 I ------------------------------------------------------------------------- I Total Loads 1 1 131,220 17,301 1 113,320 1 ------------------------------------------------------------- ----------- Ventilation Load 1 510 CFMI 71157 10,500 1 36,884 I Supply Fan Load { 51789 CFMJ 61437 - 1 Plenum Load Thru Walll 0 % 1 0 - I Plenum Load Thru Roofl 0 %1 0 - 1 Plenum Load - Lights { 0 % 1 0 - I Reheat Load I I 0 - -----------------_-_ ----------------------------------------_-------------- I Total Coil Loads 1 1 144,813 27,801 1 150,204 1 -----------------------'r'.}------------- -------------_--------_r TABLE 2. WALL AND GLASS BREAKDOWN ---------------------..__..-_---_..--_--_-- �__------------__--_-_-_---_--- I I Total Cooling Cooling Heating I I I Net Area Transmission Solar Load Transmission I Component I (sgft) (BTU/hr) (BTU/hr) (BTU/hr) I ------------------------------------------------------------------------- Walls NE 1 0 0 -- 0 1 I E I 0 0 - 0 1 I SE 1 0 0 - 0 1 I S I 280 543 - 938 I I SW I 0 0 - 0 1 I W 1 1,464 11252 - 41904 I I NW 0 0 - 0 1 I N I 600 333 - 2,010 I ---------w-------~__-__------ -_.i.-r_rr-�d'-------------------w---------- i Glass NE 1 0 0 0 0 1 I E 1 0 0 0 0 1 I SE 1 0 0 0 0 1 I S I 320 11547 12,637 11,363 I I SW 1 0 0 0 0 1 NW f 536 2,5910 40,318 19,033 I I N I 0 0 0 0 1