HomeMy WebLinkAbout137 Cornerstone Drive (3) eectric P 1-7o S0 APPLICATION FOR BUILDING PERMIT
Plumbing# _ O G7 137 Cornerstone Drive
WAC # �(o Date: 6
N6. 27274
Sprinkler#
FINAL APPRO LS Estimated Cost �� '�0=
Building -a3-01 COMPLETE RED BOXED AREAS P rmit Fee $ 30�2
E4�ing TYPE OR PRINT ONLY ccupancy Fee
Affidavit SIGN ON REVERSE SIDE
Appr.for CO. Total Feesz-
TO BIAl M DEPARTMENT,TOWN OF SOUTH WNDSOR,CT (Additional Cost) $
The undersigned hereby applies to do work according to the following specifications:
Job Location r Lot No. Side of Street Zone
Applicant Tel
Address Zip Lic.#
Own r Address
Architect Address . 0
Sq.Ft.New Area: 1st FI. 2nd FI. 3rd Fl. Total New Area _
#Rooms #Lavatories #Bathrooms #Garages
Purpos of this permit: IAR�)
City Water Well ❑ Septic System ❑ Sewer ,
Ins. H.O. .P. Cert. Area 59(ol Basement 2O 9 Garage Z
Approved by Dat 31 ed Use Group Construction Type r'
R*rsW 1197
I hereby agree to conform to all the requirements of Laws of the State of Connecticut and the Ordinances of the Town of
South Windsor and to notify the Building Inspector y alteration in the plans or specifications of the Building for which this
permit is asked,and agree that this building is to ed the proper distance from all street lines,side yard lines,and required
distances from all other zones and is located in is i building and its use is allowed.
Signed
I hereby apply for a Certificate of O r the work described in this application for the permit.
Signed
DO NOT W ITE LOW THIS LINE
INSPECTION COMMENTS
Location of Job: AFFIDAVIT Additional Fee$ - 0 -
State of Connecticut
ss.South Windsor
County of Hartford
Owner
1 of Agent for the building erected
Contractor
under Permit No. 27274 issued by the Building Department of the Town of South Windsor being
duly sworn,make oath and say that the actual cost of the completed work authorized under said permit did not
exceed the submitted estimated cost
Signed
Subscribed and sworn to before me this day of A.D.20
Estimated Cost S 255,850
Difference: S (2 2, 9 0 5)
Notary Public
Inspection / Approval Date By Appl
► Code Description Due Whom Code Comment
-------------------------------------------------------------------------------
**-27274-B 233,850
B01 FOOTING 09/19/00 CJD A W/CONTRACTOR
B02 FOUNDATION 09/27/00 JFF A WITH CONTRACTOR FOUNDATION WATERPROOFING AN
FOOTING DRAINS
P02 UNDERGROUND 11/15/00 JFF A LEFT APPROVAL STICKER
E01 SERVICE 11/21/00 JFF A
B05 FIREPLACE/CHIMNEY 11/30/00 CJD A THROAT OK- W/OWNER
B03 FRAMING (ROUGH) 12/08/00 CJD D RESCHEDULE INSP.
B03 FRAMING (ROUGH) 12/11/00 CJD D HIP RIDGE BEAM CONNECTIONS LACK INTEGRITY
BOB J. TO GET ARCHET. OR ENGNR. OPINION
B03 FRAMING (ROUGH) 12/29/00 CJD A W/OWNER
PO4 GAS TEST 01/16/01 JFF A LEFT APPROVAL STICKER
E03 ROUGH 01/17/01 CJD A W/ELECT.
P03 ROUGH 01/17/01 CJD A W/BOB JACKSTON
B04 INSULATION 01/24/01 CJD A W/CONTRCTR
E09 OTHER 02/15/01 CJD A VISIT SITE TO ANSWR. ?IS ON SERV. PANEL.
SUPPLY DUCT IN DEDICTD. SPACE. NEED SWTC.C.ST
B10 FINAL 04/23/01 CJD A W/BOB JACKSON
B10 FINAL 04/23/01 CJD A CLOSED OUT.
**-10967-H 7,000
**-10674-P 10,000
**-17050-E 5,000
Total Est Value 255,850
Dwelling 3,969 191,623.32
Basement 2,049 29,095.80
Garage 824 11,700.80
Smoke Det 7 525.00
BOCA Value 232,944.92
Difference (22,905.08)
• Inspection / Approval Date By Appl
t Code Description Due Whom Code Comment
-------------------------------------------------------------------------------
**-27274-B 233,850
B01 FOOTING 09/19/00 CJD A W/CONTRACTOR
B02 FOUNDATION 09/27/00 JFF A WITH CONTRACTOR FOUNDATION WATERPROOFING AN
FOOTING DRAINS
P02 UNDERGROUND 11/15/00 JFF A LEFT APPROVAL STICKER
E01 SERVICE 11/21/00 JFF A
B05 FIREPLACE/CHIMNEY 11/30/00 CJD A THROAT OK- W/OWNER
B03 FRAMING (ROUGH) 12/08/00 CJD D RESCHEDULE INSP.
B03 FRAMING (ROUGH) 12/11/00 CJD D HIP RIDGE BEAM CONNECTIONS LACK INTEGRITY
BOB J. TO GET ARCHET. OR ENGNR. OPINION
B03 FRAMING (ROUGH) 12/29/00 CJD A W/OWNER
PO4 GAS TEST 01/16/01 JFF A LEFT APPROVAL STICKER
E03 ROUGH 01/17/01 CJD A W/ELECT.
P03 ROUGH 01/17/01 CJD A W/BOB JACKSTON
B04 INSULATION 01/24/01 CJD A W/CONTRCTR
E09 OTHER 02/15/01 CJD A VISIT SITE TO ANSWR. ?IS ON SERV. PANEL.
SUPPLY DUCT IN DEDICTD. SPACE. NEED SWTC.C.ST
B10 FINAL 04/23/01 CJD A W/BOB JACKSON
B10 FINAL 04/23/01 CJD A CLOSED OUT.
Inspection / Approval Date By Appl
Code Description Due Whom Code Comment
-------------------------------------------------------------------------------
**-10967-H 7,000
**-10674-P 10,000
**-17050-E 5,000
SITE COMPLIANCE CHECKLIST
TOWN of SOUTH WINDSOR, CONNECTICUT
137 CORNERSTONE DR LOT_##19 Reviewed By ,d L� Bering)
ROBERT N. JACKSTON Date Reviewed 6 a jApip5rove Denied
330 ABBE ROAD EXT,SOUTH WINDSOR,CT Reviewed By o\ ing)
BP_#_27274_ Ph_##_296-9560- Date Reviewed 1J" enied
Date Submitted 00/00/00 ***** FOR f 0
As required in the Zoning and/or Subdivison Regulations, no Certificate of
Occupancy shall be issued until grading plans have been complied with and
approved by the Town Engineer. The minimum requirements shall include:
Approved Denied N/A
1/ 1. Approved building permit plan
2. Finish grading per approved
building permit plan
3. Site work; i.e. trees, shrubs,
dumpsters, required parking
/ 4. Utility location;
V a. sanitary sewer/septic system
V b. foundation drain S.AdwN _CN8,cK
C. electrical & telephone
td. water
e. other CIA s
Y 5. Sewer connection charge paid
6. Appropriate certification
t
7. Bonding
8. Planning & Zoning/
Inland Wetlands Considerations
A. Lighting
B. Signage
Freestanding Wall
/ C. Fee in lieu of Open Space
Sewer Permit No.
