Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
100 Collins Crossing
Electric# I 64(g11�5L APPLICATION FOR BUILDING PEROT Plumbing Q 100 COLLINS CROSSING HVAC # S +F* Date: r 9 Sprinkler# No. 2 5 5 7 0 FSW APPlot V Estimated Cost $ y, 00 0 Building Z COMPLETE RED BOXED AREAS Permit Fee Engineering S 9 TYPE OR PRINT ONLY Occupancy Fee $ Affidavit 9124,117 SIGN ON REVERSE S®E Appr.for CO. 'q9 Total Fee $ 1*1 '•S 3 TO BUILDING DEPARTMENT,TOWN OF SOUTH Mnl%, R,CT G4dditional Costs The undersigned hereby applies to do work accorilng to the following speehica kxw Job Location 1 D O CT O t L I NS C&QS 1/V 6 Lot No. 1 Side of Street Zone IQ R Applicant elt-M FFtJ T-F.0 JOC(SF S s/E/C _ -Tel# 49 V41—Sa M Addr ss f:kniC 10 C�a Zip 660 Lic.# Own r (2)R 1 A n1 V*6W Aj?l�S Address Architect VAo M t `W_S 6 rJ Address f 9V WINDSoe Ad E W(Mbloe c? 0609S' Sq.Ft.New Area: 1st Fl. t ('D OO 2nd Fl. 70 5" 3rd Fl. Total New Area 3 O S #Rooms 9 #Lavatories #Bathrooms 3 #Garages CP1. Purpose of this permit. g i,N 6 L e 64m j%�Y *t>W'Z L L 1 W G City Water V Well 0 Septic System ❑ Sewer Ins. H.O. S.P. Cent. Area Z rJ Basement Garage 5 Approved by Date Use Group Construction Type Revbed 1197 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in which this building and' use' allowed. M Signed I hereby apply for a Certificate of Occu ancy for the work in this plication for the permit. Signed DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS Location of job AFFIDAVIT Additional Fee —0— State of Connecticut SS. County of Hartford 1 ( �R�S of )�'�o,\ for building erected under Contractor Permit No. 25570 issued by the Dept of Building of the 7bwn of South Windsor being duly sworn.make oath and say that the actual cost of the completed work authorized under said permit was $164,700.00. • .• •. Signed . . . . ..... .. . Subscribed and sworn to before me this . . ... ... .... .. .day of A.D.19 . !. . EsOmate Cost:$ 164,700.00 .. ........ L'.�'. Difference: i —0_ Notary Public Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------------------- 98-25570-B 144,000 B01 FOOTING 09/17/98 JFF A B02 FOUNDATION 09/29/98 JFF A P02 UNDERGROUND 11/12/98 DCJ A B05 FIREPLACE/CHIMNEY 02/19/99 DCJ A B03 FRAMING (ROUGH) 03/03/99 JFF D NEED MICRO SPECS TRADES NOT STARTED ADVISED DAVE NEED SPECS E03 ROUGH 03/16/99 JFF D NOT STARTED NOTIFIED BRIAN NEED ELECT PERNIT E01 SERVICE 03/23/99 DCJ A RELEASED TO N.U. B03 FRAMING (ROUGH) 06/25/99 RAN A E03 ROUGH 06/25/99 RAN A SWITCH BOXES IN BEDROOMS NOT YET INSTALLED P03 ROUGH 06/25/99 RAN A B04 INSULATION 07/01/99 DCJ A B10 FINAL 08/19/99 DCJ D ADD RECEPT. IN KITCHEN, WORKING BATH, SCUTTLE IN GARAGE 5/8" TYPE X,RAILING IN FRNT, CHIMNE B10 FINAL 08/20/99 RAN D CLEANOUT DOOR NOT SECURE; CHECK REAR DECK RAILINGS B10 FINAL 08/24/99 DCJ A APPROVED FOR CO (BLDG) 99-10381-H 8,700 98-10265-P 8,000 99-16165-E 4,000 Total Est Value 164,700 Dwelling 2,259 92,438.28 Basement 1,375 17,050.00 Garage 576 7,142.40 Smoke Det 7 525.00 BOCA Value 132,385.92 Difference (32,314.08) 4'cc ,► �,,�,. SITE COMPLIANCE CHECKLIST TOWN of SOUTH WINDSOR, CONNECTICUT 100 COLLINS CROSSING LOT_# I � Reviewed B (En ineering) B & M ENTERPRISES Date Reviewedgft pro /Denied 376 PLEASANT VALLEY RD,SOUTH WINDSOR,C Reviewed By 40,V (Planning) BP_#_25570_ Ph_# (203)528-5418 Date Reviewe Approv denied Date Submitted 08/24/99 ***** FOR C of 0 ** r Y rr Ce/ rA' As required in the Zoning and/or Subdivison Regulations, no Certificate of Occupancy shall be issued until grading plans have been complied with and approved by the Town Engineer. The minimum requirements shall include: Approved Denied N/A 1. Approved building permit plan 2. Finish grading per approved building permit plan 3. Site work; i.e. trees, shrubs, dumpsters, required parking 4. Utility location; a. sanitary sewer/septic system/ b. foundation drain c. electrical & telephone d. water e. other G 5. Sewer connection charge paid 5�1�r15s� 6. Appropriate certification 7. Bonding 8. Planning & Zoning/ Inland Wetlands Considerations Sewer Permit No. mv Pavement Excavation No. COMMENTS: J ri.s.. i., �cirredpdl:-Vogl fib♦�is�•. 12 00,or „��/ ` fa r J s C/i�.✓c �.0. M aN 1999 < , 44 SITE COMPLIANCE CHECKLIST TOWN of SOUTH WINDSOR, CONNECTICUT r;'Aa- 100 COLLINS CROSSING LOT_# Lr Reviewed By Y ( �*!rer' B & M ENTERPRISES Date Reviewed r D 376 PLEASANT VALLEY RD,SOUTH WINDSOR,C Reviewed By la ng) BP_#_25570_ Ph_#_(203)528-5418 Date Review /� 9 r /Denied Date Submitted 09/09/98 ***** F BUILD NG PERMIT ***** �ArNV.t A /� �d In accordance with the Zoning nd/or Subdivision Regulations, prior to the building of any structure on a lot, a Topographic Plot Plan shall be submitted for approval. The minimum requirements shall include: Approved Denied N/A 1. Name, address & phone number of owner/applicant ✓ 2. Name, address & phone number of plan preparer 3. Zoning Information - i.e. zone, open space, floodway, etc. 4. Plot Plan at 1" = 40' scale / a. Subdivision reference, abutting properties, etc b. Easements of record _ c. Lot description, bearings, building lines, distances, area, etc. d. Contours, existing & proposed, 1 or 2 ft. interval where appropriate e. Building location with dimensions. Elevations of proposed finish floor, garage floor & centerline of road at driveway f. Elevations of gravity drainage systems, sanitary & foundation drain at the house and the street g. Tentative utility location (gas, water, electric, septic system, etc.) h. Title block with name and address of preparer, date, appropriate certification, live seal and live signature consistent with the Board of Registration requirements. (P.E. & L.S.)jA- 5. Sedimentation and erosion control 6. Special Planning & Zoning, Inland/Wetlands considerations (Plans on file w/Town Clerk) COMMENTS: 1 a4 19 DEPARTMENT DECISION PERNUr# APPLICATION FOR ELECTRICAL PERMIT Application is hereby DEPARTMENT;R TOWN of SOUTH WINDSOR P App BUILDING DEPARTMENT Bldg Permit# APPROVED 1540 SULLIVAN AVENUE 644-2511 ext.230 f �j Date Building