Loading...
HomeMy WebLinkAbout1751 Ellington Road 9 FINAL INS P TI S: Building Z APPLICATION FOR BUILDING PERMIT Plumbing HVAC Date: Sprinkler 1751 ELLINGTON ROAD Electric Estimated Cost $ .235",oad Zoning Permit Fee $ 2- Affidavit NO. 19105 Occupancy Fee $ Eng. Dept. COMPLETE RED BOXED AREAS. 3 Fire Dept. TYPE OR PRINT ONLY Total Fee $ 63 Health Not. SIGN ON REVERSE SIDE. Approved for CO: (Additional Cost) $ TO BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT The undersigned, hereby applies to do work according to the following specifications: Job Location 7 it Lot No. Side of Street Zone Applicant 'KC4 Tel. # &gq_g74 Address Q ?d- Wwid5oy Cl— Zip a o'?4 Lic.# STREET CITY TE Owner SK " �C-v -----Address OR +M . (',()t v?df&1r C 7 06-0,2 Architect of Address CT Size New Area: Ft. Front Overall Ft. Deep Overall Total Area �#Garages Lavatories ' of Fan s No. of Stories Construction Bathrooms Rooms 1 st 2nd 3rd Size of Lot Dist. from Street Line Dist. from Side Street Line Purpose of this Permit 1 < < (Inc c 0m 1J0 b6QE, ew%0 — City Water Well ❑ Septic ❑ Sewer l� Approved by Jae- Dat y12- f/ BoiA 11/88 I h reby agree to conform to all th requirem nts of th Laws of th Stat of Connecticut and the Ordinanc s of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines and required distances from all other zones and is located in a zon in which this building and its us is allowed. Signed- 6 I hereby apply for a Certificate of Occupancy for the work described in this app ication for permit. Signed —DO NOT WRITE BELOW THIS LINE— Footin ti-f Y-q I INSPECTION RECORD Framing � �- Foundation Fireplace/Chimney Insulation Plumbing Permit# Inspections: HVAC Permit# Inspections: Electrical Permit# Inspections: Sprinkler Permit# Inspections: ' PERMIT DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT Application is hereby: TOWN OF SOUTH WINDSOR APPROVE DISAPPROVED BUILDING INSPECTION DEPT. 644-2511 Ext. 230 Application must be printed or typed . Da a Building Inspector 1. LOCATION OF JOB- l7.� ��Z_i•v��eW :? FEE SCHEDULE No. Street $ 0 - $19000 - $10.00 Floor Apt . No. Over $1,000 - $10.00 per $1 ,000 or 2 . OWNER fraction thereof 3. ADDRESS Fd!r,y G" (y C7 4. APPLICANT 5 . ADDRESS C Ff7� b q,o 6. ESTIMATED COST $ 7 . IS THIS A CONTRACT COST Yes Xz 8 . FEE ENCLOSED $ t>Oaj 9. TYPE OF BUILDING : RESIDENTIAL ` CTMMERCIAL 10. TYPE OF JOB : tl Original Installation Alteration/Addition/Repair BD 3A 11/88 APPLICATION FOR ELECTRICAL PERMIT (Continued from Reverse Side) 11 . LOCATION OF JOB 1 75- / &2(-406-ft-,y NO . STREET APT. NO . 