Loading...
HomeMy WebLinkAbout125 Cambridge Drive e q ' TOT BU11DING INSPECTOR Of the APPLICATION FOR TOWN OF SOUTH WUrDSOii,COWL, PLAN EXAMINATION A N D BUILDING PERMIT z IMPORTANT — Applicant to complete all items in sections: 1, 11, 111, 1V, and IX. O I• AT (LOCATION) ZONING AA-3DISTRICT LOCATION (NO.) (STREET) OF BETWEEN /T/U / AND BUILDING (CROSS STREET) V (CROSS STREET) SUBDIVISION CAMBRIDGE ESTATES LOT BLOCK SIZE II. TYPE AND COST OF BUILDING — All applicants complete farts A — D �o A. TYPE OF IMPROVEMENT D. PROPOSED 14SE — For"Wrecking" most recent use rn rn 1 New building Residential Nonresidential 2❑ Addition(11 residential, enter number 12 ne family 18 Amusement, recreati nal nowhousing units added, i/any, in Par 13ETwo or more family — Enter 19❑❑ Church, other religious in Part D, 13) number o/units— — — ——► 20 E] Industrial3 Alteration (See 2 above) 14❑ Transient hotel, motel, 21 ❑ Parkin 4❑ Repair, replacement g garage P . P or dormitory — Enter number 5❑ Wrecking (it multifamily residential, of units ——————— —-i 22❑ Service station, repair 9orag enter number o/units in building in 15❑ Garage 23❑ Hospital, institutional Part D, 13) 16❑ Carport 24❑ Office, bank, professional 6❑ Moving (relocation) 17❑ Other — Specify 25❑ Public utility 7 ❑ Foundation only 26❑ School, library, other educational B. OWNERSHIP 27❑ Stores, mercantile 8 Private (individual, corporation, ' 2B❑ Tanks, towers nonprofit institution,etc.) 4 29❑ Other — Specify 9 ❑ Public(Federal, State, or I Cal government) C. COST (Omit cents) Nonresidential — Describe in detail proposed use of buildings,e.g., (o d processing plant, machine shop, laundry building at hospital,elementary 10. Cost of improvement................ 0 C9 Q school; secondary school, college, parochial school, parking garage for, department store, rental office building, office building at industrial plant. To be installed but not included If use of existing building is being changed, enter proposed use. in the above cost a. Electrical...................... b. Plumbing ...................... t c.Heating, air conditioning......... d. Other(elevator, etc.)............. 11. TOTAL COST OF IMPROVEMENT 3 O' III. SELECTED CHARACTERISTICS OF BUILDING — For new buildings and additions, complete Parts E — L; for wrecking, complete only Part J, for all others skip to IV. E. PRINCIPAL TYPE OF FRAME G. TYPE OF SEWAGE DISPOSAL J. DIMENSIONS 30❑Mos my(wall bearing) 40� Public or private company 48. Number of stories................ 31 W d frame 41 Private (septic tank, etc.) 49• Total square feet of floor area, all floors, based on exterior ^70 32 Structural steel dimensions ..................... O 33❑ Reinf rced concrete H. TYPE OF WATER SUPPLY 34❑ Other — Specify 42R Public or private company `50• Total land area, sq.ft. ........... 43 Private(well, cistern) K. NUMBER OF OFF-STREET PARKING SPACES F. PRINCIPAL TYPE OF HEATING FUEL 1. TYPE OF MECHANICAL 51. Enclosed ....................... 35,1 gLGas Will there be central air 52. Outdoors....9................... 96❑ Oil conditioning? L. RESIDENTIAL BUILDINGS ONLY 37❑ Electricity 44❑ Yes 45❑ No 53. Number f bedrooms.............. 36❑ Coal 39❑ Oth r— Specify Will there be an eI valor? Full.......... 54. Number of 46❑ Yes 47❑ No bathrooms Porti a l........ IV. IDENTIFICATION — To b completed by all applicants Nome Mailing address — Number, street, city, and State ZIP code T I. N Miller Realty Inc . 658 Ellington Rd . So . Windsor , Ct . 06074 282-0628 Owner or Lessee Z. Same Same Contractor 3. Architect or Engineer The owner of this building and the undersigned agrge to conform to all applicable laws of this jurisdiction. Sign ture of applicant AdJress Applic lion date 8 DO NOT WRITE BELOW THIS LINE V. PLAN REVIEW RECORD — For office use Plans Review Required Check Plan Review Date Plans B Date Plans 8 Notes 9 Fee Started y Approved y BUILDING $ PLUMBING $ MECHANICAL $ ELECTRICAL , $ OTHER Is VI. ADDITIONAL PERMITS REQUIRED OR OTHER JURISDICTION APPROVALS Permit r Approval Check Date NumberNumber By Permit or Approval Check ObDroined Number By BOILER PLUMBING CURB OR SIDEWALK CUT ROOFING ELEVATOR SEWER ELECTRICAL SIGN OR BILLBOARD FURNACE STREET GRADES GRADING USE OF PUBLIC AREAS OIL BURNER WRECKING OTHER OTHER VII. VALIDATION Building /� �L' P rmit number Bui Iding P rmit issued 7 19 Bui Iding 00 P rmit Fe $ �r °O �. o , A, rov ed fb r � 1 TITLE A TOWN OF SOUTH WIMSOR BUILDING PERFAU Date 10/07 , 1987 Fee Paid $5T$40 Em Value $16.1.400 Permit N° 16307 on the side of CtbrLdgee DrLy Street Street Nowt Z I►--A1$3 Owner I ler Ron lty,. Ina. Applicant Santa CERTIFICATE OF OCCUPANCY ISSUED: Date No.