Inspector Application must be printed or typed Location of job �—� 1 Street No. Street Lot No. FEE SCHEDULE Floor Apt.No. $0 - $1,000 - $12.00 Over $1,000 $12.00 per$1,000 OWNER or any fraction thereof ADDRESS OWNERS PHONE# APPLICANT '—/-D 0* ADDRESS ff s— < tjj ESTIMATED COST$ IS THIS A CONTRACT COST? YES NO Aw FEE ENCLOSED $ �SOR-CO lem O�TE OF JOB: l Original Installation Alteration/Addition Repair Revised 11/95 APPLICATION FOR ELECTRICAL PERMIT(Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A RESIDENTIAL BUILDING PERMIT APPLICATION YES / NO BUSINESS ASSEMBLY CURRENT USE AND OCCUPANCY MERCANTILE EDUCATIONAL FUTURE USE AND OCCUPANCY INSTITUTIONAL FACTORY STORAGE ENGINEER'S NAME PHONE GARAGE MIXED USE ADDRESS CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION/WIRING METHOD SIZE OF MAIN FEEDERS AND RATING OF WIRE USED NUMBER OF METERS NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS REMOTE DISCONNECT REQUIRED?YES/NO NUMBER OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPERATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONN.BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. /�3 � =� NAME STATE LICENSE NO. TYPE SIGNATURE OF APPLICANT PHONE NO. - ���� DATE 8' / / I INSPECTOR ��-�—� DATE--' TIME �m LOCATION r7 �b I ) :�rl INSPECTION: CODE: RESULT(D A) : z.s-7 t `t 7 BUILDING: 7/ J ` cow Loy"� ELECTRICAL: l� l (0 jo-�•� 6.. PLUMBING: HVAC: OTHER: DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT P Application is hereby: TOWN of SOUTH WINDSOR BUILDING DEPARTMENT Bldg Permit# X045;6eAPPROVED 1540 SULLIVAN AVENUE 644-2511 ext. 230 Date Building Inspector Application must be printed or typed Location of job 100 Collins Crossing Street No. Street Lot No. FEE SCHEDULE Floor Apt.No. $0 - $1,000 - $12.00 Over $1,000 OMMEA $12.00 per$1,000 OWNER B & M Enterprises or any fraction thereof ADDRESS P.O. Box 1060 South Windsor, CT. 06074 OWNERS PHONE# 6 4 4-3 5 7 2 APPLICANT David W. Hany, Hany Brothers, Inc . OW N ADDRESS 170 West Main St. Rockville, CT. 06066 C� ESTIMATED COST$ P oc > . as p C IS THIS A CONTRACT COST? x YES NO - `' �C.► FEE ENCLOSED $ OR-CO TYPE OF JOB: X Original Installation Alteration/Addition/Repair Revised 10/96 APPLICATION FOR PLUMBING PERMIT(Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION YES / NO X RESIDENTIAL BUSINESS CURRENT USE AND OCCUPANCY new construction ASSEMBLY MERCANTILE FUTURE USE AND OCCUPANCY single family EDUCATIONAL INSTITUTION FACTORY ENGINEER'S NAME PHONE STORAGE GARAGE ADDRESS MIXED USE CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION all plumbing SIZE OF MAIN DRAIN 411 NO. OF TOILETS 3 STYLE No.OF URINALS STYLE NO.OF BATHTUBS 1 NO.OF SHOWERS 2 NO.OF LAVATORIES 3 NO.OF CONDUCTORS SIZE NO.OF STACKS 2 SIZE 3 if & 1 2 AREA OF ROOF NO.OF CATCH BASINS NO.OF FLOOR DRAINS NO.OF OTHER FIXTURES 1 KIND Whirlpool ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW YES/NO SIZE OF WINDOW 2 x 3 IF NONE C.F.M.OF VENTILATOR SIZE OF DUCTS SEWER OR SEPTIC TANK Sewer SIZE OF WATER