HomeMy WebLinkAbout19 Charlie Circle nn 40
11
TO THE BUIULDING INSPECTOR
of the APPLICATION FOR
TOWN OFSOUM WUM-SA R,C"!i PLAN EXAMINATION AND
BUILDING PERMIT
IMPORTANT — Applicant to complete all items in sections: 1, 11, /it, IV, and IX. z
0
�• AT (LOCATION) 10 � l D ZONING
LOCATION IKo•) (STREET) DISTRICT
i—I
OF BETWEEN AND
BUILDING (CROSS STREET) (CROSS S MA
T)
SUBDIVISION LOT BLocK SIZE
II. TYPE AND COST OF BUILDING — All app scants complete Parts A — D
A. TYPE OF IAPROVEMENT
D. PROPOSED USE — For"Wrecking"most recent use m
m
1 eNew building Res-iAe-gsial N
onresidential
2 ❑ Addition(l/residential, enter number 12 One family 18❑o/new housing units added, if any, Amusement,recreational
in Part D. 13) 13❑ Two or more family — Enter 19❑ Church, other religi us
3 ❑ Alteration (See 2 above) number o/units—— — —-.0',_,__ 20❑ Industrial
14 ❑ Transient hotel,motel, 21 ❑ g garage
e
4 El Repair, replacement or dormitory _ Enter number g
5❑ Wrecking (It multifamily residential, o/units ——————— —..i 22 ❑ Service station, repair garage
enter number o/units in building in 15 ❑ Garage 23❑ Hospital, institutional
Part D, 13)
16 ❑ Carport 24❑ Office, bank, professional
6 El Moving (relocation)
17❑ Other — Speci/y 25❑ Public utility
7 ❑ Foundation only
26❑ School, library, other educati nal
B. OWN RSHIP 27❑ Stores, mercantile
8 OWN
(individual corporation,
p on, 28 ❑ Tanks, towers
n nprofit institution, etc.) 29❑ Other -, Specify
9 ❑ Public(Federal, State, or
local government)
C. COST (Omit cents) Nonresidential — Describe in detail proposed use of buildings, e.g., food
processing plant, machine shop, laundry building at hospital,elementary
10. Cost of improvement,,,,,,,,,,,,,,,, gQQ school, secondary school, college, parochial school, parking garage for,
department store, rental office building, office building at industrial plant.
To be installed but not included If use of existing building is bein chap ed enter
in the above cost g g proposed use.
a. Electrical......................
b. Plumbing ......................
c.Heating, air conditioning.........
d. Other(el vator, etc.)............
11. TOTAL COST OF IMPROVEMENT $ S 0O—
III. SELECTED CHARACTERISTICS OF BUILDING --For new buildings and additions, complete Ports E — L;
for wrecking, complete only Part J, for all others skip to 1V.
E. PRINCIPAL TYPE OF FRAME G. TYPE OF SEWAGE DISPOSAL J. DIMENSIONS
30 asonry(wall bearing) 40 P�Public or private company 48• Number of stories................
31 Wood frame 41 ❑ Private (septic tank, etc.) 49. Total square feet of floor area,
32❑ Structural steel all floors, based on exterior 9
33 Reinf reed concrete H. TYPE OF WATER SUPPLY dimensions .....................
34❑ Other — Speci/y 42 Ej3Avu0"b'lic or private company 50. Total land area, sq. ft. ........... .=70 -71 1
43❑ Private(well, cistern) K. NUMBER OF OFF-STREET
PARKING SPACES
F. PRINC�PAL TYPE OF HEATING FUEL I. TYPE OF MECHANICAL 51• Enclosed .......................
35 Gas Will there be central air 52. Outdoors........................
36❑ Oil c nditioning?
37❑ Electricity L. RESIDENTIAL BUILDINGS ONLY
44❑ Yes 45 N 39 Coe)
53. Numb r f bedrooms..............
❑
39❑ Other— Specify Will there be on 1 vator? �.
54. Number of Full..........
46❑ Y s 47o bathrooms
17. IDENTIFICATION - To b compl ted by all applicants
Name Mailing addr ss — Number, street, city, and State ZIP code Tel. No.
�• Clark Realty Inc., 658 Ellington,zRoad,
Owner or
Lessee South Windsor, Ct. 06074 82-0628
2. Same Same
Contractor
3.
Architect or
Engineer
The owner of this building and the undersigned agree to conform to all applicable laws of this jurisdiction.
Signature of applicant Address Application d to
00 NOT WRITE BELOW THIS LINE
V. PLAN REVIEW RECORD - For office use
Plans Review Required Check Plan Review Date Plans By Date Plans By Notes
Fee Started Approved
BUILDING $
PLUMBING $
MECHANICAL $
ELECTRICAL $
OTHER $
VI. ADDITIONAL PERMITS REQUIRED OR OTHER JURISDICTION APPROVALS
Permit or Approval Check Ob Date
to ned Number By Permit or Approval Check ObDtoined Number By
BOILER PLUMBING
CURB OR SIDEWALK CUT ROOFING
ELEVATOR SEWER
ELECTRICAL SIGN OR BILLBOARD
FURNACE STREET GRADES
GRADING USE OF PUBLIC AREAS
OIL BURNER WRECKING
OTHER OTHER
VII. VALIDATION
Building
Permit number
Building
Permit issued �,L/;1 19
Building
Permit Fee $H� '
cro
-U TITLE
TOWN OF SOUTH WINDSOR
BUILDING PERMIT
Date June 17 19 86
Fee Paid $. .4 0 8.0 0 Eat. Value $.6.8.,.0 0 0
Permit N° 1516 8
on the aide of
Lot #49 Charlie Circle Street
Street No. 19
Owner rl ark Rpa 1 ty Tnr
Applicant M??-r?e 1 .Ta c qu e s
CERTIFICATE OF OCCUPANCY ISSUED:
Date
No.7 6 A 4
Fee Paid $ -2 a o
CLASSIFICATION
Dwelling
BUn DING PERMIT
N'' 15168
OFFICE OF
THE BUILDING INSPECTOR
of the
Town of South Windsor, Conn.
South Windsor, Conn. jMe ]T— 1986
ar#io 'to to (ferf tfu, That ClArlc R&AI ty inre__
is hereby granted permission to Dwelling
at estimated value of
C—
on the side of h=rlea;i=IQ Street on land
owned by
Said wank to be as described in Application
No. 16468 and to conform to specifications and plans filed with said Application, and Building By.
Laws of THE TOWN OF SOUTH WINDSOR.
Issued '17 1986
F I?f
J P
Building Inspector.
Streets and sidewalks, obstructed by excavations or building materiaL4 must be guarded by barriers
during the day and by both barriers and colored lights by night.