$352 Fee Paid CLASSIFICATION Dwelling BU`HDj NG PBRMIT N° 1630'7 OFFICE OF THE BUILDING INSPECTOR of the Town of South Windsor, Conn. South Windsor, Conn. 10/0 7 1987 94is 'to to Ciertify, That Miller Realty, Inc. is hereby granted permission to Au-i I d a s ing I e f am i 1 y dwe 11 i n� at estimated value of $ 9 6 ,0 0 0 on the side of Lo t l l ——12 5 Cambridge Drive Stet on land owned by Same as above Said work to be as described in Application No. 16 6 0 5 and to conform to specifications and plans filed with said Application, and Building By- Laws of THE TOWN OF SOUTH WINDSOR. Iss 10107 1987 Building Inspector. Streets and sidewalks, obstructed by excavations or building materials, must be guarded by barriers during the day and by both barriers and colored lights by night. SECTION 1343, GENERAL STATUTES OF CONNECTICUT: "When any person shall place or keep building materials, or any obstacle in any highway (or any sidewalk) either with or without a license therefor from the city or borough in which such highway may be situated, he shall pay said city, town or borough all costs and damages which it shall sustain, or be compelled to reason therefor." �V1-71j?7 INSPECTION REPORT Permit # /A 3,0 7 Job�ei i/ /.�5 KAmRR VQ D0C 1 Footing 2 Foundation . 3 Framing 4 Wiring 1D0 1 I CtIA -'j/ -V-- ' 5 Plumbing �� '� �� 6 Heating o3' E/V y)Ro 7 Lathing s C.o. DWELL�N� C�RM6RiE�ST. /D/71$7 la?.S��m 8R /Y) �L��lezoi-r y r,Jc. Perini t # 3d 7 Electrician�►CNQRiJ �AR�ETi #/ooa/ " Heating Contr. ENVIRO-icy # 7054.1 Plumbing ��'�Q. I4I.Sok FL54HTG # 44 Oil Burner # Certificate of Occupancy �l�b(9a # Z35Y Sewer Permit H WINDSOR TOWN OF SOUTH CONN. Permit No. SOUTH WINDSOR, Permit N� 8359 Certifi to of Occupancy j e South Windsor, Connecti t, has I TO CERTIF a th in a Town of So Regulations 01 T Code and Zoning rdance with the Building at No leted in ac roved for o anc . I been erected and comp and is hereby approved the Town of South Windsor, Spector I ui ing I I,I ner, Buil r � �G �I 0-1Date �9 9(L Fee Pai ' µ1 CERTIFICATE OF OCCUPANCY CHECK LIST Applicant Miller Realty Certificate of Occupancy Fff-19 658 Ellington Road Bldg. Permit No. /�e_�1 Lot No• #11,- 125 Cambridge Dr. Date Submitted 8- 1-8 9 Project Cambridge Estates Reviewed By Date loft tifica e-of-occu-occupancy As required in the Zoning Regulations, no cer P shall be issued until grading plans have been complied with and approved by the Town Engineer. The minimum requirements shall inlcude: Approved Denied N/A 1. Approved building permit plan. 2. Finish grading per approved building permit plan. 3 . Site work; i.e. trees, shrubs, dumpster required parking 4. Utility location a. sanitary sewer b. foundation drain c. electrical & telephone d. water e. other 5 . Appropriate certification 6. Bonding Sewer Permit No. Pavement Excay . No. COMMENTS : tj 7Zc Aouse. fs Cyr 2. s I � h c1 �x 60 or► yr .�. �h ' - tSUlLUl1Vl= YL•�1tMl'1' l:rir;l:n Llb'1' Applicant Building Permit No.,- Address Date Submitted Lot No. // Reviewed by Project Gr3r2I(7G4 r^sF-7 7-r--FS Date /; is In accordance with the Subdivision Regulations, prior to the building of any structure on a lot, a Topographic Plot Plan shall be submitted for approval. The minimum requirements shall include : Approved Denied N/A r� 1. Name, address & phone number of owner/ applicant. 2. Name, address & phone number of plan preparer. 3. Zoning information - i.e. zone, open space, / floodway, etc. (/ 4 . Plot plan at 1" = 40' scale. a. Subdivision reference, abutting properties, etc. b. Easements of record. c. Lot description, bearings, distances , building lines, area, etc. d. Contours, existing & proposed, 1 or 2 ft. interval where appropriate. e. Building location with dimensions. Elevations of proposed finish floor, garage floor & center line of road at / driveway. r/ f. Elevations of gravity drainage systems, '- sanitary & foundation drain at the house and the street. g. Tentative utility location gas, electric , water, etc. h. Title block with name and address of preparer, date appropriate certification, live seal and signature. 