Pavement Excavation No.
COMMENTS:
SITE COMPLIANCE CHECKLIST
TOWN of SOUTH WINDSOR, CONNECTICUTT
137 CORNERSTONE DR LOT_##19 Reviewed By FW#. (Engineerin )
ROBERT N. JACKSTON Date Reviewed 8 %3 v Approve Denie
330 ABBE ROAD EXT,SOUTH WINDSOR,CT Reviewed By v
BP_#_27274_ Ph_#_296-9560- Date Reviewed W rov e
Date Submitted 08/23/00 ***** FOR 2tJILjING
In accordance with the Zoning and/or Subdivision Regulations, prior to the
building of any structure on a lot, a Topographic Plot Plan shall be submitted
for approval. The minimum requirements shall include: d' 31 fi
Approved Denied N/A
1. Name, address & phone number of owner/applicant
2. Name, address & phone number of plan preparer
3. Zoning Information - i.e. zone, open space,
floodway, street address.
4. Plot Plan at 1" = 40' scale
a. Subdivision reference, abutting properties, etc
b. Easements of record
C. Lot description, bearings, building lines,
distances, area, etc.
d. Contours, existing & proposed, 1 or 2 ft.
interval where appropriate
e. Building location with dimensions.
Elevations of proposed finish floor, garage
floor & centerline of road at driveway
f. Elevations of gravity drainage systems, sanitary
& foundation drain at the house and the street
g. Tentative utility location (gas, water,
electric, septic system, etc.)
h. Title block with name and address of preparer,
date, appropriate certification, live seal and live
signature consistent with the Board of Registration
requirements. (P.E. & L.S.)
5. Sedimentation and erosion control
6. Special Planning & Zoning, Inland/Wetlands
considerations (Plans on file w/Town Clerk)
COMMENTS:
S�kD (I rMo Co�JS L oa v mil/
Awi� WA�� As �61ow•✓ oN VtAJUCi�o ALA ow Af fPve> 5cr :-)% )j EOM Q(�V s IV
�O
� . SAAl
UN
ENG,CEP N
DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT
MIT#
R
Application is hereby: TOWN OF SOUTH WINDSOR 170,5-0
PER
BUILDING DEPARTMENT
APPROVED' 1540 SULLIVAN AVENUE Bldg.Permit#
,Z.fj QIN U
644-2511 ext. 230
Date BuildiQ Inspector 7
Application must be printed or typed
FEE SCHEDULE Location
of Job:
/ X,
$0-$1,000=$13.00 Street No. Street Lot No.
Over$1,000=
$13.00 per$1,000
or any fraction thereof Tenant Designation Apt.No.
APPLICANT
APPLICANT ADDRESS �w
APPLICANT PHONE#
W N .S OWNER l//o1'r"rTr/��.f1�a P
O �q� OWNER ADDRESS .?tea
�`'" Sou �,✓,� ��
CO !� E., OWNER PHONE G
ESTIMATED COST$ -5 10
V
r�
IS THIS A CONTRACT COST? JO Yes O No
FEE ENCLOSED$
TYPE OF JOB:
l)S�R.Cpl`�
91 Original Installation
13 Alteration/Addition/Repair Revised 8/99
APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side)
TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A
BUILDING PERMIT APPLICATION?arYES ❑ NO
❑RESIDENTIAL
❑ BUSINESS CURRENT USE AND OCCUPANCY
❑ASSEMBLY
❑MERCANTILE FUTURE USE AND OCCUPANCY
❑ EDUCATIONAL
❑INSTITUTIONAL ENGINEER'S NAME PHONE
❑FACTORY
❑ STORAGE ADDRESS
❑ GARAGE
❑MIXED USE CITY STATE ZIP
(Other please specify)
TYPE OF INSTALLATION/WIRING METHOD yArJr 10";qe-,y
SIZE OF MAIN FEEDERS AND RATING OF WIRE USED
NUMBER OF METERS / NUMBER OF DISCONNECTS A RATINGS
NUMBER OF PANELS REMOTE DISCONNECT REQUIRED? ❑YES ❑NO
NUMBER OF LIGHT CIRCUITS 2 NUMBER OF POWER CIRCUITS
NUMBER OF SWITCHES d 6 NUMBER OF OUTLETS 7-1
NUMBER OF LIGHT FIXTURES Ya NUMBER OF HEAT CIRCUITS /to
NUMBER OF A/C CIRCUITS
SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED.
DESCRIPTION OF WORK
A..
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
CONTRACTORS LICENSE NO. TYPE STATE
SIGNATURE OF APPLICANT DATE 0 - 6
John Collins-CRS Approvalon irmation: equest o. age
From: <clpsvc@nu.com>
To: <COLLIN@SOUTHWINDSOR.ORG>
Date: 11/30/00 12:41 PM
Subject: CRS Approval Confirmation: Request No. 162485
Your approval of the following CRS Request has been successfully processed.
CRS Work Request#: 162485
House No: 137 -or.
Lot No:
Street Name:
DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT
PERMIT#
Application is hereby: TOWN OF SOUTH WINDSOR /� y
BUILDING DEPARTMENT
APPRO D 1540 SULLIVAN AVENUE
Bldg.Permit#
t (C w 114"!, 644-2511 ext. 230 9 ?a?y
Date Building Inspector
Application must be printed or typed
Location of Job:
FEE SCHEDULE
13 ? �'a,ci✓UC S T oti
$0-$1)000=$13.00 Street No. Street Lot No.
Over$1,000=
$13.00 per$1,000
or any fraction thereof Tenant Designation Apt.No.
APPLICANT gy L At K 10 /3&Z
APPLICANT ADDRESS 90 wa t co r T s
TWAYv,LL b� e-f ??(o
APPLICANT PHONE# Of " 7 5-3 oZ
001 OWN 3 OWNER Ig O/3 '—A-e-KST oA/
q� OWNER ADDRESS
OWNER PHONE
ESTIMATED COST$ zD, od O
IS THIS A CONTRACT COST? 0 Yes RtNo
FEE ENCLOSED$ l,3 G•
O TYPE OF JOB:
OR�C �/'
!(New Installation
0 Alteration/Addition/Repair Revised 8/99
APPLICATION FOR PLUMBING PERMIT (Continued from reverse side)
TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A
BUILDING PERMIT APPLICATION? ❑ YES ❑NO
RESIDENTIAL
❑BUSINESS CURRENT USE AND OCCUPANCY
❑ASSEMBLY
❑MERCANTILE FUTURE USE AND OCCUPANCY
❑EDUCATIONAL
❑INSTITUTIONAL ENGINEER'S NAME PHONE
❑FACTORY
❑ STORAGE ADDRESS
❑GARAGE
❑MIXED USE CITY STATE ZIP
(Other please specify)
TYPE OF INSTALLATION SIZE OF MAIN DRAIN
NO.OF TOILETS STYLE NO.URINALS STYLE
NO.OF BATHTUBS NO.OF SHOWERS [ NO.OF LAVATORIES (v
NO.OF CONDUCTORS SIZE NO.OF STACKS .2. SIZE 3
AREA OF ROOF NO.OF CATCH BASINS NO.OF FLOOR DRAINS
NO.OF OTHER FIXTURES KIND
ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW ❑YES ❑NO
SIZE OF WINDOW IF NONE C.F.M.OF VENTILATOR
SIZE OF DUCTS SEWER OR SEPTIC TANK 6 t wrye
SIZE OF WATER MAIN SIZE OF WATER PIPING&RISER 3 L
WATER HEATER: TYPE MANUFACTURER
DESCRIPTION OF WORK
`4L 6 O t-Ttt F K Lt�-
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
CONTRACTORS LICENSE NO. TYPE STATE
SIGNATURE OF APPLICANT DATE !l- /y-ea
DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT
PERMIT#
Application is hereby: TOWN OF SOUTH WINDSOR PE 6
BUILDING DEPARTMENT /0
APPROVED 1540 SULLIVAN AVENUE Bldg.Permit#
644-2511 ext. 230
Date Buil g Inspector
Application must be printed or typed
FEE SCHEDULE A0111- Location of Job:
3 9� Co
$0-$1,000=$13.00 Street No. Street Lot No.
