Loading...
HomeMy WebLinkAbout118 Carriage Drive s� 00 o ro THE BUILDING INSPECTOR r 'b 3 '?R , 3 re of thrr APPLICATION FOR PLAN EXAMINATION AND TKO" OF SOUTH WI WWK cow BUILDING E X PERMIT z IMPORTANT — Appli ant to comp a all items in sec 'ons: 1, 11, III, IV, and IX. O A ZONING • AT (LOCATION) D I S T R I C LOCATION (NO.) (STREET) OF BETWEEN AND BUILDING (CROSS STREET) (CROSS STREET) 000, LOT SUBDIVISION LOT BLOCK SIZE N II. TYPE AND COST OF BUILDING — All applicants complete Parts A — D �v A. TYPE OF IMPROVEMENT D. PROPOSED USE — For"Wrecking" most recent use � 1 ® New building Residential Nonresidential 2 ❑ Addition(If residential, enter number 12 W!] One family 18 ❑ Amusement, recreational of new housing units added, if any, in Part D, 13) 13EJ Two or more family — Enter 19❑ Church, other religious number of units— — — — -- 20❑ Industrial 3 ❑ Alteration (See 2 above) 14 Transient hotel, motel, ❑ 21 ❑ Parking garage 4❑ Repair, replacement or dormitory — Enter number 5 ❑ Wrecking (If multi/amily residential, o/units ——————— — —s 22❑ Service station, repair garage enter number o/units in building in 15❑ Garage 23❑ Hospital, institutional Part D, 13) 16 ❑ Carport 24❑ Office, bank, professional 6 ❑ Moving (relocation) 17❑ Other — Specify 25❑ Public utility 7 ❑ Foundation only 26❑ School, library, other educational B. OWNERSHIP 27❑ Stores, merconfile ❑ 8 � 28 Tanks, towers Private(individual, corporation,nonprofit institution, etc.) 29❑ Other — Specify 9 ❑ Public(Federal, State, or local government) C. COST (Omit cents) Nonresidential — Describe in detail proposed use of buildings,e.g., food processing plant, machine shop, laundry building at hospital,elementary 10. Cost of improvement,,,,,,.,,,•,,,,, school, secondary school, college, parochial school, parking garage for, department store, rental office building, office building at industrial plant. To be installed but not included If use of existing building is being changed, enter proposed use. in the above cost a. Electrical...................... b. Plumbing ...................... c.Heating, air conditioning......... d. Other(elevator, etc.)............ 11. TOTAL COST OF IMPROVEMENT $ III. SELECTED CHARACTERISTICS OF BUILDING — For new buildings and additions, complete Parts E — L; for wrecking, complete only Part J, for all others skip to IV. E. PRINCIPAL TYPE OF FRAME G. TYPE OF SEWAGE DISPOSAL J. DIMENSIONS 30❑Masonry(wall bearing) 40 2] Public or private company 48• Number of stories................ 31 Wood frame 41 5C Private (septic tank, etc.) 49• Total square feet of floor area, all floors, based on exterior < 32 Structural steel dimensions .................... 33❑ Reinforced concrete H. TYPE OF WATER SUPPLY /Z 42 Public or private company 50 Total land area, sq.ft. ........... 34❑ Other — Specify p Pa Y 43 Private(well, cistern) K. NUMBER OF OFF-STREET PARKING SPACES F. PRINCIPAL TYPE OF HEATING FUEL I. TYPE.OF MECHANICAL 51. Enclosed ....................... 35❑ Gas Will there be central air 52. Outdoors....................... 96 0Z Oil conditi ping? L. RESIDENTIAL BUILDINGS ONLY IT 37 El ctricity 44❑ Yes 45 No 53. Numb r f bedrooms.............. 38 M C al 39 Oth r— Specify Will th re b an el vator$ Full.......... 54. Number of 46❑ Yes 47 X No batter ms Partidl........ NOTES and Data — (For department use) IV. IDENTIFICATION — To b compl t d by all applicants Name Mailing address — Number, street, city, and State ZIP code Tel. No. A Owner or 4�� Lessee t i 2. Contractor 3. Architect or Engineer The owner of this building and the undersigned agree to conform to all applicable laws of this jurisdiction. Signature of applicant Address Application date 4PJ-,c4LZL 1z A-,—e.."A--- 11,E.,, . U) - DO NOT WRITE BEL W THIS" LINE V. PLAN REVIEW RECORD — For office use Plans R view Required Check Plan Review Date Plans B y Date Plans, B Notes 9 Fee Started Approved y BUILDING 0( $ PLUMBING $ MECHANICAL $ ELECTRICAL $ OTHER $ VI. ADDITIONAL PERMITS REQUIRED OR OTHER JURISDICTION APPROVALS Permit or Approva I Check ObDa ned Nate umber By Permit or Approva I Check Obtained Date Number By BOILER PLUMBING CURB OR SIDEWALK CUT ROOFING ELEVATOR SEWER ELECTRICAL SIGN OR BILLBOARD FURNACE STREET GRADES GRADING USE OF PUBLIC AREAS OIL BURNER WRECKING OTHER OTHER VII. VALIDATION Building Permit numb r 10269 Bui Iding Permit issued May 15 19 78 Building Permit Fee $ 210.00 Approved by: TITLE ZONING • FRONT REAR YARD Ix. SITE OR • For . • S w 01 191" Ir.i MUSHUHHOSSR! In.: 0: ■ • 1 a !!. 1-8 a� H_ .wr:a!'.■:.aaa■Sa aa.aaaaa : r■.:.ia.s.a.. �'=:'a�-i sa .:a .rr�■. . ■ ii i•i. s ... . .0 ....a.s i... ... .... : .. .sa. S . .... . so: a •• s•• _ : Sam .� :: _wago_ ! ON _• •jill:11111jill:1! •!i Isi �ai • rSu■ �uuui■ n.o.■■�i.i =.wuuuu. =a�ia i.�is� • •■ • . • . .=a=. • . ... s.as wrar■w ■Saa.■S.rs . ■ a. ..