5. Sedimentation and erosion control. 6 . Special Planning & Zoning, Inland/Wetlands considerations. (Plans on file w/Town Clerk) BUILDING DEPT. P ZC IWA/CC WPCA / OTHERS COMMENTS: ELEGTRICAL APPLICATIN Application No. an tie sick•E Street No. �1 Owner 61YS l'� l)�l Ekctn�iciaa c1 J9 I-) RE-7 FILED IN OFFICE OF The Building Impectw INBliC7'IObi. e+No Electrical Work shall be started until a Per. mit is granted by the Building Inspector. In New Buildings no wiring shall be started until the plumbing and beating pipe* and the An stops lit of wood) are installed, without a special permit from the odlee of the Building Inspector. Electrical Permit Na / • Master License No. Lq � D'1 TOWN OF SOUTH WINDSOR Building Permit No. !L Date Filed ...... ..10 BUILDING DEPARTMENT Date Final Approval APPLICATION FOR ELECTRICAL WORK Electrical Inspector CC) B O►B LO (;��TION: to�. .._..... -. .. ...-. J �.Cie. Side of .. .. Q........................ Be weep .... . ._... ...._......_...-. ..... and _w.. ..-....�C�........--....____ Address .._. ...r....l�.. .�C.+�.....-.....� _ ._- Name of Building Owner ........ . _.. .. . If work is for Lessee—Give name ..�.._.�....... •-- -.. --.-......---.- Address Building now occupied as (unless new) ..-.... �-�;`� ....... ----.- No. of family units now _._....-_.-...� Building to be occupied as _..w.�._..--.-.-. . •-•--. ---•. .. .....---•-. Number of family units to be .._...._.�..�___-._ Is this work included ' a Building Permit? ...� ..•._... Permit Fee .._ (If no B ~Permit) 7> Permittee i- .. ..... .......•-... ...--...- Business Address . . .... TeleplLone '"'�J COST OF INSTALLATION: TO BE FILLED OUT BY PERMIT TEE TO BE WIRED 4 EXISTING APPLIANCES Number of light outlets to be installed ... . ... _...... Number of c nventence outlets to be installed ..•... -•-... .. Number of present Appliance Circuits .....•... - Number of switches to be installed . . . - Do these include Range ❑ Water Heater ❑ Number of appliances to be installed . . -.--- (as listed below) Dryer ❑ Air Conditioner ❑ Oil Burner ❑ TYPE RATING NO. Dish Washer ❑ Gas Burner ❑ Range • • • ' ' ' ' ' Well Pump ❑ Elec. Heaters ❑ Range Top . . . . . . Oven . . . . . . . . c Water Heater . . S O r Clothes Washer . . . .th s Dryer . . . . . 1 VEC clo a Dry � Dish Washer . . . . . • . Air Conditioning Motor . Oil Burner Motor . Gas Burner . . . . . . Circulator Motor . . . . Attic or Large Fan , , Well Pump . . . . . . Electric Heat . . . . . Other . . . . . . . Number of new Lighting Circuits - Number of new Appliance Circuits . . . Number of Heating Circuits • Number of M t r Circuits . ----- Size f present service .�--.--•--- Size of service to be . PERMIT N0, A 8 DEPARTMENT DECISION APPLI CATION FOR Application is hereby:A p p •y • PLUMBING PERMIT TOWM OF SOUTH WINDSOR APPROVED DISAPPROVED BUILDING INSPECTION DEPT. �Z 644-2511 Ext. 230 Date Bu d ng Inspector Application must be printed or typed. 1. LOCATION OF JOB �25" FEE SCHEDULE 2. OWNER: 3. ADDRESS: ��� ��•i c �r ��, $ 0 - $19 000 - $10.00 Over $19000 - $10.00 per $1 ,0 0 0 or 4. APPLICANT: Sovr fraction thereof r a 5. ADDRESS: d,q 6. EST. COST: 7. IS THIS A CONTRACT COST? (J YES NO 8. FEE ENCLOSED: e73D 7 9. TYPE OF BUILDING: _ a RESIDENTIAL COMMERCIAL 10. TYPE OF JOB: _ORIGINAL ALTERATION INSTALLATION ADDITION REPAIR BD 2A 11/88 APPLICATION FOR PLUMBING PERMIT (Cont. from Reverse Side) 11. LOCATION OF JOB: �c T-a GENERAL PLUMBING 12. KIND OF INSTALLATION: t 13. SIZE OF MAIN DRAIN T 14. NO. OF TOILETS _STYLE „J1T 15. N0. OF URINALS "' STYLE 16. NO. OF BATHTUBS_ 16A. NO. OF SHOWERS /- 17. NO. OF LAVATORIES 18. NO. OF SINKS_ 19. DISPOSAL l 19A. DISWASHER_� 20. NO. OF CONDUCTORS -- SIZE 21. NO. OF STACKS SIZE � ( 22. AREA OF ROOF 23. NO. OF CATCH BASINS 24. NO. OF FLOOR DRAINS 25. NO. OF OTHER FIXTURES - KIND 26. ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW? 27. SIZE OF WINDOW 28. IF NO WINDOW, WHAT KIND OF VENTILATION IS THERE? , ��/� e� 29. SIZE OF DUCTS-5 30. SEWER OR SEPTIC TANK? 31. SIZE OF WATER MAIN /ir 31A. SIZES OF WATER PIPING & RISERS 32. REMARKS AND FURTHER DETAILS Cv 4t 'e a � oZ /214 Tfi�,l WATER HEATER 33. TYPE r 34. MANUFACTURER TANKS SAFETY DEVICES TE1,1PERATURE 35. CAPACITY fo 39. RELIEF VALVE p� o ° 36. TEST PRESSURE /j'e'o LBS. 40. MANUFACTURER 4122*711f 37. WORKING PRESSURE 6i 0 LBS. 41. PRESSURE RELIEF VALVE 38. TYPE xx/. 