SECTION 1343, GENERAL STATUTES OF CONNECTICUT: "When any person shall place
or keep building materials, or any obstacle in any highway (or any sidewalk) either with or without a
license therefor from the city or borough in which such highway may be situated, he shall pay said city,
town or borough all costa and damages which it shall sustain, or be compelled to reason therefor."
INSPECTION REPORT
Permit # I'a 3a 7 Job C ,
1 Footinn' i/a
2 FoundatioN` _2
3 FramiAb<j / -�T C
4 Wiring —,U-a 7P
5 Plumbing
6 Heating jel b6
7 Lathing
8 C.O.
Dwelling - Lot #49 Pl.Val.2 6/17/86
Clark Realty Inc.
19 Charlie Circle Permit # 15168
Electrician #
Heating Contr. So.Windsor P/H # 6467
Plumbing " So.Windsor P & H #7029
Oil Burner #
Certificate of Occupancy # 7640
Sewer Permit
Plot plans appr . per Engr.
I
1
Permit No. TOWN OF SOUTH WINDSOR
SOUTH WINDSOR, CONN.
Permit Q 7640
Certificate of Occupancy
THI V CERTIF thatithe Pf
at No. in th own of South Windsor, Connecticut, has
been erected and.completed in accordance withjhBLd Code and Zoning Regulations of
the Town of South Windsor, and is hereby appupancy.
Building Inspector
O ner, Build
I Fee Paid Date C2 't 1986
s-49
REINO E. MYYPPA a ASSOCIATES
CIVIL. ENGINEERS a LAND SURVEYORS
GLAS TON8MY, CONN.
- >50
12q,?
��J
G�B•�2.I g �k
0 R=so
' 3 so
IN,
T _ VIP
"r y P
D3.
U)
a
LL
7E (%j
�• 1
75
(V--
uj
�-- REA=
\�
\, 2�,`71 f � \
U-- { , S.F\
3�Z81 gg
80
t 5 F � CQfi �qc 92
Lar l_ NF ROM 0AP oM F LE TtTLF-0, 7o c 4
��
''cEu 5PAtE 5U0VNt540N A-W ZO P4�� 1v� " ; cod
PUW PLAW SE,c ON ?- PLEASA)vr S h s Fc�, 5 rRv
VAU..Ey HC*AeS II Soy rt-H WtN05CW.
C.NlG' l•� �t.,�►.tQ gUQvEvoRS
Y. N. Scim 0=4V PREPAREO Fop
SHMt -S of 12 5%zlei .Rcvc -10-08 PLEASANT VALLEY HOMES II
.�.ecac�o A•� w v-ti4 e�, SOU 7 H W I N D SO R.I G O NN.
tJo 2Dt+#t�,r, Vtati.AT i o+�g
GrER'CI FI E D 5ue5TAJI' t A-LLY RRECT 1°-40' DATE.: Z.-3-S CO
�0
�+.�.,•, d..2�,.tit., Oar,,�,a�,cMn.n�,,
Ov ^^s`' �\ie`a
fl
ZP
-40
Oce�it
+fir
CIS
Ocle Ot
Olt'
at
Woe
04 t Ad'oe
low
.%Vfte6
pt
7029
PLUMBING APPUCATION
Application Na. (;R n n
on the ... aide of
_.....Lat... .._Charlie Circle S9
Street No. ._._._.__ 19
()wner .. .Clark Realty Inc .
plumber So. Windsor Plbq. & Htq.
Filed in Office of
The Bnl&mg Impactor
6/19/86 19
II�SP�C�Olf.
No person shall coeatuM add m or alder ate
portion of the drainage symm of amp boa&og
(c=pt to repair lake) until a Pimmic is spum d
by the Building Lwpamw.
APPLICATION FOR PLUMBING PERMIT (Continued from Reverse Side)
TOWN OF SOUTH WINDSOR, CONN.
11. LOCATION OF JOB Lot #49 Charlie Circle
NO. STREET FLOOR APT.NO.
GENERAL PLUMBING
12. KIND OF INSTALLATION Residential 13. SIZE OF MAIN DRAIN 4
14. NO. OF TOILETS 3 STYLE tank type 15. NO. OF URINALS 0 STYLE
16. NO.OF BATHTUBS 1 17.NO.OF LAVATORIES 3 18. NO.OF SINKS�_ 19. NO. OF WASHTUBS 0
20. NO.OF CONDUCTORS SIZE 21. NO. OF STACKS I SIZE }"
22. AREA OF ROOF 23.NO. OF CATCH BASINS 24. NO. OF FLOOR DRAINS
25. NO. OF OTHER FIXTURES ane KIND 3' £ih�A 1 aSa choUler
26. ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW? 27. SIZE OF WINDOW
28. IF NO WINDOW, WHAT KIND OF VENTILATION IS THERE? e1 Ar t-ri r gent fan
29. SIZE OF DUCTS 30. ARE SEWAGE AND WATER FACILITIES AVAILABLE? yes
SIGNATURE ADDRESS 524 Burnham Street South Windsor 06074
LICENSE NO. 901062 ESTIMATED COST TELEPHONE rgs-Agj 2
OWNER Clark RP1 aty T33c-, ADDRESS 658E1-ling.o-Raa--Seth Windsor- 06n74
WATER HEATER
31. TYPE gas fired 32. MANUFACTURER A O_ Smith
TANK SAFETY DEVICES
33. CAPACITY
40 gallons 37. TEMPERATURE RELIEF VALVE
34. TEST PRESSURE_ II o' /�S 38. MANUFACTURER_
35. WORKING PRESSURE 6/ �J l 39. PRESSURE RELIEF VALVE
36. TYPE zo,/,J /i k c, G� 40. MANUFACTURER
ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE OWNER OF THIS PROPERTY
AND WILL BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE.
L7
CD962 DATE SIG14ATURE AP ICANT /
PERMIT #
Application For 6 26 5 6467
DEPARTMENT DECISION
0) 0 Heating Permit
3 E APPLICATION IS HEREBY: DEPARTMENT OF LICENSES AND INSPECTIONS
tq APPROVED ❑ DISAPPROVED
.� Cd TOWN OF SOUTH WINDSOR
0 � Thcm-a. P. D' Auri-a
DATE CHIEF INSPECTOR APPLICATIONS MUST BE PRINTED OR TYPED. BEGIN WITH NUMBER ONE BEL W
O
p y 1. LOCATION OF JOB
0
0
19 Charlie Circle
NO. STREET
4-3
Cd
49
O LOT NO. FLOOR APT. NO.