12 . TYPE OF INSTALLATION 13 . SIZE OF MAIN FEEDER 14 . NO. OF LIGHT LOOPS 15 . NO. OF HEAT LOOPS 16. NO. OF POWER LOOPS 17 . NO. OF LIGHT OUTLETS 18 . NO . OF HEAT CIRCUITS 19. NO. OF POWER OUTLETS 20 . NO. OF CONVENIENCE OUTLETS 21. NO. OF HEAT CIRCUITS 22 . NO. OF POWER CIRCUITS 23 . NO. OF LIGHT CIRCUITS 24 . SIZE OF HEAT CIRCUITS 25 . NO. OF MOTORS 26 . NO. OF PANELS 27 . TOTAL WATTAGE 28 . NO. OF POWER FEEDERS 29 . NO. OF SWITCHES 30. A/C LOAD 31. SIZE OF POWER FEEDERS 32 . NO. OF FIXTURES 33. TOTAL HORSEPOWER 34 . NAME OF SUBCONTRACTORS AND THEIR TRADES 35 . REMARKS AND FURTHER DETAILS : fi./ - A!,� Zov 'rf Ate iv Ap LICENSE NO . SIGNATURE OF APPLCCA.4 DATE PHONE NUMBER: Lot N(,._ f a Building Permit Temporary Service rmanent Service +6- e S � Pursuant to Permit No. This Certifies that the Electrical Work for which the above named Permit was granted has been duly inspected and is hereby approved. r Owner Electrician PQt-6 6 N 1 Street L( ('N y-7y'N (�CJ f)7 1gn Building Inspector a FINAL INS NS: ?V Building r �,� APPLICATION FOR BUILDING PERMIT Plumbing HVAC Date:�_�'-`1 Sprinkler 1751 ELLINGTON ROAD Electric Estimated Cost $ 6-6 Od U Zoning 19319 Permit Fee$ Affidavit NO. Occupancy Fee $ Eng. Dept. COMPLETE RED BOXED AREAS. Fire Dept. TYPE OR PRINT ONLY Total Fee $ H alth D Pt. SIGN ON REVERSE SIDE. Approved for CO: (Additional Cost) $ TO BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT The undersigned, hereby applies to do work according to the following specifications: Job Location 1/L.l w Lot No. Side of Street Zone Applicant Ks' K— ) 'J---nL— Tel. # 4o W-97�01 Address 17��I Elh nc,?�n 1rt)(,v-dx) c-r Zip aeo` Lic,# ST E TtO k`� CITY $�TE Owner - -----Address 7,!{ Architect " W►�Wla���Address Size New Area: Ft. Front Overall Ft. Deep Overall Total Area #Garages Lavatories No. of Families No. of Stories Construction Bathrooms Rooms 1st 2nd 3rd Size of Lot Dist. from Street Line Di5l,from Side-street Line Purpose of this Permit X0 City Water Well ❑ Septic ❑ Sewer- fY Approved by Date uf BD1A 11/88 I hereby agree to conform to all th requirem nts of the Laws of th Stat of Connecticut and the Ordinanc s of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located th proper distanc from all street lin s,sid yard lin s an required distanc s from all oth r zon s and is located in a zone in which this building and its use is allowed. Signed r1W I hereby apply for a Certificate of Occupancy for the work described in this appl ation for permit. Signed- -DO NOT WRITE BELOW THIS LINE— INSPECTION RECORD Footing Framing Foundation Fireplace/Chimney Insulation V,G. 6/�.0'( cic� G Plumbing Permit# a�� Inspections ���`� / �0 9�6�7I J MA'� , ► /V/vfic HVAC Permit'v -Inspections: Electrical Permit# f 7 InspectionS.A T--) =I-I 41-Io -9 i, v'AJC_ Sprinkler Permit# Inspections: PERMIT NO. DEPARTMENT DECISION APPL I CATION FOR Application is hereby: PLUMBING PERMIT TOWM OF SOUTH WINDSOR (A:P:P:P,:O:7V0 DISAPPROVED BUILDING INSPECTION DEPT. V 644-2511 Ext. 230 Da a Building Inspector Application must be printed or typed. 