42. MANUFACTURER �o' d c e LICENSE NO. DATE SIGNATURE O AP ICANT PHONE N0. p PERMIT # Application For v � DEPARTMENT DECISION 1� � Heating Permit APPLICATION IS HERESY: DWARTHFAT OF LICENSES AND INSPECT' NS ❑ APPROVED ❑ DISAPPROVED AS TOWN OF SOUTH WIN DSOR 0Q W I RATE CNN[/ so Cleo AFKKAIWU 0091 AA PROUD OR TT<•AO. REOM WITH HOMER ONE mew A •$ 1. LOCATION OF JOB 1WII LOT NO. neon :. OWNER �,I T 0 o. AODREss � 45ZZ144�7L/ - •.NONE S. APPLICANT a e. ADDRESS V.PNONE e. LICENSE NO. Q O. EXPIRATION DATE OF LICENSE Ir to. ESTIMATED COST • ji . V" 11. IS TWO A CONTRACT COM U YES NO 1:. FEE ENCLOSEDIV I • is. TYPE OF uNuNve AMNRENTML O COMMERCIAL A 14. TYPE of JOR: INDUSTRIAL VIAL r"', ALTERATION �+ WaTa11 ATIAM annITIIIN APPLICATION FOR SEA`1 uA 6 ej&rL*u-L � ' hmn s`°'ff" �oiue) 11. LOCATION OF JOB e! r -*/l � FLOOR APT.00. NO. SU99T IL TYK OF INSTALLATION: ❑ OIL BURNER ❑ ELECTRIC ❑ VENTILATION ❑ smNKLER L7 riAS BURNER ❑ STACK ❑ INCINERATOR 0-MISCELLANEOU5 Co�°'� , rounwT 511E LOCATION �FILL 13. OF TANK OF TANK OF t B.T.U. EQUIP. AT REGISTER FURNACE MAKE AND NO.C AT BONNET d� 4/0 FIRING RATE BOILER OR FURNACE MAKE AND NO.�10 O B.T.U. OR SQ. FT. NET__B.T.U. OR SQ. FT. GROSS___FIRING RATE FLOORS TO BE HEATED NEW OR OLD BUILDING INSULATED — YES OR NO TYPE OF WALL INSULATION ROOF OR CEILING INSULATION AVG. SYSTEM WATER TEMP. B.T.U./SQ. FT./HR. EMISSION INDOOR-OUTDOOR TEMPERATURE DIFFERENCE 'FAHRENHEIT MAKE OF RADIATION: BASEBOARD. COPPER CONVECTORS. OR C.I. RADIATION. OUTPUT PER SECTION OR LINEAL OF RADIATION. SQ. FT. OR B.T.U. DESCRIPTION F WORK is. TO BE DONE. Is. MAT LOSS SCHEDULE. (TO BE INCLUDED FOR ALL JOBS): woor slat w/Noows AREA — SOLMRE BEET s+.T.11. o.T.u. � DISTRISLM N INSTALLED ANo 000ws � TWgA. TOTAL a as love" wooN NO. t �� oVAY ITT w GSILIIA PL� CY./T. •� TO i F TV0t AND s1:t w•o• ON L Aotw L w ~ AND WALL Aft 11N/1LT.1 pR :i AO• FT• RRtt ARIA alzu TO,,ALS A. HEAT LOSS FROM BUILDING �-� f!I.T.UJHR. B. DOMESTIC HOT WATER DEMAND B.T.UJHR. C. PIPING. OTHER THAN NORMAL B.T.UJHR. ALLOWANCE FOR HEAT VALVE OF FUEL (A B C) FACTOR - 17. ELECTRICAL WORK BY: SUBCONTRACTORS AND is. THEIR TRADES ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE(=ERR NT) OF PERTY AND WILL BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE 'PLICATION TO 8.E COMPLETELY FILLED IN. Oat e i S=Oec-S7 HEATING / COOLING BTU LOSS ESTIMATE 101 NAME i 1M1 CONSTRUCTION CAMBRISE ESTATES DESISN CONDITIONS SOUTH WINDSOR CONNECTICUT. -------------------------- !4 Roost Phone Hlltingi 10 deg f.t/d ESTIMATORi - Bldgi LOT 11 Coolinp 20 dog f.t/d _ Room 1 Room 2 Room 3 Room 4 Room 5 Porlrlm 5 Roan 7 oom 8 Room 3 Room 10 "_-cm 11 Room 12 Room 1' AREA NAME FAM/ROOM ,'iTl Itv DIN/RM LIVlRM FOYER STUDY LAV ENTILAUND M/BR M/BATH B/F 3 B/R 2 BATH Outside Wall Lengy;l 38.0 21.0 Ty 36.0 12.0 .1.0 6.t� :'0.0 35.0 3.0 4. .` 16,0 8.0 Outside Wall Height 8.0 8.0 10.0 10.0 16.A 1 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 Sq/Ft S of W Glass 0.0 J.0 0.0 72.0 53.0 16.0 9.0 6.0 0.0 0. 0.0 16.0 9.0 S /Ft N or E Glass 42.0 39.0 30.0 0.0 0.0 0.0 0.0 0.0 58.0 6.0 16.0 0.0 0.0 N-1 of Doors 0.0 0.0 0.0 0.0 1.0 0.0 0.0 1.0 0.0 ".0 0,r} 0.0 0.0 Floor Width i5.0 21.0 15.0 14.0 14.0 11.0 6.0 6.0 0.0 0.0 0.0 0." 0.0 Floor Length 19.0 12.0 12.0 19.0 12.0 "1.0 11.0 14.0 1.1 0.0 0.0 0.0 0.0 Roof Width 0.0 0.0 18.0 16." 14.0 0.0 0.0 0.0 13.0 9.0 12.0 12.0 12." Roof Length 0.0 0.0 121.0 119.0 12.0 0.113 0.0 0.0 ?2.0 5.0 13.0 iG.0 8.0 -------------------- -------- -------- -------- -------- -------- -------- -------- -------- -------- -------- -------- -------- -------- Area Cubic Feet 2,280 21016 2,1b0 31040 2,68E 968 529 672 2,2$$ 360 I124$ 1,53b 768 Gross Wall sq/ft 304 160 270 360 192 88 48 160 280 72 96 128 64 Net Wall sq/ft 262 129 240 289 lie 72 39 133 222 bb 80 112 55 Wall Heating BTU 11467 722 11344 1,613 661 403 218 745 1,243 370 448 627 308 Wall Cooling BTU 524 258 480 576 236 144 78 266 444 132 160 224 110 S/W Glass sq/ft 0 0 0 72 53 16 9 6 0 0 0 lb 9 3/W Glass Heating BTU 0 0 0 31571 A. 794 446 29° 0 0 0 794 446 SIW Glass Cooling BTU 0 0 0 893 651 198 Ill) 74 0 0 " 198 ': 2 SIW Glass Solar BTU 0 0 0 5,760 4,240 11280 720 480 0 f) 1,280 720 N/E Glass sq/ft 42 39 30 0 0 0 0 58 6 16 0 N/E Glass Heating BT',! 