O o
O
t. OWNER Clark Realty Inc
� o
b 3 b0 S. ADDRESS 658 F1 1 i naton Road
_ Snuth Wi ndsor a.PHONE 2 82-062 8
Cc
s. APPLICANT South Windsor Pluming
eri �
'^ 0
'O a. ADDRESS 524 Burnham Street
_
cc
� O
w South Windsor 7.PHONE 528-4413
+' S. LICENSE NO. 307190
a
p w s. EXPIRATION DATE OF LICENSE 10/1/87
c�
� pG 10. ESTIMATED COST S- l 21o.:J J�
aq `y
r= bo 11. IS THIS A CONTRACT COST? YES ❑ no
it. FEE ENCLOSED =- r e m it 1 51 F 8
k
IS. TYPE OF BUILDING:
v� ❑
O R
RESIDENTIAL COMMERCIAL
�cis14. TYPE OF JOB: ElINDUSTRIAL
3
ORIGINAL ❑ ALTERATION
INSTALLATION ADDITION
REPAIR
APPLICATION FOR HEATING PERMIT (Continu d it m R v roe Side)
11. LOCATION OF JOB Lot #49 Charlie Circle
NO. STREET FL OR APT.NO.
12. TYPE OF INSTALLATION: ❑ OIL BURNER ❑ ELECTRIC ❑ VENTILATION ❑ SPRINKLER
GAS BURNER ❑ STACK ❑ INCINERATOR ❑ MISCELLANEOUS
IDENTIFY
SIZE LOCATION SIZE SIZE
13. OF TANK OF TANK OF FILL OF VENT
14. B.T.U. EQUIP. AT REGISTER FURNACE MAKE AND NO. AT BONNET FIRING RATE
BOILER OR FURNACE MAKE AND NO. tlTbC&—B.T.U. OR SQ. FT. NET 4101' B.T.U. OR SQ. FT. GROSS FIRING RATE
FLOORS TO BE HEATED TLUi) NEW OR OLD BUILDING &-AE ✓ INSULATED — YES OR NO
TYPE OF WALL U1910il INSULATION J�Ql—Vt rf ROOF OR CEILING INSULATION
AVG. SYSTEM WATER TEMP. B.T.U./SQ. FT./HR. EMISSION
INDOOR-OUTDOOR TEMPERATURE DIFFERENCE Q —NO`� °FAHRENHEIT
MAKE OF RADIATIO BASEBOARD COPPER�ONVECTORS, OR C.I. RADIATION. OUTPUT PER SECTION OR LINEAL OF RADIATION. SQ.
FT. OR B.T.U. �n/�•eti-� -
DESCRIPTION OF WORK e
15. TO BE DONE:
Is. HEAT LOSS SCHEDULE. (TO BE INCLUDED FOR ALL JOBS).
wlNDows AREA - SQUARE FEET S.T.U. S.T.U. F O
AND DOORS VOLUME t F DISTRIBUTION INSTALLED
ROOM slzE
TOTAL TOTAL
ROOM NO. GROSS GLASS NET WALL CEILING FLOOR CU.FT. AT 70•F CORRECTED -J j LL LL REGISTER
L W N AND TEMP. TO tF F; TYPE AND SIZE RAD. OR LEADER
SIZE WALL f'LtC (INFILT.) DIFF. 'F F m N SO' FT. FREE AREA
TOTALS
A. HEAT LOSS FROM BUILDING B.T.U./HR.
B. DOMESTIC HOT WATER DEMAND- B.T.U./HR.
C. PIPING, OTHER THAN NORMAL B.T.U./HR.
ALLOWANCE FOR HEAT VALVE OF FUEL (AA 9 C) FACTOR ( �
17. ELECTRICAL WORK BY: /J'���r `/ V 0417 / tQ1,
NAME ADDRESS
SUBCONTRACTORS AND
te. THEIR TRADES
ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE (OWNER) OR (AGENT) OF THIS PROPERTY AND WILL
BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE.
APPLICATION TO BE COMPLETELY FILLED IN.
1f Rti
ATE SIGNA UR[ OCANT
.:
• E �r � f I
TALL
•
OF
m ���
f i •
i
Ems
t AS
�� , , , �•
i • i ills
MOrWRArvr l / 1 � • •' •
MEN Mv
MEN
=loom
WL-113 ion 11110
no"A
/ i • it �/ • , ., r • i ,,
Building APPLICATION FOR BUILDING PERMIT
Plumbing
HVAC Date:tO
Sprinkler
Electric Estimated Cost $ .aoo-
Zoning Permit Fee$ 60"'
Affidavit NO. 17327 Occupancy Fee $
Eng. Dept.
Fire Dept. COMPLETE RED BOXED AREAS. Total Fee $ •aa
Health Dept. TYPE OR PRINT ONLY
Approved SIGN ON REVERSE SIDE.
TO BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT
The undersigned, hereby applies to do work according to the following specifications:
Job Location Lot No. Side of Street Zone
Applicant'A -1. AAT_!l, Cooh7 1!1-r Tel. # 6/6—�
Address sa &LiV aame4 e r Lic. # Se30 K Zip 04 400
Owner-45zC,Auz 64"Z* Address 19 40AZAC114F c°,lMC&
Architect Address
Size Main Building: Ft. Front Overall Ft. Deep Overall Total Area Garages
Lavatories
No. of Families No. of Stories—Construction WO on Bathrooms — Rooms 1st 2nd 3rd
Size of Lot Dist. from Street Line Dist. from
/Side Street Line
Purpose of this Permit PCAtZelv=4t EZ4L Ia o�� �a^' AP/
City Water ❑ Well ❑ Septic ❑ Sewer ❑
Approved by Date /00 �2
Dist. from lot line E. , W. , S. , N. , Dist. nearest Bldg. ft.
Height of stories -cellar 1st 2nd 3rd 4th 5th
Found depth below grade 1f i`r Above gradei� Material for footing 6204(-f,
Size footing Material for found. Found. thickness
Roof No. of stairways Size of girders
Material for Side Walls Size of pier found.
Floor joists, size: 1st 2nd 3rd stories. Dist. on center
Longest span of floor joist: 1st 2nd 3rd If not wood joist const. what type of floor?
Size of Roof Rafters Longest span on center
Chimneys, size of flues How many? Where does the start?
Plumbing contractor, Permit No. Oil burners, Permit No. Plot Plan Rec'd:
VH/i ating contractor, Permit No. Checked by Eng. Dept. ;
Electrical Permit No. Signed b Engineer:
9 Y 9
Sprinkler Permit No.
I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to
notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked, and agree that this
building is to be located the proper distance from all street lines,side yard lines and required distances from all other zones and is located in azone
in which this building and its use is allowed.
hereby apply for a Certificate of Occupancy for
described in the above application for permit.
Signed to/,�,61eV &VIC , (&C
i
REINO E. HYYPPA a ASSOCIATES
CIVIL ENGINEERS 9 LAND SURVEYORS
GAS TONBURY, CONN.
g�
I -7b
14
e �
1 -1
RzSo. / �,qR
t
P
78
so
� 1 ` �•.