1. LOCATION OF JOB: ZZ�� FEE SCHEDULE 2. OWNER: $ 0 - $19000 - $10.00 3. ADDRESS: Over $1 ,000 - $10.00 per $1 ,000 or 4. APPLICANT: fraction thereof 5. ADDRESS: , 6. EST. COST: $ a 6o 7. IS THIS A CONTRACT COST? YES NO 8. FEE ENCLOSED: $ C �P 9. TYPE OF BUILDING: RESIDENTIAL COMM RCIAL 10. TYPE OF JOB: ORIGINAL ALTERATION INSTALLATION ADDITION REPAIR BD 2A 11/88 APPLICATION FOR PLUMBING PERMIT (Cont. from Reverse Side) 11. LOCATION OF JOB: � a!�c GENERAL P UMBING 12. KIND OF INSTALLATION: 13. SIZE OF MAIN DRAIN 14. NO. OF TOILETS STYLE 15. NO. OF URINALS o2 STYLE - 16. NO. OF BATHTUBS 1 A. NO. OF SHOWERS 17. NO. OF LAVATORIES 18. NO. OF SINKS oL 19. DISPOSAL 19A. DISWASHER 20. NO. OF CONDUCTORS SIZE 21. NO. OF STACKS SIZE 22. AREA OF ROOF 23. NO. OF CATCH BASINS 24. NO. OF FLOOR DRAINS 25. NO. OF OTHER FIXTURES KIND u 26. ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW? 27. SIZE OF WINDOW 28. IF NO WINDOW, WHAT KIND OF VENTILATION IS THERE? 29. SIZE OF DUCTS 30. SEWER OR SEPTIC TANK? 31. SIZE OF WATER MAIN z 31A. SIZES OF WATER PIPING & RISERS �y 32. REMARKS AND FURTHER DETAILS WATER HEATER 33. TYPE 34. MANUFACTURER TANKS SAFETY DEVICES TEMPERATURE 35. CAPACITY 39. RELIEF VALVE 36. TEST PRESSURE LBS. 40. MANUFACTURER 37. WORKING PRESSURE LBS. 41. PRESSURE RELIEF VALVE 38. TYPE 42. :MANUFACTURER z� / A rc LICENSE NO. DATE SIGNATURE OF APPLICANT PHONE NO. FOR OFFICE USE ONLY APPLICATION FOR HVAC PERMIT DATE: 4?/K_ Qv (N0. TOWN OF SOUTH WINDSOR EST.COS ; D`4- BLDG. PERMIT NO. 3 1540 SULLIVAN AVENUE FEE SOUTH WINDSOR, CT 06074 FEES: 644-2511 - Ext. 230 $ 0 - $19000 - $10.00 $1000 or fraction �e7Ar'l thereof - $10.00 LOCATION OF BUILDING 2-d z I Ze_r;6�j- J OWNER ADDRESS TOWN PHONE NO. HVAC-CONWACTOR ADDRESS �TOWR PHONE NO. TYPE OF SYSTEM: HEATING TYPE OF BUILDING: RESIDENTIAL A/C COMMERCIAL VENTILATION BUSINESS INDUSTRIAL IF HEATING: STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR UNIT RADIANT HEATER (INCLUDING WOOD/COAL BURNING STOVE) TYPE OF FUEL: OIL-GPM GAS IN-PUT ELECTRIC KW WOOD COAL OIL TANK - SIZE & LOCATION: INSIDE OUTSIDE CAPACITY LPG TANK - CAPACITY EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS (BTUH) 4 (HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE & MODEL NO.): GROSS HEATING CAPACITY (INPUT-BTUH) NET RATING (OUTPUT-BTUH) IF AIR CONDITIONING: DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE F TOTAL HEAT GAIN (BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE & MODEL NO.): TONNAGE COOLING CAPACITY (BTUH) IF VENTILATION: DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN EXHAUSE EQUIPMENT): TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM) (PLAN MUST ACCOMPANY APPLICATION) The undersigned hereby applies for a permit to perform the following work and is to comply with all local ordinances and State of Conn. Building Code in the performance of uch work. FURTHER DESCRIPTION OF WORK: o s 00, STATE LICENSLf - NAME & TYPE # E VNATUAE_O'F APPLICANT V� APPROVED IbAITE 6 D 4A 11/88 I - B a R CALCULATION SHEET IN3 (Modern