■.. .r.w■ C ww .. � ■. wa as ■ iC i:�l = siS :lsa :: i�� Si: C: ===i :i: : =::�S:a-usallue nu iai�i;i=::`��_ :_?'=ll�i'�:= ! ��r S'� S!•.S`. a gul 1111i..S = aa�=:•SMullflul i: _Si�l S��ili1=:!••'i_`i!i':■'! ::::C:llC:C::::C'!a= •=a���aI� as 'S''�i a' �'aia ■i _ a !■'i:i�L:ii;::Us !_: was as SSO:ii:;;i:011 i6=:'.:s:a !a. is:ii S .seeISO n: ..i • a.S ;S■M ■ai .riwa.rii .... ..i! • !•::•:::s...:i•••:s:..l.■i:::s::' :: i �s� i$� S:i ..If IIIII!�=��zs:==�:��= ��s�::=:�:s�=��===i�:�:�i'ss:'see�fan s:::i:ual':=:s's u.�ss ids :� asi 9 ��:a :� 111101 ..a.s:::=:l::•:!!:•=•s ==•i =•:z..... =.s•: :::::I::=s ::is:=:••::_:l:lr:•:i�•� :=iss �' 111111111 i • • :;dui: :unlif::.=':: :='s' =s ::6: :':e:':::=e:• s:'s::'s:;e :=:::e :::e= '��. : . ";:. :::. mils . :au " i'• • _ a :5 �! S = _! �i! ii'.S= : __ � il 1l:s:::SS::=::=;:!le;;;=::ea:::C:C:sip:iti;: :s::::e::=::s::::::::��::::;:::e:eCi:l::i:::::::Y:::::_:S::sZ CCK=CS__=s� lsC zi ;CC::It s:el::t�:::::! TOWN OF SOUTH WINDSOR BUILDING PERMIT Date MAY 15 , 1978 ' r Est. Value 35. 000.00 Fee Paid $. 210.00 Permit © 1 0 2 F9 on the side of Loft �k16 Carrlag DriNatm-et Street No. 118 Owner RSK cnntrartnrc Applicant R SK r n„t rw;tor c CERTIFICATE OF OCCUPANCY ISSUED: Date No. 5141 Fee Paid $ 3.00 CLASSIFICATION Dwelling BUILDING PERMIT f 1069 9 OFFICE OF THE BUILDING INSPECTOR of the Town of South Windsor, Conn. May 15 78 South Windsor, Conn. 19 RSK Cc+n�:rac•tors 94is is to Trrtff#, That Dwelling is hereby granted permission to .00 at estimated value of $ Lot #16 Carriage Drive on the side of Street on land RSK Contractors owned by Work Said to be as described in Application 10569 No. and to conform to specifications and plans filed with said Application, and Building By- Laws of THE TOWN OF SOUTH WINDSOR. May 15 A, 7 Issue 19 Building Inspector. Streets and sidewalks, obstructed by excavations or building materials, must be guarded by barriers during the day and by both barriers and colored lights by night. SECTION 1343, GENERAL STATUTES OF CONNECTICUT: "When any person shall place or keep building materials, or any obstacle in any highway (or any sidewalk) either with or without a license therefor from the city or borough in which such highway may be situated, he shall pay said city, town or borough all costs and damages which it shall sustain, or be compelled to reason therefor." INSPECTIO REPORT Permit #Z 2�� 1 Footing 2 Foundation 3 Framing _ �- 4 Wiring 5 Plumbing6-( 1 6 Heating Cam_ [ C[T- 7 Lathing 8 C.O. �y _ — Permit No. TOWN OF SOUTH WINDSOR SOUTH WINDSOR, CONN. Permit CI 5141 Certificate of Occupancy T I INTO CE IFY that th T llf at N in the T of South Windsor, Connecticut, has been erected and comple in accordance with the Building Code and Zoning Regulations of the Town of South Windsor, and is hereby approved for occupancy. P-7 F/6'12�f f IF building nspec r weer, Builder - `t t Fee Paid i Date "" OZIS 119 's — EA09MENT RESERVED M OItAIN 10K I I.R N/F PATSY BREGLIO CONNECTICU'r / `0 LIGHT a POWER / c COMPANY o fig• a" 1 \ 107 _031.3711 \ 20' DRAINAGE RAW. Z38 TEST PIT ILI 0 LOT 15 / LOT 16 II v LOT 17 / N 5Is273.58 SQ.FT. !1 Lot information ernes from subdivision plan of Sand Hill it i ,r bb RAISED RA r,F �240'0 N Foundation located 5..06-78 No Zoning Regulations Violet d a I INSTALL. DIM INLET \ TIN nxe I I If FL 235.5 I W I �� • o v � c I IV o -�u ICAPKD 2'� ISAN.LAT a C RB + . As SOX x�4O'7 CARRIAGE DRIVESM _ S FT 3' ., '1Cxar- s , •" ROPERTY OR AU. TRACTORS ` AS afty E SOUT M MIYMmOR, CONIC ULJ -A CEK ASSOCIATES OAT CONSULTING ENGINEERS SCALE 1 = 40' DATE 6-14-TO S OAKLAND ROAD SOUTH WINDSOR. CONN. DRAWN A.V.H. CMMICM E.VLL, 203-944-2- PWJECT Te-44 OMW . CERTIFIED SUBSTANTIALLY CORRECT - p �R . ACCURACY• ' �•r Y T• Id 4 •� i h Y 3 EMANUEL W. LUCEK CONK. REG. L.A�1 $ Y Bi •`y. o"10 C_J-. ow r SIG.. LL- S- V., ftJ lo, �N����� -�v N/F PATSY 2.PLACE COMPACT 10 LAYERS CLEAN F� BANK RUN GRAVEL •, BREGLIO CONNECTICUT N LIGHT & POWER o COMPANY o � / y / / o s p , 5� 3 •• SOS. �� 5 p cyd` ZZ6 1 I ` Sewage system de tg�\is base d 'u orna, pro osed ee b- iroom home. Percolation 15 :min/ 33-\ 0"-60' SanJy Soil \� Grou?1d -dater at 30" 20' DRAINAGE 7 103� „ Min. Requirements \� R.O.W. � � 37 `-% \ 1000 Tank \ PIT 475 sq. . of eS ti leeching TEST \ \ ELEV.239. 3 trenches 36" �� '�W CO 230.2 75' lore j. INV.