- ,
1 _
LL-
CIO
t 4
Z \ \27
o _ a (V
�-- ',A REA=
u- 26", I I `S-F
l� 6�d 1
, I ,
It
bZ
LET Lt NES tAA,P UV FILE T\r,LE ', 7Q �0"jto
'��cal SFALE :�USDIVtS`JtJ A-"cam i pN6. �Q/T�C+Y}� .��^�O'V
FLOT P�AIJ Z
VALLEY HokAe M so,. Wit4osoQ, 5�� ��y�✓��UC T
Of4W."By ReIwo E.Wvypm�Assoc=Es C r/Q,vBOA
G►v�t-UfC�hlEE:�: *LANP gU2.vEvoQ-s
GI.A---70 1e>uw-y,CONN. SCALE 0=40'
DABS �-q-85 MncNO.4?-8o-II PR��AREC FOR
5HEE- 3 -3F I SNEE--S.RW.. 10-►0-85 PLEASANT VALLEY HOMES II
CEiZT1 Ft E Suf=STG,NT;"-t-LYJ•ocT C4,T;.: 2-S
��- 001
i
0 C i 1 1 1988
South Windsor
BUILDING DEPARTMENT
TO THE BUILDING OEPT. TOWN OF SOUTH WINDSM,
This certified that this plan and specifications are true
copies of the proposed building or alterations to be
erected at
fogetber with amendments stated in eppl-c ti-n an,'
filed with plan and I agree tc con,ply it 7nnlnk.
Building and state laws and SJCn oru t, r, h D
issued by the Building Dep,irtmF n, ct.,nng pend,,n(y
of this application and final issuance of a buildlni
perm it. n
Signed 4 is
this plan s apilroved subject to the condition th+'
orders and ordinances regulating buliding shall be
Yomplied with
ondltionally Approved These filed with
J&-
Building Inspector Clerk
/p'/I ef m/2 5J7
i a 7d1
ELECTRICAL APPLICATION
Application No.
on the side of
I
A 1 " Street
Street No. 19
Owner S'
( d
Electrician n
FILED IN OFFICE OF
The Building Inspector
//1993 19 AO
INSPECTION.
M No Electrical Work shall be started until a Per-
mit is granted by the Building Inspector.
In New Buildings no wiring shall be started
until the plumbing and heating pipes. and the Are
stops (if of wood) are installed, without a special
permit from the office of the Building Inspector.
Electrical Permit No. ......1,07-0-k-
Master License No. ..2Y............
TOWN OF SOUTH WINDSOR Building Permit No. I..7-3-a?....................
BUILDING DEPARTMENT Date Filed ... .................................
Date I.B�al rova ... . .....
APPLICATION FOR ELECTRICAL WORK
Electrical n pector
OBLOCATION: ................ ........................................... JOB OWNER: ..............................................................................................................
Sideof B tween ..r)...... ....... ...........I............................. .....Pd .... .......................................
Name of Building Owner .................... ....... ... �5 h'"'c-J'V
If work is for Lessee—Give name ........****". ............... ... ......... Address /. .. ............ ....... ......................................
Address .........................................................................
Building now occupied as (unless new .... ........ No. of family units now ............I'
........................
Building to be occupied as .......... ..................... ......... ... ......... ..... ..... . .......... Number of family units to be ....................................
W
Is this work included in a Building Permit? Permit Fee ........./'4T..�.(....... .................................................................................
(if no Building Permit
Permittee o�.-Ct kt-ue( ... Business Address Telephone.,S.
COSTOF INSTALLATION: 611-tl. ................................... .... .......................... ...................................................................................
TO BE FILLED OUT BY PERMITTEE
TO BE WIRED I EXISTING APPLIANCES
Number of light outlets to be installed Number of present Appliance Circuits Number of convenience outlets to be installed .................................................
Number of switches to be installed Do these include Range ❑ Water Heater
❑
Number of appliances to be installed
(as listed below) Dryer ❑ Air Conditioner Q Oil Burner ❑
TYPE RATING NO.
Dish Washer ❑ Gas Burtrer C3
Range . . . . . . . .
Range Top . . . . . . Well Pump Elec. Heaters
❑
Oven . . . . . . . . REMARKS:
Water Heater
Clothes Washer . . . .
Clothes Dryer . . . . .
Dish Washer . . . . . .
Air Conditioning Motor .
Oil Burner Motor . . . .
Gas Burner . . . . . .
Circulator Motor . . . .
Attic or Large Fan . . .
Well Pump . . . . . .
Electric Heat . . . . .
Other . . . . . . . .
Number of new Lighting Circuits . . . . ............................
Number of new Appliance Circuits . . . ........... ............
Number of Heating Circuits ......Number of Motor Circuits . . . . . . . ..
Size of present service ............... .. .................................................
Size of service to be ..................................................................
DATE:APPLICATION-FOR HVAC PERMIT Zi4e�,O/ro
TOWN OF SOUTH WINDSOR EST. COST'
FOR OFFICE USE ONLY 1540 SULLIVAN AVENUE nm 4 Zg
N . SOUTH WINDSOR# CT.0 6 0 7 4 FEES:
BLDG. PERMIT NO. 3 $ 0 -$1000 - $1Q.;00
�� 644 114 230 $1000 r friction
/' ��' thereof - $10.00
LOCATION OF BUILD=G
ti TO FH= NO,
OWNER
,o7r 7/-7, ( �_ � �� c�2 av coNrRAcroa AD REss. too NO.
/ of vILDIr�c: RESIDl1�IAL
1ZPE OF SYSTEM
A/C TYPEB
vE�nrrzATION- BVSn a
. INDusTu�►L
STDIMATING: __ZIP LIIIIT B?
_LBs. HIGE PPmSVRi LI _L8S•
H?DRCNIC VAS AIR_
UNIT RADIANT EEATER(INCLuDING MOOD/COAL BUNG STOVE)__
1'tPE 07 Ptt$L: OZL-m_._ GAS 13-PUT... M•ECCTEIC EW_
WOODCOAL
OIL TAN - SIZE i LOCATION: INSIDE_ OQrSIDE CAPA�CIIT__
LPG TAM - CAPACII?__ ITIO11AL PAD TOTAL 101j;=1 MCI T RADIANT —'�
ovrsiDa--l� INSIDE 6' F D -
nEszGu IIlT kCCMffANT APPLICATION
TOTAL. BaAT Loss (BTM) s'�' � ( . Loss Isar
DESCRIBE ALL MS EQUIP T CrUDIM •
GBoss aE� CAPACITY (UQTTr BTM) NET c cow- )
op
. CpipDl'tl0ipI14G: DESIGN TII�. OUTSIDE_F INSIDES�F
IF AIt Tom UkT a (BTQg)
(SW GA IH man )MST ACMWAXY APPLICATION)
DESCRIBE ALL COOLING E (INCLUDIi1G 1"M A MOIL NO*):
C omw CAPACITY(BTUB)
DESCRIBE ALL AI�BAi�DLI11G E'Q� (INCLUDING EITCHEN T Equumm
IF VE1iTII.A1'IOH.•
TOTAL SIZE OF SYSTEM (am) FRESH AIS INTAKE (CM
(Po EST A=WANT APPLICATION
The undersigned hereby applies for a permit to perform the following work sad is t
comply
with all local ordinances and State Of Cone. Building Codes in the performance
f such work.