Method) Copyright 1977 by The Hydronlcs Institute OWNER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATE COL.A COL.S COL.C COL.D COL.E COL.F COL.G 1 ROOM tt O H L W H L W H L W H L W H L W Design Water Temp. 2 ROOM DIMENSIONS, FT. F U STUH per Po t f 3 LENGTH EXPOSED WALLS,FT. < Radiation Selected 4 WINDOW AND OUTSIDE DOOR AREA U. STUN STUN BTUH STUN STUN 5 WALL CONSTRUCTION (Table 9,Lind 3 x H) ROOM LIN.FT.OF TOTALS RADIATION 6 TYPE OF GLASS FROM LINE 12 SELECTED (Bottom of table used f r Line 5) 7 CEILING CONSTRUCTION C (Table 9, L x W) g FLOOR CONSTRUCTIONt O (Table 9,L x W or Lin. F t) E 9 COLD PARTITION CONSTRUCTION F (Table 9, L x H) 10 c 1 Wall(With Openings) C G =0 H C' D 2 Wells(With Openings) eX 3 Wells lWith Openings) or Ent.Hall 11 TOTAL BTUH AT 70F TEMP DIFFERENCE' J 12 TOTAL BTUH AT DESIGN TEMP. DIFFERENCE K L COL.A _ _ COLS COL.H COL.1 COL.J COL.K COL.L TOTAL BTUH TOTAL 1 ROOM ¢ OF BUILDING SELECTED AT IATE O H L W H I L W H L W H L I W H L W DESIGN TEMP.- 2 ROOM DIMENSIONS, FT f' DIFFERENCE u _ _ 3 LENGTH EXPOSED WALLS, FT. 4 WINDOW AND OUTSIDE DOOR AREA LL STUN STUN BTUH BTUH BTUH 5 WALL CONSTRUCTION (Table 9,Line 3 x H) *INCREASE BATHROOM TOTAL 40'1t 6 TYPE OF GLASS --'— (Bottom of table used for Line 5) 7 CEILING CONSTRUCTION tFOR CONCRETE FLOOR ON (Table 9,L x W) GROUND OR FILL AT B FLOOR CONSTRUCTIONt GRADE LEVEL,USE LINEAR FEET OF EXPOSED EDGE (Table 9,L x W or Lin Ft.) 9 COLD PARTITION CONSTRUCTION (Table 9,L x H) 10 1 Wall(With Openings) 2 Walls(With Openings) e x 0 3 Wells(With Openings)or Ent.Hall Ia 11 TOTAL BTUH AT 70F TEMP DIFFERENCE* 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE This form is available from The Hyd►onics Institute,35 Russo Place,Berkeley Heights,N.J 07922 FORM 1503 FOR OFFICE USE ONLY APPLICATION FOR HVAC PERMIT DATE: (NO. 7 ) TOWN OF SOUTH WINDSOR EST.COST: BLDG. PERMIT NO. 1540 SULLIVAN AVENUE FEE � SOUTH WINDSOR, CT 06074 FEES: 644-2511 - Ext. 230 $ 0 - $19000 - $10.00 $1000 or fraction LOCATION OF BUILDING � � �� (,� - thereof - $10.00 OWNER ADDRESS TOWN PHONE NO. kk7Yv,-,Ac_cc� 1 t. ti �, c� moo, 4'�-4 HVAC CONTRACTOR ADDRESS TOWN PHONE NO. TYPE OF SYSTEM: HEATING _�� TYPE OF BUILDING: RESIDENTIAL A/C _ice COMMERCIAL _xe--, VENTILATION BUSINESS INDUSTRIAL IF HEATING: STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR UNIT RADIANT HEATER (INCLUDING WOOD COAL BURNING STOVE) TYPE OF FUEL: OIL-GPM GAS IN-PUT ELECTRIC KW WOOD COAL OIL TANK - SIZE & LOCATION: INSIDE OUTSIDE CAPACITY LPG TANK - CAPACITY EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS (BTUH) (HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE & MODEL NO.): 21- Ljevwtc�)< - c-..,,s(Z'�(-A Q!