•2 35� \ \ The bottom of the system wi \ be 13" ab ve ground water. LOT 15 A2 �� �, LOT 16 j LOT 17 \� \ 51,273.58 SQ.,FT. � FL/ �: DS 241.45 0 � � r-, �- 11 1000 GAL. �� :> - 1 N % �' co, /l Lot l� �c _i on SEPTIC TANK FL CIP �� � ai # SubcLiv-ision Plan of 242.05 / °' j Sand N 1 1 \"� �,,.4,,.:, 55 N RAISED RANCH C F F GAR.240.0 N v GJ i in 1 N STAL L y DEEP n� 41.8' INLET ~ _- 3 / II TF 237.5 = �` 50� BUIL I G LINE j FL 235.6 f s No.6293 1 'Qc"gISTFRF-O rr� I DRIVE Z� ��Q�F. I CAPPED Q_ 22o-55 -06 1SAN. LATI -' - 130.01 • A- ., BOX x 240.0 x ''`� • 24O CARRIAGE DRIVE 2�0 - INrC 236.0�— atf'p -- C•-Joy \ lr�. - - _ - 240 _x `` TF 239.14 � �i�., �.,i E�.242.05 PROPERTY R.S.K. CONSTRACTORS INC. LOT 16 CARRIAGE DRIVE SOUTH WINDSOR, CONN. � EMIL W . LUCEI/ ASSOCIATES NO. REVISIONS DATE" SCALE 1°= 40' DATE 3_ 23-78 CONSULTING ENGINEERS A.V.H. CHECKED E.W.L. 5 OAKLAN ROAD DRAWN SOUTH WIND OR. CONN. 203-644 2v74' PROJECT 78-44 ;Y.EET CERTIFIED SU STANTIALLY ' CORRECT - DEGREE OF ACCURACY: P 629 /,�'2-- �� �, � f'"��'� �' ". •• � ' / EMANUEL W. LUCEK CONN. REG. LAND SURVEYOR _ ;,...: STANPAT PRODUCTS INC.PORT WASHINGTON.N.Y. 5/-�, R Q- V A --- N OF S ENC;tNEE O ��1P, �---- U)AT'E: r � MEMORANDUM July 20, 1978 To: J. E. Page, Town Engineer/Planner Re: Lot 16 - Carriage Drive Approval of a sewage disposal system designed by Emanuel Lucek dated 3/23/78 for the above lot was given by me on 5/3/78. Although the ground water observations made by the design engineer indicated water at 30" below ground level, the design was drawn to assume a ground water elevation at 1' below ground level. Through conversations with the builder and the design engineer, this assumed ground water elevation was recommended by Mr. Daniel Sevirio of the State Health Dept. My approval of the plan was based on these assumptions. After installation of the sewage disposal system, it was determined that the system was installed contrary to the approved design. This now puts the system in violation of the Public Health Code in regard to the required separating distances of the ground water table and bottom of the leaching system. In order to rectify this problem, the system would now have to be re-installed at a higher elevation and a pumping arrangement installed to meet the approved plan of design. It is the design engineers ' feeling that the system would not be in violation using his ground water observations. This is true, but I feel my approval was based on the assumption of a ground water table at a higher elevation. As a solution to this problem, I offer the following steps to be taken: 1. Install a perforated stand pipe adjacent to the leaching system to be used for future ground water observations. 2. Determine the ground water observations next spring between February 1 and May 1. 3. Determine the elevation of the presently installed system. 4. Retain a certified check in the amount of $2500.00 for a new sewage disposal system and pumping arrangement, if the present system is found to be in violation next spring. (See letter 7/14/78) 5. All elevations are to be mutually agreed upon by the Town Engineer and the design engineer. Final approval of the sewage system should be withheld until the above conditions are met; however, I will conditionally approve the installed system in order that a certificate of occupancy may be issued. C Richard B. Coppa ML Acting Director of Health cc: Mr. Kelley, Building Inspector, Emil Lucek f r Ca 0-1--- SOM& ?V • C � y ' ` 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CONN. 06074 e � OR-OD r AREA CODE 203/644-2511 -` July 14, 1978 Mr. Richard Kelley 49 Rosemary Lane South Windsor, Connecticut Dear Mr. Kelley: Re: Lot 16 - Carriage Drive An inspection of the sewage disposal system at the above location disclosed that the system does not conform to the design originally approved. It appears that the sewage disposal system is in the ground water and not the prescribed 18" above it. It will be necessary to now pump the effluent from the septic tank into a new leaching field placed 18" into the filled area. You are advised to submit an engineering plan to show the following design: 1. Place in series a new 750 - 1,000 gal. concrete septic tank to serve as a pump chamber. 2. Install a sewage pump in this chamber with a mercury float switch with 3 positions - 1) off; 2) on; 3) alarm; and a check valve. 3. Provide a distribution box with baffles. 4. Reinstall 225' of 3' wide trench at n0 greater depth than 18" into the filled material. 5. Extend filled area a minimum of 15' beyond any portion of the leaching system. 6. Set the pump to fill 75% of the pipe capacity in the leaching field.- 1 Mr. Richard Kelley Page Two July 14, 1978 I have had success with the Barnes Model SE 52 or the Goulds WP 0512S, single phase 220 volt pumps. I have also used the Als#4-1 alarm box with bell and light and the A1S2-3 mercury switch which are used with the Goulds pump. If you have any questions, or if I may be of any further help, do not hesitate to call me. Very truly yours, TOWN OF SOUTH WINDSOR Richard B. Coppa Acting Director of Health RBC/ml cc: D. McLaughlin J. E. Page 6484 ELECTRICAL APPLICATION Application No. 6790 on the side of Lot #16 Carriage Drive Street Street No. 118 Owner RSK Contrnchors Electrician Petersen Electric FILED IN OFFICE OF The Building Inspector June -.6 _ 19_7_$ INSPECTION. No Electrical Work shall be started until a Per. mit is granted by the Building Inspector. In New Buildings no wiring shall be started until the plumbing and heating pipes, and the fire stops (if of wood) are installed, without a special permit from the office of the Building Inspector. I APPLICATION FOR PERMIT TO DO ELECTRICAI. WORK. No. .....6..7-9.0.................. Permit No. ....64.