MAIN 1 SIZE OF WATER PIPING&RISER 3/4" & 1/2" WATER HEATER TYPE G a s MANUFACTURE A. 0. Smith TANKS SAFETY DEVICES TEMPERATURE CAPACITY 40 gal . RELIEF VALVE TEST PRESSURE 3 5 0 WORKING PRESSURE 15 0 PRESSURE RELIEF VALVE TYPE 10 0 X L MANUFACTURER Watts DESCRIPTION OF WORK all plumbing for new residence THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE W DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF COI B DING DES PERFORMANCE OF SUCH WORK. , NAME STA LICENSE NO. TYPE IGNATURE OF APPLIC PHONE NO. e 7 Z y?OL DATE /0Z 2 Z1-v- DEPARTMENT DECISION PERNUT:9 APPLICATION FOR HVAC PERMIT Application is hereby TOWN of SOUTH WINDSOR BUILDING DEPARTMENT Bldg Permit# APPRO 1540 SULLIVAN AVENUE 644-2511 ext. 230 Date Building Inspector Application must be printed or typed Location of job '..')re 4 /to 0 CO J6!�. Street No. Street %.0; Lot No. FEE SCHEDULE F, $0 - $1,000 - $12.00 Floor Apt. No. Over $1,000 FStreet)) Floor $12.00 per$1,000 4e- r je f-e or any fraction thereof OWNER j6 V--IX mil 7 r 4e. ADDRESSA, k /,0 ZD e,160 7eK OWNERS PHONE '400� APPLICANT OW N ADDRESS_Z0 1'eflv df--� At 4 -7 61000" ESTIMATED COST IS THIS A CONTRACT COST? YES NO FEE ENCLOSED $ SORO CQ XE OF JOB: inal Installation Alteration/Addition Repair Revised 11/95 APPLICATION FOR HVAC PERMIT(Continued from rcvcrsc side) TYPE OF SYSTEM YPE OF BUILDING HEATING � RESIDENTIAL 41-� A/C COMMERCIAL VENTILATION INDUSTRIAL HEATING STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR�� UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE © F INSIDES DIFFERENCE_Z TOTAL HEAT LOSS(BTUH){3 y6 70 (HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY (INPUT-BTUH) NET RATING (OUTPUT-BTUH)�,50 0 TYPE OF FUEL OIL-GPM�� GAS-INPUT ELECTRIC-KW OIL TANK SIZE&LOCATION BY INSIDE OUTSIDE CAPACITY LPG TANK CAPACITY AIR CONDITIONING GG DESIGN TEMP. OUTSIDE/� F INSIDE7D F DIFFERENCEZ(DF TOTAL HEAT GAIN(BTUH) yo 6 06 (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE&MODEL NO.) 000, TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK O tklo, .0 1—e t Q csu- i THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONN.BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. S` - 2., J,5� STATE LICENSE-NO.NAME&TYPE SIGNAIURE F APPLICANT PHONE N0�O 'O J DATE ll ADVANCED HEATING & AIR CONDITIONING Inc. JOB NAME: B&M Enterprises So, Windsor DESIGN CONDITIONS TOTAL BLDG. HEAT LOSS/GAIN PHONE 644-5288 P.O. Box 1060 CT. -------------------------- -------------------------- BLDG : Lot #11 Heating: 75 deg f.t/d BLDG Heat Loss BTU 34,670 Estimator: NOTES: 100 Collins Crossing Cooling: 20 deg f.t/d BLDG A/C Gain BTU 40,606 Stephen Smith Room 1 Room 2 Room 3 Room 4 Room 5 Room 6 Room 7 Room 8 Room 9 Room 10 Room 11 Room 12 AREA NAME; Family Living Foyer Dining Hall Bed 14 Kit Dinnette Master Bed 11 Bed 12 Outside Wall Length; 29.0 26.0 11.0 15.0 26,0 57.0 12.0 11.0 57.0 28.0 30.0 0.0 Outside Wall Height; 9.0 9.0 19.