Over$1,000=
$13.00 per$1,000
or any fraction thereof Tenant Designation Apt.No.
APPLICANT
APPLICANT ADDRESS &
o �
APPLICANT PHONE#
OWNER O P7
��� N S Fq
OWNER ADDRESS
' E
A tot OWNER PHONE
C ESTIMATED COST$ o 0 !
IS THIS A CONTRACT COST? JYes 0 No
FEE ENCLOSED$_
TYPE OF JOB:
KM Original Installation
13 Alteration/Addition/Repair Revised 8/99
APPLICATION FOR HVAC PERMIT (Continued from reverse side
TYPE OF SYSTEM: TYPE OF BUILDING:
CHEATING .ff RESIDENTIAL
IAA/C ❑ COMMERCIAL
❑VENTILATION ❑ INDUSTRIAL
HEATING
❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS.
❑ HYDRONIC Ad WARM AIR ❑ UNIT RADIANT HEATER
EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION
DESIGN TEMP. OUTSIDE 4 OF INSIDE 7d OF DIFFERENCE o OF
TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY
APPLICATION)
DESCRIBE ALL HEA ING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
�r_A j rh ` `
ef_�Tcli_
G� o
GROSS HEATING CAPACITY(INPUT-BTUH) NET RATING(OUTPUT-BTUH) a �'
TYPE OF FUEL
❑ OIL-GPM .a GAS-INPUT ❑ ELECTRIC-KW
OIL TANK SIZE&LOCATION
❑ INSIDE ❑ OUTSIDE CAPACITY LPG TANK CAPACITY
AIR CONDITIONING q/16
DESIGN TEMP. OUTSIDE OF INSIDE b OF DIFFERENCE CZ;P OF
TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION)
DES I IL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
TONNAGE COOLING CAPACITY(BTUH) �D Ct)
VENTILATION
DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT)
TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM)
(PLANS MUST ACCOMPANY APPLICATION)
FURTHER DESCRIPTION OF WORK
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
.3 S>,57-p g3 C17-
CONTRACTORS LICENSE NO. E STATE
SIGNATURE OF
APPLICANT DATE �/c �/®
a
r t
CALL/PLUS HEAT LOSS/GAIN CALCULATION BY E & K HEATING & AIR CONDITIONING LLC
FOR INFORMATION OR TO PLACE AN ORDER CALL (860) 496-9327 (860) 584-8677
Software Copyright (C) 1987-1996 by Ed Horgan (H.V.A.C. ) (610) 384-1923
DESIGN: WINTER, 70 DEGREES DIFFERENCE SUMMER, 20 DEGREES DIFFERENCE
JOB: JACKSTON - RESIDENTIAL CALCULATION HTM HTM AREA BTU/HR BTU/HR
DATE: 12-12-2000 HEAT COOL OR # LOSS GAIN
BASEMENT - UNHEATED NO LOSS OR GAIN
BATH RM # 1, WEST & NORTH HEAT COOL VALUE LOSS GAIN
1 WINDOW DOUBLE GLASS LOW E 20 X 64 IN, NO 31 . 0 64 . 0 9 276 569
CEILING UNDER CONDITIONING, NO LOSS/GAIN 0 . 0 0 . 0 0 0 0
HARDWOOD FLOOR, Rll INS OVER ENCLOSED SPAC 2 . 8 0 . 0 90 252 0
EXHAUST FAN, 45 CFM WITH . 05 USAGE FACTOR 3 . 8 1 . 1 45 170 50
LATENT HEAT EXHAUST FAN ALLOWANCE 0 . 0 1 . 9 45 0 84
WALL 9 X 9 FT, FRAME OR VENEER, R19 INSUL 4 .2 1 . 7 72 302 122
WALL 10 X 9 FT, FRAME OR VENEER, R19 INSUL 4 .2 1 . 7 81 340 138
INFILTRATION, LOSS 1 .2 AC/HR GAIN . 5 AC/HR 136 . 9 17 . 1 9 1232 154
LATENT HEAT INFILTRATION ALLOWANCE 0 . 0 20 . 1 9 0 181
ALLOWANCE FOR BATHROOM COMFORT 0 .2 0 . 0 2572 514 0
TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN
CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 43 3086 1033
FOR FORCED AIR HEATING OR AIR CONDITIONING:
REQUIRES : 1 BRANCH DUCT - (5 IN ROUND) OR (5 IN OVAL) OR (3-1/4 X 8 WALL STACK)
REQUIRES : 1 #661 6 X 4 SIDEWALL REGISTER OR 1 #411 2-1/4 X 10 FLOOR DIFFUSER OR
REQUIRES : 1 #16 6 IN ROUND CEILING DIFFUSER OR 1 #24 6 X 6 INCH SQUARE DIFFUSER
REQUIRES : 1 #650 10 X 6 INCH RETURN AIR GRILL, OR ONE 3-1/4 X 14 IN-WALL RETURN
KITCHEN, EAST & NORTH HEAT COOL VALUE LOSS GAIN
1 WINDOW DOUBLE GLASS LOW E 70 X 48 IN, NO 31 . 0 64 . 0 23 723 1493
1 WINDOW DOUBLE GLASS LOW E 72 X 80 IN, NO 31 . 0 64 . 0 40 1240 2560
CEILING UNDER CONDITIONING, NO LOSS/GAIN 0 . 0 0 . 0 0 0 0
HARDWOOD FLOOR, Rll INS OVER ENCLOSED SPAC 2 . 8 0 . 0 460 1288 0
WALL 23 X 9 FT, FRAME OR VENEER, R19 INSUL 4 .2 1 . 7 144 605 245
WALL 20 X 9 FT, FRAME OR VENEER, R19 INSUL 4 .2 1 . 7 117 491 199
INFILTRATION, LOSS 1 .2 AC/HR GAIN . 5 AC/HR 101 .4 12 .2 63 6391 770
LATENT HEAT INFILTRATION ALLOWANCE 0 . 0 14 .4 63 0 904
ALLOWANCE FOR APPLIANCES AND MOTORS 0 . 0 2 . 0 600 0 1200
TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN
CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 219 10738 6467
FOR FORCED AIR HEATING OR AIR CONDITIONING:
REQUIRES : 2 BRANCH DUCT - (6 IN ROUND) OR (7 IN OVAL) OR (3-1/4 X 10 WALL STACK
REQUIRES : 2 #661 14 X 4 SIDEWALL REGISTER OR 2 #411 4 X 12 FLOOR DIFFUSER OR
REQUIRES : 2 #16 8 IN ROUND CEILING DIFFUSER OR 2 #24 6 X 6 INCH SQUARE DIFFUSER
REQUIRES : 2 #650 10 X 6 INCH RETURN AIR GRILL, OR TWO 3-1/4 X 14 IN-WALL RETURN
FAMILY ROOM, NORTH & EAST HEAT COOL VALUE LOSS GAIN
1 WINDOW DOUBLE GLASS LOW E 60 X 76 IN, NO 31 . 0 19 . 0 32 982 602
I ,a