2,083 1,934 11483 0 0 0 0 ri 1,8'7 298 794 0 0 NIE Glass Cooling BTU 521 484 372 0 0 v, 0 0 719 74 198 0 1 T t! C 12 r, +V r 132" 2 n N/E Glass Solar B,� 1,680 1,,,b0 1,�(;_: 0 0 u 0 0 1,3�.: �40 64�� v Doors sql f t 0 0 0 0 21 0 0 21 0 0 0 0 Door weating BTU 0 0 0 0 j,58 0 0 `38 0 0 0 0 Door Cooling BTU 0 0 0 0 168 0 0 168 0 0 0 0 0 Floor sglft 28w 252 180 266 168 121 GS 84 286 4` 156 192 96 Floor Heating BTU 4,560 4,032 2,880 4,256 2,688 11936 11056 1,344 0 0 0 0 Floor Cooling BTU 0 , 0 0 0 0 0 0 0 0 0 0 0 Roof sq/ft 28u 252 216 304 168 121 66 84 286 45 156 192 9E Roof Heating B1 0 0 518 730 403 0 0 0 68fi 108 374 I:61 230 Roof Cooling BTU 0 0 216 304 168 P, 0 0 286 45 156 192 96 Lights Cooling BTU 243 215 184 259 143 103 5fi 72 244 38 133 164 82 Appliance Cooling BTU 299 265 227 319 176 127 69 88 300 47 164 202 101 People Cooling BTU 107 95 68 100 63 46 25 32 109 17 59 72 36 ,.atert Cooling BTU 572 505 361 534 33/ 243 132 168 574 90 313 385 193 dentilation Heat BTU 11460 11204 11121 11831 11245 564 310 525 865 140 291 339 177 lentilation Cool BTU 710 609 559 1,574 11114 385 215 243 899 123 328 489 261 Duct Heat Loss BTU 574 474 44' 720 490 222 122 207 340 55 114 133 70 Duct Cool Loss BTU 219 239 220 yl9 438 152 84 95 354 48 129 192 103 --------------------- ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ 4rea Heating BTU 10,144 $,3bb 7,793 12,120 $,554 ",'i19 2,152 3,657 6,`12 970 2,�'21 2,354 1,2'3' area Cool:-g BTU 4,936 4,229 3,887 :01938 7,741 2,fi18 1,491 11687 61247 956 21280 . 31399 1,812 area Air Heating CFM 133 110 103 161 114 52 28 48 79 '? 27 31 1c area Air Coo11ing _FM 165 141 130 365 25$ 89 50 56 20$ i7 76 113 60 seating BTU's per CFM 'ro cooling BTU's per CFM 30 TTL Number of People x 4 TTL Bldg. Square feet 2,393 TTL Bldg. Cubic {eet ; 22,120 --------------------- ------ --------------------- ------ --------------------- ------ --------------------- ------ 5LDG Heat Loss BTU's 76,514 TTL Bldg. Heating CFM .> 11007 Bldg. Heat BTU/Sy-Ft 32 Bldg. Peat BTU/Cu-Ft > 3.46 3LDG�Cool Loss BTU's 54,943 TTL Bldg. Cooling CFM : 11831 Bldg. Cool B►U/Sq-Ft 23 Bldg. Cool P"1I :u-Ft : 2.48 • ENVIRO TECH. HVAC CO ITRACTINO Sectric#` APPLICATION FOR BUILDING PERMIT Plumbing# 125 C.AMBRIDGE DRIVE WAC # Date: '9 Spr,kQer# W. 26397 FNAL Estimated Cost $ Budd' x o--• COMPLETE RED BOXED AREAS Permit Fee � 104 Affidavit TYPE OR PRMIT ONLY Occupancy Fee $ -5 Appr.for CO. SIGN ON REVERSE SIDE Total Fee sa- TO BUILDING DEPARTMENT,TOWN OF SOUTH W14DSOR,CT G4dditional Cost) $ The undersigned hereby applies to do work according to the following specifications: Job Location 12.5 C to m b w%9l t 10 Lot No. 1 I Side of Street A.) Zone Applicant G r eR d ry G Zl v va-L Tel#_ 6 Y*-N Z2 Addr ss Is,-5 q m b r�d.��D�'' Zip Lic.# Owner Gy r Py c—ID v ypk- Address 1 2,S' GV4l M a r#,q-r flr Architect Address Sq. Ft.New Area: 1st Fl. 2nd Fl. 3rd Fl. Total New Area #Rooms #Lavatories #Bathrooms #Garages Purpose of this permit: S Aa$ SS, ,4 K--5 ity ater 0 Well ❑ Septic System 0 Sewer ❑ Ins. H.O. .P Cert._ Area Basement Garage Approved by Date 6 Use Group Construction Type- 5.7� R.vW 1/97 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all str t lines,side yard lines,and required distances from all other zones and is located in which this building and its use is allowed. Signed �• I hereby apply for a Certificate of Occupancy for the work described in this app' -on for the permit. Signed K �- DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS 1 � Inspection / Approval Date By Appl Code Description Due Whom Code Comment ---------------------------------------------------------------- --'----------- 99-26397-B 8,000 BO1 FOOTING 08/19/99 DCJ A B10 FINAL 04/11/00 JFF A B10 FINAL 04/12/00 JRC A CLOSED OUT. � i1r 1.1 � t' tJI �ONN M. �u442OcJ L•� �41�1Yl�C�4,;Y �. J,UgIrPN11.Jc�', y p� � J . M AX-I A 61 A, so rho f3�t`.`fC� s 15oc�c� � . o ' \ ti 24� 24L 32 Ul I C) doop .10 1 t i g` s i 1 �S� i � vccw � 1-IeuSE r = '�•244.1. _�• ROPERTY MAY BE WWECT ��`r4' � 14 --- 2at 1 :OFW AS MAY APPEAR. C tldtrilatl6h Croflpahy E i i i ngtotl Road �� ti F° ° p � h Wind*or t CT 06074 Av C,AM 6 CA s to 144. SM w 64 z4c, �\ a td dro lto he* Woo Oripar d 42 itt +n the bath of b lliltod ln- gatlbh of -itlbourtobo iaoadltl no* urVOtor•of 1 1 hit be letp nelbko t r -rror• or '461441e1t• �Ottrlirint to �rt4orr 4mwitliwr, t"eblp"thtod lMta AY. ro p /i,Adi6-`A yriddr- - i d f, TO THE BUILDING DEPT. TOWN OF SOUTH WINDSOR rpis rertified that this plan and specifications are true oole6 of the proposed building or alterations to be rested at as Street ,grther with amendr nt�qat in appOication an, il,.d with plan and I agree tmply with afl zoning •uo:iing and state laws and such orders as shall b• ,,i, d by the Building Department during pendency this application and final issuance of buildmj� ucrmrt. � P Signed his plan is appr d u iect to the condition that -,rd,rs and crdinances regulating building shall be -cr.plied with Conditionally Approved These filed with Building Inspector )) zzpleerrk I�►CATIo N OF ZONING COMPLIANCE f use(s) andjor ljtructure(r .