�l� GROSS HEATING CAPACITY (INPUT-BTUH) 2 gC�B NET RATING (OUTPUT-BTUH) 22.441C$ � IF AIR CONDITIONING: DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE F TOTAL HEAT GAIN (BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE & MODEL NO.): TONNAGE i3 COOLING CAPACITY (BTUH) IF VENTILATION: DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN EXHAUSE EQUIPMENT): TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM) (PLAN MUST ACCOMPANY APPLICATION) The undersigned hereby applies for a permit to perform the following work and is to comply with all local ordinances and State of Conn. Building Codes in the performance of such work. FURTHER DESCRIPTION OF WORK: STATE LICENSE - NAME & TYPE # DATE SIGNATURE OF APPLICANT APPROVED E BD 4A 11/88 I - B a R CALCULATION SHEET IN3 (Modern Method) Copyright 1977 by The Hydr nics Institute OWNER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATE C L.A COL.8 COL.C COL.D COL.E COL.F COL.G 1 ROOM O H L W H L W H L W H L W H L W Design Water Temp. 2 ROOM DIMENSIONS,FT. i" U BTUH per F I of 3 LENGTH EXPOSED WALLS,FT. t Radiation Selected 4 WINDOW AND OUTSIDE DOOR AREA U. BTUH BTUH BTUH BTUH BTUH 5 WALL CONSTRUCTION (Table 9. Line 3 x H) ROOM LON.FT.OFTOTALS RADIATION 6 TYPE OF GLASS FROM LINE 12 SELECTED (B it m of table used for Line 5) 7 CEILING CONSTRUCTION C (Table 9, L x W) g FLOOR CONSTRUCTIONt D (Table 9, L x W or Lin. Ft.) E 9 COLD PARTITION CONSTRUCTION F (Table 9, L x H) 10 c 1 Wall(With Openings) O G 2 Wells(With Openings) e x H D _ 1 3 Walls(With Openings) or Ent.Hall 1-eJ 11 TOTAL BTUH AT 70F TEMP DIFFERENCE' J 12 TOTAL BTUH AT DESIGN TEMP, DIFFERENCE K L COL.A _ _ _ COL.8 COL.H COL.1 COL_J COL.K COL.L TOTAL BTUH T TAL 1 ROOM R OF BUILDING AT SELECTION O H L W H I L W H L I W H I L-j W H L W DESIGN TEMP.' 2 ROOM DIMENSIONS.FT f' DIFFERENCE u 3 LENGTH EXPOSEO WALLS, FT. 4 WINDOW AND OUTSIDE DOOR AREA LL BTUH BTUH 8TUH BTUH BTUH 5 WALL CONSTRUCTION *INCREASE BATHROOM (Table 9, LIns 3 x H) TOTAL 20% 6 TYPE OF GLASS (Bottom f table used for Line 5) 7 CEILING CONSTRUCTION tFOR CONCRETE FLOOR ON (Table 9, L x W) GROUND OR FILL AT 8 FLOOR CONSTRUCTIONt GRADE LEVEL,USE LINEAR FEET OF EXPOSED EDGE (Table 9,L x W r Lin. Ft.) 9 COLD PARTITION CONSTRUCTION (Table 9, L x H) 10 C 1 Wall(With Openings) O =0 c~ 2 Walls(With Openings) e X p «` 3 Wells IWIth Openings) r Ent.Hall J 11 TOTAL BTUH AT 70F TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP. DIFFERENCE This form Is available fr m The Hydronlcs Institute,35 Russo Place,Berkeley Heights,N.J.07922 FORM 1503 JOB ZCNE NAME - RSK TDWN CENTER INSURANCE CO.?, INDOOR WINTER DESIGN TEMP - 70 ? WATTS PER SQ. FT. - LIGHTS - 3 ? LIG!" FLUORESCMd-- ? OTHER ELBMJCAL LOADS (WATIS/SQ.FT) - 0 ? O.K. l[d(_Tr TOTAL OTHER EE&lC RICAL .(WATTS)- 0 7 TERM AIR TEMP CLG -- 55 ? __ TERM AIR TlW HTG - 120 ? SUPPLY FAN EST STATIC PRESS - 2.75 ? SUPPLY VAN_AM*: 1=b.T4 r '2=fB.`I.