$4..................... TO THE BUILDING INSPECTOR of the TOWN OF SOUTH WINDSOR, CONN. ... hereby make application tq perform Electr cal Work according to detailed description below. All pr visions of the Rules for Electrical Installation, Section 48, Building By-Laws, shall be complied with whether specified herein or not. �7 South Windsor, Conn., ........� 19.. Sign here C/`'' - .................. ......................... .............................. v� Address �.....�.... ....... . .....+C..�.......... .................. Location .....Gi� ........ .•............ .... .. Side of..... ........ .... .... .. . ....... ........................................................................................................ Natureof Building ................ ...... . How many stories ................................................................................................. 11 Newor old Building ...... .. . ........ ..... ........................ ... ....... .. How many families ............................................................................................... W.07 Kindof Installation ..... ? ....... .......... .............. How many Stores ...................................................................................................... Owner ./1.... .....0 .0.. ............................__.............. Address ........................................... Q _......_...._...... Architect .................. .......... .......... ......... .. .. ...... ................ Address ..... ................................................................................... _...__....._....._._.... Builder 0 . ........ Address .. . . . . ........ ... ...................................................._._._........_........... ��.?..� .. ...................... ........ Electrician ...A ... ....... .. ... Address �.n., ....... _...._..........._....�...... v� Size of Main Wires ........................................................_ . No. of Heat Loops ......... No. of Power Loops ..................................._.... No. of Light Loops .. ........ .../ No. of Light Outlets .....�.r�. . No. of Heat Outlets ... No. of Power Outlets ................... ............. NoP of Light Circuits .... ....6. ......... ..... No. of Heat Circuits . .... No. of Power Circuits .. ............ ......... ...... No. of Sockets ........ .. . .. ... .. ..... . No. of Heat Receptacles No. of Motors ................. .... ........................ No. of Panels ........................ ...... ...... Size of Heat Circuit No. of Power Receptacles ...................... No. of Switches .......... ....... .. . Total Wattage .............................. ....... ..... .... Size of Power Circuit ... ... ..... . ........... Total Horsepower ... ....... . ........ No. of Straight Electric Fixtures ... . ... No. of Combination Fixtures ..... ..... ..... ................ ... ............. No. of Receptacles .......... .7.......... ......... ............... . No. of Cord Drops ...... ............................................................................... Remarks: For other kind of Installation . ............. ..... .. ..... ....... .. ... ...... .... ............................. ..........C�c.1 .... ....................,,......... .. j...... ... f........ ................. ...... ........ ....... . ....... ........................................... _... .......................... ........................................................................... ...................... ...... .... ..................................................................... .............. .. .... . ............................ ......... ................... ............................... ....... ........... . ..... ...... ......... ................... Estimated Cost .... ... ......06................. 5209 PLUMBING APPLICATION App �No. 5995 on the Side of (118) Plumber .Ye.1 �..- Filed in Office of The _ j nP 14 19. 79 II�T�Cl'101r. No person shall eomtrw:r, add m or alter arty portion of the drainage system of my buiLliag (except to repair Deal) until a Pe grayed by the Building Inspeoaor. 5995 5209 ApplicationNo. .......................................... Permit No. ...................................... TO THE BUILDING INSPECTOR of the TOWN OF SOUTH WINDSOR, CONN. .... ....hereby make application to perform plumbing according to detailed description below. All provisions of the Rules for Sanitation, By-Laws, Sections 33 to 47 inclusive, shall be complied with whether specified herein or not. South Windsor, ..........................4--.10....... ........ 