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0 8.0 Sq/Ft S or W Glass ; 24,0 0.0 0.0 0.0 0.0 36.0 9.0 50.0 20.0 34.0 0.0 0.0 Sq/Ft N or E Glass ; 0.0 36.0 30.0 24.0 6.0 0.0 0.0 0.0 36.0 0.0 24.0 0.0 No of Doors ; 0.0 0.0 1.0 0.0 2.0 0.0 0.0 0.0 0.0 1,0 0.0 0.0 Floor Width ; 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Floor Length ; 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Roof Width ; 0.0 0.0 11.0 0.0 7.0 11.0 0.0 2.0 16.0 20.0 17.0 0.0 Roof Length ; 0.0 0.0 17.0 0.0 23.0 23.0 0.0 11.0 25.0 8.0 13.0 0.0 -------------------- -------- -------- -------- -------- -------- -------- -------- -------- -------- -------- -------- -------- Area Cubic Feet 0 0 3,553 0 1,449 2,277 0 198 3,600 1,440 1,989 0 Gross Wall sq/ft 261 234 209 135 234 513 108 99 513 252 270 0 Net Wall sq/ft 237 198 ISO 111 186 477 99 49 457 197 246 0 Wall Heating BTU 711 594 474 333 558 1,431 297 147 1,371 591 738 0 Wall Cooling BTU 379 317 253 178 298 763 158 78 731 315 394 0 S/W Glass sq/ft 24 0 0 0 0 36 9 50 20 34 0 0 S/W Glass Heating BTU 1,116 0 0 0 0 1,674 419 2,325 930 1,581 0 0 S/W Glass Cooling BTU 298 0 0 0 0 446 112 620 248 422 0 0 S/W Glass Solar BTU 1,728 0 0 0 0 2,592 648 3,600 1,440 2,448 0 0 N/E Glass sq/ft 0 36 30 24 6 0 0 0 36 0 24 0 N/E Glass Heating BTU 0 1,674 1,395 1,116 279 0 0 0 1,674 0 1,116 0 N/E Glass Cooling BTU 0 446 372 298 74 0 0 0 446 0 298 0 N/E Glass Solar BTU 0 1,296 1,080 864 216 0 0 0 1,296 0 864 0 Doors sq/ft 0 0 21 0 42 0 0 0 0 21 0 0 Door Heating BTU 0 0 504 0 1,008 0 0 0 0 504 0 0 Door Cooling BTU 0 0 168 0 336 0 0 0 0 168 0 0 Floor sq/ft 0 0 187 0 161 253 0 22 400 160 221 0 Floor Heating BTU 0 0 0 0 0 0 0 0 0 0 0 0 Floor Cooling BTU 0 0 0 0 0 0 0 0 0 0 0 0 Roof sq/ft 0 0 187 0 161 253 0 22 400 160 221 0 Roof Heating BTU 0 0 421 0 362 569 0 50 900 360 497 0 Roof Cooling BTU 0 0 187 0 161 253 0 22 400 160 221 0 Lights Cooling BTU 0 0 160 0 137 216 0 19 341 137 189 0 Appliance Cooling BTU 0 0 196 0 169 266 0 23 420 168 232 0 People Cooling BTU 0 0 120 0 103 162 0 14 256 103 142 0 Latent Cooling BTU 0 0 107 0 92 144 0 13 228 91 126 0 Ventilation Heat BTU 329 408 503 261 397 661 129 454 878 546 423 0 Ventilation Cool BTU 433 371 476 241 286 872 165 790 1,045 722 444 0 Duct Heat Loss BTU 129 161 198 103 156 260 51 179 345 215 166 0 Duct Cool Loss BTU 170 146 187 95 112 343 65 311 411 284 174 0 --------------------- ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ Area Heating BTU 2,285 2,837 3,494 1,812 2,761 4,596 895 3,154 6,098 3,797 2,941 0 Area Cooling BTU 3,008 2,576 3,305 1,675 1,984 6,057 1,148 5,490 7,264 5,017 3,082 0 Area Air Heating CFM 30 37 46 24 36 60 12 41 60 50 39 0 Area Air Cooling CFM 100 86 110 56 66 202 38 183 242 167 103 0 TTL Building, Square feet-> 1,404 - Heating--Air Changes/Hour -> 1.89 TTL Building. Cubic feet-> 14,506 Cooling Air Changes/Hour -> 5.60 --------------------------- ------ --------------------------- ----- TTL Building Heating CFM -> 456 Heating CFM per SQ/FT -> 0.32 TTL Building Cooling CFM -> 1,354 Cooling CFM per SQ/FT -> 0.96 01/09/99 HEATING/COOLING BTU ESTIMATE