CEILING UNDER CONDITIONING, NO LOSS/GAIN 0 . 0 0 . 0 0 0 0
HARDWOOD FLOOR, Rll INS OVER ENCLOSED SPAC 2 . 8 0 . 0 336 941 0
WALL 7 X 9 FT, FRAME OR VENEER, R19 INSUL 4 . 2 1 . 7 31 130 53
2 WINDOWS DOUBLE GLASS LOW E 24 X 76 IN, N 31 . 0 64 . 0 25 785 1621
FIREPLACE WITH LOOSE DAMPER 28 . 0 0 . 0 9 252 0
WALL 16 X 9 FT, FRAME OR VENEER, R19 INSUL 4 .2 1 . 7 87 365 148
INFILTRATION, LOSS 1 .2 AC/HR GAIN . 5 AC/HR 82 .4 9 . 6 57 4697 550
LATENT HEAT INFILTRATION ALLOWANCE 0 . 0 11 . 3 57 0 646
TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN
CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 114 8152 2974
FOR FORCED AIR HEATING OR AIR CONDITIONING:
REQUIRES : 2 BRANCH DUCT - (5 IN ROUND) OR (5 IN OVAL) OR (3-1/4 X 8 WALL STACK)
REQUIRES : 2 #661 10 X 4 SIDEWALL REGISTER OR 2 #411 2-1/4 X14 FLOOR DIFFUSER OR
REQUIRES : 2 #16 6 IN ROUND CEILING DIFFUSER OR 2 #24 6 X 6 INCH SQUARE DIFFUSER
REQUIRES : 1 #650 10 X 6 INCH RETURN AIR GRILL, OR ONE 3-1/4 X 14 IN-WALL RETURN
SUNROOM, EAST & SOUTH HEAT COOL VALUE LOSS GAIN
4 WINDOWS DOUBLE GLASS LOW E 28 X 76 IN, N 31 . 0 64 . 0 59 1832 3783
CEILING UNDER VENTILATED ATTIC, R38 INS 1 . 8 1 . 0 140 252 140
HARDWOOD FLOOR, Rll INS OVER ENCLOSED SPAC 2 . 8 0 . 0 140 392 0
WALL 14 X 10 FT, FRAME OR VENEER, R19 INSU 4 .2 1 . 7 81 340 138
3 WINDOWS DOUBLE GLASS LOW E 28 X 76 IN, N 31 . 0 32 . 0 44 1374 1419
WALL 10 X 10 FT, FRAME OR VENEER, R19 INSU 4 .2 1 . 7 -3 -13 -5
INFILTRATION, LOSS 1 .2 AC/HR GAIN . 5 AC/HR 20 . 9 2 . 6 103 2156 264
LATENT HEAT INFILTRATION ALLOWANCE 0 . 0 3 . 0 103 0 310
TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN
CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 195 6333 5739
FOR FORCED AIR HEATING OR AIR CONDITIONING:
REQUIRES : 2 BRANCH DUCT - (6 IN ROUND) OR (7 IN OVAL) OR (3-1/4 X 10 WALL STACK
REQUIRES : 2 #661 14 X 4 SIDEWALL REGISTER OR 2 #411 4 X 12 FLOOR DIFFUSER OR
REQUIRES : 2 #16 8 IN ROUND CEILING DIFFUSER OR 2 #24 6 X 6 INCH SQUARE DIFFUSER
REQUIRES : 2 #650 10 X 6 INCH RETURN AIR GRILL, OR TWO 3-1/4 X 14 IN-WALL RETURN
STUDY, SOUTH HEAT COOL VALUE LOSS GAIN
3 WINDOWS DOUBLE GLASS LOW E 28 X 67 IN, N 31 . 0 32 . 0 39 1212 1251
CEILING UNDER CONDITIONING, NO LOSS/GAIN 0 . 0 0 . 0 0 0 0
HARDWOOD FLOOR, Rll INS OVER ENCLOSED SPAC 2 . 8 0 . 0 224 627 0
WALL 16 X 9 FT, FRAME OR VENEER, R19 INSUL 4 .2 1 . 7 105 441 179
INFILTRATION, LOSS 1 . 2 AC/HR GAIN . 5 AC/HR 79 . 0 9 . 6 39 3080 374
LATENT HEAT INFILTRATION ALLOWANCE 0 . 0 11 . 3 39 0 439
TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN
CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 75 5360 1804
FOR FORCED AIR HEATING OR AIR CONDITIONING:
REQUIRES : 1 BRANCH DUCT - (6 IN ROUND) OR (6 IN OVAL) OR (3-1/4 X 10 WALL STACK
REQUIRES : 1 #661 10 X 4 SIDEWALL REGISTER OR 1 #411 2-1/4 X14 FLOOR DIFFUSER OR
REQUIRES : 1 #16 6 IN ROUND CEILING DIFFUSER OR 1 #24 6 X 6 INCH SQUARE DIFFUSER
REQUIRES : 1 #650 10 X 6 INCH RETURN AIR GRILL, OR ONE 3-1/4 X 14 IN-WALL RETURN
LIVING ROOM, SOUTH & WEST HEAT COOL VALUE LOSS GAIN
2 WINDOWS DOUBLE GLASS LOW E 28 X 76 IN, N 31 . 0 32 . 0 30 916 946
CEILING UNDER CONDITIONING, NO LOSS/GAIN 0 . 0 0 . 0 0 0 0
HARDWOOD FLOOR, Rll INS OVER ENCLOSED SPAC 2 . 8 0 . 0 224 627 0
WALL 14 X 9 FT, FRAME OR VENEER, R19 INSUL 4 .2 1 . 7 96 403 163
3 WINDOWS DOUBLE GLASS LOW E 28 X 76 IN, N 31 . 0 64 . 0 44 1374 2837
WALL 16 X 9 FT, FRAME OR VENEER, R19 INSUL 4 .2 1 . 7 70 294 119
INFILTRATION, LOSS 1 .2 AC/HR GAIN . 5 AC/HR 41 . 6 5 . 1 74 3080 374
LATENT HEAT INFILTRATION ALLOWANCE 0 . 0 5 . 9 74 0 439
TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN
CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 150 6694 4439
FOR FORCED AIR HEATING OR AIR CONDITIONING:
REQUIRES : 2 BRANCH DUCT - (6 IN ROUND) OR (6 IN OVAL) OR (3-1/4 X 8 WALL STACK)
REQUIRES : 2 #661 12 X 4 SIDEWALL REGISTER OR 2 #411 4 X 10 FLOOR DIFFUSER OR
REQUIRES : 2 #16 6 IN ROUND CEILING DIFFUSER OR 2 #24 6 X 6 INCH SQUARE DIFFUSER
REQUIRES : 1 #650 10 X 6 INCH RETURN AIR GRILL, OR ONE 3-1/4 X 14 IN-WALL RETURN
FOYER, WEST HEAT COOL VALUE LOSS GAIN
2 WINDOWS DOUBLE GLASS LOW E 7 X 46 IN, NO 31 . 0 64 . 0 4 139 286
1 WINDOW DOUBLE GLASS LOW E 36 X 80 IN, NO 31 . 0 64 . 0 20 620 1280
CEILING UNDER CONDITIONING, NO LOSS/GAIN 0 . 0 0 . 0 0 0 0
HARDWOOD FLOOR, Rll INS OVER ENCLOSED SPAC 2 . 8 0 . 0 168 470 0
WALL 12 X 9 FT, FRAME OR VENEER, R19 INSUL 4 .2 1 . 7 84 353 143
INFILTRATION, LOSS 1 .2 AC/HR GAIN . 5 AC/HR 96 . 3 11 . 9 24 2310 286
LATENT HEAT INFILTRATION ALLOWANCE 0 . 0 14 . 0 24 0 336
TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN
CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 67 3892 1995
FOR FORCED AIR HEATING OR AIR CONDITIONING:
REQUIRES : 1 BRANCH DUCT - (5 IN ROUND) OR (5 IN OVAL) OR (3-1/4 X 8 WALL STACK)
REQUIRES : 1 #661 10 X 4 SIDEWALL REGISTER OR 1 #411 2-1/4 X14 FLOOR DIFFUSER OR
REQUIRES : 1 #16 6 IN ROUND CEILING DIFFUSER OR 1 #24 6 X 6 INCH SQUARE DIFFUSER
REQUIRES : 1 #650 10 X 6 INCH RETURN AIR GRILL, OR ONE 3-1/4 X 14 IN-WALL RETURN
DINING ROOM, WEST HEAT COOL VALUE LOSS GAIN
2 WINDOWS DOUBLE GLASS LOW E 20 X 76 IN, N 31 . 0 64 . 0 21 654 1351
1 WINDOW DOUBLE GLASS LOW E 32 X 76 IN, NO 31 . 0 64 . 0 17 524 1081
CEILING UNDER CONDITIONING, NO LOSS/GAIN 0 . 0 0 . 0 0 0 0
HARDWOOD FLOOR, Rll INS OVER ENCLOSED SPAC 2 . 8 0 . 0 195 546 0
WALL 13 X 9 FT, FRAME OR VENEER, R19 INSUL 4 .2 1 . 7 79 332 134
INFILTRATION, LOSS 1 .2 AC/HR GAIN . 5 AC/HR 70 . 9 8 . 7 38 2695 330
LATENT HEAT INFILTRATION ALLOWANCE 0 . 0 10 .2 38 0 388
TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN
CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 98 4751 2896
FOR FORCED AIR HEATING OR AIR CONDITIONING:
REQUIRES : 1 BRANCH DUCT - (6 IN ROUND) OR (6 IN OVAL) OR (3-1/4 X 10 WALL STACK
REQUIRES : 1 #661 12 X 4 SIDEWALL REGISTER OR 1 #411 4 X 10 FLOOR DIFFUSER OR
REQUIRES : 1 #16 6 IN ROUND CEILING DIFFUSER OR 1 #24 6 X 6 INCH SQUARE DIFFUSER
REQUIRES : 1 #650 10 X 6 INCH RETURN AIR GRILL, OR ONE 3-1/4 X 14 IN-WALL RETURN
MASTER SUITE, SOUTH & WEST HEAT COOL VALUE LOSS GAIN
3 WINDOWS DOUBLE GLASS LOW E 24 X 24 IN, N 31 . 0 32 . 0 12 372 384
CEILING UNDER VENTILATED ATTIC, R38 INS 1 . 8 1 . 0 306 551 306
FLOOR OVER CONDITIONING, NO LOSS/GAIN 0 . 0 0 . 0 306 0 0
WALL 18 X 10 FT, FRAME OR VENEER, R19 INSU 4 .2 1 . 7 168 706 286
3 WINDOWS DOUBLE GLASS LOW E 32 X 64 IN, N 31 . 0 64 . 0 43 1323 2731
WALL 17 X 10 FT, FRAME OR VENEER, R19 INSU 4 .2 1 . 7 115 483 196
INFILTRATION, LOSS 1 .2 AC/HR GAIN . 5 AC/HR 85 .4 10 .4 55 4697 572
LATENT HEAT INFILTRATION ALLOWANCE 0 . 0 12 .2 55 0 672
DUCT IN UNCONDITIONED SPACE 0 . 10 0 . 15 SUB 813 671
TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN
CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 174 8945 5146
FOR FORCED AIR HEATING OR AIR CONDITIONING:
REQUIRES : 2 BRANCH DUCT - (6 IN ROUND) OR (6 IN OVAL) OR (3-1/4 X 8 WALL STACK)
REQUIRES : 2 #661 12 X 4 SIDEWALL REGISTER OR 2 #411 4 X 10 FLOOR DIFFUSER OR
REQUIRES: 2 #16 6 IN ROUND CEILING DIFFUSER OR 2 #24 6 X 6 INCH SQUARE DIFFUSER
REQUIRES : 2 #650 10 X 6 INCH RETURN AIR GRILL, OR TWO 3-1/4 X 14 IN-WALL RETURN
BATH MASTER, EAST & SOUTH HEAT COOL VALUE LOSS GAIN
1 WINDOW DOUBLE GLASS LOW E 45 X 46 IN, NO 31 . 0 64 . 0 14 446 920
CEILING UNDER VENTILATED ATTIC, R38 INS 1 . 8 1 . 0 182 328 182
FLOOR OVER CONDITIONING, NO LOSS/GAIN 0 . 0 0 . 0 182 0 0
EXHAUST FAN, 45 CFM WITH . 05 USAGE FACTOR 3 . 8 1 . 1 45 170 50
LATENT HEAT EXHAUST FAN ALLOWANCE 0 . 0 1 . 9 45 0 84
WALL 14 X 8 FT, FRAME OR VENEER, R19 INSUL 4 .2 1 . 7 98 412 167
1 WINDOW DOUBLE GLASS LOW E 69 X 46 IN, NO 31 . 0 32 . 0 22 683 705
WALL 13 X 8 FT, FRAME OR VENEER, R19 INSUL 4 . 2 1 . 7 68 286 116
INFILTRATION, LOSS 1 .2 AC/HR GAIN . 5 AC/HR 62 . 0 7 . 3 36 2233 264
LATENT HEAT INFILTRATION ALLOWANCE 0 . 0 8 . 6 36 0 310
ALLOWANCE FOR BATHROOM COMFORT 0 .2 0 . 0 4558 912 0
DUCT IN UNCONDITIONED SPACE 0 . 10 0 . 15 SUB 547 361
TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN
CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 94 6017 2765
FOR FORCED AIR HEATING OR AIR CONDITIONING:
REQUIRES : 1 BRANCH DUCT - (6 IN ROUND) OR (6 IN OVAL) OR (3-1/4 X 10 WALL STACK
REQUIRES : 1 #661 12 X 4 SIDEWALL REGISTER OR 1 #411 4 X 10 FLOOR DIFFUSER OR
REQUIRES : 1 #16 6 IN ROUND CEILING DIFFUSER OR 1 #24 6 X 6 INCH SQUARE DIFFUSER
REQUIRES : 1 #650 10 X 6 INCH RETURN AIR GRILL, OR ONE 3-1/4 X 14 IN-WALL RETURN
MASTERCLOSET, EAST HEAT COOL VALUE LOSS GAIN
CEILING UNDER VENTILATED ATTIC, R38 INS 1 . 8 1 . 0 117 211 117
FLOOR OVER CONDITIONING, NO LOSS/GAIN 0 . 0 0 . 0 117 0 0
WALL 13 X 8 FT, FRAME OR VENEER, R19 INSUL 4 .2 1 . 7 104 437 177
INFILTRATION (NO WALL OR CEILING OPENINGS) 0 . 0 0 . 0 0 0 0
DUCT IN UNCONDITIONED SPACE 0 . 10 0 . 15 SUB 65 44
TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN
CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 11 713 338
FOR FORCED AIR HEATING OR AIR CONDITIONING:
REQUIRES : 1 BRANCH DUCT - (5 IN ROUND) OR (5 IN OVAL) OR (3-1/4 X 8 WALL STACK)