19 ... Sign here ... ........ .. ...... .................. ... .... .... . ..... . 4- Address I. .?..... Location .........................10.404.z.pi................................................................. side of ... .....0...... ... . ......................... Street es ......................I........................................ ................................ How man t .............49*3 Nature of Building Owner ...--kU-e..... �........................................ Address .: ................................................. Architect ....... ..... ..................................................................................... Address ......................................................................................................................- Budder ..................... .......... ........................ Address ...................................................................................................................... Plumber— �- Address .... ..................................................................... DRAINAGE CESSPOOLS, How many ............../......................... .................. Where located ..... ............................................................................ Are they water tight .......... ............................................ Of what materials are they built ..... .............. Size of pipe from house to cesspool . .................. ........................ Kind of pipe ....4609( 00... ................................................. MAIN DRAIN IN CELLAR, Material -1. 'n.................................................................................. Diameter ......... d ........ .. ............................................................. . Above or below cellar bottom .. ...................................................................... SOIL PIPES, Material ..................... Diameter .........q.......3'.f.............................................................................. WASTE PIPES, Material ...... ........... ............... Diameter ......3... ...�J............................................................ TRAPS,Type proposed to use is ..................................Ir-T. .. ......................................................................................................................................... RAIN WATER LEADERS, where do they run to .......77=7=.................................................................................................................... REFRIGERATOR WASTES, where do they run to .. ......... ............................................................................................... ............................... TANK OVERFLOWS, where do they run to . . .......................................................................................................................... FIXTURES WATERCLOSETS, How many . ................4,P'L...................... Where located .... .. .. .................................................................................. Distance from trap to vertical soil pipe ................................... Pattern . .................. .................................................................. WASHTRAYS, How many .......................................................... Where located . .................................... .................................................. SINKS, How many ...............................................z..................................... Where located ................................................... BUTLER'S SINKS, How many ............................................ Where located. .................................................................................................. REFRIGERATOR SINKS, How many.................................. Where located ................................................................................................... LAVATORIES,How many ............................................................... Where located ..................................................................................................... BATH TUBS,How many..................................!A.............................. Where located .....C.....(....... %....... ......................................... URINALS, How many .............................................6................................ Where located .................................................................................................... Are water closets and urinals to be local vented if not, is there a window in outer wall ofroom where same are to be located ...... . . ............................................................................................................................................ Estimated Cost..d-3-4A-0.........0...d............ PERMIT # Application For 5004 4803 IV 65 DEPARTMENT DECISION Heating Permit � o 3 APPLICATION IS HEREBY: DEPARTMENT OF LICENSES AND INSPECTIONS N 11 APPROVED ❑ DISAPPROVftq TOWN OF SOUTH WINDSOR 0 cc 0000 y DA IEF INSPECTOR APPLICATIONS MUST of PRINTED OR TYPED.114179 /1-611LZ BEGIN WITH NUMBER ONE sEL N O 1. LOCATION OF JOB 118 NO. STREET Oco 14 � v v1 LOT NO. FLOOR APT. NO. � N o Z. OWNER Q � c o f. ADDRESS SuJ 4.PHONE � D I APPUCANT as a~d p s. ADDRESS Pa 7.PHONE 219P s. LICENSE NO. t. EXPIRATION DATE OF LICENSE e� 10. ESTIMATED COST $—A-4al-0 ' 11. IS THIS A CONTRACT COSTT AYES ❑ NO b0 P 12. FEE ENCLOSED S - rmit 410269 Xis. TYPE OF BUILDING: en RESIDENTIAL ❑ COMMERCIAL ❑ INDUSTRIAL y 14. TYPE F JOB: cc 3 RIGINAL ALTERATION INSTALLATION ❑ ADDITION REPAIR I APPLICATION FOR HEATING PERMIT (Continued it m R verse side) 1� 11. LOCATION OF JOB 4�4 f NO. STRrt FLOOR AFT.NO. 12. TYPE OF INSTALLATION; OIL BURNER ❑ ELECTRIC ❑ VENTILATION ❑ SPRINKLER ❑ GAS BURNER ❑ STACK ❑ INCINERATOR ❑ MISCELLANEOUS IDENTIFY SIZE LOCATION SIZE 1. SIZE 13. OF TANK - _t� OF TANK ���f OF FILL t OF VENT 14. B.T.U. EQUIP. AT REGISTER FURNACE MAKE AND NO. ��������AT BONNET FIRING RATE BOILER OR FURNACE MAKE AND 005'roB.T.U. OR SQ. FT. NETAVM.A.T.U. OR SQ. FT. GROSS FIRING RATE FLOORS TO BE HEA ED NEW OR OLD BUILDING NSULATED - YES OR NO Cl TYPE OF WALL INSUPON ROOF OR CEILING �►L ems INSULATION — d4eQ AVG. SYSTEM W ER TEMP. .U./SQ. FT./HR. EMISSION INDOOR-OUTDOOR TEMPERATURE DIFFERENCE ea °FAHRENHEIT MAKE OF RADIATION: BASEBOARD. COPPER CONVECTORS. OR C.I. RADIATION. UTPUT PER SECTION OR LINEAL OF RADIATION. SQ. FT. OR B.T.U. /S v DESCRIPTION OF W K 15. TO BE DONE; IV 16. HEAT LOSS SCHEDULE. (TO BE INCLUDED FOR ALL JOBS); Ro M Slz! WIND INS AREA - SQUARE FEET e.T.U. T.U. F D AND 000Rs VOLUME c DISTRIBUTION INSTALLED TOTAL TOTAL R OM NO. GROSS GLASS NET WALL CEILING FLOOR CU. AT 70•F CORRECTED t j REGISTER L w M AND C WALL t (INFILT.) TEMP. TO F F 0 TYPE AND SIZE RAD' R LEADER SIZE < ��Y / �a DIFF. •F FO m�n SO' FT' FREE AREA -13-31 fr liv q!7! 3 s!U 17 xa 3 d B Nov d �1�o' ry v �. rmr 4 2o� 161fv l rrov 3 3 3d �o&� i33uv �� , •, / TOTALS A. HEAT LOSS FROM BUILDING ��90 O B.T.U./HR. B. DOMESTIC HOT WATER DEMAND- V ® B.T.U./HR. C. PIPING. OTHER THAN NORMAL B.T.U./HR. ALLOWANCE FOR HEAT VALVE OF FUEL (A B C) FACTOR .5 17. ELECTRICAL WORK BY: ' C ' NAME ADDRESS SUBCONTRACTORS AND 1a. THEIR TRADES 'lYl�LLD All WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE(OWNER) OR (AGENT) OF THIS PROPERTY AND WILL BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE. APPLICATION TO BE COMPLETELY FILLED IN. DATE III N TURF OF APPLICANT . g0� t TO THE BUILDING INSPEMR • 411 do APPLICATION FOR . or � PLAN EXAMINATION AND BUILDING PERMIT ISMOffNM• Awheeut Ir eo"lote e11 iftss in "Wens: 1, 11, I11, IV, OW IX. l/ i4r2t2i/�t' � OISTRe • AT (LOCATION) ime., `sT�1 � oIiTRICT�_ LOCATION .. ��1�C�-7—U✓c� ��rO OF wrwssp —/lJ✓�? U i ENO BUILDING (C*"$Met?) 4"mess s♦104 I su�olVlilpl LOTS KOCK slu � �- 11. TYPE ANO COST OF BUILDING — All applicants compleft Parts A — D A. TYPE of IMPROVEMENT 0. PROPOSE* use - far"Wraww •'~t resent use 1 ❑ 14w bodying Residential Nettwsidewtial 2❑ Addition(If nendewtial. ewte►mnswbe► t2 1R Anvoomem. rectootienel /weer beanog wars wed. i/my. 12 l:=i"IV Ewter 19 Clwtsb.edge.religiousiw Part D. /3) mvo/susits— — — —i—r 3❑ Altatatlaw (Sri 2 abeve) CM 10600101 1 Repair, 14❑ Transient hetsl,metal. r cmPeibiwg verve" a epai , maleceimewt or do""" — ewer nsmber S❑ Wracilot I 1/matti/mlay residmaidt. Of waits ——————— —♦ ❑ Sevvie"Stamen. repair taro" eater ssmwber o/oats w bailmom in Is❑ GMage b❑Mespital, inotitwmesw Part D. 1!) Is❑ Carport 24❑ Office.boob. professional i❑ IMeving (relocation) S/ee:/y A&tro 6iQWA-4 2S❑ Pubus utility 7❑ fsowtdetiew only 11 r p� 25❑ Soboel, library. other edwotlowoi R. OWNERSHIP d [� /O 33 27❑ stares. aersesmI Pri sate(i,tdividual, •sr,sr ti.w. A❑ Teobs. femet nenorefit 1419t40IM--m.*^'Z.) 29❑ OMar - speci/y 9 ❑ Public(federal, Sate. or local government) C. COST (Amnt cowls) Hewressdeotial - Describe in detail proposed use of buildings.e.g.. food Cie, processing view.. machine shoe. laundry building of hospital. 16061 tery 10. C Of of imprevement............... �r school, seewWwy sabool. college. perechiel'schoel. parking geregs for demo! men stem, nwtal office bolding, efflse building of industriol plant. T be instaNler bat not twcla/ed If use of*misting building is bung shawged. enter proposed we in tube above cost �C7 is. Electrical...................... Is. Plumbing ...................... ` W.Meeting, air conditioning......... �. rJCbar(clevator. oft.)............. t 1. T TACOST OF IMPROVEMENT 107 III. SELECTED CHARACTERISTICS OF BUILDING — For now buildings and additions, cmplet* Ports E — L; for wrecking, complete only Port J, for all otters skip to IV. E. PRINCIPAL TYPE OF FRAME G. TYPE OF SEWAGE DISPOSAL J. DIMENSIONS SO`J Mosemy(melt bowing) 40 Public or private saany r• Number of stenos................ 