HomeMy WebLinkAbout151 Berle Road (15) FOR OFFICE USE ONLY APPLICATION FOR HVAC PERMIT DATE: &4v v ,o v 0
(NO. Q ) TOWN OF SOUTH WINDSOR EST.COST: 0.0 e
BLDG. PERMIT NO. 1540 SULLIVAN AVENUE FEE C7&..oo
SOUTH WINDSOR, CT 06074 FEES:
644-2511 - Ext. 230 $ 0 - $19000 - $10.00
$1000 or fraction
-
LOCATION OF BUILDING /,� thereof $10.001 ceGLLe� d ,
OWNER ADDRESS TOWN PHONE NO.
G�� c
HVAC CONTRACTOR ADDRESS TOWN PHONE NO.
TYPE OF SYSTEM: HEATING _ TYPE OF BUILDING: RESIDENTIAL
A/C COMMERCIAL
VENTILATION BUSINESS
INDUSTRIAL
IF HEATING: STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS.
HYDRONIC_ De WARM AIR
UNIT RADIANT HEATER (INCLUDING WOOD/COAL BURNING STOVE)
TYPE OF FUEL: OIL-GPM GAS IN-PUT ELECTRIC KW
WOOD COAL
OIL TANK - SIZE b LOCATION: INSIDE OUTSIDE CAPACITY X'3 3 01Gj
LPG TANK - CAPACITY J
EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION
DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT LOSS (BTUH) (HEAT LOSS SHEET MUST ACCOMPANY APPLICATION)
-DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE & MODEL NO.):
o� L, ►�- j mot- 1 Sl"K,`T-arvtq
�-� ,►2 ��n 7`�
GROSS HEATING CAPACITY (INPUT-BTUH) NET RATING (OUTPUT-BTUH)
IF AIR CONDITIONING: DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT GAIN (BTUH) �
(HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) S� C °�DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE & MODEL NO.):
TONNAGE COOLING CAPACITY (BTUH)
IF VENTILATION: DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN EXHAUSE EQUIPMENT) :
TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM)
(PLAN MUST ACCOMPANY APPLICATION)
The undersigned hereby applies for a permit to perform the following work and is to comply
with all local ordinances and State of Conn. Building Codes in the performance of /such work.
FURTHER DESCRIPTION OF WORK: K S
a La - 130 0" Fi
7o 9L-V 6 SL X&iv--7 06
I 74),Ievaa
STATE LICENSE - NAME & TYPE # DATE SIGNATURE OF APPLICANT
L,1A&dz_, ` -/ -
AP ROVED DATE
I - 8 - R CALCULATION SHEET 1603 (Modern Method) Copyright 1971 by The Hydronlcs Institute
OWNER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATE
COL A COL.S COL.C COL.D COL.E COL.F COL.G
1 ROOM cc
O H L W H L W H L W H L W H L W Design Water Temp.
2 ROOM DIMENSIONS, FT. ~
U OTUH pair Po t 1
3 LENGTH EXPOSED WALLS.FT. A Radiation Selected
4 WINDOW AND OUTSIDE DOOR AREA
STUN STUN BTUH STUN BTUH
5 WALL CONSTRUCTION
ROOM LIN. FT.OF
(Table 9. Line 3 x H) TOTALS RADIATION
6 TYPE OF GLASS FROM LINE 12 SELECTED
10 ttom f table used for Line 51
7 CEILING CONSTRUCTION C
(Table 9.L x W)
g LOOR CONSTRUCTIONt
F
---- - - O—
(Table 9. L x W or Lin. F t) E
9 COLD PARTITION CONSTRUCTION F
(Table 9, L x H)
G
10 c 1 Wall(With OpeningsJ O H
-0
2 Wells(With Openings) :j 1
3 Wells(With Openings)or Ent.Hail �.
11 TOTAL BTUH AT 70F TEMP DIFFERENCE'
12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE K
COL.A COL.0 COL.H COL.1 COL.J COL.K COL.L TOTAL OTUH TOTAL
t ROOM _-- — ---- --z —`---- --i-- OF BUILDING RADIATION
_ _ AT SELECTED
O H L W H L W H L W H L W H L W DESIGN TEMP.*
2 ROOM DIMENSIONS, FT f DIFFERENCE
U -- —
3 LENGTH EXPOSED WALLS. FT
4 WINDOW AND OUTSIDE DOOR AREA #11.
BTUH BTUH BTUH BTUH BTUH
5 WALL CONSTRUCTION •INCREASE BATHROOM
(Table 9. Line 3 x H) TOTAL 20%
6 TYPE OF GLASS
(Bolt m f table used for Line 51
7 - tFOR CONCRETE FLOOR ON
CEILING CONSTRUCTION
GROUND OR FILL AT
(Table 9. L x W) GRADE LEVEL,USE LINEAR
B FLOOR CONSTRUCTION1 FEET OF EXPOSED EDGE
I T able 9.L x W or L in F t l
9 COLD PARTITION CONSTRUCTION
(Table 9, L x H)
10 c 1 Wall(With Openings) O --
=0 --- 3; — — --
2 Wells lWith Openings) o J — --- ----- - ----- - ------ _ —
3 Wells(With Openings)or Ent Hall ►e
11 TOTAL BTUH AT 7OF TEMP DIFFERENCE'
12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE
FORM 1503
This form Is available from The Hydronlcs Institute 35 Russo Place,Berkeley Heights,N J 01922
s
e I-xo
5-,5;7 5-(fn7 <--)4 Pz-e- Ry-,'--7
l WIS NESKI PLUMBING & HEATING
128 TROY ROAD
SOUTH WINDSOR, CT. 06074
860-528-4968
Samsel
BTUH LOSS 17072 GAIN 9956 29 . 69 BASEBOARD FT. @ 575 BTU FT
/ @ 180 F.
ROOM NUMBER 1 2
ROOM NAn
Re c Bathf 2 0$ 3 4
7 .00 7 .00
LENGTH 37 .00 S. 00
WIDTH 26 . 00 7 .00
EXPOSED WALL LENGTH
# WALLS WITH OPENINGS 2 1
EXPOSED GLASS AREA 46 .50 20 .25
L INFILTRATION . 018 7515 . 018 437
0 CEILING . 07 4175 . 07 243
S FLOOR SQ FT
S SLAB LINEAR FT
E COLD PARTITION
S .WALL
GLASS 1 . 13 3258 1 . 13 1419
TOTAL LOSS @ 6-2 DTD 14699
83
BASEBOARD FEET @ 180 25 .5 23 41.
GAIN
8428 1529
ROOM NUMBER 5 6
ROOM NAME 7 8
HEIGHT
LENGTH
WIDTH
EXPOSED WALL LENGTH
# WALLS WITH OPENINGS
EXPOSED GLASS AREA
L INFILTRATION
0 CEILING
S FLOOR SQ FT
S SLAB LINEAR FT
E CO-La PARTITION
S WALL
GLASS
TOTAL LOSS @ 62 DTD
BASEBOARD FEET @ 1S4
GAIN