= 1 ? -- BUILDING ORIENTATION 1=N f S,E r W 241W,NE,SE t SW - 1 DRAPE COLM: 1=LT, 2=MD, 3=WK t 4=NONE j 5=OTM t -- 4_ 7 ENTER THE TRANSMISSION FACTOR FCR THE N. WALL - '603 IS TRANS. FACTOR THE SAME FOR ALL WALLS (Y/N) - Y? ENTER THE TRANSMISSION FACTOR FOR THE ROOF - .03 ? _ TYPE 0 GU S.S sS4IMLElD DOL tT--TRIPLE,O=OIHER (S;D# W-0)=D?i INPUT VENT CFM AS Ls = PER SQ FT 2*'_ = PER PERSON 3. = AS % OF SUPPLY CFM 4. = TOTAL - 3 7 -` % SUPPLY AIR OF VENT.--AIR(0 TO 100)-;'10 ? - - --- --- - - INFIL CE M/SQ FT HTG - 0 ? INFIL. CEM HTG - 0 ? ... ... SQ FT/PERSON - 100 7 .._.... ...._... .. . .. .,.... ,-........•.___. r.......W._-....._......._.,... ._,..... ,_.._......-.. __ ...�____._._._. ,_ PEOPLE ACTIVITYl=SEATED AT REST (TIHFATER, ETC.)2=OE'FICE WORKER OR RETAIL STORE -_._3=SIDENTARY WORK (RESTAMAN'I')4=FAC,`IIO RY, LIGHT WORK 5=HEAVY WCRK6=OMER- 2 ? CHOOSE <B>IACK LOAD OR <Z>ONE LOAD ( B OR Z ) - B? ENTER LENGTH -OF N. OR S. WALKS (FEET) - 138 7 ENTER LENGTH OF E. OR W. WALLS (FEET) - 60 ? ENTER TOTAL HEIGHT OF WALLS (FEET) - 8 ? CEILING PLENUM - RETtRN AIR PLENUM (Y/N) - N? CALCULATE SHADING " OVERHANDS OR REVEALS(Y/N) - N? SPEM Y GLASS AREAS AS1. TOTAL2. $ Cr WALL AREA SAME EM ALL• ExPOSUPJ3S (1 OR 2) - 1 ? 1 ENTER AREA OF N. WINDOWS (SQ. FT.) - 298 ? ENTER AREA OF S. WINDOWS (SQ. FT.) - 298 ? I—ENTER AREA OF E. WINDOWS (SQ. FT.) - 88 ? ENTER AREA OF W. WINDOWS (SQ. FT.) - 88 7 R COALING % SAFETY FACTOR ( 0 TO 30 ) - 0 ? WlftRM-UP FACIM ( 0 TO 100 ) - 0 7 _.... . ... . .._-.. ...."....... ._....._._. -._ . .............. . ..__. ..._. _. ENTER TONAL OTHER ELBCTRICAL (WATTS)- 0 ? RSK TOWN CENTER INSURANCE CO. 07/10/90 V HARTFORD *CONNECTICUT LAT = 42 ALT a 58 IC CONST= 701W/40R/ 70B ID= 72/50 3 70 _.. WRM COiCt: MIDI! w.�.. ROOF C:CLCK • MUM - _. ..." - w_. r.. _._....... ra - SE R# 30206831.6 Eu D.B.TEMP TOTAL TONS RSH TONS CFM M--1:-"-JUN AT--9 A.M&--80.6 18.93-- 13.29 8#525 TJ 2. JUL AT 9 A.M4 83.6 19.93 13.60 8,730 3. SEP AT 10 A.M. 78.8 M 20 14.46 9,281 -4.'-OCT AT-2 P.M: 77.0 19.70 --- -"14.69 90,426 �- B 5. SEP AT 3 P.M. 88.0 21.80 15.16 '• 9s,728 ?B. 6. JUL AT 4 P.M. 93.0 21.95 14.56 9,346 7. JUN AT 4 P.M. 90.0 20.95 14.31 9,182 2V ZONE HFATING--> 74,984 W/INFI -- 74,984 CFM = 1,363 1PF INPUTS PDC- ORIENTATION CP BUILDING - -- N _ - SSION FACTORS 0.03 0.03 0.03 0.03 0.03 GL F= .55 IS LI=FLO Y SHADE FAC T-4.96 NO. FLODIi.S 1 �i 'i = 119 � WZDTH = 60 __..____ HEIGHT = 8 %VA.= 10 OUTPUTS uxv5t= /UW/4UJR/ /UB ID= 7 2/50 /U WALL COLOR Mh�3ItI►�1 ROOF COL,CR: MEDIC�i SER# 30206831.6 D.B.TEMP TOTAL TOM RSH TONS CENI AT_. 9 A.M.--"""80.6 " " "-""""""- 18.93 13.29 8,525 . 2. JUL AT~ 9 A.M. 83.6 19.93 13.60 8,730 3. SEP AT 10 A.M. 78.8 20.20 14.46 91281 4. OCT AT .-2 P.M. ..- 77.0 19.70 - 14.69 -- 9,426 !�- - 5. SEP AT 3 P.M. 88.0 21.80 15.16 9,728 6. JUL AT 4 P.M. 93.0 21.95 14.56 9,346 7. JUN AT 4 P.M. 90.0 20.95 14.31 9,182 ZONE HEATINS--> = 74,984 W/INFIL= 74,984 CAM = 1,363 INPUTS CRIENTATION OF BUILDING NTRANSMISSION FACTORS 0.03 0.03 0.03 0.03 0.03 GL F= .55 IS LI=FLO Y SHADE FAC,`T4.96 NO. FL001�4 1 LF3UM = 138 WIDTH 60" HEIC iT - 8 %VA.