REQUIRES : 1 #661 6 X 4 SIDEWALL REGISTER OR 1 #411 2-1/4 X 10 FLOOR DIFFUSER OR
REQUIRES: 1 #16 6 IN ROUND CEILING DIFFUSER OR 1 #24 6 X 6 INCH SQUARE DIFFUSER
REQUIRES : 1 #650 10 X 6 INCH RETURN AIR GRILL, OR ONE 3-1/4 X 14 IN-WALL RETURN
BALCONY, WEST HEAT COOL VALUE LOSS GAIN
1 WINDOW DOUBLE GLASS LOW E 60 X 72 IN, NO 31 . 0 64 . 0 30 930 1920
CEILING UNDER VENTILATED ATTIC, R38 INS 1 . 8 1 . 0 264 475 264
'V
FLOOR OVER CONDITIONING, NO LOSS/GAIN 0 . 0 0 . 0 264 0 0
WALL 12 X 8 FT, FRAME OR VENEER, R19 INSUL 4 .2 1 . 7 66 277 112
INFILTRATION, LOSS 1 .2 AC/HR GAIN . 5 AC/HR 107 . 8 13 .2 30 3234 396
LATENT HEAT INFILTRATION ALLOWANCE 0 . 0 15 . 5 30 0 465
DUCT IN UNCONDITIONED SPACE 0 . 10 0 . 15 SUB 492 404
TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN
CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 105 5408 3096
FOR FORCED AIR HEATING OR AIR CONDITIONING:
REQUIRES : 2 BRANCH DUCT - (5 IN ROUND) OR (5 IN OVAL) OR (3-1/4 X 8 WALL STACK)
REQUIRES: 2 #661 10 X 4 SIDEWALL REGISTER OR 2 #411 2-1/4 X14 FLOOR DIFFUSER OR
REQUIRES : 2 #16 6 IN ROUND CEILING DIFFUSER OR 2 #24 6 X 6 INCH SQUARE DIFFUSER
REQUIRES : 1 #650 10 X 6 INCH RETURN AIR GRILL, OR ONE 3-1/4 X 14 IN-WALL RETURN
BED ROOM # 2, EAST HEAT COOL VALUE LOSS GAIN
1 WINDOW DOUBLE GLASS LOW E 100 X 64 IN, N 31 . 0 64 . 0 44 1378 2844
CEILING UNDER VENTILATED ATTIC, R38 INS 1 . 8 1 . 0 165 297 165
FLOOR OVER CONDITIONING, NO LOSS/GAIN 0 . 0 0 . 0 165 0 0
WALL 15 X 8 FT, FRAME OR VENEER, R19 INSUL 4 .2 1 . 7 76 319 129
INFILTRATION, LOSS 1 .2 AC/HR GAIN . 5 AC/HR 45 . 5 5 . 5 44 2002 242
LATENT HEAT INFILTRATION ALLOWANCE 0 . 0 6 . 5 44 0 284
DUCT IN UNCONDITIONED SPACE 0 . 10 0 . 15 SUB 400 507
TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN
CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 132 4396 3887
FOR FORCED AIR HEATING OR AIR CONDITIONING:
REQUIRES : 2 BRANCH DUCT - (5 IN ROUND) OR (5 IN OVAL) OR (3-1/4 X 8 WALL STACK)
REQUIRES : 2 #661 10 X 4 SIDEWALL REGISTER OR 2 #411 2-1/4 X14 FLOOR DIFFUSER OR
REQUIRES : 2 #16 6 IN ROUND CEILING DIFFUSER OR 2 #24 6 X 6 INCH SQUARE DIFFUSER
REQUIRES : 1 #650 10 X 6 INCH RETURN AIR GRILL, OR ONE 3-1/4 X 14 IN-WALL RETURN
BED ROOM # 3 , WEST HEAT COOL VALUE LOSS GAIN
2 WINDOWS DOUBLE GLASS LOW E 32 X 64 IN, N 31 . 0 64 . 0 28 882 1820
CEILING UNDER VENTILATED ATTIC, R38 INS 1 . 8 1 . 0 196 353 196
FLOOR OVER CONDITIONING, NO LOSS/GAIN 0 . 0 0 . 0 196 0 0
WALL 14 X 8 FT, FRAME OR VENEER, R19 INSUL 4 . 2 1 . 7 84 353 143
INFILTRATION, LOSS 1 . 2 AC/HR GAIN . 5 AC/HR 85 . 3 10 . 2 28 2387 286
LATENT HEAT INFILTRATION ALLOWANCE 0 . 0 12 . 0 28 0 336
DUCT IN UNCONDITIONED SPACE 0 . 10 0 . 15 SUB 398 367
TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN
CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 95 4373 2812
FOR FORCED AIR HEATING OR AIR CONDITIONING:
REQUIRES : 1 BRANCH DUCT - (6 IN ROUND) OR (6 IN OVAL) OR (3-1/4 X 10 WALL STACK
REQUIRES : 1 #661 12 X 4 SIDEWALL REGISTER OR 1 #411 4 X 10 FLOOR DIFFUSER OR
REQUIRES : 1 #16 6 IN ROUND CEILING DIFFUSER OR 1 #24 6 X 6 INCH SQUARE DIFFUSER
REQUIRES : 1 #650 10 X 6 INCH RETURN AIR GRILL, OR ONE 3-1/4 X 14 IN-WALL RETURN
BATH RM # 1, WEST HEAT COOL VALUE LOSS GAIN
1 WINDOW DOUBLE GLASS LOW E 20 X 48 IN, NO 31 . 0 64 . 0 7 207 427
CEILING UNDER VENTILATED ATTIC, R38 INS 1 . 8 1 . 0 60 108 60
FLOOR OVER CONDITIONING, NO LOSS/GAIN 0 . 0 0 . 0 60 0 0
EXHAUST FAN, 45 CFM WITH . 05 USAGE FACTOR 3 . 8 1 . 1 45 170 50
LATENT HEAT EXHAUST FAN ALLOWANCE 0 . 0 1 . 9 45 0 84
WALL 6 X 8 FT, FRAME OR VENEER, R19 INSUL 4 .2 1 . 7 41 172 70
INFILTRATION, LOSS 1 .2 AC/HR GAIN . 5 AC/HR 110 . 0 12 . 6 7 770 88
LATENT HEAT INFILTRATION ALLOWANCE 0 . 0 14 . 8 7 0 103
ALLOWANCE FOR BATHROOM COMFORT 0 .2 0 . 0 1427 285 0
DUCT IN UNCONDITIONED SPACE 0 . 10 0 . 15 SUB 171 104
TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN
CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 27 1883 799
FOR FORCED AIR HEATING OR AIR CONDITIONING:
REQUIRES : 1 BRANCH DUCT - (5 IN ROUND) OR (5 IN OVAL) OR (3-1/4 X 8 WALL STACK)
REQUIRES : 1 #661 6 X 4 SIDEWALL REGISTER OR 1 #411 2-1/4 X 10 FLOOR DIFFUSER OR
REQUIRES : 1 #16 6 IN ROUND CEILING DIFFUSER OR 1 #24 6 X 6 INCH SQUARE DIFFUSER
REQUIRES : 1 #650 10 X 6 INCH RETURN AIR GRILL, OR ONE 3-1/4 X 14 IN-WALL RETURN
BATH RM # 2, EAST HEAT COOL VALUE LOSS GAIN
1 WINDOW DOUBLE GLASS LOW E 20 X 48 IN, NO 31 . 0 64 . 0 7 207 427
CEILING UNDER VENTILATED ATTIC, R38 INS 1 . 8 1 . 0 72 130 72
FLOOR OVER CONDITIONING, NO LOSS/GAIN 0 . 0 0 . 0 72 0 0