�•roposed buildingk lan appear�S) to be, o rt this P Vd, � with currPn� .� • �1 ,jf`.,.r,iance E,�c:�pt'. Zulattons. Va,lances and J� :�Ay appl- _,ate r - rig rceiMnt Of Y i�er FINAL INSPECTIONS, APPLICATION FOR BUILDING PERMIT Building Plumbing Plum Date: December 13, 1990 HVAC Sprinkler 125 CAMBRIDGE DRIVE Electric Estimated Cost $ 25.00 Zoning Permit Fee$ o Affidavit NO. 18 9 5 6 Occupancy Fee $ Eng. Dept. COMPLETE RED BOXED AREAS. Fire Dept. TYPE OR PRINT ONLY Total Fee $ ,�� H alth D pt. SIGN ON REVERSE SIDE. Approved for CO: (Additional Cost) $ TO BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT The undersigned, hereby applies to do work according to the following specifications: Job Location rK r& r• Lot No. 11 Side of Street N Zone Applicant Gregory C. Duval Tel. # 648-1429 Address 125 Cambridge Drive, So. Windsor, CT Zip 06074 Lic.# Owner ' Gregory LTREETY buval c�_ Address 12�T`�ambridge Dr. ,So.Windsor,CT 06074 Architect Address Size New Area: Ft. Front Overall Ft. Deep Overall Total Area #Garages Lavatories No. of Families No. of Stories Construction Bathrooms Rooms 1st 2nd 3rd Size of Lot Dist. from Street Line Dist. from Side Street Line Purpose of this Permit To approve installation of air tight wood burning stove in existing masonary fire place utilizing existing masonary chimney. Country Comfort model CC 300 Manufactured by Orrville Prod. Inc. City Water ❑ Well ❑ Septic ❑ Sewer ❑ Approved by 01 A i" Date �� BD1A 11/88 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located th proper distanc from all street lin s,sid yard lines and required distanc s from all oth r zon s and is located in a zone in which this building and its use is allowed. Signed MA Qj, C J A.A 210 I hereby apply for a Certificate of Occupancy for the work described in this application for permit. Signed —DO Nor WRITE BELOW THIS LINE— INSPECTION RECORD Footing Framing Foundation Fireplace/Chimney Insulation Plumbing Permit# Inspections: HVAC Permit# Inspections: Electrical Permit# Inspections: Sprinkler Permit# Inspections: 1 Y� This Certifies that the Wood/Coal Stove install Pursuant to Permit No. �__ granted has been duly ins installation p for which the above named Permit was petted and is hereby approved. Owner Edd Hu e Street 6 Wed ewood Drive 19 91 / Building Inspector FINAL INSPECTIONS: ATI FOR BUILDING E Building APPLICATION O U G PERMIT Plumbing HVAC Date: Sprinkler 125 CAMBRIDGE DRIVE Electric Estimated Cost $ o(7 Zoning Permit Fee $ Affidavit ± NO. 18005 Occupancy Fee $ Eng. Dept. COMPLETE RED BOXED AREAS. q,p Fire Dept. Total Fee $ Health Dept. TYPE OR PRINT ONLY Approved for CO: SIGN ON REVERSE SIDE. (Additional Cost) $ TO BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT The undersigned, hereby applies to do work according to the following specifications: Job Location Lot No. Side of Street Zone Applicant'jcdgmt 1p ?=Zs- Tel. # Address,,TVV t Zip067.3r' Lic.# S r STREET CITY STATE Owner X'J i•, ef'&('i Address -w _.ems AAm-j -e_ Architect Address Size New Area: Ft. Front Overall 12 Ft.Deep Overall Total Area #Garages Lavatories No. of Families No. of Stories Construction Bathrooms Rooms 1st 2nd 3rd Size of Lot Dist. from Street Line Dist. from Side Street Line4-2 R�Q6 It Purpose of this Permit Z— S T)0 f' Q/E✓ ! ,- �J e r loll .sue �e.v� City Water Ga' Well Septic Sewer Q/ Approved by Date — - BD1A 11/88 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines and required distances from all other zones and is located in a zone in which this building and its use is allowed. Signed-ad"�,.' 