FURTHER DESCRTION OF WORK:
SjMATURL'/00 Zn r 0 APPLI
TATE LI S 6 E TE
_ZL
DATE
_ r
1!
I B=R CALCULATION SHEET 1503 (Modwn Method) Copyright 1977 by The Hydr nits institute
OWNER A013RESS OESION TEMPtRATUNS OIFFSRENCt P.� DATE
COL.A COL.S COL.C COL.D COL t COL.F COL.a
FROOM t�l
0,; H L W 11 L W H L W H L W H L WNm Water Temp.
U STUN per F t f
SIONS,iT. URNIatIM SNae/NOSED WALLS.FT.OUTSIDE DOOR AREA
��.
i BTU" STUN STUN BTUM STUH
I
S WALL CONSTRUCTION RO M LIN.FT.OF
ITeble 9,Line 3 x HI TOTAL: RADIATION
PROM LINK 12 BtLECTtD
S TYPE OF GLASS
(Bottom of table used for Ling 51
C
7 !CEILING CONSTRUCTION
(Table 9.L x W) O
S FLO R CONSTRUCTIONt E
(Table 9.L x W or Lin.F L)
91 COLO PARTITION CONSTRUCTION F
ITabla 9.L x H)
10 r 1 Wall(With Openings) O; H
2 Walls(With Openings) J I
3 3 Walls IWlth Openings)or Ens.Hall r
J
11 TOTAL BTUH AT 70F TEMP.OIFFERENCE' K
12 T TAL STUN AT DESIGN TEMP.DIFFERENCE
L
COL.B COL.H COL.1 COL.J COL.KCOL.L
COL.A TOTAL STUH TOTAL
Of BUILDING RADIATION
AT SELECTED
1 ROOM C' H L W H L W H L W H L jp
L W OtSIGN TEMP.*
DIFFERENCE
t-
2 ROOM DIMENSIONS.FT. V -- --- —
3 LENGTH EXPOSED WALLS,FT. <
4 WINDOW AND OUTSIDE DOOR AREA
STUH BTU" STUN BTU" STUN
0114CREASE BATHROOM
5 WALL CONSTRUCTION TOTAL 20%
(Table 9.Line 3 x HI
S TYPE OF GLASS
1 (B ttom liable used for Ling 51 tFOR CONCRETE FLOOR ON
AT
7 CEILING CONSTRUCTION GROUND FILL
GRADE LEVEL.USE
LINEAR
(Table 9.L x WI FEET OF EXPOSED EDGE
S FL R CONSTRUCTIONt
ITabla 9.L■IN or Lin.Pt.)
9 C LD PARTITION CONSTRUCTION
(TeMe 9.L t H)
110 y 1 Well I W hh openin@d
e3
i ,% 2Wails1Widt pens $X
_ J
B 3 Wells IW11h peningd r Ent.Hall 1-
11 T TAL STUN AT 70F TEMP.DIFFERENCE•
12 T TAL STUH AT DESIGN TEMP.DIFFERENCE
FORM 1303
This form is evadable from The Hydronics Institute,36 Russo►lace,Berkeley 1,100 ,N.J.07922
PARK PLUMBING SUPPLY
IBR HEAT LOSS CALCULATION #10IG72 11/15/88
%40B NAME---- : CHUCK------------------------------------------------------------------- L-OeAT-mu--------1-9 ---------------------------------
WHOLESALER : PARK PLUMBING CONTRACTOR : GATES GRONDIN
PREPARED BY : HARVEY JOB REMARKS : ADDITION
------------------------------------------------------------- -------------------------------------------------------- -----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
ROOM # ROOM NAME FACTOR ROOM SIZE BTU LOSS FT BASEBOARD
1 ADDITION 2. 00 8X14. 5X 12 6086. 08 10. 7
-----2---------------OLD---P-ART'----------------- - -8 X------ 1-6X---- -- -------- ---------------------------
TOTALS 9987. 52 17. 5
DIME-NSJ0NAL----DATA----------- -------- - ------------ -- ----------------- ----------- -- --- ------- - --- ------------------------------------
SQ. FT SQ. FT SQ. FT SQ. FT CU. FT SQ. FT
RM. # NET WALL GLASS EXP CEIL EXP FLR VOLUME LIV. AREA
-------I---------- -------- ----------276-------- -------------- ---32- - 174- ------ - ------------- - --13q2--- -- ------- ---------- ----- ---------
2 192 0 0 192 1536 192
TOTALS 468 32 174 366 2928 366
------RTJJ---i4EAT--tf1S8------DATA------ ------ - -- -- - -------- ------ - -------------- ---- --
RM. # WALL LOSS GLASS CEILING FLOOR INFILTRATION TOTAL BTU
1 1545. 60 1561. 60 417. 60 556. 80 2004. 48 6086. 08
--- - ----2- 1-07-5.--20 -- ---0. 00 - ---G.-GO - 614. 40 221--1-.--84 3901.- 44
TOTALS 2620. 80 1561- 60 417. 60 1171. 20 4216. 32 9987. 52
% OF TOT. 26 16 4 12 42 100
THE AVERAGE BTU PER SQ. FT. OF LIVING AREA IS 27. 29
THE AVERAGE BTU PER CU. FT. OF LIVING AREA IS 3. 41
FACTORS USED IN CALCULATION
BTU\F1'
FACTOR # WALL GLASS CEILING FLOOR INFILT. OUTPUT TEMP
2. 00 0. 07 0. 61 0. 03 0. 04 0. 18 570 80
3. 00 0. 07 0. 61 0. 03 0. 04 0. 12 570 80
PARK PLUMBING SUPPLY
IRR +4EAT LOSS CALCULATION #101072 11/15/88
---j(3B --NAME--------------:�-C-K--------------------------------------------------------------------------------------------jGB-----LOC-AT-1-ON------:----1-9-----CHAR-L-1-E:--C---1-ft---cS------W-I*-------------------------------------
WHOLESALER : PARK PLUMBING CONTRACTOR : GATES GRONDIN
PREPARED BY : HARVEY JOB REMARKS : ADDITION
----- ---------------------------- --------------------------------------------------------------------------------------- ----- -------- ----------------- ---------------------------------------------------------------------------------------------------------------------------------------------------I--------------------------------
ROOM # ROOM NAME FACTOR ROOM SIZE BTU LOSS FT BASEBOARD
1 ADDITION 2. 00 8X14. 5X 12 6086. 08 10. 7