EXHAUST FAN, 45 CFM WITH . 05 USAGE FACTOR 3 . 8 1 . 1 45 170 50
LATENT HEAT EXHAUST FAN ALLOWANCE 0 . 0 1 . 9 45 0 84
WALL 8 X 8 FT, FRAME OR VENEER, R19 INSUL 4 .2 1 . 7 57 239 97
INFILTRATION, LOSS 1 . 2 AC/HR GAIN . 5 AC/HR 132 . 0 15 . 7 7 924 110
LATENT HEAT INFILTRATION ALLOWANCE 0 . 0 18 . 5 7 0 129
ALLOWANCE FOR BATHROOM COMFORT 0 .2 0 . 0 1670 334 0
DUCT IN UNCONDITIONED SPACE 0 . 10 0 . 15 SUB 200 113
TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN
CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 30 2204 869
FOR FORCED AIR HEATING OR AIR CONDITIONING:
REQUIRES : 1 BRANCH DUCT - (5 IN ROUND) OR (5 IN OVAL) OR (3-1/4 X 8 WALL STACK)
REQUIRES : 1 #661 6 X 4 SIDEWALL REGISTER OR 1 #411 2-1/4 X 10 FLOOR DIFFUSER OR
REQUIRES : 1 #16 6 IN ROUND CEILING DIFFUSER OR 1 #24 6 X 6 INCH SQUARE DIFFUSER
REQUIRES : 1 #650 10 X 6 INCH RETURN AIR GRILL, OR ONE 3-1/4 X 14 IN-WALL RETURN
BED ROOM # 4, SOUTH & WEST & EAST HEAT COOL VALUE LOSS GAIN
1 WINDOW DOUBLE GLASS LOW E 100 X 64 IN, N 31 . 0 32 . 0 44 1378 1422
CEILING UNDER VENTILATED ATTIC, R38 INS 1 . 8 1 . 0 238 428 238
HARDWOOD FLOOR, R30 INS OVER OPEN SPACE 3 . 6 1 . 0 238 857 238
WALL 14 X 13 FT, FRAME OR VENEER, R19 INSU 4 .2 1 . 7 138 580 235
WALL 17 X 13 FT, FRAME OR VENEER, R19 INSU 4 .2 1 . 7 177 743 301
WALL 17 X 13 FT, FRAME OR VENEER, R19 INSU 4 .2 1 . 7 177 743 301
INFILTRATION, LOSS 1 .2 AC/HR GAIN . 5 AC/HR 108 . 5 13 . 0 44 4774 572
LATENT HEAT INFILTRATION ALLOWANCE 0 . 0 15 . 3 44 0 672
DUCT IN UNCONDITIONED SPACE 0 . 10 0 . 15 SUB 950 496
TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN
CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 146 10453 3803
FOR FORCED AIR HEATING OR AIR CONDITIONING:
REQUIRES: 2 BRANCH DUCT - (6 IN ROUND) OR (6 IN OVAL) OR (3-1/4 X 8 WALL STACK)
REQUIRES : 2 #661 12 X 4 SIDEWALL REGISTER OR 2 #411 4 X 10 FLOOR DIFFUSER OR
REQUIRES : 2 #16 6 IN ROUND CEILING DIFFUSER OR 2 #24 6 X 6 INCH SQUARE DIFFUSER
REQUIRES : 1 #650 10 X 6 INCH RETURN AIR GRILL, OR ONE 3-1/4 X 14 IN-WALL RETURN
WHOLE BUILDING LOSS GAIN
LATENT GAIN FROM ALL SOURCES 6950
r
SYSTEM DESIGN:
REQUIRED SUPPLY TRUNK DUCT IS 40 X 8 REDUCED 2 INCHES EVERY 30 FEET
REQUIRED RETURN TRUNK DUCT IS 46 X 8 REDUCED 2 INCHES EVERY 30 FEET
GRAND TOTAL BTU HEAT LOSS AND SENSIBLE + LATENT figjAT GAIN (fFM LOSS GAIN
CFM AT RECOMMENDED MAXIMUM TRUNK VELOCITY OF 10140 FPM 1775' ' 93398 57812
+his certifi.'d that this plan and sp,.cificotions are tn.-
copies of the proposed building or alterations to a�
erected at
,3 7r,-QrA el-.S h "Dr.
together with amendments stated m application a
filed with plan and 1 agree to comply with all zonin,
i�ufiding and state laws and such orders as shall t
.suf d by the Building Department during pendent
of this application and finaf issuance of a bulidin.
oermit.
Signed
:-his plan ie approved subject to the condition that
orders and ordinances :^gulatine building shall be
�-,,piwd with
�Siac❑ fly Approved The6e flied with
:il,•g I,ispc:ctor Cfer�
®, CONSULTING STRUCTURAL ENGINEERS
CIANCI (A CIANci —
December 14, 2000
Re: Cornerstone Drive, 137
South Windsor, CT
Simsbury, CT
00 13101
Mr. Curtis Bubie
New England Carpentry, Inc.
55 Airport Road, Suite 201
Hartford, CT 06114
Mr. Bubie:
At your request, we made a visit to the above referenced residence on December 12, 2000. The
purpose of our meeting at the site was to observe the workmanship of the existing roof framing
system and offer our opinion on those items which are of concern to you. The following is a list
of the concerns we discussed and our recommendations for the required repairs:
• We recommend that 2 x 6 or 2 x 8 diagonal ties be installed at each existing 2 x 8 ceiling
joist at the master bedroom/bathroom area. These ties must connect the typical ceiling joist
to the upper ceiling joists over the master bedroom.
• ' We recommend that one 2 x 10 rafter be sistered to the existing 2 x 10 rafter that supports
the 14" LVL hip located over this area.
• We recommend that a new post consisting of 3 -2 x 6's be installed at the existing 14"
LVL valley beam. This post must be located over the partition between the foyer and
master bedroom. Additional 2 x 4's must be added in this partition to transfer the load
dowm to the double joist below.
• We recommend that 2 x 4 strong backs be installed at 3)2" on center over the ceiling joists
at the master bedroom. These strong backs must horizontally tie the 2 x 10 rafters to the
existing attic floor framing.