= 10 OUTPUTS NUMBER OF PEOPLE 83 SENSIBLE PEOPLE LOAD-= _ 20,286 TOTAL LIGHTS = 24,840 LIGHTIM LOAD = 10 5,974 OTHER ELECTRICAL = 0 OnM ELECTRICAL = 0 AREA OF N. GLASS = 298 NORTH (LASS SOLAR_4= 411563_ AREA OF S. 'GLASS.-- ----298 __.___- SOUTH GLASS SOAR - 90,189 AREA OF E. GLASS = 88 EAST GLASS SOAR - 2,2 39 AREA OF W. GLASS = 88 WEST GLASS SOLAR = 11,704 -- TOTAL GLASS ARFA - ___y 772 TOTAL GLASS SOLAR _ 27,695 TOTAL GLASS AREA = 772 TOTAL GLASS TRANS. = 8,917 ...._-AR8A__CF-_'N. MLI, = g06 - N. VALL LOAD =423� AREA OF S. WALL = 806 S. WALL LOAD = 736 AREA OF E. MLL = 392 E. WALL LOAD _ _ 252 AREA OF W. WALL = 392 W. MLL LOAD = _ 334 TOTAL WALL AREA = 2,396 TOM WALL TRANS. = 1,745 AREA OF ROB' = 8,280 ROOF LOAD = 10,159 SAFETY FACTOR 0% SAFETY B.T.U.S = 0 SUPPLY FAN H.P. = 7.36 FAN HEAT GAIN - DT _ _ 22,565 VENMLATION C FM = 935 O.A. SENSIBLE LOAD - = 21,590 NUMBER OF PEOPLE = 83 PEOPLE LATERr LOAD = 160,974 VENTILATION CAM = 935 O.A. LATENT LOAD _ 27,451 70M CM-STD AIR=-_... 9,34 6 TOTAL LATENT LOAD �_- 44,425 ROCM SENSIBLE = 174,775 ROOM LATENT = 16,974 .�.....- _ - RSK TOWN CENTER INSURANCE 00. _ --> GRAM TOTAL LOAD = 263,355 BTU'S OR 21.95 TONS <-- LOAD RUN Rat # 6. JUL AT 4 P.M. AREA (SQ FT) = 8,280 SQ FT/'ICON = 377 TOTAL C M-STD AIR-- 9,346 C,FK/SQ FT - 1.13 -- - HEATIN; LOAD - VENTILATION LOAD = 71,966 ROOF HEATING LOAD = 17,388 GLASS HEAT LOAD = 29,722 WAIF, HEATING LOAD -INFILTRATION I,C1�iD= -..- - 0 ._ � WARM UP LOAD _. _.. ._-._._._..___..._. ,.�0 SLAB HEATING LOAD= 22,842 HEAT LOAD WITH VENT = 146,950 COIL SELECTION PARAMETERS DB TEMP ENTAAn = 74.1 / 52.8 TOT SENSIBLE LOAD = 218,931 WB TEMP ENT/LVG = 62.1 / 52.2 TOTAL COIL LOAD = 263,355 SPECIFIED ROOM RH= 50% RESULTINS-7 R0 M RH = 51% TERMINAL AIR TEMP-- 55.00 / 120 DEGREES ROTATED = 0 SUPPLY FAN STATIC-- 2.75 NOWC EILIN RETURN - BLDG. 'U' FACTOR= 0.07 STAPLES DEFAULTS ----------------- ----------- ----------- ----------- ----------- ---- ------ - - - - APPLICATION FOR PERMANENT SIGN PERMIT Zoning Approval: 1751 Ellington Road Z�,�s to J Cost: S / OO o —T— Ref. _ No. 26�49 Est.Permit Fee: $_ Final lnspectio s: Approved: Building - J'� Electric # Zoning o3 Applicant Name �`��Py&ecit S _ AddressQC5 ')6C'C)F5T;`one Z�6—)`"t`.L-0d ?/ Location of Sign 12 S 1l�\ � {L� • Zone Sign Size (square feet) Sign Height # of signs on site: Free-standing A Wall TYPE of SIGN: (M Wall or❑ Free-standing ❑ New or f� Replacement Illuminated? ❑ Yes 12] No Description of sign materials and lighting: N4&)- j ,lljv1 claA-ILy 1� c ��.�fiYiS ATTACH DIAGRAM OF SIGN INCLUDING DIMENSIONS have read, understand and agree to abide by the South Windsor Zoning Regulations, Signs. SIGNATURE Date 00 Inspection / Approval Date By Appl ' Code Description Due Whom Code Comment ------------------------------------------------------------------------------- **-26749-B 1,000 B10 FINAL 09/25/00 JRC A CLOSED OUT.