----2---------------------OLD---P-A-RT-----------------------3-.--00- -------- --------BX---------16X---- -----1 ------ ---- 390-1-------44 ------ ------- - -------------- - --6.---8------- -------------------------------------
TOTALS 9987. 52 17. 5
---N-l"M---I0NAt---DATA------------ --- - - ----- ---------- ------- ------ -- --------- -------- ---- --------- ------------ -
-----
SQ. FT SQ. FT SQ. FT SQ. FT CU. FT SG. FT
RM. # NET WALL GLASS EXP CEIL EXP FLR VOLUME LIV. AREA
-----1---- ----------------------------276---------------------- --- --32- 174- -1-74--- ----- - 13q2-- -- ---- -------1-74-- ---------------------
2 192 0 0 192 1536 192
TOTALS 468 32 174 366 2928 366
--------BTU----HEAT----LOS-S-----DATA-- --- --- ----- -------- --- ---------------- ---- - --------
RM. # WALL LOSS GLASS CEILING FLOOR INFILTRATION TOTAL BTU
1 1.545. 60 1561. 60 417. 60 556. 80 2004. 48 6086. 08
2 - ---- 1-075.--20 0. 00- 0. 00 - 614. 40- 2211, 134 ------ 3901-.-44
TOTALS 2620. e0 1561. 60 417. 60 1171. 20 4216. 32 9987. 52
% OF TOT. 26 16 4 12 42 too
THE AVERAGE BTU PER SQ. FT. OF LIVING AREA IS 27. 29
THE AVERAGE BTU PER CU. FT. OF LIVING AREA IS 3. 41
FACTORS USED IN_ CALCULATION - -----
BTU\FT
FACTOR # WALL GLASS CEILING FLOOR INFILT. OUTPUT TEMP
2. 00 0. 07 0. 61 0. 03 0. 04 0. 18 570 80
3. 00 0. 07 0. 61 0. 03 0. 04 0. 18 570 so
-------- -- -- -----
BONAdingNSPE z O s: APPLICATION FOR BUILDING PERMIT
Plumbing
HVAC Date: an nrL
Sprinkler 19 CHARLIE CIRCLE
Electric LY SL C � Estimated Cost 13 f000
Zoning Permit Fee$ -2-256
Affidavit NO. 19971 Occupancy Fee $ 3
Eng. Dept. COMPLETE RED BOXED AREAS.
Fire Dept. TYPE OR PRINT ONLY Total Fee $
Health Dept.
Approved for CO: 1`t* F Z cl SIGN ON REVERSE SIDE.
(Additional Cost) $
TO BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT
The undersigned, hereby applies to do work according to the following specifications:
Job Location 19 C*AA Vt L 1 E Q ICC'_I _IE Lot No. Side of Street Zone '►-12,�
Applicant GR E G Ale-rclaj CAi'P K k1:j QY Tel. #
Address 255 no g -T,,w,.► 9,m )61 imnWR_ C�_f Zip 1:14Pn"I 67 Lic.# 151"1�5 Vses
STREET CITY STATE
Owner S i�d wiu Ci{Llr-1c- Address 151 C 4htz-►-IFE CtKCLE , .Val��daSof�
Architect Address
Size New Area: Ft. Front Overall*-F Ft. Deep Overall ►fI-- o Total Area 34 0 RA FW Garages
Size of Lot Dist. from Street Line Lavatories_Bathrooms Rooms 1 st 2nd 3rd
Purpose of this Permit E�Xlrh-r i N e,%
t W27TI E4 OA�e!- Q- _PA ue
City Water**� Well ❑ Septic ❑ Sewer
Use Group Construction Type 5;d
Approved by Date BD1A 11/88
I h r by agree to conform to all the requirem nts of the Laws of the State of Connecticut and the Ordinanc s of the Town of South Windsor
and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree
that this building is to be located the proper distance from all street lines,side yard lines and required distances from all ottWr zones and is
located in a zone in which this building and its use is allowed.
Signed
I hereby apply for a Certificate of Occupancy for the work describ in this a lica ' or p it.
Signe
—DO NOT WRITE BELOW THIS LINE—
INSPECTION RECORD _ $ 9 2
Footing ` 9'2 Framing
1P%eu.s —� . tt�,, ► �i 'L � G� '
Foundation Fireplace/Chimney Insulation b
Plumbing Permit# Inspections:
HVAC Permit# � Inspections:
92
Electrical Permit# fo� Inspections: —`�Z
Sprinkler Permit# Inspections:
Inspection / Approval Date By Appl
Code Description Due Whom Code Comment
-------------------------------------------------------------------------------
92-19971-B 23,000
B01 FOOTING 06/02/92 003 A
B03 FRAMING (ROUGH) 06/18/92 003 A BLDR W/BRING DOCUMENTATION FOR STEEL BEAM
P03 ROUGH 06/25/92 003 A
E03 ROUGH 06/25/92 003 A
B04 INSULATION 06/26/92 003 A
E03 ROUGH 07/10/92 003 A OK BASEMET
B01 FOOTING 07/16/92 004 A
B10 FINAL 07/24/92 004 A APPROVED FOR CO
92-12230-E 1,000
92-9065-P 500
92-8507-H 1,000
Total Est Value 25,500
Inspection / Approval Date By Appl
Code Description Due Whom Code Comment
-------------------------------------------------------------------------------
92-19971-B 23,000
B01 FOOTING O6/02/92 003 A
B03 FRAMING (ROUGH) 06/18/92 003 A BLDR W/BRING DOCUMENTATION FOR STEEL BEAM
P03 ROUGH O6/25/92 003 A
E03 ROUGH 06/25/92 003 A
B04 INSULATION 06/26/92 003 A
E03 ROUGH 07/10/92 003 A OK BASEMET
BO1 FOOTING 07/16/92 004 A
B10 FINAL 07/24/92 004 A APPROVED FOR CO
92-12230-E 1,000
92-9065-P 500
92-8507-H 1,000
Total Est Value 25,500
I � 1
REINO E. HYYPPA a ASSOCIATES
CIVIL ENGINEERS a LAND SURVEYORS
GLAS TONBURY, CONN.