6 I hereby apply for a Certificate of Occupancy for the work described in this application for permit. Signed —DO NOT WRITE BELOW THIS LINE— INSPECTION RECORD Footing Framing Foundation Fireplace/Chimney Insulation Plumbing Permit# Inspections: HVAC Permit# Inspections: Electrical Permit# Inspections: Sprinkler Permit# Inspections: � v t , , e 7 4 1 e r 1 �? ilk _ 1 l 1'fir Pro /O Pa�j L 4 .1 r 4 � �o vs� '-7• __ 3 G 36 Gs4r � '✓�� o B4 _,,ems/ •s eel � n � tr i?r- i ��s� �Sv�.s A."Ks 114V��y Farrcc` /.� S Cii�i+^9' • !.¢G� t. C.Gi'4.� LtJI l�sj�rl �fsG. ��"4*0A0^4d •,� C�fL�.S� j e- r ', k ki .r9ssaic.v��o•a dw/ 4•04V d J"Z,r r a/c 0-, Ac /,m- i .� �o ' �Ssjt,� /, /1819 s. F an 'jE P 1 1989 South Windsor BUILDING DEPARTMENT j1 I id %k_' TO THE n-,are true This certl(i.,d t`�.t L.ts Alen ,nc1 Sp c�i�� u r-opies of the proposed buddi^Q c," c n+ on; to be erected at +� } ` tl, r endrt, t' st.t: s.+ together w 1n i n A ✓` died with plcn .rid i -gr,:o to comnly q' 3 - Off�Cer, ,�+►" �uildlaR and state laws and such Ord r5 ement -,sued by the Building Departmant dnrirl 1 �ontng Enforc� ( this application and final issuance of hermit. ;,fined - itsI3 is proved subject to tht l o�icrs r,o tdan:,tttws � gu'Iatm4L bvaiGln Tbes.� nidrtlon.,',•� „pprcved -- CA . u i IBC,r.! n c p ctrrr t - ca C 1540 SULLIVAN AVENUE SOUTH WINDSOR, CONN. 06074 oR•Co AREA CODE 203/644-2511 veil iAtIJIUB E t. T(W.'To 'Xil applicants for inground swimming pools FROM: John R. Collins, Chief Building Official DATE: May 16, 1988 SUBJECT: FENCING REQUIREMENTS All pools are to be -totally enclosed by at least some type of temporary fencing prior to filling the pool. Failure to do so will result in an immediate order to empty the pool by the South Windsor Building Department. I have read this notice and will comply. Ll Applicant ate D ►' 1 1989 South Windsor BUILDING DEPARTMENT '0 THE 4YfNCSUtt i his certifif d that tr.,3 pl•n ,nd sp rific-tlins are true copr.s of the proposed or 'ilterations tek bq erected at � _ [tic- Iuit`_w .tT�li 1 ti� th elk '.lark pow N co ap S-OU& C � o ti 1540 SULLIVAN AVENUE ° SOUTH WINDSOR. CONN. 06074 R.COt, AREA CODE 203/644-2511 July 31, 1990 Vincent Striano 125 Cambridge Drive South Windsor, Connecticut 06074 RE: Inground Pool Inspection 125 Cambridge Drive To Whom It May Concern: Please be advised that your swimming pool installation has not been approved by the South Windsor Building Department. The following items are needed for this approval; Electrical Permit X Electrical Inspection X Final Inspection X Other I urge you to resolve this situation at your earliest convenience, as the use of your pool without Building Department approval is a violation of Connecticut General Statutes, and could lead to an unnecessary liability. Sincerely; James Emery Assistant Building Official f r 1540 Sullivan Avenue �~ South Windsor CT 06074 V v lift IIIIII lilt lilt 11111I11It1111111I1lIfIIIIIti1111) 4,rMemo from TOWN OF SOUTH WINDSOR TOWN HALL SOUTH WINDSOR,CONN.06074 F To George Spring DATE 8/28/90 Director of Finance Town of South Windsor L SUBJECT: REFUND FOR PERMIT FEE--BUILDING PERMIT FOLD- Please refund the amount of $45 to Sabrina Pools, RT 44, Coventry, CT. 06238. This amount is h the original permit fee - of $90. The pool for which this permit was issued (B. P. 18005) was never installed on Lot 11, 125 Cambridge Drive. Thank you. �C �p 't By C_ H_ Murray, Building -Dept, j I TOWN OF SOUTH WINDSOR, CONN. ' No 18005 D BUILDING PERMIT Y Est. Cost: 9,000. 00 Fee: 90.00 �;. AUG 27 IM CO Fee: ' Date: 9/5/8 9 South Windsor �Tx BUILDING DEPARTMENT •_ APPLUNT LOCATION Name: Sabrina Pools Address: 125 Cambridge Drive Address: Rt 44 Owner: Vincent Striano Coventry- CT 06.238 Work Description: Ynground pool Lot # 11 Size: Wide, Long, _Stories, Dwelling Units_ Building,street,and each side lot line to be in accordance with certified engineer's plot plan on file a NUETHE RECIPIENT OF THIS PERMIT ACCEPTS THIS PERMIT ON THE CONDITION THAT HE,THE OWNER OR REPRESENTING THE OWNER,AGREES TO COMPLY WITH ALL BUILDING AND ZONING ORDINANCES OF THE TOWN OF SOUTH WINDSOR AND THE STATE STATUTES OF CONNECTICUT REGARDING THE USE,OCCUPANCY,AND TYPE OF BUILDING TO BE CONSTRUCTED. Building Department Town of South Windsor,Conn. Building Official *A su�q t r J�. FF V f .J4 ~,J x� F, a �, d 'f ,[¢i n f r w �� y S i y v .., s + �ZO pit ��Mfi"= w N a pi l7 �to ,`� r OP//F v <PA 0 1540 SULLIVAN AVENUE SOUTH WINDSOR. CONN. 06074 R•co AREA CODE 203/644-2511 July 31, 1990 Vincent Shia S I R Ia 110 125 Cambridge Drive South