• We recommend that a new post consisting of 3 -2 x 6's be installed at the existing 14"
LVL valley beams over bedrooms#2 and#4. This post must be located over the bearing
wall below. Additional 2 x 4's must be added to transfer the load down to the supporting
beams. .An additional two ply 13"x 9'R"LVL transfer beam must be added into the second
floor framing below the new post at bedroom#2.
• We recommend that 2 x 6's @ 16" on center collar ties be installed throughout the entire
attic area.
• We recommend that two additional 2 x 6 studs be added to the existing stud located under
the bottom end of the 14" LVL valley beam in bedroom #2.
• We recommend that the two existing 14" LVL hip boards located above bedroom#3 be
removed and replaced with 2 x 12's. The existing LVL is cut down in width at the bottom
193 Wethershold Avenue. Hartford, ConnectiCLIL OG 1 14-1 1 13
Phone (FG01 527-6415 TeI(-;f;,x: 1,24;n1 :):1 ?-'I r119
Cornerstone Drive, 137
South Windsor, CT Page 2
end and is very poorly fitted at the ridges. We also recommend that 2 x 6 or 2 x 8 ceiling -�
joists be installed in ;this area.
• We recommend that 2 x 6 or 2 x 8 ceiling joists be installed at the family room/sun room
area to tie the two exterior wall plates together. The connection of the ceiling joist to the
rafters and any splices in the ceiling joist must contain a minimum of 12 - 12d nails.
Please be advised that we have not thoroughly inspected the entire residence nor have we
performed computations to confirm code compliance of the member sizes used. The
recommendations noted above address workmanship and generally accepted framing details in
the industry.
We trust that this meets your needs at this time.
PoiC�'AtN Y Very truly yours,
::....w .
%
.! CIANCI & CIANCI
•
•• Ronald E. ZurefV
Staff Engineer
CIANCI&CIANCI CONSULTING STRUCTURAL ENGINEERS
LAW OFFICES
OWA INGS,LANZA AND PURNF AGEN,L.L.C.
1610 ELL,INGTON ROAD
POST OFFICE BOX"7
SOUTH W1NDSCW,CONN.Yf074-M7
FAX(W)644-3347 EDWARD R KUEHN
OFCOUNM
HAROLD R.CUMMINGS
MICHAEL I LANZA
VQTCE1VT J.puRNIIAGEN
August 24,2000
Town of south Windsor
Building Dept.
1540 Sullivan Avenue
South Windsor,Ct. 06074
RE: Lot No. 19 Cutler Ridge II Subdivision
To Whom It May Concern:
H. It is
Cornerstone Associates,LLC,the owner of Lot No. 18 in Cutler Ridge building
I represent 153 Corne lied for a bui ng
that Mr.Robert Jackston,the owner of Lot No. 19,has applied of m client's
my � granted unless he is able to modify the grade Y
permit,and this permit will not be
property in order to satisfy Town slope regulations.
l�ston has my client's permission to have a temporary slope right
Please be advised that Mr. Jac
easement over Lot No.
18 so that he can move forward with the construction of improvements
on Lot No. 19.
have an uestion with respect to ve,please feel free to contact me.
If you ha Y Q
i
t
'chael J.Lanza
r
Robert N. Jackston
330 Abbe Road Ext.
South Windsor, Ct 06074
August 25,2000
Town of South Windsor
Building Dept.
1540 Sullivan Avenue
South Windsor, Ct 06074
Re: Regarding Lot No. 18 Cutler Ridge II Subdivision
To Whom It May Concern:
I Robert N. Jackston,the owner of Lot No. 19, 137 Cornerstone Drive, Cutler Ridge II
Subdivision,does grant to 153 Cornerstone Associates the owner of Lot No. 18
permission to enter and regrade my property as necessary upon the installation of the
proposed retaining wall as depicted on the Cutler Ridge II Subdivision plans. Should you
have any questions,please feel free to call me at 860-296-9560.
Sin ly,
Ro N. ackston
a�
I
u�Jl�
0 . 06 ,
01
13 . 00 +
0 U 2
26 . 00
0+-;2 Q.
�.r26 ° OOG 4
UU
0 . 00
(.-�-i fr�-S Fi( o�► 9 o°
C�3
0 CONSULTING STRUCTURAL ENGINEERS
CIANCI a CIANCI
December 14, 2000
Re: Cornerstone Drive, 137
South Windsor, CT
Simsbury, CT
00 13101
Mr. Curtis Bubie
New England Carpentry, Inc.
55 Airport Road, Suite 201
Hartford, CT 06114
Mr. Bubie:
At your request, we made a visit to the above referenced residence on December 12, 2000. The
purpose of our meeting at the site was to observe the workmanship of the existing roof framing
system and offer our opinion on those items which are of concern to you. The following is a list
of the concerns we discussed and our recommendations for the required repairs:
We recommend that 2 x 6 or 2 x 8 diagonal ties be installed at each existing 2 x 8 ceiling
joist at the master bedroom/bathroom area. These ties must connect the typical ceiling joist
to the upper ceiling joists over the master bedroom.
•" We recommend that one 2 x 10 rafter be sistered to the existing 2 x 10 rafter that supports
the 14" LVL hip located over this area.
• We recommend that a new post consisting of 3 -2 x 6's be installed at the existing 14"
LVL valley beam. This post must be located over the partition between the foyer and
master bedroom. Additional 2 x 4's must be added in this partition to transfer the load
down,to the double joist below.
• We recommend that 2 x 4 strong backs be installed at 32" on center over the ceiling joists
at the master bedroom. These strong backs must horizontally tie the 2 x 10 rafters to the
existing attic floor framing.
• We recommend that a new post consisting of 3 - 2 x 6's be installed at the existing 14"
LVL valley beams over bedrooms#2 and#4. This post must be located over the bearing
wall below. Additional 2 x 4's must be added to transfer the load down to the supporting
beams. An additional two ply 1"4"x 9" "LVL transfer beam must be added into the second
floor framing below the new post at bedroom#2.
• We recommend that 2 x 6's @ 16" on center collar ties be installed throughout the entire
attic area.
• We recommend that two additional 2 x 6 studs be added to the existing stud located under
the bottom end of the 14" LVL valley beam in bedroom #2.
• We recommend that the two existing 14" LVL hip boards located above bedroom #3 be
removed and replaced with 2 x 12's. The existing LVL is cut down in width at the bottom
1
" 198 Wethersfield Avenue, Hartford, Connecticut 061 14-1 1 13
Phone (860) 527-6415 Tr k-Jax• (�Can) P•,19-1�1�3
.J
Cornerstone Drive, 137
South Windsor, CT Page 2
end and is very poorly fitted at the ridges. We also recommend that 2 x 6 or 2 x 8 ceiling �
joists be installed in ;this area.
• We recommend that 2 x 6 or 2 x 8 ceiling joists be installed at the family room/sun room
area to tie the two exterior wall plates together. The connection of the ceiling joist to the
rafters and any splices in the ceiling joist must contain a minimum of 12 - 12d nails.
Please be advised that we have not thoroughly inspected the entire residence nor have we
performed computations to confirm code compliance of the member sizes used. The
recommendations noted above address workmanship and generally accepted framing details in
the industry.
We trust that this meets your needs at this time.
CO'A1N very truly yours,
AA g� ,. %
CIANCI & CIANCI
• r
•• �cS .'' "`' Ronald E. ZurefV
Ile
....•-
Staff Engineer
CIANCI&CIANCI CONSULTING STRUCTURAL ENGINEERS