\
ec�
\ lb
1 %
3 80
\ 4e'3410
` ► L!� _ 1 i
Ln '� N
LL ?g cli N RROPOSreA
71
z
o -
� Q 0�0
Lli
`A F EA=
20,t i 1, �`S.F
cG
LOT LIINcS FP.,7D ; M4=-7V FILE T17LSZ;, 4`�q�/
�•FAGr :�U°i Div is- .3N L> `pNE �,�/ �A }� '4
VALL.=y HoM II SovTN Wlr,,o�,p�� �t r (�/r�U' 7•�
Cn_NN."g-y Rc!uo E.W-,vPP ,+A_soc.tAT�
Uv!L��.ft_��t.iEE:�: * IAtJ�4•U^vE�oRS �,�' .
GI�t�T01.161.1Ry�GONN. SCALE 0=4.0'
w1ccNo.4�-60-II � ='AREA FOR
Q R v v 10-10 5 FL E4` SA N T VX LEY HOMES, H
v
FoN.L.c�cAZeAass �-►4-8c. �C�.1TF� 1�1;IN J�•Orc. CQNtJ,
v '
`E2'TI FI E Z.,' '--,uesTar1l.rt-I-LY �T -�a�: I"=40'
100
I
7 rt L
J�tL• '�, 'M �to �.
�. �. MAY 2
JUUsii
DUiLQIiNG DEPART�IVIIENT
L;rc/C,
r,L;eoralld Approve,44 The ba ti;e'� iC�Tio�ll or
posed bullding(s), use(s) andlor stru=t' = ;
as shown on this plan appears) to
tprifo with current C,
South WrI _
cea•� regulatkM Variances and special exceP
Z Ing Enforcement officer
PERMIT #
DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT
Application is hereby : TOWN OF SOUTH WINDSOR
APPROVED ISAPPROVED BUILDING INSPECTION DEPT.
644-2511 Ext . 230
--JR.--q.Z Application must be printed or typed .
Date Building Inspector
1. LOCATION OF JOB
ZF Gbt-rl/ c c
No . Street
FEE SCHEDULE -y-
$ 0 - $19000 - $10.00 Floor Apt . No.
Over $1 ,000 - $10.00 U
1 2 . OWNER
per $ .000 or
fraction thereof 3. ADDRESS / [ C`i6�'���
4. APPLICANT
5 . ADDRESS
So C 7 (00 Q,b
� o�
6 . ESTIMATED COST $ �G b .
7 . IS THIS A CONTRACT COST
Yes No
8 . FEE ENCLOSED $
e�xoIRf7 �
9 . TYPE OF BUILDIN
4A�e
CRESIDENTIAL COMMERCIAL
10 . TYPE OF JOB :
Original Installation
Alteration/Addition/Repair
BD 3A 11/88
APPLICATION FOR ELECTRICAL PERMIT (Continued from Reverse Side)
11 . LOCATION OF JOB Zz
NO . STREET APT. NO
12 . TYPE OF INSTALLATION
13 . SIZE OF MAIN FEEDER
14 . NO . OF LIGHT LOOPS 15 . NO. OF HEAT LOOPS
16 . NO . OF POWER LOOPS 17 . NO. OF LIGHT OUTLETS
18 . NO . OF HEAT CIRCUITS 19. NO. OF POWER OUTLETS
20 . NO. OF CONVENIENCE OUTLETS 21. NO. OF HEAT CIRCUITS
22 . NO. OF POWER CIRCUITS 23. NO. OF LIGHT CIRCUITS
24. SIZE OF HEAT CIRCUITS 25 . NO. OF MOTORS
26 . NO. OF PANELS 27 . TOTAL WATTAGE
28 . NO. OF POWER FEEDERS 29 . NO. OF SWITCHES
30. A/C LOAD 31. SIZE OF POWER FEEDERS
32 . NO. OF FIXTURES 33 . TOTAL HORSEPOWER
34 . NAME OF SUBCONTRACTORS AND THEIR TRADES
35 . REMARKS AND FURTHER DETAILS :
LICENSE NO. SIGNATURE OF APPLICANT DATE
PHONE NUMBER:
PERMIT NO.
DEPARTMENT DECISION APPL I CAT I O N FOR
Application is hereby : PLUMBING PERMIT
TOWM OF SOUTH WINDSOR
AP ROV DISAPPROVED BUILDING INSPECTION DEPT.
644-2511 Ext. 230-. .
`J 'vim
D A a Building Inspector Application must be printed or typed.
1. LOCATION OF JOB:
FEE SCHEDULE 2. OWNER:
3. ADDRESS:
$ 0 - $19000 - $10.00
Over $1 0 0 0 - $10.0 0C�
n
per $1 ,0 0 0 or 4. APPLICANT:
fraction thereof
5. ADDRESS: /;Z �L)12-r
eas+/Va +f0,C-0 al [!�
6. EST. COST: $ �Q0,OCR
7. IS THIS A CONTRACT COST? YES NO
8. FEE ENCLOSED: $ /01 UQ
19 7)
9. TYPE OF BUILDING:
RESIDENTIAL COMMERCIAL
10. TYPE OF JOB:
ORIGINAL ALTERATION
INSTALLATION ADDITION
REPAIR
BD 2A 11/88
APPLICATION FOR PLUMBING PERMIT (Cont. from Reverse Side)
11. LOCATION OF JOB: C� 6t! -,,b r-- 0(ve 4e-
GENERAL PLUMBING
12. KIND OF INSTALLATION:--, . 13. SIZE OF MAIN DRAIN
14. NO. OF TOILETS STYLE / 15. NO. OF URINALS STYLE
16. NO. OF BATHTUBS 16A. NO. OF SHOWERS 17. NO. OF LAVATORIES
18. NO. OF SINKS 19. DISPOSAL 19A. DISWASHER
20. NO. OF CONDUCTORS SIZE 21. NO. OF STACKS SIZE
22. AREA OF ROOF 23. NO. OF CATCH BASINS 24. NO. OF FLOOR DRAINS
25. NO. OF OTHER FIXTURES KIND
26. ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW?
27. SIZE OF WINDOW
28. IF NO WINDOW, WHAT KIND OF VENTILATION IS THERE?
29. SIZE OF DUCTS 30. SEWER OR SEPTIC TANK?
31. SIZE OF WATER MAIN 31A. SIZES OF WATER PIPING & RISERS
32. REMARKS AND FURTHER DETAILS yrou ry, V+-0- 0,10ck cs,. 4 V,�.e
WATER HEATER
33. TYPE 34. MANUFACTURER
TANKS SAFETY DEVICES
TE1,1PERATURE
35. CAPACITY 39. RELIEF VALVE
36. TEST PRESSURE LBS. 40. MANUFACTURER
37. WORKING PRESSURE LBS. 41. PRESSURE RELIEF VALVE
38. TYPE 42. MANUFACTURER
R0 3 �1-I1 G L e 2rt��(
LICENSE NO. ATE SIGNAtt F 1APPLICANT
PHONE NO.