Windsor, Connecticut 06074 RE: Inground Pool Inspection 125 Cambridge Drive To Whom It May Concern: Please be advised that your swimming pool installation has not been approved by the South Windsor Building Department. The following items are needed for this approval; Electrical Permit X Electrical Inspection X Final Inspection X Other I urge you to resolve this situation at your earliest convenience, as the use of your pool without Building Department approval is a violation of Connecticut General Statutes, and could lead to an unnecessary liability. Sincerely; 4 0" James Emery Assistant 'Building Official DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT PEMET# 149LI) Application is hereby: TOWN of SOUTH WINDSOR BUILDING DEPARTMENT Bldg Permit# APPROVED 1540 SULLIVAN AVENUE 4-n 644-2511 ext.230 Date ding Inspector Application must be printed or typed Location of job 12-5 GPMbndge-, 01-, ll Street No. Street Lot No. FEE SCHEDULE � Floor Apt.No. $0 - $1,000 - $12.00 Over $1,000 $12.00 per$1,000 OWNER C. Dcivo,4-- or any fraction thereof ADDRESS 12,5 C,11 w3 k rJ Or. V C."T p6c"?y OWNERS PHONE# I Z,� APPLICANT Gve-2c-,ry C, f)"voL— ADDRESS C;P+m Los"rid ESTIMATED COST$ 0 IS THIS A CONTRACT COST? YES NO , FEE ENCLOSED $ 12 o o OR-Co TYPE OF JOB: Original Installation Alteration/Addition Repair Revised 11/95 APPLICATION FOR ELECTRICAL PERMIT(Continued from reverse side) TYPE OF BUILDING / IS THIS APPLICATION ASSOCIATED WITH V RESIDENTIAL BUILDING PERMIT APPLICATION YES / NO BUSINESS ASSEMBLY CURRENT USE AND OCCUPANCY I MERCANTILE EDUCATIONAL FUTURE USE AND OCCUPANCY Fi9rn 4em E_ INSTITUTIONAL FACTORY STORAGE ENGINEER'S NAME PHONE GARAGE MIXED USE ADDRESS CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION/WIRING METHOD S nd airw A To co df- SIZE OF MAIN FEEDERS AND RATING OF WIRE USED aU pfl-VIP )Z-2 Rd m NUMBER OF METERS NUMBER OF DISCONNECTS AND RATINGS I 2 04c-� NUMBER OF PANELS_L REMOTE DISCONNECT REQUIRED?YES NUMBER OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES -3 NUMBER OF OUTLETS Q NUMBER-OF LIGHT FIXTURES -3 NUMBER OF HEAT CIRCUITS (-')_ NUMBER OF A/C CIRCUITS SEPERATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK Tn-5,-hq V 3, CeAeim T;gna- w4 Li-5-4y THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONN.BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. ov e Cr w n V� NAME STATE LICENSE NO. E SIGN.A:tUtRE OF APPLICANT PHONE NO. DATE _l ` �oNt�l M, S",kQON L.� A. JoS�PHI�►G- T, ��t' � J . P�''�l�:�t-:�c�� M A G I A 61 A Z%6 \ 8`1 o 5, c 4„ E I \ 0o N z4 24eo � r � W A. loe I Vf-0- a.a• eta,• «TF- .� f �uSE TM PROPERTY MAY BE SUBJECT �,�3• � � .��_. _ TO YA U1�l.ITY EASEM �- � K Z, OF RECORD AS MAY APPEAR. 24Zt — Li W V— illi Cvnstructfon Cbsipanyr -- 654 9-41-ington Road a ''South 41 ndaor, CT 06074 � i � P � w - n oaw•� C,AM 8 9 Q F— zoo �\ 11*0 WOO V**poz*d 24Z t� ��t..`4M 'tart �el �► ���!t�►rt i»- ti�t#srq*„0~1 t4*TW. -_owr4"W•of 1,het be,0. i b%0 tear Mali► pre e�. traldasst•iw#irs to it�. �r�tue��g.:ne ii •s a� -•�i� RI�► �t trbois�,tl�es` Aasuea-�� AA -OW hin �tN cr V�au►-�'►o•.►�► vt r-tN 'R�'�EG? 'ts �s►�.o�wt,. lrc�4z�oN LOT L ME$ FROM MAP 04 FILE 717LED VLOT PLAOA. CWF3 MPE ES'TA v6 PREP►RED FOR J�Aa GXA43T'RUCT%0ti 00. C. 0. PLOT PLAN ISC)tlT" \*41M0%C)R, COMIC" %Y REMO E. V4YY PPA 4 A►$SCC.� XEto SCALE % = 4 o LOT I DWE 7-2-Z-84+ MAP %% o- SHF-S ' .4 of RSV TMRV CAMBRIDGE ESTATES PREPARED FOR MILLER REALTY SOUTH WINDSOR, CONN. I tweby doctors thot this map Is substontkOly correct. This map on4 *Wvey were prep4red In occardonae with the stondords f a Clop A-4 survey oa defined in th "R Standards for Sty vnd Woe In the Stott of Co+nocticuV os prepor d and odaptid by the Connecticut Association of Land Surveyors, Inc., REINO E. HYYPPA ASSOCIATES or+=SsptewOw 13. 1984. C�vt� E�NSsrE •�A o sunYE'rofts AEG 1 South Windsor L 9 BUILDING DEPARTMENT Au THE Thiscome C®rtlfled that th. r `o ecte Of the P opos s Plan and spec. +1c (' c ,p d at building or r filed twftr with amendments — 8url h plan and 1 tit`Cf in drag and sta agree 10 c.)n; issued_h ,. to laws w plY' 4. Y ! e 13dt And cry is .n1s appliCatlo ltling Department dun., Permit. n and final issuance of Signed This plan is apl oved s orders and 1ect t° Com °rdrnances the t,,, — p�I(I f wrlh. re8'Wartrn r g b�4jtlin,r s�:�t 09ndrttonally Approved Mtilding lnspe, a� nr hate `C.IIt r. 146. pA T y