31 ❑ wand fre,eo 41 S mtp Privets(secede sawb. Na.) As. Total square lost of floor ore". oll floors. based on exterior U❑ Structural steel diaewsions ..................... 3❑ Reinforcer sewer.+. H. TYPE OF WATER SUPPLY ail O*w S i 42 Public or private company �• Total lewd ores, $q. N. ........... 42❑ Privete(.all, sissorw) K. NUMeeR OF OFF-STREET PARKING SPACES P. PRINCIPAL TYPE OF HEATING FUEL I. TYPE OF MECHANICAL st• lnsissed ....................... 36❑ Gies 11111 Mare be coastal sit SL Outdoors........................ m❑ Oil saodltiowims? L. RESIOEIJTIAL •UILOINGS ONLY 37❑ swomsity Y❑ Yes 40❑ N �. Numnb"r ei berrloo"s.............. s❑ cow Sf❑ OMtar- SMci/y 111111 Mara be at siovetof? Full.......... !R. Naeber of dR 0 Yea 47❑N. b''"""• P.rt1a1........ IV. IDENTIFICATION — T be canploted br oil applicants Name Meiling address — Number. strret. c:t-v. and Stste ZIP cod Tel. Ne. Lessee 2. 3. A•ehreet e► En�nee. Th owner this building and the uniarsigned agree to conform to all applicable lows of this jurisdiction. 19netur pplicen �.' Address Application dote s ; r 00 NOT WRITE BELOW THIS LINE V. PLAN REVIEW RECORD — For office use Plans R view Required Check Plan FeeReview S Started By Ate Plans gy Notes ppreved BUILDING S PLUMBING S MECHANICAL S ELECTRICAL S OTHER S VI. ADDITIONAL PERMITS REQUIRED OR OTHER JURISDICTION APPROVALS ole Perri, or Approval Check ObO+e nod Number By Permit or Approval Check{ OtrOa r,♦d � Numb r 3-4 BOILER PLUMBING CURB OR SIDEWALK CUT ROOFING ELEVATOR SEWER ELECTRICAL SIGN OR BILLBOARD FURNACE STREET GRADES GRADING USE OF PUBLIC AREAS OIL BURNER WRECKING OTHER OTHER i 11. VALIDATION Building l� �f� P rmit numb r / 6 `y' Bui Iding �J�� 19 P rmit issu d / Bui Iding �9 p P rmit Fe S A10 v d,by: TITLE A TOWN OF SOUTH WINDSOR BUILDING PERMIT Date 4/22 19 88 Fee Paid $.1.8..0 0 Eat. Value $. .2 9r.4 7 Permit N2 16644 on the aide of Carriage Drive Street Street No. 1 1 R Owner Marc Coleman Applicant S am CERTIFICATE OF OCCUPANCY ISSUED: Date No. Fee Paid $ CLASSIFICATION Pool --AhQVQ round BLTUDiNG PERMrr N o 16644 OFFICE OF THE BUILDING INSPECTOR of the Town of South Windsor, Conn. South Windsor, Conn. 4/2 2 1988 454is is to (ferttfg, That( Pool,amn Pools 1 Adair% Ca?eman is hereby granted permission to in s t a 1.1 a r. abo wu around pool at estimated value of on the side of 118 Ca rr i!,ar, Tyr ye Street on land owned by :-;,:ro Co 7_nn asp' Said NO-rk to be as described in Application No.1 aa and to conform to specifications and plans filed with said Application, and Building By. Laws of THE TOWN OF SOUTH WINDSOR. Issued 4 22 M8 8 Building Inspector. i Streets and sidewalks, obstructed by excavations or building materials, must be guarded by barriers during the day and by both barriers and colored lights by night. SECTION 1343, GENERAL STATUTES OF CONNECTICUT: `When any person shall place or keep building materials, or any obstacle in any highway (or any sidewalk) either with or without a licen;* 'therefor from the city or borough in which such highway may be situated, he shall pay said city, tows or orough all costs and damages which it shall sustain, or be compelled to reason therefor." 1 i l c i 121966 N/ F CONNECTICUT LIGHT a N/F POWER COMPANY 2 25.03 � BREGLIO '• \ EASEMENT RESERVED FOR DRAINAGE 20 50' REAR YARD Q �O Qr & co LO T 16 ~ O VOL 246 PG 44 LOT 15 N N �w N STq RS ° k � c ss' Po 32� NOIJ Q` 20' DRAINAGE R.O.W. �(b.. Q ST£ PA co Wq Sp PS �k (D �O Nc LO T 17 � NF � � 4 30�O� o� LEGEND BIT BITUMINOUS N Q C CONC. CONCRETE q RR 0.H. OVERHANG q G� C CHIMNEY \ SUBJECT TO C L Ek P Fo ` EASEMENT V.172, P106 GF F e�T C� Re THIS MAP IS COMPILED FROM OTHER MAPS, DEED DIMEW SIONS AND OTHER SOURCES OF INFORMATION, NOT TO BE ' CONSTRUED AS AN ACCURATE SURVEY AND SUBJECT TO FINAL CHANGES AS A MORE ACCURATE SURVEY MAY 00% DISCLOSE, V, ELEGTRIUL AMIGATM Application No. on the eiae�f LqA(-'� R I_A G� Sant Strut No. /fig Owncr A b�E/�'114�✓ Ekctricisn M A RC ( ij t E-07 q N FILED IN OFFICE OF The Builder Itrpector 19 R8— Irlsre CTION. sw No Electrical Work shall be started until a Per- mit is granted by the Building Inspector. In New Buildings no wiring shall be started until the plumbing and heating plpes, and the At+e stops fit of wood) are Installed, without a special permit from the otlice of the Building Inspector. Electrical Permit Mm --- J 4 22 y Master License No. c2woL-CIN TOWN OF SOUTH WINDSOR Building Permit N BUILDING DEPARTMENT Date Filed Date Final Approval ........ .............. APPLICATION FOR ELECTRICAL WORK Electrical Inspector OB LOCATION: Ain... Lf—JOB, OWNER: ............. ...... Side of ... 0 T.1.5.......................................... . Between .......1-.V_>7-.Z..2............................................ and Name of Building ................ Address If work is for Lessee—Give name ...._.................................. ...........................- Address Building now occupied as (unless new) ................... No. of family nails now Building to be occupied as ......................... ................_ Number of family units to be Is this work included in a Building Permit? ........ ........ Permit Fee (If no B-1-6 Permit) Permittee 1.&xell ............................................ Business A J.J iress, . !ALL,�I_ Telephone-�__Q,I f/.2&..4 phow Z LZI -------------- ------ COST OF INSTALLATION: TO BE FILLED OUT BY PERMITTEE TO BE WIRED EXISTING APPLIANCES Number of light outlets to be installed ...................... Numb r of convenience outlets to be installed ..... .......... .. .. Number of present Appliance Circuits, Number of switches to be installed . . . ...... ....... ........ Do these include Range ❑ Water Heater ❑ Number of appliances to be installed . . . ............................ (as listed below) Dryer C] Air Conditioner ❑ Oil Burner ❑ TYPE RATING NO. Dish Washer [3 Gas Burner [3 Range . . . . . . . . Well Pump ❑ Mec. Heaters [3 Range Top . . . . . . Oven . . . . . . . . REMARKS: Water Heater Clothes Washer . . . . Clothes Dryer . . . . . Dish Washer . . . . . . Air Conditioning Motor . . CHI Burner Motor . . . . Gas Burner . . . . . . Circulator Motor . . . . Attic or Large Fan . . . Well Pump . . . . . . Electric Heat . . . . . Other . . . . . . . . .. Number of new Lighting Circuits Number of new Appliance Circuits Number of Heating Circuits Number of Motor Circuits . . . . . . . Size f present service Size of service to be FINAL INSp C O Building g J� APPUCATION FOR BUILDING PERMIT Plumbing Date: HVAC 118 CARRIAGE DRIVE Sprinkler Electric Estimated Cost $ D D Zoning 2 2 0 9 2 Permit Fee$ Affidavit NO. Occupancy Fee $ Eng. D pt. COMPLETE RED BOXED AREAS. D!J Fire D pt. TYPE OR PRINT ONLY Total Fee $ Mt Health Dept. SIGN ON REVERSE SIDE. Approved for CO: - (Additional Cost) _ TO BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT The undersigned he by lies to do work cording to the following specifications: Job Location Lot No. Side of Street Zone Applicant / � lAEieTel. # - / Address /-ZO 9 •Sully Ste. Zip 4 Lic.# EETT CITY STAT OwnerG�l�.o� Address Architect Address Size New Area: Ft. Front Overall Ft. Deep Overall Total Area #Garages Size of Lot Dist. from Street Line Lavatories Bathrooms Rooms 1 st 2nd 3rd Purpose of this Permit '��O i City Water O Well 0 Septic 0 Sewer 0 Use Group P Construction Type /v Approved by J Date BD1A 11/88 I h reby agree to conform to all the requirements of the Laws of th State of Connecticut and the Ordinanc s of th Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard line nd required distances from all other zones and is located in a zone in which this building and its use is allowed. S Signed r I hereby apply for a Certificate of Occupancy for the work described in this application for permit. Signed —DO NOT WRITE BELOW THIS LINE— INSPECTION RECORD Footing Framing Foundation Fireplace/Chimney Insulation Plumbing Permit# inspections: HVAC Permit# Inspections: Electrical Permit# Inspections: Sprinkler Permit# Inspections: FINAL INSPECT APPLICATION FOR BUILDING PERMIT Builbing Plumbi Date: HVA 118 CARRIAGE DRIVE Sprinkler For Electric Estimated Cost ; Permit Fee; Zoning NO. 22091 Affidavit Occupancy Fee; Eng. D pt. COMPLETE RED BOXED AREAS. Fir D t. Total Fee p TYPE OR PRINT ONLY Health Dept. SIGN ON REVERSE SIDE. AppmmW for CO: - (Additional Cost) ; TO BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT The and reign , hereb_y plies to do work according to the following specifications: Job Location - Lot No. Side of Street rlZone� Applicant �• '��� Tel. #&-W-260� Address v�l r Zip -�Aiy Lic.# S CITY ATE Owner ddress • Architect Address Size New Area: Ft. Front Overall Ft. Deep Overall Lotal Area #Garages Size of Lot Dist. from Street Line Ba hrooms Rooms 1st 2nd 3rd Purpose of this Permit ioA _,"le City Water 0 Well 0 Septic 0 Sewer 0 Use Group wvr Construction Type U Date BD1A 11/88 Approved by - I h reby agree to contorm to all the requirements of the Laws of th State of Conn cticut and th Ordinances of th Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yar i s and required distances from allot er zones and is located in a zone in which this building and its use is allowed. Signed I hereby apply for a Certificate of Occupancy for the work described in t applic ion for permit. Signed —DO NOT WRITE BELOW THIS LINE— INSPECTION RECORD Footing Framing Foundation Fireplace/Chimney Insulation Plumbing Permit# Inspections: HVAC Permit# Inspections: Electrical Permit# Inspections: Sprinkler Permit# Inspections: INSPECTOR !'� DATE + TIME LOCATION INSPECTION: CODE: RESULT(D/A) : � BUILDING: ELECTRICAL: PLUMBING: F HVAC: OTHER: ��� 3 7 L4