FOR OFFICE USE ONLY APPLICATION FOR HVAC PERMIT DATE: ?- ) a-
(NO. W.5 to 7 ) TOWN OF SOUTH WINDSOR EST.COST:
BLDG. PERMIT 0. q*-7 f 1540 SULLIVAN AVENUE FEE .O'U
SOUTH WINDSOR, CT 06074 FEES:
644-2511 - Ext. 230 $ 0 - $19000 - $10.00
$1000 or fraction
LOCATION OF BUILDING ��1 C�� , thereof - $10.00
�/Cue^/ S, U✓. Y - ?
0 ER ADDRESS TOWN PHONE N0.
'452!�vom,-_s Cc-), Cam✓. J- 0?6fi
HVAC CONTRACTOR ADDRESS TOWN PHONE NO.
TYPE OF SYSTEM: HEATING ✓ TYPE OF BUILDING: RESIDENTIAL__6e�f'
A/C COMMERCIAL
VENTILATION BUSINESS
INDUSTRIAL
IF HEATING: STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS.
HYDRONIC WARM AIR
UNIT RADIANT HEATER (INCLUDING WOOD/COAL BURNING STOVE)
TYPE OF FUEL: OIL-GPM GAS IN-PUT ELECTRIC KW
WOOD COAL
OIL TANK - SIZE & LOCATION: INSIDE OUTSIDE CAPACITY
LPG TANK - CAPACITY
EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION
DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT LOSS (BTUH) (HEAT LOSS SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE & MODEL NO.):
oaak2o TO- e)Cie)
GROSS HEATING CAPACITY (INPUT-BTUH) NET RATING (OUTPUT-BTUH)
IF AIR CONDITIONING: DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT GAIN (BTUH)
(HEAT GAIN SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE & MODEL NO.):
TONNAGE COOLING CAPACITY (BTUH)
IF VENTILATION: DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN EXHAUSE EQUIPMENT):
TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM)
(PLAN MUST ACCOMPANY APPLICATION)
The undersigned hereby applies for a permit to perform the following work and is to comply
with all local ordinances and State of Conn. Building Codes in the performance of such work.
FURTHER DESCRIPTION OF WORK: ieze evpe 6 U Se b6rap-ell P /,%/
f P40';J a/./ �',[�2 !� 1P r r�-�Zd Z/ SCc syct �2n Ga:24
02 ��l (s - -f� V
z�2,_J�-
STATE L CENSE - NAME & TYPE # DATE I NATURE OF APP I ANT
APPROVED bAA
_ BD 4A 11/88
I = B - R CALCULATION SHEET 1503 (Mod rn Method) Copyright 1977 by The Hydronics Institute
OWNER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATE
COL.A COL.B COL.C COL.D COL.E COL.F COL.G
1 ROOM
O H L W H L W H L W H L W H L yy Design Water Temp.
2 ROOM DIMENSIONS, FT. H
U BTUH per F of of
3 LENGTH EXPOSED WALLS,FT. Radiation Selected
4 WINDOW AND OUTSIDE DOOR AREA LL
BTUH STUN BTUH STUN STUN
WALL CONSTRUCTION ROOM LIN.FT.OF
(Table 9,Line 3 x H) TOTALS RADIATION
5
rFROM LINE 12 SELECTED
6 TYPE OF GLASS
(Bottom f table used f r Line 5)
7 CEILING CONSTRUCTION C
(Table 9,L x W) D
g FLOOR CONSTRUCTIONt —
_
E
(Table 9,L x W or Lin. F t)
9 COLD PARTITION CONSTRUCTION F
(Table 9,L x H) G
10 c 1 Wall(With Openings) H
=o X
2 Wells(With Openings) D J I
3 Wells(With Openings) or Ent.Hall
11 TOTAL BTUH AT 70F TEMP DIFFERENCE'
K
12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE
----- L
COL.A COLS COL.H COL.1 COL.J COL.K COL.L TOTAL BTUH TOTAL
-- — --- --- — OF BUILDING RADIATION
1 ROOM ¢ AT SELECTED
O H L W H L W H L W H L W H L W DESIGN TEMP.°DIFFERENCE
�
2 ROOM DIMENSIONS, FT U — _
3 LENGTH EXPOSED WALLS. FT. Q
1 WINDOW AND OUTSIDE DOOR AREA LL
BTUH STUN STUN BTUH BTUH
5 WALL CONSTRUCTION *INCREASE BATHROOM
(Table 9, Line 3 x H) TOTAL 20'r<
6 TYPE OF GLASS
(B ttom f table used for Line 5)
�_ — -- f FOR CONCRETE FLOOR ON
7 CEILING CONSTRUCTION GROUND OR FILL AT
(Table 9, L x W) GRADE LEVEL,USE LINEAR
B FLOOR CONSTRUCTIONt FEET OF EXPOSED EDGE
(Table 9, L x W or Lin Ft)
9 COLD PARTITION CONSTRUCTION
(Table 9, L x H)
10 1 Wall(With Openings) - - --------_—_-- -------- —
2 Walls(With Openings) G X -- --_— — _
J
3 Walls(With Openings)or Ent. Hall
11 TOTAL BTUH AT 70F TEMP DIFFERENCE'
12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE _
FORM 1503
This form Is available from The Hydr nice institute,36 Russo Place,Berkeley Heights,N J 07922
ENGINEERING DESIGN ASSOCIATES INC.
Structural-Civil Engineers
62 Bloomfield Avenue Windsor,CT 06095
(203)688-8756
June 12, 1992
Marris & Wert
97 West Dudley Town Road
Bloomfield, Connecticut 06002
Attention: Mr. Dave Wert
Reference: Steel Beam Review
Chuck Residence, S. Windsor, CT,
Dear Dave:
This letter is to inform you that I reviewed the use of a W14 x 34
steel beam for support at the Chuck Residence, 19 Charlie Circle,
South Windsor, Connecticut. The clear span of the beam is 18 '-8" and
is supporting the Second Floor and Roof of the existing residence and
the Roof of the new Addition. I have determined that the W14 x 34 is
capable of supporting these loads in accordance with the Building Code
of the State of Connecticut.
If you have any questions or require further information, please do
not hesitate to contact us.
my urs,
�a�
ENGINEE NG ESIGN AS CI TES INC.
Andrew J. lica, Jr. E.
rnr
rrnnsun
President ��Np�01111 If
a a. P4 �'-
+
GO, 14
m
Qlt
s At. No. 13948 41/,
���t�`s•�cEN
`���0 Vidu:u
JUL 4 9 �yyc
South Windsor
BUILDING DEPARTMEN T